Professional Documents
Culture Documents
DATE
AREA CHECK ITEM ACTIVITY STANDARD CONDITION REMARK CONDITION REMARK CONDITION REMARK CONDITION REMARK
VOLTAGE : 12.4
B1 CHECK
V
VOLTAGE : 12.4
B2 CHECK
V
BATTERY VOLTAGE (PER BATTERY )
VOLTAGE : 12.4
B3 CHECK
V
VOLTAGE : 12.4
B4 CHECK
V
(0%=BAD ; 100%
B1 CHECK
= GOOD)
(0%=BAD ; 100%
B2 CHECK
= GOOD)
BATTERY (SOH//SOC) / Load tester
(0%=BAD ; 100%
B3 CHECK
= GOOD)
(0%=BAD ; 100%
B4 CHECK
= GOOD)
1 CHECK
STARTING CRANKING AMPERE MOTOR
2 CHECK
SOLENOID
ON BOARD
VHMS, JIGSAW & PAYLOAD CHECK FUNCTION
MONITORING
MECHANIC
NOTE: X = NOT OK
SIGN
✓= OK
GROUP LEADER
✪= OK AFTER REPAIR
SIGN
N/A = NOT AVAILABLE
INSPECTION ELECTRIC - CHECK SHEET
EQUIPMENT NUMBER : FT
B1 CHECK
B2 CHECK
BATTERY VOLTAGE (PER BATTERY )
B3 CHECK
B4 CHECK
B1 CHECK
B2 CHECK
BATTERY (SOH//SOC) / Load tester
B3 CHECK
B4 CHECK
1 CHECK
STARTING CRANKING AMPERE MOTOR
2 CHECK
SOLENOID
DATE
HOUR METER
VOLTAGE : 12.4
V
VOLTAGE : 12.4
V
VOLTAGE : 12.4
V
VOLTAGE : 12.4
V
(0%=BAD ; 100%
= GOOD)
(0%=BAD ; 100%
= GOOD)
(0%=BAD ; 100%
= GOOD)
(0%=BAD ; 100%
= GOOD)
26 V - 28.5 V
MIN: 26.5 V
2V-3V
24 V
STANDARD CONDITION REMARK CONDITION REMARK CONDITION REMARK CONDITION
STANDARD CONDITION REMARK CONDITION REMARK CONDITION REMARK CONDITION
PS 4
REMARK
REMARK
REMARK
INSPECTION ELECTRIC - CHECK SHEET
B2 CHECK
B2 CHECK
DATE
HOUR METER
VOLTAGE : 12.4
V
VOLTAGE : 12.4
V
(0%=BAD ; 100%
= GOOD)
(0%=BAD ; 100%
= GOOD)
27.6 V
16.8 V
13 V - 14.3 V
STANDARD CONDITION REMARK CONDITION REMARK CONDITION REMARK CONDITION
PS 4
REMARK
REMARK
INSPECTION ELECTRIC - CHECK SHEET
EQUIPMENT NUMBER :
SOH CHECK
BATTERY SOH & SOC
SOC CHECK
1 CHECK / REPLACE
AREA CHECK ITEM ACTIVITY
2 CHECK / REPLACE
3 CHECK / REPLACE
4 CHECK / REPLACE
ALL WORK LAMP
5 CHECK / REPLACE
LAMP
6 CHECK / REPLACE
7 CHECK / REPLACE
8 CHECK / REPLACE
CHECK/REPLACE EVERY
DC HARNESS
8000 HRS
CHECK/REPLACE EVERY
HARNESS AC HARNESS
8000 HRS
CHECK/REPLACE EVERY
PANEL HARNESS
8000 HRS
MECHANIC
NOTE: X = NOT OK
SIGN
✓= OK
GROUP LEADER
✪= OK AFTER REPAIR
SIGN
N/A = NOT AVAILABLE
PS 1 PS 2 PS 3 PS 4
WO NUMBER
DATE
HOUR METER
VOLTAGE=
12.4V
(0-30%=BAD
(REPLACE)
(0%=BAD ; 100%
= GOOD)
VOLTAGE = 12V
VOLTAGE =
13.5V-14.5V
STANDARD CONDITION REMARK CONDITION REMARK CONDITION REMARK CONDITION
NIC
EADER
N
PS 4
REMARK
REMARK
INSPECTION ELECTRIC - CHECK SHEET
B1 CHECK
BATTERY VOLTAGE (PER BATTERY )
B2 CHECK
B1 CHECK
BATTERY SOH & SOC
B2 CHECK
PULLEY CHECK
CHECK/REPLACE EVERY
DC HARNESS
8000 HRS
CHECK/REPLACE EVERY
HARNESS AC HARNESS
8000 HRS
CHECK/REPLACE EVERY
PANEL HARNESS
8000 HRS
SIGN
✓= OK
GROUP LEADER
✪= OK AFTER REPAIR
SIGN
N/A = NOT AVAILABLE
PS 1 PS 2 PS 3 PS 4
WO NUMBER
DATE
HOUR METER
VOLTAGE : 12.4
V
VOLTAGE : 12.4
V
(0%=BAD ; 100%
= GOOD)
(0%=BAD ; 100%
= GOOD)
VOLTAGE : 12V
STANDARD CONDITION REMARK CONDITION REMARK CONDITION REMARK CONDITION
EADER
N
PS 4
REMARK
REMARK
PT SAPTAINDRA SEJATI
PLANT DEPARTEMENT
EQUIPMENT NUMBER :
EMERGENCY STOP
EMERGENCY STOP
CLIPSAL (LOCK OUT SWITCH)
CONECCTION BATTERY
VOLTAGE :
OUTPUT ALTERNATOR (ALTERNATOR)
27V - 28.5 V
CHARGING
VOLTAGE :
OUTPUT (R) ALTERNATOR (SWITCH ON)
2V - 3 V
PULLEY
ALTERNATOR BELT
HARNESS STARTING
STARTING
GASKET STARTING
STARTING
TERMINAL STARTING
BATEREY RELAY
INDICATOR LAMP
CABIN LAMP
CABIN
ALL SWITCH
GAUGE
NAME
SIGN
Halaman belakang
BATTERY
CHECK KONDISI TERMINAL BATT
PASTIKAN CLAMP TERPASANG K
BATTERY CLAMP &TERMINAL
KOROSI PADA TERMINAL DAN CL
SPRAY BATTERY PROTECTOR AG
WO NUMBER
DATE
HOUR METER
Revisi : 0
ACTIVITY