Professional Documents
Culture Documents
B Vane Pumps
B Vane Pumps
B
Output Flow at 1200 r/min at No-Load Maximum
U.S.GPM
Operating
Graphic .3 .5 1 2 5 10 20 50 100 200
Pump Type Pressure Page
Symbols
MPa
1 2 5 10 20 50 100 200 500 800
(PSI)
L/min
"PV2R" Series 21 163
Single Pumps PV2R1 PV2R2 PV2R3 PV2R4 (3050)
"PV2R4A" Series 17.2
PV2R4A 177
Fixed Displacedment
159
Hydraulic Fluids
1. Type of hydraulic fluids
Any type of hydraulic fluids listed in the Table 1 below can be used. However, the specifications of the pumps such
as maximum pressure and maximum pump speed may be changed according to the type of hydraulic fluids to be used.
For details, please refer to the specifications of the pump concerned.
Hydraulic fluids (Table 1)
Petroleum Base Oils Use anti-wear type oils or R & O (Rust and Oxidation inhibitor) type oils (equivalent to ISO VG32 or 46).
3. Control of contamination
Contamination of hydraulic fluids results in pump failures and reduced pump lives. Carry out sufficient contamination
control for hydraulic fluids and keep contamination level within NAS class 12.
Also, use a 100 µm (150-mesh) tank filter on the suction side, more than 50 mm (2 in.) away from the tank bottom.
Instructions
1. Alignment of shaft
Employ a flexible coupling whenever possible, and avoid any stress from bending or thrust. B
Maximum permissible misalignment is less than 0.1 mm (.004 inches) TIR and maximum permissible misangular is
less than 0.2°.
2. Suction pressures
Set the suction pressure at pump inlet port at the value given in the table below. Furthermore, use the pipes in the
suction side having the diameter as indicated on the installation drawings. In case where the pump is installed on the
Suction Pressure
Minimum
Pump Type
Phosphate ester type fluid Maximum
Petroleum base oil
Water containing fluid
PV2R1 -20 kPa
PV2R2 (5.9 in. Hg Vacuum)
"PV2R" Series
Single Pumps PV2R3
-20 kPa
PV2R4
(5.9 in. Hg Vacuum)
PV2R4A
-20 kPa
PV2R12
(5.9 in. Hg Vacuum)
-16 kPa +30 kPa
PV2R13 (4.7 in. Hg Vacuum) (+4.3 PSIG)
PV2R23
"PV2R" Series PV2R33
Double Pumps PV2R14 -20 kPa
PV2R24 (5.9 in. Hg Vacuum)
PV2R34
PV2R24A
PV2R34A
In relation to the rotating speed of the pump, the minimum suction pressure may be restricted for a certain nominal
displacement. For details, please refer to the specifications of the pump concerned.
3. Precautions at starting
At an initial operation or at an operation after a long rest, the pump may have difficulty in sucking up fluid. In such cases,
an air bleed valve should be installed beforehand on the discharge side (model No. ST1004-*-10*, see page 820), or
discharge air by slightly slackening the connection on the discharge side. At starting, operate the pump intermittently as
far as possible with no load.
For fluid viscosity at starting, see the item of "Hydraulic Fluids".
4. Other precautions
If a pump is used at speed below 1200 r/min, install the pump with the suction port upside so that the pump can suck up
fluid easily at starting.
''PV2R1'' Series
Single Pumps PV2R1-*-*-RAA-40* PV2R1-*-*-RAA-42* Yes Lower noise level
41*
''PV2R2'' Series
PV2R2-*-*-RAA-40* PV2R2-*-*-RAA-41* Yes Lower noise level
Single Pumps
''PV2R3'' Series
PV2R3-*-*-RAA-30* PV2R3-*-*-RAA-31* Yes Lower noise level
Single Pumps
''PV2R12'' Series
Double Pumps PV2R12-*-*-*-REAA-40* PV2R12-*-*-*-REAA-42* Yes Lower noise level
41*
''PV2R13'' Series
Double Pumps PV2R13-*-*-*-RAAA-40* PV2R13-*-*-*-RAAA-42* Yes Lower noise level
41*
''PV2R14'' Series
Double Pumps PV2R14-*-*-*-RAAA-30* PV2R14-*-*-*-RAAA-32* Yes Lower noise level
31*
''PV2R23'' Series
PV2R23-*-*-*-REAA-40* PV2R23-*-*-*-REAA-41* Yes
Double Pumps
''PV2R33'' Series
Double Pumps PV2R33-*-*-*-RAAA-30* PV2R33-*-*-*-RAAA-31* Yes
''PV2R34'' Series
Double Pumps PV2R34-*-*-*-REAA-30* PV2R34-*-*-*-REAA-31* Yes
"PV2R" Series
Model Number Designation
F- PV2R1 -6 -L -R A A -42 -*
Nominal Discharge Suction
Series Type of Shaft Design Design
Special Seals Displacement Port Port
Number cm3/rev Mounting Rotation Position Position Number Standards
6, 8, 10, 12
14, 17, 19 (Viewed from Shaft End)
PV2R1 L: 42
F: 23, 25, 31
Foot
For phosphate 41, 47, 53
ester type PV2R2 Mounting R: A: A: 41
59, 65 Refer to 2
fluids (Omit F: Clockwise 1 Upwards Upwards
if not PV2R3 76, 94, 116 Flange 31
required) (Normal) (Normal) (Normal)
136, 153, 184 Mounting
PV2R4 200, 237 30
1. Available to supply pump with anti-clockwise rotation. 2.Design Standards:None.....Japanese Standard "JIS"
Consult Yuken for details. 80 . .. ...... European Design Standard
90 . .. ...... N. American Design Standard
1. In case of using socket welding flanges, there is a case where the operating pressure should be set lower than the normal because of strength of the
flanges. Therefore, please pay cautious attention to the operating pressure when the socket welding flanges are used.
