Aanuraj Fasteners 1 Raw materials Inspection, Only chemical report & Mill If MTC do not provide the
certificate.Agree to give PMI chemical testing of 80mm mechanical properties then
dia rods per lot.Confirms 100% chemical testing report get in tested from each lot
of rods/Lot. to know the as it is
mechanical properties. Final
properties shall be ensured
after HT.
HSFG & SS
Suppliers
Pancsheel 1 ISO 898 refers to Carbon & Alloy steel and not SS Yes, accordingly standard
Fasteners has been specified in ITP as
ISO 898 under HSFG
Fastener and ISO 3506-1
and ISO 3506-2 for
stainless steel fastener as
shown in the attached
approved ITP.
2 SS shall be made from solution annealed, strain Yes.
hardened material and NOT forged
3 SS A4-80 cannot be with specification of Gr 8.8, hence It is to be considered as per
• CLARIFICATION TO THE POINTS BELOW ON ANCHOR BOLTS & HSFG & SS BOLTS
Precison Fastners 1 Regarding A4-80: As per A480 for size 20mm and below Strictly as per standard
, tensile reuirement is 800 N/mm2 (Acceptable), for size specified in ISO 3506-1 and
above 20mm, we shall offer Tensile strength range of ISO 3506-2 and size
600 N/mm2 to 700 N/mm2 . (Std copy attached). specified in the Drg. Size
below and equal to M24 ,
standard calls for TS min
800 N/ sq mm.
2 In ITP Clause 2.2 & 2.3 not accepted, as 100% witness Under Cl 2.2 of ITP is
of dimension is practically not feasible, we can offer max dimension check and under
10% of total qty. Point no. 1.3-Mechanical testing for frequency of testing one in
HSFG shall be applicable as per IS 3757/ EN 14399-3, 500 pcs of bolt on sampling
.i.e full size tensile/wedge load test only, further batch basis has been referred.
size of 500 is not possible as it varies with size. We can Those samples will be
offer 3 samples /Heat and Batch size will vary 100% inspected. Total
individual bolts will not be
inspected.
Under Cl 1.3 for HSFG bolt,
testing frequency specified
in the ITP one in 2000 pcs
only and are mandatory.
M.Dharukhanawalla 1 Descripancy in legth mentioned in the table and on The table specified in the
actual drawing. Drg to be followed
2 ITP: Point no.1.1- Mechanical properties can be OK.
obtained only after heat treatment as per sr.no.3 and not
sr.1.1
3 scope of painting of assembly as mentioned in General OK
term(2) in drawing shall be not in suppliers scope it will
be in HCC's scope
Aanuraj Fasteners 1 ITP:-Raw material rod report for AISI 316 grade instead OK as per the standard
of IS1367 GR.8.8 ,& final product inspection will be as specified in ITP
per A4 80.
2 Raw material inspection.Raw material rod report for EN Raw material should be as
8 grade instead of IS1367 GR.8.8. Raw material rod specified in the standard
report for EN19 grade instead of IS1367 GR.10.9. mentioned in the ITP to
match the mechanical
properties.
• CLARIFICATION TO THE POINTS BELOW ON ANCHOR BOLTS & HSFG & SS BOLTS