8 FOOD
code inside diameter working pressure burst pressure weight nominal bending radius vacuum length max
Advice to users
on hoses in contact with food
www.ivgspa.it
CleanI NInDPlace information
U S T R I A L R U B B E R H O S E
IVG recommends for the first use a wash cycle with potable water at a maximum temperature
of 80°C/90°C and a hose sanitation as reported above before conveying food products.
At the end of each cycle the equipment and hose assemblies must be cleaned and disinfected.
Strictly follow the times indicated for each cleaning cycle.
Do not immerse hose assembly in the sanitation fluid because only the inner tube is suitable for
contact with the below mentioned solvents.
Every cleaning cycle must be immediately followed by a complete rinse.
Do not exceed 3 bar working pressure in CIP systems.
HOSE*
Hot Water Steam H2O2 1% H2O2 3% Peracetic Perac
open end Acid 0.1% Acid 0
FOOD SCOTLAND
FOOD VINOFLEX 90°C Max 130°C Max 70°C Max 30°C Max 50°C Max 30
FOOD FOODFLEX/IIR 8 hours 30 minutes 15 minutes 15 minutes 15 minutes 15 minu
OFFSHORE PL POTABLE
80°C Max 110°C Max 50°C Max 30°C Max 30°C Max 30
FOOD MILLENNIUM
8 hours 15 minutes 10 minutes 10 minutes 10 minutes 10 minu
TRUCK FOODFLEX
80°C Max 110°C Max 50°C Max 30°C Max 30°C Max 30
FOOD MERLOT
8 hours 15 minutes 10 minutes 10 minutes 10 minutes 10 minu
FOOD PARRY
FOOD ALICANTE
90°C Max 130°C Max 70°C Max 30°C Max 50°C Max 30
FOOD MILKSERVICE
8 hours 30 minutes 15 minutes 15 minutes 15 minutes 15 minu
FOOD SUPERJUICE
FOOD PANAMA
80°C Max 110 °C Max 50 °C Max 30 °C Max 30 °C Max 30
FOOD ACAPULCO
8 hours 10 minutes 10 minutes 10 minutes 10 minutes 10 minu
FOOD OILMILL
80°C Max 110 °C Max 80°C Max 50°C Max 70°C Max 50
FOOD ACQUABLU®
8 hours 30 minutes 30 minutes 30 minutes 30 minutes 30 minu
FOOD SHETLAND
90°C Max 130°C Max 80°C Max 50°C Max 70°C Max 50
CHEM THUNDERFLEX
12 hours 30 minutes 30 minutes 30 minutes 30 minutes 30 minu
CHEM SUPERTOP UPE
TRUCK DON/BN 80°C Max 110°C Max 50°C Max 30°C Max 30°C Max 30
TRUCK GORDON 8 hours 15 minutes 10 minutes 10 minutes 10 minutes 10 minu
* The indications regarding hoses on this list refer to the product code found in the IVG
catalogue www.ivgspa.it.
Clean In Place information
Al primo utilizzo, IVG raccomanda di effettuare un ciclo di lavaggio con acqua potabile alla
temperatura di 80°C/90°C e una sanificazione della manichetta prima di convogliare i prodotti
alimentari.
Al termine di ogni ciclo di utilizzo deve essere effettuata la detersione e la disinfezione delle
manichette.
Il rispetto dei tempi è fondamentale per ogni ciclo di lavaggio.
Non immergere la manichetta nel liquido di sanificazione poiché solo il sottostrato è idoneo al
contatto con i solventi indicati.
Ogni ciclo di lavaggio deve essere immediatamente seguito da un risciacquo completo.
Non utilizzare sistemi CIP oltre 3 bar di pressione.
0°C Max 30°C Max 80°C Max 80°C Max 80°C Max 30°C Max 70°C Max 30°C
nutes 15 minutes 15 minutes 15 minutes 15 minutes 15 minutes 15 minutes 15 minutes
0°C Max 30°C Max 50°C Max 70°C Max 70°C Max 30°C Max 50°C Max 30°C
nutes 10 minutes 15 minutes 15 minutes 10 minutes 10 minutes 10 minutes 10 minutes
0°C Max 30°C Max 50°C Max 70°C Max 70°C Max 30°C Max 50°C Max 30°C
nutes 10 minutes 15 minutes 15 minutes 10 minutes 10 minutes 10 minutes 10 minutes
0°C Max 30°C Max 80°C Max 80°C Max 80°C Max 30°C Max 70°C Max 30°C
nutes 15 minutes 15 minutes 15 minutes 15 minutes 15 minutes 15 minutes 15 minutes
0°C Max 50°C Max 80°C Max 80°C Max 80°C Max 50°C Max 80°C Max 50°C
nutes 30 minutes 30 minutes 30 minutes 30 minutes 30 minutes 30 minutes 30 minutes
0°C Max 50°C Max 80°C Max 80°C Max 80°C Max 50°C Max 80°C Max 50°C
nutes 30 minutes 30 minutes 30 minutes 30 minutes 30 minutes 30 minutes 30 minutes
0°C Max 30°C Max 50°C Max 70°C Max 70°C Max 30°C Max 50°C Max 30°C
nutes 10 minutes 15 minutes 15 minutes 15 minutes 10 minutes 10 minutes 10 minutes
* Le indicazioni riguardanti i tubi di questa lista fanno riferimento ai codici prodotto presenti
nel catalogo IVG www.ivgspa.it.