2. As dimensions of the pipe flange mounting surface are conformed to SAE 4 Bolt Split Flange (Standard Pressure Series), pipe flanges conforming to
the SAE Standards can be used.
Notes: Special seals (Viton seals) are required when phosphate ester type fluids are used. (Prefix "F-" to the pipe flange kit number when ordering.)
Details of the pipe flange kits are shown on page 824.
Mass
Approx. Mass kg (lbs.)
Model Numbers
Flange Mtg. Foot Mtg.
PVR2R1 9.0 ( 19.8) 11.2 ( 24.7)
PVR2R2 15.5 ( 34.2) 19.8 ( 43.7)
PVR2R3 30.9 ( 68.1) 40.9 ( 90.2)
PVR2R4 68.5 (151) 93.5 (206)
Key Width
Suction Port 13 7
28(1.10) Dia. (.51) (.276)
R9.5(R.37) R8(R.31)
(.1886)
(.1874)
40(1.57)
4.79
4.76
(2.063)
52.4
"C" Thd.
17(.67) Deep 26.2 17.5 "D" Thd. "E" Deep
4 Places (1.031) (.689) 4 Places
178.5
(7.03) Port Position
56 69.5 A
(2.20) (2.74)
19.05(.7500) Dia.
44.5 130
(1.75) (5.12)
19.02(.7488)
21.24(.836)
21.08(.830)
36 106
(1.42) 11(.433) Dia. Through (4.173)
25 2 Places
(.98)
(2.28)
R12
82.55 Dia.
58
(R.47)
97(3.82) Sq.
(4.19)
106.5
(3.250)
(3.248)
82.50
(.71)
18
95(3.74)
DIMENSIONS IN
MILLIMETRES (INCHES)
Foot Mtg.: PV2R1-*-L-RAA-42/4290
80
14
(.12)
3
50 56.5 95
(1.969) (2.22) (3.74)
95 27.5 72.5 72.5
(3.74) (1.08) (2.854) (2.854)
180
(7.09)
KeyWidth
Suction Port
34(1.34) Dia. (.63) (.354)
R11(R.43) R9(R.35)
(.2512)
(.2500)
49(1.93)
6.38
6.35
(2.311)
58.7
(1.874)
47.6
65(2.56)
"C" Thd.
"E" Deep "D" Thd. 17(.67) Deep
30.2 22.2
4 Places (1.189) (.874) 4 Places
59 174
(2.32) (6.85)
25.35( .9980)
25.40( 1.0000)
28.18(1.109)
28.00(1.102)
47 146
(1.85) (5.748)
32
(1.26) R14
(2.76)
(R.55)
70
101.60 Dia.
125(4.92) Sq.
(5.22)
132.5
(4.000)
(3.998)
101.55
(.98)
25
DIMENSIONS IN
MILLIMETRES (INCHES)
Foot Mtg.: PV2R2-*-L-RAA-41/4190
60 73 120
(2.362) (2.87) (4.72)
95 95
115 38
(3.740) (3.740)
(4.53) (1.50)
230
(9.06)
Key Width
Suction Port 21 9
(.83) (.354)
51(2.01) Dia.
R13(R.51) R11(R.43)
(.3138)
(.3126)
65(2.56)
7.97
7.94
(3.063)
77.8
75 213
(8.39)
31.75(1.2500)
31.70(1.2480)
(2.95)
35.32(1.391)
35.14(1.383)
63 181
(2.48) (7.126)
40
(1.57) R16
(R.63)
(3.54)
166(6.54) Sq.
90
127.00 Dia.
(6.81)
173
(5.000)
(4.998)
126.95
(1.22)
31
Dimensions
Model Numbers "C" Thd. "D" Thd. mm (Inches)
E F
PV2R3-*-F-RAA-31 M12 M10 19 (.75) 19 (.75)
PV2R3-*-F-RAA-3190 1/2-13 UNC 7/16-14 UNC 21 (.83) 20 (.79)
DIMENSIONS IN
MILLIMETRES (INCHES)
Foot Mtg.: PV2R3-*-L-RAA-31/3190
76.2 88 145
(3.000) (3.46) (5.71)
131 50 117.5 117.5
(5.16) (1.97) (4.626) (4.626)
274
(10.79)
Key Width
Suction Port 25 13
76(2.99) Dia. 61.9 (.98) (.512)
(2.437)
"C" Thd. "E" Deep
4 Places
(.3764)
(.3752)
9.56
9.53
(4.189)
106.4
(2.752)
69.9
118(4.65)
R15(R.59)
R37(R1.46) 35.7 "D" Thd. "F" Deep
(1.406) 4 Places
R13(R.51)
354
(13.94)
110 135 Port Position
(4.33) (5.31)
Dia.
24 92 A
(.94) (3.62)
38.10(1.5000)
38.05(1.4980)
273(10.75) Sq.
42.36(1.668)
42.18(1.661)
76
(2.99) 228.6(9.000)
56
(2.20)
(5.51)
(4.53)
