You are on page 1of 30

S1

DESIGN OF SLAB

Ly = 4.29 m

Lx = 4.19 m

Design Slab As Two way slab

Effective Depth of Slab

d = 106.887755102 mm

D = 126.887755102 mm

Assume D = 110 mm

d = 90 mm

LOADING

Self wt. of slab = 2.75 KN/m

Floor finish load = 1.25 KN/m

Live load = 2 KN/m

Total Load = 6 KN/m

Ultimate load = 9 KN/m

Consider :- Two adjacent edge discontinuous

BM coefficient

αx(-ve) = 0.0485

αx(+ve) = 0.0362

αy(-ve) = 0.047

αy(+ve) = 0.035

BENDING MOMENT = α x w x (Lx)^2

Mx (-ve) = 7.66323765 KN.m

Mx (+ve) = 5.71977738 KN.m

My (-ve) = 7.4262303 KN.m


My (+ve) = 5.5301715 KN.m

Mu Max = 0.138*fck*b*d*d

7663237.65 = 0.138*25*1000 *d*d

d = 46.84 mm safe

AST REQUIRED

Astrequired = 0.5 fck 1 - 1 - 4.6 Mu b d


Fy Fck b d2

Ast x (-ve) = 247.222837882 mm^2

USE 8 mm Dia Bar

SPACING = 203.217471454 mm

provide 8 mm dia @ 200 mm c/c.

Ast x (+ve) = 182.236367384 mm^2

SPACING = 275.685916709 mm

provide 8 mm dia @ 250 mm c/c.

Ast Y (-ve) = 239.206174792 mm^2

SPACING = 210.02802308 mm

provide 8 mm dia @ 200 mm c/c.

Ast x (+ve) = 175.985422806 mm^2

SPACING = 285.478190175 mm

provide 8 mm dia @ 250 mm c/c.

DISTRIBUTION STEEL

Ast min = 0.12%bD


= 132 mm^2

SPACING = 380.606060606 mm

provide 8 mm dia @ 350 mm c/c.

TORSION STEEL

= 3/4 X Ast x (+ve)

= 136.677275538 mm^2

SPACING = 367.581222279 mm

provide 8 mm dia @ 350 mm c/c.

EDGE STRIP STEEL


= 0.12 X Bd
100

= 132 mm^2

SPACING = 380.606060606 mm

ASSUME 0.3% OF STEEL

% OF STEEL = 0.2247480344 SAFE

CHECK FOR DEFLECTION

Fs = 0.58 fy x Ast Max


Ast provided

= 236.889080725 mm

M.F. 1.55<1.4 SAFE

CHECK FOR DEVELOPMENT LENGTH

Ld<1.3 M1/v + lo = lo = 165


M1= 3831618.825
v= 22.626 kn
376 < 385.149583333 SAFE
S2
DESIGN OF SLAB

Ly = 5.19 m

Lx = 3.39 m

Design Slab As Two way slab

Effective Depth of Slab

d = 86.4795918367 mm

D = 106.4795918367 mm

Assume D = 110 mm

d = 90 mm

LOADING

Self wt. of slab = 2.75 KN/m

Floor finish load = 1.25 KN/m

Live load = 2 KN/m

Total Load = 6 KN/m

Ultimate load = 9 KN/m

Consider :- Two adjacent edge discontinuous

BM coefficient

αx(-ve) = 0.078

αx(+ve) = 0.058

αy(-ve) = 0.047

αy(+ve) = 0.035

BENDING MOMENT = α x w x (Lx)^2

Mx (-ve) = 8.0674542 KN.m

Mx (+ve) = 5.9988762 KN.m

My (-ve) = 4.8611583 KN.m


My (+ve) = 3.6200115 KN.m

Mu Max = 0.138*fck*b*d*d

8067454.2 = 0.138*25*1000 *d*d

d = 48.356 mm safe

AST REQUIRED

Astrequired = 0.5 fck 1 - 1 - 4.6 Mu


Fy Fck b d2

Ast x (-ve) = 260.955795162 mm^2

USE 8 mm Dia Bar

SPACING = 192.5230285413 mm

provide 8 mm dia @ 200 mm c/c.

Ast x (+ve) = 191.4659412207 mm

SPACING = 262.3965373668 mm

provide 8 mm dia @ 250 mm c/c.

Ast Y (-ve) = 154.0514243656 mm^2

SPACING = 326.124865167 mm

provide 8 mm dia @ 200 mm c/c.