I N D U S T R I A L R U B B E R H O S E
General Advice
Hoses are not meant to permanently contain the products they convey.
Store hoses away from direct sunlight and heat. When not in use store hoses with
perforated plugs at both ends.
Before every use check the hose condition. The hose cover, especially in the fitting area,
should show no signs of cuts, tears, or bubbles. There should be no hard or weak areas,
signs of detachment or collapse.
Remember to guarantee traceability of every single piece of hose put into the market
(CE 1935/2004, CE 2023/2006)
I tubi in gomma hanno una durata che varia soprattutto The service life of rubber hoses mainly depends on the
in base all’utilizzo a cui sono destinati. Le dedicated use. Equipment and systems where the hose
apparecchiature e i sistemi in cui il tubo viene installato is installed must be designed safely. Since our hose
devono essere progettate in modo sicuro. In funzione can be designed for different applications, IVG
della varietà degli impieghi a cui il tubo può essere Colbachini SpA cannot guarantee the proper
destinato, IVG Colbachini SpA non garantisce il corretto functioning of the product for all situations. The analysis
funzionamento del prodotto per tutte le situazioni in of the technical aspects related to specific uses must be
quanto l’analisi degli aspetti tecnici relativi a impieghi performed by the users when choosing the product that
molto particolari è compito dell’utilizzatore al momento meets their requirements. So, in relation to the variety
di scegliere il prodotto più adatto alle proprie esigenze. of operating conditions and applications of the IVG
Dunque, in relazione alla varietà delle condizioni hose, the user is solely responsible for the final choice
operative e delle applicazioni per le quali i prodotti IVG of the product deemed suitable to satisfy the
possono essere acquistati, l’utilizzatore è il solo performance and safety requirements called for the
responsabile per la scelta finale del prodotto idoneo a application.
garantire i requisiti prestazionali e di sicurezza richiesti The information and technical data shown in the
dall’applicazione. product data sheets must be examined by users with
Le informazioni e i dati tecnici contenute nelle schede appropriate technical skills.
prodotto devono essere analizzate da utenti con IVG Colbachini is not responsible for other uses,
competenze tecniche adeguate. identified by the end user, that are different from the
IVG Colbachini non è responsabile per un uso diverso, one shown in its catalogues, product sheets, offers,
da parte dell’utilizzatore finale, da quello confermato nei order confirmations and any recommendations
propri cataloghi, schede prodotto, offerte, conferme attached.
d'ordine ed eventuali raccomandazioni allegate. An inappropriate choice of the product or a failure to
Una scelta inappropriata del prodotto o la mancata follow the procedures of installation, use, maintenance
osservanza delle procedure per l’installazione, l’uso, and storage of the hoses may lead to a hose break and
manutenzione e lo stoccaggio dei tubi può comportare cause material damage and/or serious injury to people.
la rottura del tubo e causare danni a cose e/o lesioni For the selection and proper use of the IVG products
gravi a persone. you can also refer to the document "Recommendations
Per la scelta ed un uso corretto dei prodotti IVG fare for selection, storage, use and maintenance of rubber
riferimento anche al documento “Raccomandazioni per hoses" provided by Assogomma and available on
la scelta, lo stoccaggio, l’uso e manutenzione dei tubi www.ivgspa.it. These recommendations are according
flessibili in gomma” fornite da Assogomma e disponibili to the international standard ISO 8331, "Plastic and
su www.ivgspa.it. Tali raccomandazioni sono in rubber hoses and hose assemblies - Guidelines for
accordo alla norma internazionale ISO 8331, “Tubi in selection, storage, use and maintenance."
gomma e plastica e tubi raccordati – Linee guida per la
scelta, stoccaggio, uso e manutenzione”. For safety reasons, never exceed the working
pressure indicated in the product data sheet.
Per motivi di sicurezza non va mai superata la
pressione di esercizio indicata nella scheda tecnica For specific applications of rubber hoses, please refer
del prodotto. to the legal requirements or specific standards;
moreover additional recommendations for particularly
Per impieghi specifici dei tubi in gomma si rimanda alle critical applications are available.
prescrizioni di legge o alle specifiche normative di For further information, contact the Marketing
rispondenza; in aggiunta sono disponibili ulteriori department (marketing@ivgspa.it).
raccomandazioni per impieghi particolarmente critici.
Per informazioni in merito, contattare il Servizio
Marketing (marketing@ivgspa.it).