140
115
152.40 Dia.
228.6(9.000)
(8.54)
217
(6.000)
(5.998)
152.35
Dimensions
Model Numbers "C" Thd. "D" Thd. mm (Inches)
E F
PV2R4-*-F-RAA-30 M16 M12 19 (.75) 19 (.75)
PV2R4-*-F-RAA-3090 5/8-11 UNC 1/2-13 UNC 21 (.83) 21 (.83)
DIMENSIONS IN
MILLIMETRES (INCHES)
Foot Mtg.: PV2R4-*-L-RAA-30/3090
22(.866) Dia. Through
354 43(1.69) Dia. Spotface
(13.94) 4 Places
110 135 A
(4.33) (5.31)
327.3(12.89)
(7.37)
187.3
(1.18)
(1.14)
30
29
(.12)
3
280
114.3 99 (11.02)
(4.500) (3.90)
187.3 187.3
185 60 (7.374) (7.374)
(7.28) (2.36) 438
(17.24)
Noise Level
Measuring conditions
Fluid viscosity : 20 mm2/s (100 SSU)
Measurement point : One metre (3.3 ft.) horizontally away from pump head cover
B
Back ground noise : 40 dB (A)
PV2R1-6 PV2R1-31
dB(A) dB(A)
60 60
"PV2R" Series
Noise Level
Noise Level
1000 r/min
50 50
1200 r/min
1000 r/min
45 45
40 40
0 3.5 7 10.5 14 17.5 21 MPa 0 3.5 7 10.5 14 17.5 21 MPa
(1000) (2000) (3000) (PSI) (1000) (2000) (3000) (PSI)
Pressure Pressure
PV2R2-41 PV2R2-65
dB(A) dB(A)
65 65
60 60
1200 r/min
Noise Level
Noise Level
1200 r/min
55 55
1000 r/min
1000 r/min
50 50
45 45
0 3.5 7 10.5 14 17.5 21 MPa 0 3.5 7 10.5 14 17.5 21 MPa
(1000) (2000) (3000) (PSI) (1000) (2000) (3000) (PSI)
Pressure Pressure
dB(A)
PV2R3-76 dB(A)
PV2R3-116
65 65
1200 r/min
1200 r/min
60 60
Noise Level
Noise Level
1000 r/min
1000 r/min
55 55
50 50
0 3.5 7 10.5 14 17.5 21 MPa 0 3.5 7 10.5 14 17.5 21 MPa
(1000) (2000) (3000) (PSI) (1000) (2000) (3000) (PSI)
Pressure Pressure
PV2R4-136 PV2R4-184
dB(A) dB(A)
70 70
Noise Level
55 55
0 3.5 7 10.5 14 17.5 21 MPa 0 3.5 7 10.5 14 17.5 21 MPa
(1000) (2000) (3000) (PSI) (1000) (2000) (3000) (PSI)
Pressure Pressure
PV2R1-6 PV2R1-8
L/min
U.S.GPM L/min U.S.GPM
15
11
2.8 3.8 1800 r/min
10 1800 r/min 14
2.4 9 3.4 13
Output Flow
Output Flow
7 11
1200 r/min 2.6 10
1.6 6 1200 r/min
5 9 kW HP
1.2 2.2 10
8 7
4
1000 r/min kW HP 1000 r/min
.8 3 6 8 1.8 7 6 8
Input Power
5 6 5
6 1.4 6
Input Power
4 5 4
3 4 3 4
2 2
2 2
1 1
0 0 0
0
0 3.5 7 10.5 14 17.5 21 MPa 0 3.5 7 10.5 14 17.5 21 MPa
(1000) (2000) (3000) (PSI) (1000) (2000) (3000) (PSI)
16 16
Pressure (2320) Pressure (2320)
PV2R1-10 PV2R1-12
U.S.GPM
L/min L/min
5.8
U.S.GPM 18 22 1800 r/min
4.4 17 1800 r/min 5.4 21
16 20
4.0 15 5.0
19 kW HP
1500 r/min 14
3.6 14 1500 r/min 4.6 18 10
Output Flow
13 kW HP 17 9 12
Output Flow
3.2 11 4.2
12 8 16 8
1200 r/min 10 10
11 7 3.8 15 1200 r/min 7
Input Power
2.8
10 6 8 14 6 8
3.4
Input Power
Pressure Pressure
Typical Pump Characteristics at Viscosity 20 mm2/s (100 SSU) [ISO VG32 Oils, 50°C (122°F)]
B
PV2R1-14 PV2R1-17
L/min L/min
U.S.GPM 28 U.S.GPM 32
7 26 8 30
1800 r/min 1800 r/min
24 28
"PV2R" Series
20 24
Output Flow
Output Flow
5 6
18 22
16 1200 r/min 20 kW HP
4 5 1200 r/min 20
14 1000 r/min kW HP 18 14
12 12 16 16 1000 r/min 12 16
3 4
10 10 14 10
12 12
Input Power
Input Power
2 8 3 12 8
6 8 6 8
4 4
4 4
2 2
0 0 0 0
0 3.5 7 10.5 14 17.5 21 MPa 0 3.5 7 10.5 14 17.5 21 MPa
(1000) (2000) (3000) (PSI) (1000) (2000) (3000) (PSI)
Pressure Pressure
PV2R1-19 PV2R1-23
L/min L/min
U.S.GPM 40 U.S.GPM 45
10
11 1800 r/min
35 40
9 1800 r/min 10
8 30 35
9 1500 r/min
Output Flow
1500 r/min
Output Flow
kW
7
25 8 30 20 HP
1200 r/min 1200 r/min 24
6 kW HP
7
20 15 20 25 15 20
5 1000 r/min 1000 r/min
6
Input Power
16 16
Input Power
4 15 10 20 10 12
12 5
3 8 8
10 5 4 15 5
4 4
0 0
0 0
0 3.5 7 10.5 14 17.5 21 MPa 0 3.5 7 10.5 14 17.5 21 MPa
(1000) (2000) (3000) (PSI) (1000) (2000) (3000) (PSI)
