Evaporator Rapid Design


STEAM and VAPOUR
Mass Flow Pressure Temperature
[tonne/h] [kPa abs] [°C]
V0 0.27 169.18 115.17
V1 0.14 87.77 96.18
V2 0.16 43.70 78.18
V3 0.19 11.18 48.18

JUICE and SYRUP


Mass Flow Brix Temperature
[tonne/h] [%] [°C]
Syrup 0 1.00 20.00 25.00
Syrup 1 0.86 23.39 96.74
Syrup 2 0.69 28.96 78.89
Syrup 3 0.50 40.00 49.21

HEATING SURFACE AREAS


Area OHTC Sp Evap Rate
Effect
[m2] [kW/m2/K] [kg/m2/h]
1 5 1.924 30.77
2 4 1.267 40.14
3 6 0.572 29.96

www.sugartech.com/rapiddesign/multeffect/calculate.php 1/1