Ast x (+ve) = 113.8502716554 mm^2

SPACING = 441.2813361752 mm

provide 8 mm dia @ 250 mm c/c.

DISTRIBUTION STEEL

Ast min = 0.12%bD


= 132 mm^2

SPACING = 380.6060606061 mm

provide 8 mm dia @ 350 mm c/c.

TORSION STEEL

= 3/4 X Ast x (+ve)

= 143.5994559156 mm^2

SPACING = 349.8620498224 mm

provide 8 mm dia @ 350 mm c/c.

EDGE STRIP STEEL


= 0.12 X Bd
100

= 132 mm^2

SPACING = 380.6060606061 mm

provide 8 mm dia @ 350 mm c/c.

ASSUME 0.3% OF STEEL

% OF STEEL = 0.2372325411 SAFE

CHECK FOR DEFLECTION

Fs = 0.58 fy x Ast Max


Ast provided

= 250.0480091381 mm

M.F. 1.55<1.4 SAFE

CHECK FOR DEVELOPMENT LENGTH

Ld<1.3 M1/v + lo = lo = 165 mm


M1= 4033727.1
v= 18.306 kn
376 < 451.455 SAFE
b d
S4
DESIGN OF SLAB

Ly = 5.99 m

Lx = 3.79 m

Design Slab As Two way slab

Effective Depth of Slab

d = 96.6836734694 mm

D = 116.6836734694 mm

Assume D = 110 mm

d = 90 mm

LOADING

Self wt. of slab = 2.75 KN/m

Floor finish load = 1.25 KN/m

Live load = 2 KN/m

Total Load = 6 KN/m

Ultimate load = 9 KN/m

Consider :- Two adjacent edge discontinuous

BM coefficient

αx(-ve) = 0.06

αx(+ve) = 0.048

αy(-ve) = 0.037

αy(+ve) = 0.028

BENDING MOMENT = α x w x (Lx)^2

Mx (-ve) = 7.756614 KN.m

Mx (+ve) = 6.2052912 KN.m

My (-ve) = 4.7832453 KN.m


My (+ve) = 3.6197532 KN.m

Mu Max = 0.138*fck*b*d*d

7756614 = 0.138*25*1000 *d*d

d = 47.41 mm safe

AST REQUIRED

Astrequired = 0.5 fck 1 - 1 - 4.6 Mu


Fy Fck b d2

Ast x (-ve) = 250.3884219184 mm^2

USE 8 mm Dia Bar

SPACING = 200.648255279 mm

provide 8 mm dia @ 200 mm c/c.

Ast x (+ve) = 198.31372907 mm^2

SPACING = 253.3359653697 mm

provide 8 mm dia @ 250 mm c/c.

Ast Y (-ve) = 151.5092206908 mm^2

SPACING = 331.5969798467 mm

provide 8 mm dia @ 200 mm c/c.

Ast x (+ve) = 113.8419700024 mm^2

SPACING = 441.3135155597 mm

provide 8 mm dia @ 250 mm c/c.

DISTRIBUTION STEEL

Ast min = 0.12%bD


= 132 mm^2

SPACING = 380.6060606061 mm

provide 8 mm dia @ 350 mm c/c.

TORSION STEEL

= 3/4 X Ast x (+ve)

= 148.7352968025 mm^2

SPACING = 337.7812871596 mm

provide 8 mm dia @ 350 mm c/c.