Pressure Pressure
PV2R1-25 PV2R1-31
L/min U.S.GPM
U.S.GPM L/min
50 16 60
13
12 1800 r/min 1800 r/min
14
40 50
10 1500 r/min
1500 r/min
Output Flow
Output Flow
12
8 30 1200 r/min 40
10 1200 r/min
1000 r/min
6
20 8 1000 r/min
30
4 HP HP
kW 30 6 kW 30
20 Input Power
20 20
Input Power
20 20
10 10
10 10
0 0 0
0
0 3.5 7 10.5 14 17.5 21 MPa 0 3.5 7 10.5 14 17.5 21 MPa
(1000) (2000) (3000) (PSI) (1000) (2000) (3000) (PSI)
Pressure 16
Pressure (2320)
PV2R2-41 U.S.GPM
PV2R2-47
U.S.GPM L/min L/min
20 75 23
22 85
1800 r/min 1800 r/min
70 80
18
20
16 60 1500 r/min 70
18 1500 r/min
Output Flow
Output Flow
14
50 16 60
12 1200 r/min
14 1200 r/min kW
40 1000 r/min 50 40 HP
10 50
12 1000 r/min
kW HP
8 30 30 40 40 30 40
10
30 30
Input Power
Input Power
20 30 20
20 20
10 10
10 10
0 0
0
0 0
0 3.5 7 10.5 14 17.5 21 MPa 3.5 7 10.5 14 17.5 21 MPa
(1000) (2000) (3000) (PSI) (1000) (2000) (3000) (PSI)
Pressure Pressure
Typical Pump Characteristics at Viscosity 20 mm2/s (100 SSU) [ISO VG32 Oils, 50°C (122°F)]
B
PV2R2-53 PV2R2-59
U.S.GPM U.S.GPM
30 L/min L/min
30 110
110
1800 r/min
26 100 26 100
1800 r/min
Output Flow
90 90
Output Flow
"PV2R" Series
18 70 18 70 1200 r/min
60 1200 r/min 60
14 1000 r/min
50 1000 r/min 14 50
kW
10 40 40 50
10 HP
kW 60
40 HP 40
50 50
30 40 30 40
Input Power
Input Power
30 30
20 20
20 20
10 10
10 10
0 0 0 0
0 3.5 7 10.5 14 17.5 21 MPa 0 3.5 7 10.5 14 17.5 21 MPa
(1000) (2000) (3000) (PSI) (1000) (2000) (3000) (PSI)
Pressure Pressure
PV2R2-65
L/min
140
U.S.GPM
34 130
120
30 1800 r/min
110
Output Flow
26 100
1500 r/min
90
22
80
1200 r/min kW
18 70 50
1000 r/min HP
60 60
14
50 40
50
30 40
Input Power
30
20
20
10
10
0 0
0 3.5 7 10.5 14 17.5 21 MPa
(1000) (2000) (3000) (PSI)
Pressure
PV2R3-76 PV2R3-94
U.S.GPM
L/min L/min
38 U.S.GPM
140 170
1800 r/min 44 1800 r/min
34 130 42 160
120 150
30 38
110 1500 r/min
Output Flow
140
1500 r/min
Output Flow
26 100 kW 34 130
HP
90 1200 r/min 60 80 120
22 30
80 110 1200 r/min
1000 r/min 70
18 70 50 26 100
60 60 90 1000 r/min
14 22
50 40 80 HP
50 kW 100
18 70 70
30 40 60 80
Input Power
50
Input Power
30 60
20 40
20 30 40
10 20
10 20
10
0 0
0 0
0 3.5 7 10.5 14 17.5 21 MPa 0 3.5 7 10.5 14 17.5 21 MPa
(1000) (2000) (3000) (PSI) (1000) (2000) (3000) (PSI)
Pressure Pressure
PV2R3-116 PV2R4-136
U.S.GPM L/min L/min
56 210 U.S.GPM 280
1800 r/min 70 260
200
52 1800 r/min
190 240
48 60 220
180
Output Flow
1500 r/min
170 1500 r/min 200
44 50
Output Flow
160 180
1200 r/min
40 150 160
40
140 140 1000 r/min HP
36 1200 r/min
130 120 120
30 kW
32 120 100 80
1000 r/min 100
110 kW 70
28 HP
100 60 80 60 80
Input Power
24 90 50 50
60 60
Input Power
40 40
30 40 30 40
20 20
20 20
10 10
0 0 0
0
0 3.5 7 10.5 14 17.5 21 MPa 0 3.5 7 10.5 14 17.5 MPa
(1000) (2000) (3000) (PSI) (500) (1000) (1500) (2000) (2500) (PSI)
Pressure 16 Pressure
(2320)
Typical Pump Characteristics at Viscosity 20 mm2/s (100 SSU) [ISO VG32 Oils, 50°C (122°F)]
B
PV2R4-153 PV2R4-184
U.S.GPM L/min
U.S.GPM L/min
80 300 90 340
1800 r/min
280 1800 r/min 320
70 260 80
280
"PV2R" Series
1500 r/min 1500 r/min
Output Flow
60 220 70 260
HP
200 240 160
50 1200 r/min kW
180 60 1200 r/min
220 110
140
160 1000 r/min HP 200 100
40 kW 50
140 90 1000 r/min
120 180 90 120
30 120 80 160 80
100 40 100
Input Power
70 70
60 80 60 80
Input Power
50 50
60 60
40 40
30 40 30 40
20 20
20 20
10 10
0 0
0 0
0 3.5 7 10.5 14 17.5 MPa 0 3.5 7 10.5 14 17.5 MPa
(500) (1000) (1500) (2000) (2500) (PSI) (500) (1000) (1500) (2000) (2500) (PSI)
