LAMP INFO :
15 W LED, 1260 lm, wide flood optic, 3000K, CRI>80. L80/ B10
50,000h, 2 step MacAdam ellipse to ensure colour consistency
ATTACHMENTS :
Luminaire to be supplied with relevant fixing elements to suit on site
conditions. electronic drivers (refer to lighting control schedule for
dimming requirement/protocol) to be supplied by manufacturer of light
fixture.
NOTES :
Dark reflector, trim finish to be closest available RAL number to match
ceiling finish, IP65 min ingress protection.
LAMP INFO :
18 W LED, 1890 lm, flood optic, 3000K, CRI>80. L80/ B10
50,000h, 2 step MacAdam ellipse to ensure colour consistency
ATTACHMENTS :
Luminaire to be supplied with relevant fixing elements to suit on site
conditions. electronic drivers (refer to lighting control schedule for
dimming requirement/protocol) to be supplied by manufacturer of light
fixture.
NOTES :
Dark reflector, trim finish to be closest available RAL number to match
ceiling finish, IP65 min ingress protection.
LAMP INFO :
5 W LED, 720 lm, blade effect optic, 3000K, CRI>80. L80/ B10
50,000h, 2 step MacAdam ellipse to ensure colour consistency
ATTACHMENTS :
Luminaire to be supplied with relevant fixing elements to suit on site
conditions. Minimal amount of drivers to run the maximum number of
LEDs as per manufacturer’s recommendation. Drivers, to be supplied
by manufacturer of light fixture. minimum ingress protection IP20.
NOTES :
Dark reflector, trim finish to be closest available RAL number to match
ceiling finish, IP65 min ingress protection.
LAMP INFO :
10 W LED, 1050 lm, 25 degree beam angle optic, 2700K, CRI>90.
L80/ B10 50,000h, 2 step MacAdam ellipse to ensure colour
consistency
ATTACHMENTS :
Luminaire to be supplied with relevant fixing elements to suit on site
conditions. electronic drivers (refer to lighting control schedule for
dimming requirement/protocol) to be supplied by manufacturer of light
fixture.
NOTES :
Reflector to be satin gold finish and trim finish to be closest available RAL
number to match ceiling finish., IP20min ingress protection.
LAMP INFO :
10 W LED, 1050 lm, 25 degree beam angle optic, 2700K, CRI>90.
L80/ B10 50,000h, 2 step MacAdam ellipse to ensure colour
consistency
ATTACHMENTS :
Luminaire to be supplied with relevant fixing elements to suit on site
conditions. electronic drivers (refer to lighting control schedule for
dimming requirement/protocol) to be supplied by manufacturer of light
fixture.
NOTES :
Reflector to be matt black finish and trim finish to be closest available RAL number
to match ceiling finish., IP20min ingress protection.
LAMP INFO :
12W/m LED, 3000K, 894 lm/m, 120° beam angle, Outdoor rated,
CRI +80, binning requirement within 2 macadam steps.
ATTACHMENTS :
Luminaire to be supplied with mounting track & clips and
relevant fixing elements to suit on site conditions.
NOTES :
Interconnected fixing elements to maintain straight lengths,
Fixture to be supplied with tilt able fixing elements, actual angle
to be determined via on site mock up, Integral driver power.
Manufacturer MUST submit technical submittal
documentation, compliance statement and samples to LT
PLD for approval prior to full production. Mock-up required
for final LT PLD, KCA and contractor required for final
installation quality and fixture approval upon procurement.
LAMP INFO :
12W/m LED, 3000K, 894 lm/m, 9°x 29° beam angle, Outdoor
rated, CRI +80, binning requirement within 2 macadam steps.
ATTACHMENTS :
Luminaire to be supplied with mounting track & clips and relevant fixing
elements to suit on site conditions.
NOTES :
Interconnected fixing elements to maintain straight lengths,
Fixture to be supplied with tilt able fixing elements, actual angle
to be determined via on site mock up, Integral driver power.
Manufacturer MUST submit technical submittal
documentation, compliance statement and samples to LT
PLD for approval prior to full production. Mock-up required
for final LT PLD, KCA and contractor required for final
installation quality and fixture approval upon procurement.
LAMP INFO :
5 W/m, approx. 220 lm/m 3000K 3 step MacAdam ellipse to ensure
colour consistency
ATTACHMENTS :
To be supplied with fixing elements to suit on site conditions.
NOTES :
Minimal amount of drivers to run the maximum number of LEDs as
per manufacturer’s recommendation. IP20 min
LAMP INFO :
14.4 W/m, 1260 lm/m, 2700K 3 step MacAdam ellipse to ensure
colour consistency
ATTACHMENTS :
To be supplied with fixing elements to suit on site conditions.
NOTES :
Minimal amount of drivers to run the maximum number of LEDs as
per manufacturer’s recommendation. Min ingress protection IP65
LAMP INFO :
18W 1890 lm 3000K, flood beam angle, 2 step MacAdam ellipse to
ensure colour consistency
ATTACHMENTS :
To be supplied with all fixing elements to suit on site conditions.
NOTES :
Remote driver to be located within an accessible, temperature
controlled dislocation within a distance as per manufactures
recommendations (refer to lighting control schedule for dimming
requirement/protocol ). IP65 min ingress protection.
