You are on page 1of 1

JSK INDUSTRIES PVT.

LIMITED
SILVASSA, INDIA.

PROCESS FLOW CHART For ACSR Conductor

Refer : Process Flow Chart : Process Flow Aluminium Wire Rod


Chart for Aluminium Wire Rod for (EC Grade)
In-house Manufacturing of Aluminium Rod

QC
QC-1 : Inspection-1 Reject
Tensile Strength, Electrical Conductivity, (QC-1)
Chemical Composition, Surface, Visual Inspection
OR
Test Certificate Review of Supplier

PC-1 Wire Drawing


Process Control
1) Lubricant Flow To Final Wire
(PC-1)
2) Linear Speed of Wire Drawing Machine Size
3) Die Condition and Dimensions

QC- 2 :
Diameter, Tensile Strength,
Resistance , Wrapping QC
Inspection-2 Rework
(QC-2) / Reject
PC-2
1) Condition of Guide Bush/pulley `
2) Linear Speed of Conductor Stranding
3) Tension at the time of stranding Galvanised Steel Process Control
Wire
4) Winding of conductor on drum Wire /Stranded Core Stranding (PC-2)
5) Overall Diameter, Lay Ratio,
Lay Direction, Surface

QC- 3 :
Acceptance Test on Conductor as per relevant QC
Product Specification/Standard/Quality plan Inspection-3 Rework
(QC-3) / Reject

Indicates inspected & ACCEPTED


Packing &
Marking on
drum
Indicates inspected & NOT ACCEPTED

Customer
Inspection
or Waiver

Dispatch

You might also like