Pressure Pressure
PV2R4-200 PV2R4-237
U.S.GPM L/min L/min
U.S.GPM
100 380 115 440
1800 r/min 1800 r/min
360 110 420
90 340 400 kW
320 380 140 HP
100
1500 r/min 180
80 300 360 1500 r/min 130
Output Flow
kW HP
280 120 160 90 340 120 160
Output Flow
200 80 260 80
50 100 100
Input Power
PV2R1-*-*-RAA-42/4290
PV2R2-*-*-RAA-41/4190
PV2R3-*-*-RAA-31/3190
PV2R4-*-*-RAA-30/3090
21 2 4 10 15 13 14 16 1 19 17 9 3 18
8 7 12 6 5
11
Y
22
23
24
29
Y 20
Section Y-Y
26
Section X-X
25
X
27
28
Cartridge Kits
Model Numbers 4 Cartridge Kit Numbers Model Numbers 4 Cartridge Kit Numbers
PV2R1-6-*-RAA-42* CPV2R1-6-R-42 PV2R2-41-*-RAA-41* CPV2R2-41-R-41
PV2R1-8-*-RAA-42* CPV2R1-8-R-42 PV2R2-47-*-RAA-41* CPV2R2-47-R-41
PV2R1-10-*-RAA-42* CPV2R1-10-R-42 PV2R2-53-*-RAA-41* CPV2R2-53-R-41
PV2R1-12-*-RAA-42* CPV2R1-12-R-42 PV2R2-59-*-RAA-41* CPV2R2-59-R-41
PV2R1-14-*-RAA-42* CPV2R1-14-R-42 PV2R2-65-*-RAA-41* CPV2R2-65-R-41
PV2R1-17-*-RAA-42* CPV2R1-17-R-42 PV2R3-76-*-RAA-31* CPV2R3-76-R-31
PV2R1-19-*-RAA-42* CPV2R1-19-R-42 PV2R3-94-*-RAA-31* CPV2R3-94-R-31
PV2R1-23-*-RAA-42* CPV2R1-23-R-42 PV2R3-116-*-RAA-31* CPV2R3-116-R-31
PV2R1-25-*-RAA-42* CPV2R1-25-R-42 PV2R4-136-*-RAA-30* CPV2R4-136-R-30
PV2R1-31-*-RAA-42* CPV2R1-31-R-42 PV2R4-153-*-RAA-30* CPV2R4-153-R-30
PV2R4-184-*-RAA-30* CPV2R4-184-R-30
PV2R4-200-*-RAA-30* CPV2R4-200-R-30
PV2R4-237-*-RAA-30* CPV2R4-237-R-30
1. For the brands of anti-wear type water-glycols , see the item of "Hydraulic Fluids" on page 160.
2. If PV2R4A-193 is used at speed above 1700 r/min, the suction pressure is limited to 0 kPa (0 in. Hg.).
3. If phosphate ester or water containing fluids are used, the maximum speed is limited to 1200 r/min.
F: L:
(Viewed from Shaft End)
For phosphate Foot
ester type Mounting R: A: A:
PV2R4A 138, 162, 193 1 10 Refer to 2
fluids (Omit F: Clockwise Upwards Upwards
if not Flange (Normal) (Normal) (Normal)
required) Mounting
1. Available to supply pump with anti-clockwise rotation. 2.Design Standards:None.....Japanese Standard "JIS"
Consult Yuken for details. 80 . .. ...... European Design Standard
90 . .. ...... N. American Design Standard
1. In case of using socket welding flanges, there is a case where the operating pressure should be set lower than the normal because of strength of the
flanges. Therefore, please pay cautious attention to the operating pressure when the socket welding flanges are used.
2. As dimensions of the pipe flange mounting surface are conformed to SAE 4 Bolt Split Flange (Standard Pressure Series), pipe flanges conforming to
the SAE Standards can be used.
Notes: Special seals (Viton seals) are required when phosphate ester type fluids are used. (Prefix "F-" to the pipe flange kit number when ordering.)
Details of the pipe flange kits are shown on page 824.
Discharge Port
7.94(.3126)
R15(R.59)
(2.752)
69.9
166(6.54)
(4.189)
106.4
118
(4.65)
76(2.99)
"D" Thd. "F" Deep
61.9 35.7 4 Places
(2.437) (1.406)
"C" Thd. "E" Deep
4 Places
Port Position
318.5 (12.54) A
31.75(1.250) Dia.
79 (3.11) 181(7.126)
66.5
136.3(5.37)
(2.62)
110 (4.33)
236.3 (9.30)
50
126.95 Dia.
(1.97)
(1.22)
(5.000)
(4.998)
31
127.00
Dimensions
Model Numbers "C" Thd. "D" Thd. mm (Inches)
E F
PV2R4A-*-F-RAA-10 M16 M12 29 (1.14) 22 (.87)
PV2R4A-*-F-RAA-1090 5/8-11 UNC 1/2-13 UNC 21 (.83) 21 (.83)
DIMENSIONS IN
MILLIMETRES (INCHES)
Foot Mtg.: PV2R4A-*-L-RAA-10/1090
(.08)
2
76.2 92 145
(3.000) (3.62) (5.71)
131 54 117.5 117.5
(5.16) (2.13) (4.626) (4.626)
274
(10.79)
Noise Level
Measuring conditions
Fluid viscosity : 20 mm2/s (100 SSU)
Measurement point : One metre (3.3 ft.) horizontally away from pump head cover
B
Back ground noise : 40 dB (A)
PV2R4A-138 PV2R4A-193
75 75
1000 r/min
Noise Level
Noise Level
65 65
60 60
55 55
0 3.5 7.0 10.5 14.0 17.5 MPa 0 3.5 7.0 10.5 14.0 17.5 MPa
(1000) (2000) (2500) (PSI) (1000) (2000) (2500) (PSI)
Pressure Pressure
Typical Pump Characteristics at Viscosity 20 mm2/s (100 SSU) [ISO VG32 Oils, 50°C (122°F)]
PV2R4A-138 PV2R4A-162
L / min U.S.GPM L / min
U.S.GPM 280 80 300
70 1800 r/
260 280 min
1800 r/m 70
240 in 260
60 1500 r/
220 240 min
Output Flow
Output Flow
1500 r/ 60
200 min 220
50
180 200
50 1200 r/m
1200 r/m in kW HP
160 in 180
40
140 1000 r/m 160 1000 r/m 100
in 40 in 130
kW HP
120 140 90 120
30
100 80 110 80
100 30 100
70 70
60 80 60 80
Input Power
Input Power
50 50
60 60
40 40
30 40 30 40
20 20
20 20
10 10
0 0
0 0
0 3.5 7.0 10.5 14.0 17.5 MPa 0 3.5 7.0 10.5 14.0 17.5 MPa
(1000) (2000) (2500) (PSI) (1000) (2000) (2500) (PSI)
Pressure Pressure
PV2R4A-193
U.S.GPM L / min
95 360
90 340 1800 r/
min
320
80 300
1500 r/
280 min
70 260
Output Flow
240
60 1200 r/m
220 in
200
50 1000 r/m
180 in
160 kW HP
40
120 160
100
120
Input Power
80
60 80
40
40
20
0
0
0 3.5 7.0 10.5 14.0 17.5 MPa
(1000) (2000) (2500) (PSI)
Pressure
PV2R4A-*-*-RAA-10/1090
2 4 9 10 11 1 13 15 5 8 3 6
12
16
X Section X-X
Graphic Symbol
6, 8
10, 12 A:
76, 94 L:
PV2R13 14, 17 Upwards 42
116 Foot Mtg.
(Normal)
19, 23
25, 31
F: E:
Special 41, 47 52, 60 R: 1 A: A:
Clockwise Left 45°
seals for PV2R23 53, 59 66, 76 Upwards Upwards 41
(Normal) Upwards
phosphate 65 94, 116 (Normal) (Normal)
(Normal) Refer to 2
ester type
fluids F: A:
76, 94 76, 94
(Omit if not PV2R33 Flange Upwards 31
116 116 Mtg. (Normal)
required)
6, 8
10, 12
PV2R14 32
14, 17 A:
19, 23 Upwards
(Normal)
136, 153
26, 33 184, 200
PV2R24 31
41, 47 237
E:
52, 60
Left 45°
PV2R34 66, 76 31
Upwards
94, 116 (Normal)
12 100
PV2R14
14 Allowable
PV2R12 PV2R13
17 80 60 Range PV2R12
19
23 60
40
25 Allowable
Nominal 31 40 Range
Displace- 26 20
ment, 20
33
Small PV2R24 0
Volume 41 0
Pump 47 600 1000 1200 1500 1800
53 PV2R23 Shaft Speed r/min
59
65 1. For the brands of anti-wear type water-glycols, see the item of "Hydraulic
52
Fluids" on page 160.
60
66 2. For pressures above 16 MPa (2320 PSI), raise the speed over 1450 r/min.
PV2R34 3. If nominal displacement "23", of the PV2R14 series is selected, the
76
94 PV2R33 maximum operating pressure is limited to 16 MPa (2320 PSI).
116
"PV2R" Series
PV2R24 2 3 1200 600 3
1800 600
PV2R34 2 1200 600
1800 600 Same as single pump Same as single pump
1. For PV2R33-116-116, the maximum speed is limited to 1500 r/min. PV2R13 "PV2R1", refer to pages "PV2R3", refer to page
170 - 172. 174.
2. As for the models (nominal displacements) listed below, the mini-
mum suction pressure are limited in relation to the shaft speed.
Same as single pump
[For other models, the minimum suction pressure is -20 kPa (5.9 in. "PV2R3", refer to page
Hg vacuum) irrespective of speed. Same as single pump 174.
PV2R23 "PV2R2", refer to pages However, as for
Min. Suction Pres. kPa (in. Hg Vacuum) 172 & 173. displacement of "52",
Model Numbers "60" and "66", refer to
Less than 1700 r/min 1700 - 1800 r/min pages 192 & 193.
Mass
Model Approx. Mass kg (lbs.)
Numbers
Mounting PV2R12 PV2R13 PV2R23 PV2R33 PV2R14 PV2R24 PV2R34
Flange Mtg. 25 (55.1) 45.6 (101) 51 (112) 84 (185) 75 (165) 78 (172) 98 (216)
Foot Mtg. 29.3 (64.6) 55.6 (123) 61 (135) 94 (207) 100 (221) 103 (227) 123 (271)
1. In case of using socket welding flanges, there is a case where the operating pressure should be set lower than the normal because of strength of the
flanges. Therefore, please pay cautious attention to the operating pressure when the socket welding flanges are used.
2. As dimensions of the pipe flange mounting surface are conformed to SAE 4 Bolt Split Flange (Standard Pressure Series), pipe flanges conforming to
the SAE Standards can be used.
Notes: Special seals (Viton seals) are required when phosphate ester type fluids are used. (Prefix "F-" to the pipe flange kit number when ordering.)
Details of the pipe flange kits are shown on page 824.
89 5
B
38 .500
(.6 17.
)
(1
.1 )
Large Volume Pump
Discharge Port
Key Width
21(.83) Dia. "E" Thd. "K" Deep R8(R.31)
16 9
(.63) (.354) 4 Places 40(1.57)
Suction Port R10
53.5(2.11) Dia. (R.39)
.
.8 Sq
R9(R.35) E
(3 97
(.2512)
(.2500)
2)
49(1.93)
6.38
6.35
Small
Volume Pump
(3.063)
Discharge Port
77.8
"PV2R" Series
(1.874)
47.6
Small Volume Pump 58 8)
.2
Discharge Port (2
15(.59) Dia. 42.9
(1.689) "D" Thd. 17(.67) Deep View Arrow X
"C" Thd. "J" Deep 22.2
4 Places
4 Places (.874)
326
(12.83) Suction Port and
129 80 95 Large Volume Pump
(5.08) (3.15) (3.74) Discharge Port
Dia.
67 Position A
(2.64)
25.35( .9980)
25.40( 1.0000)
174
28.18(1.109)
28.00(1.102)
55 (6.85)
(2.17)
146
40 (5.748)
(1.57)
R14
(2.95)
(2.76)
(R.55)
125(4.92) Sq.
101.60 Dia.
75
70
X
(5.63)
143
(4.000)
(3.998)
101.55
(.98)
25
Dimensions mm (Inches)
Model Numbers "C" Thd. "D" Thd. "E" Thd.
J K
PV2R12-*-*-F-REAA-42 M12 M10 M8 19 (.75) 14 (.55)
PV2R12-*-*-F-REAA-4290 1/2-13 UNC 3/8-16 UNC 5/16-18 UNC 21 (.83) 16 (.63)
DIMENSIONS IN
MILLIMETRES (INCHES)
Foot Mtg.: PV2R12-*-*-L-REAA-42/4290
(.59)
102
14
15
(.12)
3
60 82 120
(2.362) (3.23) (4.72)
115 47 95 95
(4.35) (1.85) (3.740) (3.740)
230
(9.06)
Key Width
21 9
Discharge Port (.83) (.354)
15(.59) Dia. R15 R11(R.43)
(R.59)
R8(R.31)
(.3138)
(.3126)
65(2.56)
7.97
7.94
(3.82) Sq.