LAMP INFO :
18 W LED, 1463lm, 40 degrees beam angle, 3000K, CRI>80. L80/
B10 50,000h, 2 step MacAdam ellipse to ensure colour consistency
ATTACHMENTS :
Luminaire to be supplied with relevant fixing elements to suit on site
conditions. electronic drivers (refer to lighting control schedule for
dimming requirement/protocol) to be supplied by manufacturer of light
fixture.
NOTES :
Dark reflector, trim finish to be closest available RAL number to match
ceiling finish, IP20min ingress protection.
LAMP INFO :
26 W LED, 2250lm, 54 degrees 3000K, CRI>80. L80/ B10
50,000h, 2 step MacAdam ellipse to ensure colour consistency
ATTACHMENTS :
Luminaire to be supplied with relevant fixing elements to suit on site
conditions. electronic drivers (refer to lighting control schedule for
dimming requirement/protocol) to be supplied by manufacturer of light
fixture.
NOTES :
Fixed, reflector and trim finish to be closest available RAL number to match ceiling
finish. Passive heat dissipation system. Metalized, thermoplastic, high definition
optic, integrated in a rear position in the anti-glare screen. Glass cover for LED
lamp. IP20min ingress protection.
Manufacturer MUST submit technical submittal documentation, compliance
statement and samples to LT PLD for approval prior to full production. Mock-up
required for final LT PLD, KCA and contractor’s installation quality and fixture
approval upon procurement.
LAMP INFO :
9 W LED, 750 lm, 30 degrees 3000K, CRI>80. L80/ B10 50,000h,
2 step MacAdam ellipse to ensure colour consistency
ATTACHMENTS :
Luminaire to be supplied with relevant fixing elements to suit on site
conditions. electronic to be supplied by manufacturer of light fixture.
NOTES :
Fixed, reflector and trim finish to be closest available RAL number to
match ceiling finish. Passive heat dissipation system. Metalized,
thermoplastic, high definition optic, integrated in a rear position in the
anti-glare screen. Glass cover for LED lamp. IP20min ingress protection.
LAMP INFO :
5 W/m, 410 lm/m, 3000K, 3 step MacAdam ellipse to ensure colour
consistency
ATTACHMENTS :
Contractor to ensure to supplied with fixing elements to suit on site
conditions.
NOTES :
Minimal amount of drivers to run the maximum number of LEDs as
per manufacturer’s recommendation. Drivers, to be supplied by
manufacturer of light fixture. minimum ingress protection IP20.
LAMP INFO :
5 W/m, 410 lm/m, 3000K, 3 step MacAdam ellipse to ensure colour
consistency
ATTACHMENTS :
Contractor to ensure to supplied with fixing elements to suit on site
conditions.
NOTES :
Minimal amount of drivers to run the maximum number of LEDs as
per manufacturer’s recommendation. Drivers, to be supplied by
manufacturer of light fixture. minimum ingress protection IP20.
LAMP INFO :
10 W/m, LED RGB
ATTACHMENTS :
Contractor to ensure to supplied with fixing elements to suit on site
conditions based on required mock-up.
NOTES :
Minimal amount of drivers to run the maximum number of LEDs as
per manufacturer’s recommendation. Drivers, to be supplied by
manufacturer of light fixture. minimum ingress protection IP20.
LAMP INFO :
13W/m 3000K LED
ATTACHMENTS :
To be supplied with fixing elements to suit on site conditions.
NOTES :
Inbuilt driver type refer to lighting control schedule for dimming
requirement / protocol. Ground-, wall- and ceiling-recessed. Consists
of a
body and outer casing for installation, to be ordered separately.
Extruded aluminum body, with die-cast aluminum end caps
complete with silicone seals. Coated with liquid acrylic paint with a
high level of weather and UV ray resistance.. Min Ingress IP67
LAMP INFO :
15 W/m, approx. 770 lm/m 3000K 3 step MacAdam ellipse to ensure
colour consistency
ATTACHMENTS :
To be supplied with fixing elements to suit on site conditions.
NOTES :
Minimal amount of drivers to run the maximum number of LEDs as
per manufacturer’s recommendation. IP20 min
LAMP INFO :
Approx 5 W per sheet, approx. 600 lm/m 3000K
ATTACHMENTS :
To be supplied with fixing elements to suit on site conditions.
NOTES :
Minimal amount of drivers to run the maximum number of LEDs as
per manufacturer’s recommendation. IP20
LED sheet to be cut as per site conditions. To be coordinate with
supplier, to achieve the exact lite panel size.
LAMP INFO :
Approx 5 W/m, 400 lm/m, 3000K, 3 step MacAdam ellipse to ensure
colour
ATTACHMENTS :
To be supplied with fixing elements to suit on site conditions.
NOTES :
Dot-free light through opal encapsulation. Minimal amount of drivers
to run the maximum number of LEDs as per manufacturer’s
recommendation. Ingress IP67
LAMP INFO :
Approx 2.5 W per sheet, approx. 300 lm/m 3000K
ATTACHMENTS :
To be supplied with fixing elements to suit on site conditions.
NOTES :
Minimal amount of drivers to run the maximum number of LEDs as
per manufacturer’s recommendation. IP20
LED sheet to be cut as per site conditions. To be coordinate with
supplier, to achieve the exact lite panel size.
LAMP INFO :
44W LED, 4000K
ATTACHMENTS :
To be supplied with acrylic bullets accessory for stars light effect.
To be supplied with relevant fixing elements to meet on site
conditions as per manufacturer recommendation. To be supply
with Fiber Harness (50% 1mm diameter for stars lens and 50%
3mm diameter for mushroom lens),
NOTES :
Light Source to be located in accessible and dry ambience location.