EDGE STRIP STEEL


= 0.12 X Bd
100

= 132 mm^2

SPACING = 380.6060606061 mm

ASSUME 0.3% OF STEEL

% OF STEEL = 0.2276258381 SAFE

CHECK FOR DEFLECTION

Fs = 0.58 fy x Ast Max


Ast provided

= 239.9223453653 mm

M.F. 1.55<1.4 SAFE

CHECK FOR DEVELOPMENT LENGTH

Ld<1.3 M1/v + lo = lo = 165


M1= 3878307
v= 20.466 kn
376 < 411.35 SAFE
b d
S5
DESIGN OF SLAB

Ly = 2.95 m

Lx = 2.49 m

Design Slab As Two way slab

Effective Depth of Slab

d = 63.5204081633 mm

D = 83.5204081633 mm

Assume D = 110 mm

d = 90 mm

LOADING

Self wt. of slab = 2.75 KN/m

Floor finish load = 1.25 KN/m

Live load = 2 KN/m

Total Load = 6 KN/m

Ultimate load = 9 KN/m

Consider :- Two adjacent edge discontinuous

BM coefficient

αx(-ve) = 0.05

αx(+ve) = 0.036

αy(-ve) = 0.037

αy(+ve) = 0.028

BENDING MOMENT = α x w x (Lx)^2

Mx (-ve) = 2.790045 KN.m

Mx (+ve) = 2.0088324 KN.m

My (-ve) = 2.0646333 KN.m


My (+ve) = 1.5624252 KN.m

Mu Max = 0.138*fck*b*d*d

2790045 = 0.138*25*1000 *d*d

d = 28.43 mm safe

AST REQUIRED

Astrequired = 0.5 fck 1 - 1 - 4.6 Mu


Fy Fck b d2

Ast x (-ve) = 87.3110608254 mm^2

USE 8 mm Dia Bar

SPACING = 575.4139226469 mm

provide 8 mm dia @ 200 mm c/c.

Ast x (+ve) = 62.5737883467 mm^2

SPACING = 802.8920947162 mm

provide 8 mm dia @ 250 mm c/c.

Ast Y (-ve) = 64.3330682777 mm^2

SPACING = 780.9358599713 mm

provide 8 mm dia @ 200 mm c/c.

Ast x (+ve) = 48.5414004608 mm^2

SPACING = 1034.9928004353 mm

provide 8 mm dia @ 250 mm c/c.

DISTRIBUTION STEEL

Ast min = 0.12%bD


= 132 mm^2

SPACING = 380.6060606061 mm

provide 8 mm dia @ 350 mm c/c.

TORSION STEEL

= 3/4 X Ast x (+ve)

= 46.93034126 mm^2

SPACING = 1070.522792955 mm

provide 8 mm dia @ 350 mm c/c.

EDGE STRIP STEEL


= 0.12 X Bd
100

= 132 mm^2

SPACING = 380.6060606061 mm

ASSUME 0.3% OF STEEL

% OF STEEL = 0.0793736917 SAFE

CHECK FOR DEFLECTION

Fs = 0.58 fy x Ast Max


Ast provided

= 83.661514095 mm

M.F. 1.55<1.4 SAFE

CHECK FOR DEVELOPMENT LENGTH

Ld<1.3 M1/v + lo = lo = 165


M1= 2232036
v= 13.446 kn
376 < 380.8 SAFE
b d
S6
DESIGN OF SLAB

Ly = 2.98 m

Lx = 1.99 m

Design Slab As Two way slab

Effective Depth of Slab

d = 50.7653061224 mm

D = 70.7653061224 mm

Assume D = 110 mm

d = 90 mm

LOADING

Self wt. of slab = 2.75 KN/m

Floor finish load = 1.25 KN/m

Live load = 2 KN/m

Total Load = 6 KN/m

Ultimate load = 9 KN/m

Consider :- one long edge discontinuous

BM coefficient

αx(-ve) = 0.066

αx(+ve) = 0.05

αy(-ve) = 0.037

αy(+ve) = 0.028

BENDING MOMENT = α x w x (Lx)^2

Mx (-ve) = 2.3522994 KN.m

Mx (+ve) = 1.782045 KN.m

My (-ve) = 1.3187133 KN.m


My (+ve) = 0.9979452 KN.m

Mu Max = 0.138*fck*b*d*d

2352299.4 = 0.138*25*1000 *d*d

d = 22.38 mm safe

AST REQUIRED

Astrequired = 0.5 fck 1 - 1 - 4.6 Mu


Fy Fck b d2

Ast x (-ve) = 73.4211679019 mm^2

USE 8 mm Dia Bar

SPACING = 684.2713271345 mm

provide 8 mm dia 200 mm c/c.

Ast x (+ve) = 55.4356742218 mm^2

SPACING = 906.2756195407 mm

provide 8 mm dia @ 250 mm c/c.

Ast Y (-ve) = 40.9116696142 mm^2

SPACING = 1228.0114811674 mm

provide 8 mm dia @ 200 mm c/c.

Ast x (+ve) = 30.9026992048 mm^2

SPACING = 1625.7479538278 mm

provide 8 mm dia @ 250 mm c/c.

DISTRIBUTION STEEL

Ast min = 0.12%bD


= 132 mm^2

SPACING = 380.6060606061 mm

provide 8 mm dia @ 350 mm c/c.

TORSION STEEL

= 3/4 X Ast x (+ve)

= 41.5767556663 mm^2

SPACING = 1208.3674927209 mm

provide 8 mm dia @ 350 mm c/c.