(1.500)
38.1
118 )
5
97
(4.6
(2.311)
58.7
40(1.57)
(4.189)
106.4
61.9
"E" Thd. "J " Deep 17.5 (2.437) "D" Thd. "H" Deep
4 Places (.689) 30.2 4 Places
(1.189)
"C" Thd. "F" Deep
4 Places
370
(14.57)
120.5 115.5 112 Port Position
(4.74) (4.55) (4.41)
Dia.
75 A
(2.95)
31.75(1.2500)
31.70(1.2480)
35.32(1.391)
35.14(1.383)
63 213
(2.48) (8.39)
40 181
(1.57) (7.126)
R16
(3.74)
(3.54)
95
166(6.54) Sq.
(R.63)
(2.28)
127.00 Dia.
90
58
(7.20)
183
(5.000)
(4.998)
126.95
(1.22)
31
Dimensions mm (Inches)
Model Numbers "C" Thd. "D" Thd. "E" Thd.
F H J
PV2R13-*-*-F-RAAA-42 M16 M10 M8 19 (.75) 19 (.75) 14 (.55)
PV2R13-*-*-F-RAAA-4290 5/8-11 UNC 7/16-14 UNC 5/16-18 UNC 21 (.83) 20 (.79) 16 (.63)
DIMENSIONS IN
MILLIMETRES (INCHES)
Foot Mtg.: PV2R13-*-*-L-RAAA-42/4290
(4.31)
109.5
23
22
(.08)
2
76.2 88 145
(3.000) (3.46) (5.71)
131 50 117.5 117.5
(5.16) (1.97) (4.626) (4.626)
274
(10.79)
Key Width
21 9
Suction Port R15 (.83) (.354)
"J" Thd. 17(.67) Deep
78.5(3.09) Dia. (R.59) R11
(R.43) 4 Places
Small Volume Pump
(.3138)
(.3126)
65
7.97
7.94
Discharge Port
(2.56)
Position .2 )
22 74
47 .874
(4.189)
(1
106.4
(.8
.6 )
118 )
.
Sq
5
12 92)
"PV2R" Series
(2.311)
.
58.7
( 4
Small Volume Pump
61.9 R9(R.35)
Discharge Port
21(.83) Dia. (2.437) 30.2 "D" Thd. "L" Deep 49(1.93)
"C" Thd. "K" Deep (1.189) 4 Places
4 Places
403
( 2 70
6)
.7
(15.87)
139.5 115.5 112 Suction Port and
(5.49) (4.55) (4.41)
View Arrow X Large Volume Pump
Dia. Discharge Port
75 A Position
(2.95)
31.75(1.2500)
31.70(1.2480)
213
35.32(1.391)
35.14(1.383)
63 (8.39)
(2.48)
181
40 (7.126)
(1.57)
R16
(3.74)
(3.54)
166(6.54) Sq.
95
(R.63)
127.00 Dia.
90
X
(7.20)
183
(5.000)
(4.998)
126.95
(1.22)
31
Dimensions mm (Inches)
Model Numbers "C" Thd. "D" Thd. "J" Thd.
K L
PV2R23-*-*-F-REAA-41 M16 M10 M10 19 (.75) 19 (.75)
PV2R23-*-*-F-REAA-4190 5/8-11 UNC 7/16-14 UNC 3/8-16 UNC 21 (.83) 20 (.79)
DIMENSIONS IN
MILLIMETRES (INCHES)
Foot Mtg.: PV2R23-*-*-L-REAA-41/4190
(4.31)
109.5
23
22
(.08)
2
76.2 88 145
(3.000) (3.46) (5.71)
131 50 117.5 117.5
(5.16) (1.97) (4.626) (4.626)
274
(10.79)
Key Width
Suction Port 21 9
88(3.46) Dia. (.83) (.354)
Small Volume Pump
Discharge Port R11 R17
R11(R.43)
28(1.10) Dia. (R.43) (R.67)
(.3138)
(.3126)
7.97
7.94
65(2.56)
(2.311)
3
58.7
12 4)
8
( .
4
(2.311)
58.7
65(2.56) (4.752)
120.7
69.9
30.2 (2.752) 30.2
(1.189) "D" Thd. "F" Deep
(1.189)
"C" Thd. "E" Deep 4 Places
4 Places
"D" Thd. "F" Deep
4 Places
454(17.87)
(2.95)
56 181(7.126)
31.75(1.2500)
31.70(1.2480)
(2.20)
35.32(1.391)
35.14(1.383)
R16
(3.74)
(3.54)
(3.54)
166(6.54) Sq.
(R.63)
Dia.
95
90
(4.998) 90
183(7.20)
(5.000)
127.00
126.95
(1.22)
31
Dimensions mm (Inches)
Model Numbers "C" Thd. "D" Thd.
E F
PV2R33-*-*-F-RAAA-31 M16 M10 19 (.75) 19 (.75)
PV2R33-*-*-F-RAAA-3190 5/8-11 UNC 7/16-14 UNC 21 (.83) 20 (.79)
DIMENSIONS IN
MILLIMETRES (INCHES)
Foot Mtg.: PV2R33-*-*-L-RAAA-31/3190
454(17.87) 17.5(.689) Dia. Through
26(1.02) Dia. Spotface
136 136 124 4 Places
(5.35) (5.35) (4.88)
217(8.54)
23(.91)
22(.87)
(4.31)
109.5
(.08)
2
Suction Port
Large Volume Pump
Discharge Port
36(1.42) Dia.