LAMP INFO :
N/A
ATTACHMENTS :
Electrified track made from extruded aluminum. 6 wires are housed in
the track. 4 for three-phase operation, 2 for DALI operation.
The wires are enclosed in rigid extruded profiles made of insulating
material with high dielectric strength
NOTES :
Finishes to be closest colour to RAL ceiling as per ID specification.
Min ingress protection IP20
LAMP INFO :
46 W LED, 30 degree beam angle 5000lm, CRI>80. L80/ B10
50,000h, 2 step MacAdam ellipse to ensure colour consistency
ATTACHMENTS :
To be supplied with antiglare accessory and fixing elements to meet
on site conditions.
NOTES :
Closest available RAL number to match ceiling finish. IP20
LAMP INFO :
46 W LED, 16 degree beam angle 5000lm, CRI>80. L80/ B10
50,000h, 2 step MacAdam ellipse to ensure colour consistency
ATTACHMENTS :
To be supplied with antiglare accessory and fixing elements to meet
on site conditions.
NOTES :
Closest available RAL number to match ceiling finish. IP20
LAMP INFO :
N/A
ATTACHMENTS :
To be supplied with fixing elements to suit on site conditions.
Final specification, ref. to KCA spec 1071_LGT
NOTES :
Track system to be control trough specified lighting control type as
per manufactories recommendation.
LAMP INFO :
LED 3000K
ATTACHMENTS :
To be supplied with fixing elements to suit on site conditions.
Final specification, ref. to KCA spec 1071_LGT
NOTES :
Spotlight within track system to be control trough specified lighting
control type as per manufactories recommendation. Final Qty and
light source to be coordinate with LT PLD.
LAMP INFO :
LED 3000K
ATTACHMENTS :
To be supplied with fixing elements to suit on site conditions.
Final specification, ref. to KCA spec 1071_LGT
NOTES :
Spotlight within track system to be control trough specified lighting
control type as per manufactories recommendation. Final Qty and
light source to be coordinate with LT PLD.
LAMP INFO :
35 W LED, 42 degree beam angle 3000lm, CRI>80. L80/ B10
50,000h, 2 step MacAdam ellipse to ensure colour consistency
ATTACHMENTS :
To be supplied with ceiling mounted base accessory.
NOTES :
Closest available RAL number to match ceiling finish. IP20
LAMP INFO :
N/A
ATTACHMENTS :
Electrified track made from extruded aluminum. 6 wires are housed in
the track. 4 for three-phase operation, 2 for DALI operation.
The wires are enclosed in rigid extruded profiles made of insulating
material with high dielectric strength
NOTES :
Finishes to be closest colour to RAL ceiling as per ID specification.
Min ingress protection IP20
LAMP INFO :
35 W LED, 28 degree beam angle 3000lm, CRI>80. L80/ B10
50,000h
ATTACHMENTS :
To be supplied with ceiling mounted base accessory.
NOTES :
Closest available RAL number to match ceiling finish. IP20
LAMP INFO :
35 W LED, 20 degree beam angle 3000lm, CRI>80. L80/ B10
50,000h
ATTACHMENTS :
To be supplied with ceiling mounted base accessory.
NOTES :
Closest available RAL number to match ceiling finish. IP20
LAMP INFO :
10 W LED, 597 lm, flood optic, Blue LED, CRI>80. L80/ B10
50,000h, 2 step MacAdam ellipse to ensure colour consistency
ATTACHMENTS :
Luminaire to be supplied with relevant fixing elements to suit on site
conditions. electronic drivers (refer to lighting control schedule for
dimming requirement/protocol) to be supplied by manufacturer of light
fixture.
NOTES :
Dark reflector, trim finish to be closest available RAL number to match
ceiling finish, IP20min ingress protection.
LAMP INFO :
18 W LED, 1463lm, 40 degrees beam angle, 3000K, CRI>80. L80/
B10 50,000h, 2 step MacAdam ellipse to ensure colour consistency
ATTACHMENTS :
Luminaire to be supplied with relevant fixing elements to suit on site
conditions. electronic drivers (refer to lighting control schedule for
dimming requirement/protocol) to be supplied by manufacturer of light
fixture.
NOTES :
Dark reflector, trim finish to be closest available RAL number to match
ceiling finish, IP20min ingress protection.
LAMP INFO :
75 W LED,
ATTACHMENTS :
Luminaire to be supplied with relevant fixing elements to suit on site
conditions. electronic component (refer to lighting control schedule
for dimming requirement/protocol) to be supplied by manufacturer of
light fixture.
NOTES :
IP20min ingress protection.
LAMP INFO :
9 W/m, approx. 600 lm/m 4000K
ATTACHMENTS :
To be supplied with fixing elements to suit on site conditions.
NOTES :
Minimal amount of drivers to run the maximum number of LEDs as
per manufacturer’s recommendation. IP68
LAMP INFO :
40 W LED,
ATTACHMENTS :
Luminaire to be supplied with relevant fixing elements to suit on site
conditions. electronic component (refer to lighting control schedule
for dimming requirement/protocol) to be supplied by manufacturer of
light fixture.
NOTES :
IP20min ingress protection.
LAMP INFO :
10 W/m, 290 lm/m 3000k, 3 step MacAdam ellipse to ensure colour
consistency
ATTACHMENTS :
To be supplied with fixing elements to suit on site conditions.
