SHELL TUBES

Thermal fluid 110m3/h FLUID Thermal fluid Sea Water


FLUID FLOW 110 36 m3/h
Connection DN DN150 DIN 86030 DN100-DIN86030
TEMP. IN 260 10 °C
TEMP. OUT 210 80 °C
DESIGN TEMP. 300 100 °C
1756 DESIGN PRES. 12 12 BARG
TEST PRES 24 24 BARG
1100 CONTENT 56 31 LTR.
MATERIAL C.Steel CuNi 70/30
471 975 WEIGHT EMPTY 456 KG
DELIVERY EXCL. INSULATION
CAPACITY 3000 KW
250
DN150-PN16
250
DN100-PN16
334

Sea Water
90 90

Ø323.9
36m3/h
250
334

1/2"BSP
371 125 220
DN25-PN16 280
Aalborg Projectno. Newbuilding Yard
PP08.200639A.00 44 Gisan Shipyard
Principal : Gemini Denta Gemi Insaa
Nameplate side
Nakliye Isletme Tic. AS
At : Okmeydani - Istanbul - Turkey
The minimum withdrawal
length of heater insert, is: CLASS : Bureau Veritas + AUT-UMS
length of tubes + shell Foundation
diameter. details
Tank cleaning heater
Holes 26x18
19
REV. DESCRIPTION NAME DATE MC30 T12 L=1200
23
Withdrawal length ∅18 for sway bracing PROJECTION DRAWN: AJ DRAWING No: REVISION SHEET
65
SCALE: none 1
The tolerance class in accordance with ISO 2768-1 c OF 1
D85773 0
Toleranceklasse ifølge DS/ISO 2768-1 c
DATE: 04-06-2008
PO Box 145, 3200 AC Spijkenisse, The Netherlands THIS DRAWING AND DESIGN SHOWN
Tel : +31 181 650 500 HEREIN IS THE PROPERTY OF AALBORG
Fax : +31 181 650 501
THERMAL FLUID
INDUSTRIES AND MUST NOT BE USED
E-mail : rtmw@aalborg-industries.nl BY OR REPRODUCED FOR THIRD PARTY
HEAT TECHNOLOGY A3