Professional Documents
Culture Documents
TC-1520E Equipment Case User's Manual ISI-4421-0059 Rev A PDF
TC-1520E Equipment Case User's Manual ISI-4421-0059 Rev A PDF
1 Introduction 1
1.1 Safety instructions ............................................................................................................... 2
5 Vehicle Installation 11
5.1 Seat Mounting Kit .............................................................................................................. 11
5.1.1 Adaptation for Right-Hand Driven Vehicles ....................................................................12
5.2 System Power Cable ......................................................................................................... 13
5.3 TC-1520E USB Interface .................................................................................................. 13
7 TC-1520E Specifications 14
8 Regulatory Qualifications 15
Note: The product warranty is void if the TC-1520E equipment case and its
components are opened in any way other than mentioned in this Installation Guide,
or if any seal or label is disturbed.
Only trained technicians may open and service the TC-1520E equipment case
components. For maintenance or repairs please contact Ascom Customer Service
at:
Phone: +1 855-323-5755
Email: customercare.tems@ascom.com
Web address: http://www.ascom.com
Note: No phone device accessories are delivered with the TC-1520E. All of these
items must be purchased separately.
2.2.1 Phones
The TC-1520E is primarily intended to be used with phone models supported by TEMS
Investigation 11.0 and later.
For information on what phones are supported by TEMS Investigation, please refer to
the web page www.ascom.com/en/index/support/support-tems/technical-support/tems-
investigation.htm.
Power connectors
WARNING: The UPS contains a lithium-ion battery pack (rated 14.8 V, 3800 mAh).
Do not store or operate the UPS in temperatures beyond the
specifications of the TC-1520E case (see chapter 7).
Do not ship the TC-1520E case with a charged battery. See Appendix
A for battery draining instructions.
If the battery fails to hold a charge, you need to return the TC-1520E
for service. Do not attempt to replace or remove the UPS battery.
WARNING: The TC-1520E is designed to have the lid open during operation.
Closing the lid will trap the heat generated by the devices and may
cause devices to shut down or be damaged.
The cigarette lighter plug has an integrated LED indicator. If this LED is not lit, the fuse
may be blown.
Recommended fuse: Fast-acting 3AG cartridge fuse, 32 V DC 15 A, Littelfuse,
0312015.HXP.
7 TC-1520E Specifications
Operating temperature: 0°C ... 40°C
Storage temperature: –20°C ... 50°C
Weight or case with no scanners or AQM modules installed: 4.2 kg (9.3 lbs)
Input voltage: 9 ... 18 V DC (12 V DC nominal 15 A)
Auxiliary power receptacle: 12 V DC nominal 10 A
UPS controlled internal power: 12 V DC at 7.5 A
Internal USB hub: 7 ports supporting USB 1.1 or 2.0, 5 V DC at 0.5 A per port.
Up to 8 phone cradles supported
Case dimensions: See the drawing below.
500
400
190