NOTES :
Minimal amount of drivers to run the maximum number of LEDs as
per manufacturer’s recommendation. Min ingress protection IP65
LAMP INFO :
10 W/m, 330 lm/m 3000k, 3 step MacAdam ellipse to ensure colour
consistency
ATTACHMENTS :
To be supplied with fixing elements to suit on site conditions.
NOTES :
Minimal amount of drivers to run the maximum number of LEDs as
per manufacturer’s recommendation. Min ingress protection IP65
LAMP INFO :
5 W/m, 410 lm/m, 3000K, 3 step MacAdam ellipse to ensure colour
consistency
ATTACHMENTS :
Contractor to ensure to supplied with fixing elements to suit on site
conditions.
NOTES :
Minimal amount of drivers to run the maximum number of LEDs as
per manufacturer’s recommendation. Drivers, to be supplied by
manufacturer of light fixture. minimum ingress protection IP65
LAMP INFO :
5 W per sheet, approx. 600 lm/m 4000K
ATTACHMENTS :
To be supplied with fixing elements to suit on site conditions.
NOTES :
Minimal amount of drivers to run the maximum number of LEDs as
per manufacturer’s recommendation. IP20
LED sheet to be cut as per site conditions. To be coordinate with
supplier, to achieve the exact lite panel size.
LAMP INFO :
9.3W LED, 639 lm, Medium optic- 24 degrees 2 step MacAdam
ellipse to ensure colour consistency
ATTACHMENTS :
Luminaire to be supplied with dimmable driver (refer to lighting
control schedule for dimming requirement / protocol) to be supplied by
manufacturer and with relevant fixing elements to suit on site
conditions.
NOTES :
trim and reflector to be closest available RAL number to match ceiling finish,
Minimal amount of drivers to run the maximum number of LEDs as per
manufacturer’s recommendation. Ingress IP23.
LAMP INFO :
11 W LED, 15 degrees beam angle 2 step MacAdam ellipse to ensure
colour consistency
ATTACHMENTS :
luminaire to be supplied with LED driver to run multiple light sources
as per manufacturers recommendations and in line with on site
conditions.
NOTES :
Set back lamp position, finish to be closest available RAL number to
match ceiling finish, dimmable driver. IP20 min ingress protection.
LAMP INFO :
5 W/m, 410 lm/m, 3000K, 3 step MacAdam ellipse to ensure colour
consistency
ATTACHMENTS :
To be supplied with fixing elements to suit on site conditions.
NOTES :
Minimal amount of drivers to run the maximum number of LEDs as
per manufacturer’s recommendation. IP65
LAMP INFO :
Approx 5 W/m, 400 lm/m, 3000K, 3 step MacAdam ellipse to ensure
colour
ATTACHMENTS :
To be supplied with fixing elements to suit on site conditions.
NOTES :
Dot-free light through opal encapsulation. Minimal amount of drivers
to run the maximum number of LEDs as per manufacturer’s
recommendation. Ingress IP67
LAMP INFO :
Approx 2.5 W per sheet, approx. 300 lm/m 3000K
ATTACHMENTS :
To be supplied with fixing elements to suit on site conditions.
NOTES :
Minimal amount of drivers to run the maximum number of LEDs as
per manufacturer’s recommendation. IP20
LED sheet to be cut as per site conditions. To be coordinate with
supplier, to achieve the exact lite panel size.
LAMP INFO :
Approx 5 W/m, 400 lm/m, 3000K, 3 step MacAdam ellipse to ensure
colour
ATTACHMENTS :
To be supplied with fixing elements to suit on site conditions.
NOTES :
Dot-free light through opal encapsulation. Minimal amount of drivers
to run the maximum number of LEDs as per manufacturer’s
recommendation. Ingress IP67
LAMP INFO :
N/A
ATTACHMENTS :
To be supplied with fixing elements to suit on site conditions.
Final specification, ref. to KCA spec 5070_LGT
NOTES :
Track system to be control trough specified lighting control type as
per manufactories recommendation.
LAMP INFO :
LED 3000K
ATTACHMENTS :
To be supplied with fixing elements to suit on site conditions.
Final specification, ref. to KCA spec 5070_LGT
NOTES :
Spotlight within track system to be control trough specified lighting
control type as per manufactories recommendation. Final Qty and
light source to be coordinate with LT PLD.
LAMP INFO :
LED 3000K
ATTACHMENTS :
To be supplied with fixing elements to suit on site conditions.
Final specification, ref. to KCA spec 5070_LGT
NOTES :
Spotlight within track system to be control trough specified lighting
control type as per manufactories recommendation. Final Qty and
light source to be coordinate with LT PLD.
LAMP INFO :
10 W/m, 290 lm/m 3000k, 3 step MacAdam ellipse to ensure colour
consistency
ATTACHMENTS :
To be supplied with fixing elements to suit on site conditions.
NOTES :
Minimal amount of drivers to run the maximum number of LEDs as
per manufacturer’s recommendation. Min ingress protection IP65
LAMP INFO :
18 W LED, 1463lm, 40 degrees beam angle, 3000K, CRI>80. L80/
B10 50,000h, 2 step MacAdam ellipse to ensure colour consistency
ATTACHMENTS :
Luminaire to be supplied with relevant fixing elements to suit on site
conditions. electronic drivers (refer to lighting control schedule for
dimming requirement/protocol) to be supplied by manufacturer of light
fixture.
