The Formwork Experts.

Doka Express anchor


16x125mm
Art. n° 588631000

Fitting instructions
© by Doka GmbH, A-3300 Amstetten

© by Doka GmbH, A-3300 Amstetten


Fitting instructions Doka Express anchor 16x125mm

Installation and dismounting


Installation
A1 A2 A3 A4 A5

e
d STOP
f
c

9432-101

WARNING
➤ Use Doka coils 16mm only with the Doka
express anchor 16x125mm.
➤ Never use Doka coils 16mm on normal
standard screws or anchors.
➤ Screw the Doka coil 16mm onto the Doka
express anchor 16x125mm only in the direc-
tion indicated. Do not pre-spread.
➤ The express anchor may only be re-used
after performing a check for wear with the
Gauge for Doka express anchor
16x125mm, and provided that this check
has been successfully passed.

Dismounting and check for reusability


B1 B2 B3 B4.1

e B

f
B5.1 B5.2

! B4.2 B6.1

A1 A5
! B6.2

9432-101

a ... Nominal drill diameter 16 mm


b ... Depth of drilled hole 135 mm (The depth of the drilled hole b can be reduced by dimension c.)
c ... Max. thickness of attached part 15 mm
d ... Diameter of hole drilled in the attached part 17-25 mm
e ... Width-across 36 mm
f ... Torque Tmin 180 Nm
A Doka coil 16mm (art. n° 588633000)
Expendable part, can be used once only
B Gauge for Doka express anchor 16x125mm (art. n° 588632000)

2 999432002 - 11/2017
Fitting instructions Doka Express anchor 16x125mm

Structural design
Permissible values of temporary Permissible values of back-stays on
fixing points in uncracked concrete ring (values apply to uncracked
concrete)
F
F
c
9432-207-18

c
c ... max. thickness of attached part 15 mm
9432-207-18

c ... max. thickness of attached part 15 mm


20 9432-100
18 Permitted load where fck,cube ≥ 10 N/mm2:
16 Fperm. = 10.0 kN (Rd = 15.0 kN)
Tensile force Nperm. [kN]

14
12 NOTICE
10 If the ring is damaged (deformed), it is not per-
8 mitted to use this back-stay!
6
4
2
A B C D E
0
0 5 10 15 20 25 30 35 40

Shear force Vperm. [kN]

A C8/10 (fck,cube,current = 10 N/mm2)


B C12/15 (fck,cube,current = 15 N/mm2)
C C16/20 (fck,cube,current = 20 N/mm2)
D C20/25 (fck,cube,current = 25 N/mm2)
E C25/30 (fck,cube,current = 30 N/mm2)

Boundary conditions
s c

hef
9432-206-01

hmin

Anchoring depth hef ... 85 mm


Building-element thickness hmin ... 200 mm
Distance from edge c ... 400 mm
Distance s from one another ... min. 1200 mm

The following simplified values may be used:


▪ Permitted load in C8/10 concrete
with fck,cube,current ≥ 10 N/mm2:
Fperm. = 11.1 kN (Rd = 16.65 kN)
▪ Permitted load in C20/25 concrete
with fck,cube,current ≥ 25 N/mm2:
Fperm. = 17.6 kN (Rd = 26.4 kN)

NOTICE
If the boundary conditions differ from those
stated above, the approval Z-21.8-2033 must
be used!

999432002 - 11/2017 3