USB Virtual Oscilloscope

Model:ISDS205A

Electronics Katrangi Trading

www.ekt2.com
ISDS205

1.Introduction
ISDS205 dual-channel digital oscilloscope, with "low-cost, high-performance"
as the design goals. well-designed bandwidth of 20M, 48M sampling rate, 2 channels,
alternating support X-T and XY alternating pattern of two-channel virtual
oscilloscope, spectrum analyzer, data recorder.
205C and 205X support logic analyzer. Logic analyzer support our Logic
software and Saleae Logic 2 kinds of software, Saleae Logic supports SPI, IIC, UART,
etc. 17 kinds protocol analysis.
205B and 205X support DDS function. DDS support 5 kinds of waveform output,

Oscilloscope Spectrum Analyzer Data Recorder Logic Analyzer DDS


ISDS205A √ √ √
ISDS205B √ √ √ √
ISDS205C √ √ √ √
ISDS205X √ √ √ √ √
Sine wave can output up to 20M.

2.Feature Description
Digital Oscilloscope
Channels 2
Impedance 1MΩ 25pF
Coupling AC/DC
Vertical Resolution 8Bit
-6V ~ 6V(probe X1)
Gain Range
-60V ~ 60V(probe X10)
Vertical Accuracy ±3%
Time Base Range 10ns/div-100ms/div
Input Protection Diode,50Vpk
Auto Set Yes(10Hz to 20MHz)
Trigger Mode Auto、Normal and Signal
Trigger Type No、Rising edge、Falling edge、
Rising edge or Falling edge
Trigger Level Yes
Trigger Source CH1, CH2
Buffer Size 1MB/CH
Bandwidth 20MHz
Max Sample 48MS/s

Electronics Katrangi Trading

www.ekt2.com
Vertical Mode CH1, CH2, ADD, SUB, MUL
Display Mode X、Y-T 、 X-Y
Measurements Yes
Wave Save Osc(Private)、Excel and Bmp

Spectrum Analyzers
Channels 2
Bandwidth 20MHz
Algorithm FFT(18 windows)、correlation
FFT Points 8-1048576/CHN
FFT Measure Harmonic(1-7)、SNR、SINAD、ENOB、THD、SFDR
FIR filter supports arbitrary range of frequency
sampling method , and Rectangle, bartlett, triangular,
cosine, hanning, bartlett_hanning, hamming, blackman,
blackman_Harris, tukey, Nuttall, FlatTop, Bohman,
Filter Process
Parzen, Lanczos, kaiser, gaussand dolph_chebyshev,
window method design.
IIR filter support "Butterworth", "Chebyshev I",
"Chebyshev II", "Elliptic" type of filter design
Note: The oscilloscope factory calibration, if you are not satisfied with the
measurements, can manual calibration, the specific reference oscilloscope
instructions.

Data Recorder
Channel 2
Impedance 1MΩ 25pF
Coupling AC/DC
Vertical Resolution 8Bit
-6V ~ 6V(probe X1)
Gain Range
-60V ~ 60V(probe X10)
1 channel : 1K~24M Hz
Sample
2 channel : 1K~16M Hz
The maximum 4G, recording time associated with the
Save File
sampling rate
Note: The specific speed recorder with computer processing speed, and if use
high sampling rate, the situation may break.

Made in China

Electronics Katrangi Trading

www.ekt2.com