NOTES :
Dark reflector, trim finish to be closest available RAL number to match
ceiling finish, IP20min ingress protection.
LAMP INFO :
10 W/m, 290 lm/m 3000k, 3 step MacAdam ellipse to ensure colour
consistency
ATTACHMENTS :
To be supplied with fixing elements to suit on site conditions.
NOTES :
Minimal amount of drivers to run the maximum number of LEDs as
per manufacturer’s recommendation. Min ingress protection IP65
LAMP INFO :
15 W/m, approx. 1244 lm/m 3000K 3 step MacAdam ellipse to
ensure colour consistency
ATTACHMENTS :
To be supplied with fixing elements to suit on site conditions.
NOTES :
Minimal amount of drivers to run the maximum number of LEDs as
per manufacturer’s recommendation. IP65
LAMP INFO :
15 W/m, approx. 1244 lm/m 4000K 3 step MacAdam ellipse to
ensure colour consistency
ATTACHMENTS :
To be supplied with fixing elements to suit on site conditions.
NOTES :
Minimal amount of drivers to run the maximum number of LEDs as
per manufacturer’s recommendation. IP65
LAMP INFO :
10 W/m, 290 lm/m 3000k, 3 step MacAdam ellipse to ensure colour
consistency
ATTACHMENTS :
To be supplied with fixing elements to suit on site conditions.
NOTES :
Minimal amount of drivers to run the maximum number of LEDs as
per manufacturer’s recommendation. Min ingress protection IP65
LAMP INFO :
5 W/m, 410 lm/m, 4000K, 3 step MacAdam ellipse to ensure colour
consistency
ATTACHMENTS :
Contractor to ensure to supplied with fixing elements to suit on site
conditions.
NOTES :
Minimal amount of drivers to run the maximum number of LEDs as
per manufacturer’s recommendation. Drivers, to be supplied by
manufacturer of light fixture. minimum ingress protection IP20.
LAMP INFO :
10W/m, 98W max (Pixel distributer & 5 strings)
ATTACHMENTS :
System to be supplied with intelligent software, fixing elements to
meet on site conditions.
NOTES :
Minimal amount of drivers/electrical components to run the maximum
number of LEDs as per manufactures recommendations. minimum
ingress protection IP20.
LAMP INFO :
5 W per sheet, approx. 600 lm/m 5700K
ATTACHMENTS :
To be supplied with fixing elements to suit on site conditions.
NOTES :
Minimal amount of drivers to run the maximum number of LEDs as
per manufacturer’s recommendation. IP20
LED sheet to be cut as per site conditions. To be coordinate with
supplier, to achieve the exact lite panel size.
LAMP INFO :
10 W/m, 290 lm/m 3000k, 3 step MacAdam ellipse to ensure colour
consistency
ATTACHMENTS :
To be supplied with fixing elements to suit on site conditions.
NOTES :
Minimal amount of drivers to run the maximum number of LEDs as
per manufacturer’s recommendation. Min ingress protection IP65
LAMP INFO :
5 W/m, 410 lm/m, 2700K, 3 step MacAdam ellipse to ensure colour
consistency
ATTACHMENTS :
Contractor to ensure to supplied with fixing elements to suit on site
conditions.
NOTES :
Minimal amount of drivers to run the maximum number of LEDs as
per manufacturer’s recommendation. Drivers, to be supplied by
manufacturer of light fixture. minimum ingress protection IP20.
LAMP INFO :
10 W/m, 290 lm/m 3000k, 3 step MacAdam ellipse to ensure colour
consistency
ATTACHMENTS :
To be supplied with fixing elements to suit on site conditions.
NOTES :
Minimal amount of drivers to run the maximum number of LEDs as
per manufacturer’s recommendation. Min ingress protection IP65
LAMP INFO :
3 W LED, 345 lm 3000K wall washer optic 2 step MacAdam ellipse
to ensure colour consistency
ATTACHMENTS :
To be supplied with fixing elements to meet on site conditions.
NOTES :
Diffuser glass, round shape. Minimal amount of drivers to run the
maximum number of LEDs as per manufacturer’s recommendation.
Ingress IP68
LAMP INFO :
N/A
ATTACHMENTS :
Electrified track made from extruded aluminum. 6 wires are housed in
the track. 4 for three-phase operation, 2 for DALI operation.
The wires are enclosed in rigid extruded profiles made of insulating
material with high dielectric strength
NOTES :
Finishes to be closest colour to RAL ceiling as per ID specification.
Min ingress protection IP20
LAMP INFO :
35 W LED, 28 degree beam angle 3000lm, CRI>80. L80/ B10
50,000h
ATTACHMENTS :
To be supplied with ceiling mounted base accessory.
NOTES :
Closest available RAL number to match ceiling finish. IP20
LAMP INFO :
1W LED, 17lm 4000K 2 step MacAdam ellipse to ensure colour
consistency
ATTACHMENTS :
To be supplied with fixing elements to meet on site conditions.
NOTES :
Diffuser glass, round shape. Minimal amount of drivers to run the
maximum number of LEDs as per manufacturer’s recommendation.
Ingress IP67
LAMP INFO :
5W 360lm 3000K, medium beam angle, 3 step MacAdam ellipse to
ensure colour consistency
ATTACHMENTS :
To be supplied with visor for glare protection, spike for soft landscape
installation and all fixing elements to suit on site conditions.