EDGE STRIP STE


= 0.12 X Bd
100

= 132 mm^2

SPACING = 380.6060606061 mm

ASSUME 0.3% OF STEEL

% OF STEEL = 0.0667465163 SAFE

CHECK FOR DEFLECTION

Fs = 0.58 fy x Ast Max


Ast provided

= 70.3522098487 mm

M.F. 1.55<1.4 SAFE

CHECK FOR DEVELOPMENT LENGTH

Ld<1.3 M1/v + = lo = 165


M1= 1764224.55
v= 10.746 kn
376 < 378.4275 SAFE
b d
S3 (a)
DESIGN OF SLAB

Ly = 2.79 m

Lx = 1.55 m

Design Slab As One Way slab

Effective Depth of Slab

d = 39.5408163265 mm

D = 59.5408163265 mm

Assume D = 110 mm

d = 90 mm

LOADING

Self wt. of slab = 2.75 KN/m

Floor finish load = 1.25 KN/m

Live load = 2 KN/m

Total Load = 6 KN/m

Ultimate load = 9 KN/m

DESIGN MOMENTS

M = Wl^2/8

= 2.7028125 Kn.m

Mu Max = 0.138*fck*b*d*d

2702812.5 = 0.138*25*1000 *d*d

d = 27.98 mm safe

AST REQUIRED

Astrequired = 0.5 fck 1 - 1 - 4.6 Mu b d


Fy Fck b d2

Ast = 84.5372678881 mm^2

USE 8 mm Dia Bar

SPACING = 300 mm

DISTRIBUTION STEEL

Ast min = 0.12%bD

= 132 mm^2

SPACING = 380.606060606 mm

provide 8 mm dia @ 300 mm c/c.

CHECK FOR DEVELOPMENT LENGTH

Ld<1.3 M1/v + lo = 165


M1= 1520250
v= 8.37 kn

376 < 401.120071685 SAFE


S3 (B)
DESIGN OF SLAB

Ly = 2.49 m

Lx = 1.45 m

Design Slab As One Way slab

Effective Depth of Slab

d = 36.9897959184 mm

D = 56.9897959184 mm

Assume D = 110 mm

d = 90 mm

LOADING

Self wt. of = 2.75 KN/m

Floor finish = 1.25 KN/m

Live load = 2 KN/m

Total Load = 6 KN/m

Ultimate lo = 9 KN/m

DESIGN MOMENTS

M = Wl^2/8

= 2.3653125 Kn.m

Mu Max = 0.138*fck*b*d*d

2365313 = 0.138*25*1000 *d*d

d = 26.15 mm safe

AST REQUIRED

Astrequired = 0.5 fck 1 - 1 - 4.6 Mu b d


Fy Fck b d2

Ast = 73.8330251179 mm^2

USE 8 mm Dia Bar

SPACING = 300 mm

DISTRIBUTION STEEL

Ast min = 0.12%bD

= 132 mm^2

SPACING = 380.6060606061 mm

provide 8 mm dia @ 300 mm c/c.

CHECK FOR DEVELOPMENT LENGTH

Ld<1.3 M1/v + lo = 165


M1= 1327500
v= 7.83 kn

376 < 385.4022988506 SAFE


S3 (C)
DESIGN OF SLAB

Ly = 1.95 m

Lx = 1.55 m

Design Slab As One Way slab

Effective Depth of Slab

d = 39.5408163265 mm

D = 59.5408163265 mm

Assume D = 110 mm

d = 90 mm

LOADING

Self wt. of = 2.75 KN/m

Floor finish = 1.25 KN/m

Live load = 2 KN/m

Total Load = 6 KN/m

Ultimate lo = 9 KN/m

DESIGN MOMENTS

M = Wl^2/8

= 2.7028125 Kn.m

Mu Max = 0.138*fck*b*d*d

2702813 = 0.138*25*1000 *d*d

d = 27.98 mm safe

AST REQUIRED

Astrequired = 0.5 fck 1 - 1 - 4.6 Mu b d


Fy Fck b d2

Ast = 84.5372678881 mm^2

USE 8 mm Dia Bar

SPACING = 300 mm

DISTRIBUTION STEEL

Ast min = 0.12%bD

= 132 mm^2

SPACING = 380.6060606061 mm

provide 8 mm dia @ 300 mm c/c.

CHECK FOR DEVELOPMENT LENGTH

Ld<1.3 M1/v + lo = 165


M1= 1515000
v= 8.37 kn

376 < 400.3046594982 SAFE