NOTES :
Remote driver to be located within an accessible, temperature
controlled dislocation within a distance as per manufactures
recommendations (refer to lighting control schedule for dimming
requirement/protocol ). IP65 min ingress protection.
LAMP INFO :
N/A
ATTACHMENTS :
Electrified track made from extruded aluminum. 6 wires are housed in
the track. 4 for three-phase operation, 2 for DALI operation.
The wires are enclosed in rigid extruded profiles made of insulating
material with high dielectric strength
NOTES :
Finishes to be closest colour to RAL ceiling as per ID specification.
Min ingress protection IP20
LAMP INFO :
35 W LED, 28 degree beam angle 3000lm, CRI>80. L80/ B10
50,000h
ATTACHMENTS :
To be supplied with ceiling mounted base accessory.
NOTES :
Closest available RAL number to match ceiling finish. IP20
LAMP INFO :
46 W LED, 30 degree beam angle 5000lm, CRI>80. L80/ B10
50,000h, 2 step MacAdam ellipse to ensure colour consistency
ATTACHMENTS :
To be supplied with antiglare accessory and fixing elements to meet
on site conditions.
NOTES :
Closest available RAL number to match ceiling finish. IP20
LAMP INFO :
46 W LED, 16 degree beam angle 5000lm, CRI>80. L80/ B10
50,000h, 2 step MacAdam ellipse to ensure colour consistency
ATTACHMENTS :
To be supplied with antiglare accessory and fixing elements to meet
on site conditions.
NOTES :
Closest available RAL number to match ceiling finish. IP20
LAMP INFO :
46 W LED, 48 degree beam angle 5000lm, CRI>80. L80/ B10
50,000h, 2 step MacAdam ellipse to ensure colour consistency
ATTACHMENTS :
To be supplied with antiglare accessory and fixing elements to meet
on site conditions.
NOTES :
Closest available RAL number to match ceiling finish. IP20
7000
MOUNTING :
Custom fixture
LAMP INFO :
5 W/m 160 lm/m approx. 4000K
ATTACHMENTS :
T.B.C
NOTES :
Tree Of Life - Front Panel made in custom made dimmable
encapsulated linear LED, various length, mounted within
custom made aluminum track. IP20 min ingress
2400 mm protection.
LAMP INFO :
Approx. 380 W LED
ATTACHMENTS :
T.B.C
NOTES :
Nano-technology based system capable of artificially
reproducing the natural light and the visual appearance of
the sun and sky.
LAMP INFO :
1W LED, 17lm 3000K 2 step MacAdam ellipse to ensure colour
consistency
ATTACHMENTS :
To be supplied with fixing elements to meet on site conditions.
NOTES :
Round shape. Minimal amount of drivers to run the maximum number
of LEDs as per manufacturer’s recommendation. Ingress IP67
LAMP INFO :
10W/m, 98W max (Pixel distributer & 5 strings)
ATTACHMENTS :
System to be supplied with intelligent software, fixing elements to
meet on site conditions.
NOTES :
Minimal amount of drivers/electrical components to run the maximum
number of LEDs as per manufactures recommendations. minimum
ingress protection IP20.
LAMP INFO :
14.4 W/m, 1260 lm/m, 3000K 3 step MacAdam ellipse to ensure
colour consistency
ATTACHMENTS :
To be supplied with fixing elements to suit on site conditions.
NOTES :
Minimal amount of drivers to run the maximum number of LEDs as
per manufacturer’s recommendation. Min ingress protection IP65
LAMP INFO :
10W/m, 98W max (Pixel distributer & 5 strings)
ATTACHMENTS :
System to be supplied with intelligent software, fixing elements to
meet on site conditions.
NOTES :
Minimal amount of drivers/electrical components to run the maximum
number of LEDs as per manufactures recommendations. minimum
ingress protection IP20.
LAMP INFO :
10 W/m, 290 lm/m 4000k, 3 step MacAdam ellipse to ensure colour
consistency
ATTACHMENTS :
To be supplied with fixing elements to suit on site conditions.
NOTES :
Minimal amount of drivers to run the maximum number of LEDs as
per manufacturer’s recommendation. Min ingress protection IP65
LAMP INFO :
14.4 W/m, 1260 lm/m, 3000K 3 step MacAdam ellipse to ensure
colour consistency
ATTACHMENTS :
To be supplied with fixing elements to suit on site conditions.
NOTES :
Minimal amount of drivers to run the maximum number of LEDs as
per manufacturer’s recommendation. Min ingress protection IP65
LAMP INFO :
5 W/m, 410 lm/m, 2700K 3 step MacAdam ellipse to ensure colour
consistency
ATTACHMENTS :
To be supplied with fixing elements to suit on site conditions.
NOTES :
Minimal amount of drivers to run the maximum number of LEDs as
per manufacturer’s recommendation. Min ingress protection IP20
LAMP INFO :
10 W/m, 170 lm/m 2700k 3 step MacAdam ellipse to ensure colour
consistency
ATTACHMENTS :
To be supplied with fixing elements to suit on site conditions.
NOTES :
Minimal amount of drivers to run the maximum number of LEDs as
per manufacturer’s recommendation. Min ingress protection IP20
LAMP INFO :
14.4 W/m, 1260 lm/m, 2700K 3 step MacAdam ellipse to ensure
colour consistency
ATTACHMENTS :
To be supplied with fixing elements to suit on site conditions.
NOTES :
Minimal amount of drivers to run the maximum number of LEDs as
per manufacturer’s recommendation. Min ingress protection IP65
LAMP INFO :
10W/m, 98W max (Pixel distributer & 5 strings)
ATTACHMENTS :
System to be supplied with intelligent software, fixing elements to
meet on site conditions.
NOTES :
Minimal amount of drivers/electrical components to run the maximum
number of LEDs as per manufactures recommendations. minimum
ingress protection IP20.
LAMP INFO :
11 W/m, 310 lm/m RGB, 3 step MacAdam ellipse to ensure colour
consistency
ATTACHMENTS :
To be supplied with fixing elements to suit on site conditions.
NOTES :
Minimal amount of drivers to run the maximum number of LEDs as
per manufacturer’s recommendation. Min ingress protection IP65
LAMP INFO :
1.5 W/ module, 130 lm/W LED 3000K . 3 step MacAdam ellipse to
ensure colour consistency
ATTACHMENTS :
CREE XP-E2 LED point source illumination cut-out diameter X19mm
available for tubes with outer diameter X40mm to X60mm, including
silicone gasket, protected fully selective conformal coated optical
silicone PCB MCB copper board, encapsulated with very good thermal
connection to the Aluminium metal core board (MCB 1.5mm) and
internal heatsink ,
continues endless electrical feed through wiring plugand- play
NOTES :
Remote dimmable LED driver as per manufactory recommendations..
Manufacturer MUST submit technical submittal documentation, compliance
statement and samples to LT PLD for approval prior to full production. Mock-up
required for final LT PLD, KCA and contractor’s installation quality and fixture
approval upon procurement.
MOUNTING :
Ceiling recessed Linear LED fitting
LAMP INFO :
16 W/m, 330 lm/m, BLUE LED, 3 step MacAdam ellipse to ensure
colour
ATTACHMENTS :
To be supplied with fixing elements to suit on site conditions.
NOTES :
Custom made recessed trim less aluminum track “C” shape, with
opal semi translucent sealed encapsulation. Minimal amount of
drivers to run the maximum number of LEDs as per manufacturer’s
recommendation. Ingress IP67
“C” Track lengths = 700x1200x700 mm
LAMP INFO :
10 W/m, 290 lm/m 2700k, 3 step MacAdam ellipse to ensure colour
consistency
ATTACHMENTS :
To be supplied with fixing elements to suit on site conditions.
NOTES :
Minimal amount of drivers to run the maximum number of LEDs as
per manufacturer’s recommendation. Min ingress protection IP65
LAMP INFO :
5 W/m, 410 lm/m, 3000K, 3 step MacAdam ellipse to ensure colour
consistency
ATTACHMENTS :
Contractor to ensure to supplied with fixing elements to suit on site
conditions.
NOTES :
Minimal amount of drivers to run the maximum number of LEDs as
per manufacturer’s recommendation. Drivers, to be supplied by
manufacturer of light fixture. minimum ingress protection IP65.
LAMP INFO :
16 W/m, 330 lm/m, BLUE LED, 3 step MacAdam ellipse to ensure
colour
ATTACHMENTS :
To be supplied with fixing elements to suit on site conditions.
NOTES :
Linear LED within trim less aluminum track, with opal semi
translucent sealed encapsulation. Minimal amount of drivers to run
the maximum number of LEDs as per manufacturer’s
recommendation. Ingress IP67
LAMP INFO :
5 W per sheet, approx. 600 lm/m 3500K
ATTACHMENTS :
To be supplied with fixing elements to suit on site conditions.
NOTES :
Minimal amount of drivers to run the maximum number of LEDs as
per manufacturer’s recommendation. IP20
LED sheet to be cut as per site conditions. To be coordinate with
supplier, to achieve the exact lite panel size.
LAMP INFO :
13 W/m, 763 lm 3000K 48 degree beam angle, CRI>80. L80/ B10
50,000h, 2 step MacAdam ellipse to ensure colour consistency
ATTACHMENTS :
Luminaire to be supplied with relevant fixing elements to suit on site
conditions. electronic drivers (refer to lighting control schedule for
dimming requirement/protocol) to be supplied by manufacturer of light
fixture.
NOTES :
Fixed, reflector and trim finish to be closest available RAL number to match
ceiling finish. Passive heat dissipation system. Metalized, thermoplastic, high
definition optic, integrated in a rear position in the anti-glare screen. Glass
cover for LED lamp. IP20min ingress protection.
Manufacturer MUST submit technical submittal documentation, compliance
statement and samples to LT PLD for approval prior to full production. Mock-up
required for final LT PLD, KCA and contractor’s installation quality and fixture
approval upon procurement.
LAMP INFO :
13 W/m, 763 lm 3000K 12 degree beam angle, CRI>80. L80/ B10
50,000h, 2 step MacAdam ellipse to ensure colour consistency
ATTACHMENTS :
Luminaire to be supplied with relevant fixing elements to suit on site
conditions. electronic drivers (refer to lighting control schedule for
dimming requirement/protocol) to be supplied by manufacturer of light
fixture.
NOTES :
Fixed, reflector and trim finish to be closest available RAL number to match
ceiling finish. Passive heat dissipation system. Metalized, thermoplastic, high
definition optic, integrated in a rear position in the anti-glare screen. Glass
cover for LED lamp. IP20min ingress protection.
Manufacturer MUST submit technical submittal documentation, compliance
statement and samples to LT PLD for approval prior to full production. Mock-up
required for final LT PLD, KCA and contractor’s installation quality and fixture
approval upon procurement.
LAMP INFO :
13 W/m, 763 lm 3000K 34 degree beam angle, CRI>80. L80/ B10
50,000h, 2 step MacAdam ellipse to ensure colour consistency
ATTACHMENTS :
Luminaire to be supplied with relevant fixing elements to suit on site
conditions. electronic drivers (refer to lighting control schedule for
dimming requirement/protocol) to be supplied by manufacturer of light
fixture.
NOTES :
Fixed, reflector and trim finish to be closest available RAL number to match
ceiling finish. Passive heat dissipation system. Metalized, thermoplastic, high
definition optic, integrated in a rear position in the anti-glare screen. Glass
cover for LED lamp. IP20min ingress protection.
Manufacturer MUST submit technical submittal documentation, compliance
statement and samples to LT PLD for approval prior to full production. Mock-up
required for final LT PLD, KCA and contractor’s installation quality and fixture
approval upon procurement.
LAMP INFO :
10 W LED, 1050 lm, 25 degree beam angle optic, 2700K, CRI>90.
L80/ B10 50,000h, 2 step MacAdam ellipse to ensure colour
consistency
ATTACHMENTS :
Luminaire to be supplied with relevant fixing elements to suit on site
conditions. electronic drivers (refer to lighting control schedule for
dimming requirement/protocol) to be supplied by manufacturer of light
fixture.
NOTES :
Reflector to be satin gold finish and trim finish to be closest available RAL
number to match ceiling finish., IP20min ingress protection.
LAMP INFO :
10 W LED, 1050 lm, 42 degree beam angle optic, 2700K, CRI>90.
L80/ B10 50,000h, 2 step MacAdam ellipse to ensure colour
consistency
ATTACHMENTS :
Luminaire to be supplied with relevant fixing elements to suit on site
conditions. electronic drivers (refer to lighting control schedule for
dimming requirement/protocol) to be supplied by manufacturer of light
fixture.
NOTES :
Reflector to be satin gold finish and trim finish to be closest available RAL
number to match ceiling finish, IP20min ingress protection.
LAMP INFO :
6 W LED, 825 lm, wide flood optic, 3000K, CRI>80. L80/ B10
50,000h, 2 step MacAdam ellipse to ensure colour consistency
ATTACHMENTS :
Luminaire to be supplied with relevant fixing elements to suit on site
conditions. electronic drivers (refer to lighting control schedule for
dimming requirement/protocol) to be supplied by manufacturer of light
fixture.
NOTES :
Dark reflector, trim finish to be closest available RAL number to match
ceiling finish, IP20min ingress protection.
LAMP INFO :
18 W LED, 1463lm, 40 degrees beam angle, 3000K, CRI>80. L80/
B10 50,000h, 2 step MacAdam ellipse to ensure colour consistency
ATTACHMENTS :
Luminaire to be supplied with relevant fixing elements to suit on site
conditions. electronic drivers (refer to lighting control schedule for
dimming requirement/protocol) to be supplied by manufacturer of light
fixture.
NOTES :
Dark reflector, trim finish to be closest available RAL number to match
ceiling finish, IP20min ingress protection.
LAMP INFO :
6 W LED, 825 lm, wide flood optic, 3000K, CRI>80. L80/ B10
50,000h, 2 step MacAdam ellipse to ensure colour consistency
ATTACHMENTS :
Luminaire to be supplied with relevant fixing elements to suit on site
conditions. electronic drivers (refer to lighting control schedule for
dimming requirement/protocol) to be supplied by manufacturer of light
fixture.
NOTES :
Dark reflector, trim finish to be closest available RAL number to match
ceiling finish, IP20min ingress protection.
• All stated dimensions / length of product are subject to change due to on site conditions.
• All expressed product references, names, types , codes, attachments etc… are for reference only are to be confirmed by the
contractor with the referred manufacturer prior to ordering.
• All specified products are specified based on an equal or approved based. Approval of an alternative product will be subject to providing
photometric date, working sample and the relevant lighting calculations to confirm that the alternative can meet the required design
criteria.
• All manufacturers must guarantee tooling for each specified product for a minimum of ten years for production of spares.
• Control Gear , Ballast, transformers & LED drivers are to be supplied by the manufacturer of the product, unless written approval by
the manufacturer has been made for each product type for the contractor to provide alternative bands.
• The contractor must ensure all relevant fixing elements, installation housings, and tools are to be supplied with the product in
conjunction with manufacturers recommendations.
• The contractor must ensure compatibility of the product with respect to the lighting control system / building management system or
room management system with respect to lighting control, switching capability and dimming.
• Emergency lighting has been deemed as part of the electrical consultants package, for maintained & non-maintained light fixtures, the
contractor must ensure the relevant conversion pack, relays and modules are supplied and are compatible to the emergency lighting
system. The system must meet with local recommendations and codes of practice.
• The proposed and specified emergency lighting strategy and product specification must be presented to the lighting designer for
review, comment and approval.
• We would recommend 5% spare fixtures to be supplied for each product and 10% lamps pending client approval. Decorative, individual
units and bespoke items are excluded pending specific approval from design team and client.
• A minimum 5 year guarantee for LED fixtures is to be offered to client, and 1 year guarantee for all other fixture types.
• The contractor must ensure all product is installed as per manufacturers guidelines.
• A mock up of each product type is required prior to completing the full installation and is to be reviewed and approved by a member of
the Lighting Design team, unless otherwise instructed.