B
88(3.46) Dia. 25 13
Key Width
69.9 (.98) (.512)
Small Volume Pump R17
Discharge Port (2.752)
(R.67)
13(.51) Dia.
R8(R.31)
(.3764)
(.3752)
9.56
9.53
(1.500)
(4.752)
120.7
38.1
123 )
(3.82)
"PV2R" Series
4
(4.8
(2.752)
69.9
40(1.57)
17.5
"E" Thd. "J" Deep (.689)
4 Places 35.7
(1.406) "D" Thd. "H" Deep
"C" Thd. "F" Deep 4 Places
R13
4 Places
(R.51)
R37(R1.46)
Port Position
423(16.65)
146.5 119.5 135 A
(5.77) (4.70) (5.31)
24 92 273(10.75) Sq.
(.94) (3.62)
76 228.6(9.000)
(2.99)
Dia.
56
38.10(1.5000)
38.05(1.4980)
(2.20)
42.36(1.668)
42.18(1.661)
(5.51)
140
(4.53)
115
152.40 Dia.
228.6(9.000)
(2.28)
217(8.54)
58
(6.000)
(5.998)
152.35
Dimensions mm (Inches)
Model Numbers "C" Thd. "D" Thd. "E" Thd.
F H J
PV2R14-*-*-F-RAAA-32 M16 M12 M8 19 (.75) 19 (.75) 14 (.55)
PV2R14-*-*-F-RAAA-3290 5/8-11 UNC 1/2-13 UNC 5/16-18 UNC 21 (.83) 21 (.83) 16 (.63)
DIMENSIONS IN
MILLIMETRES (INCHES)
Foot Mtg.: PV2R14-*-*-L-RAAA-32/3290
22(.866) Dia. Through
423(16.65) 43(1.69) Dia. Spotface
146.5 119.5 135 4 Places
(5.77) (4.70) (5.31) A
327.3(12.89)
30(1.18)
29(1.14)
(7.37)
187.3
3(.12)
114.3 99 280(11.02)
(4.500) (3.90)
185 60 187.3 187.3
(7.28) (2.36) (7.374) (7.374)
438(17.24)
Key Width
Small Volume Pump 69.9 (.98) (.512)
Discharge Port R17 (2.752)
19(.75) Dia. (R.67)
(.3764)
(.3752)
R9(R.35)
9.56
9.53
125 Sq.
(1.874)
(4.752)
120.7
47.6
123 )
(4.92)
4
(4.8
(2.752)
69.9
49(1.93)
56
38.05(1.4980)
(2.20)
42.36(1.668)
42.18(1.661)
(5.51)
140
(4.53)
115
228.6(9.000)
(2.76)
Dia.
217(8.54)
70
(6.000)
(5.998)
152.40
152.35
Dimensions mm (Inches)
Model Numbers "C" Thd. "D" Thd. "E" Thd.
F H
PV2R24-*-*-F-RAAA-31 M16 M12 M10 19 (.75) 19 (.75)
PV2R24-*-*-F-RAAA-3190 5/8-11 UNC 1/2-13 UNC 3/8-16 UNC 21 (.83) 21 (.83)
DIMENSIONS IN
MILLIMETRES (INCHES)
Foot Mtg.: PV2R24-*-*-L-RAAA-31/3190
22(.866) Dia. Through
462(18.19) 43(1.69) Dia. Spotface
4 Places
171.5 119.5 135
(6.75) (4.70) (5.31) A
327.3(12.89)
30(1.18)
29(1.14)
(7.37)
187.3
3(.12)
114.3 99 280(11.02)
(4.500) (3.90)
185 60 187.3 187.3
(7.28) (2.36) (7.374) (7.374)
438(17.24)
Key Width
77.8 25 13
.1 .2
100(3.94) Dia.
58 311
)
E
(1 30
89
(2
(3.063) (.98) (.512)
.7 )
.
.
R17(R.67)
q
4) S
(6 6 6
1
Small Volume Pump
.5
(.3764)
(.3752)
Discharge Port
9.56
9.53
28(1.10) Dia. "J" Thd. "N" Deep
4 Places
152 65(2.56)
8)
"PV2R" Series
(5.9
(2.752)
69.9
(3 90
4)
.5
"C" Thd. "K" Deep 35.7 "D" Thd.
4 Places (1.406) "L" Deep View Arrow X
R37(R1.46) R13(R.51) 4 Places
518(20.39)
228.6(9.000)
(2.20)
38.10(1.5000)
42.36(1.668)
42.18(1.661)
(5.51)
(5.998) 140
(4.53)
115
228.6(9.000)
Dia.
X
(6.000)
152.40
152.35
Dimensions mm (Inches)
Model Numbers "C" Thd. "D" Thd. "J" Thd.
K L N
PV2R34-*-*-F-REAA-31 M16 M12 M8 19 (.75) 19 (.75) 19 (.75)
PV2R34-*-*-F-REAA-3190 5/8-11 UNC 1/2-13 UNC 7/16-14 UNC 21 (.83) 21 (.83) 20 (.79)
DIMENSIONS IN
MILLIMETRES (INCHES)
Foot Mtg.: PV2R34-*-*-L-REAA-31/3190
518(20.39) 22(.866) Dia. Through
43(1.69) Dia. Spotface
192 133 135 4 Places
(7.56) (5.24) (5.31) A
327.3(12.89)
30(1.18)
29(1.14)
(7.37)
187.3
3(.12)
114.3 99 280(11.02)
(4.500) (3.90)
185 60 187.3 187.3
(7.28) (2.36) (7.374) (7.374)
438(17.24)
PV2R12-*-26 PV2R12-*-33
PV2R24-26-* PV2R24-33-*
L/min U.S.GPM L/min
U.S.GPM 60
50 16
13 1800 r/min
1800 r/min
12
14
40 1500 r/min 50 1500 r/min
Output Flow
10
Output Flow
12
1200 r/min 40
8 30 1200 r/min
10
1000 r/min
6 1000 r/min kW HP
20 8 30 30 40
4 HP
kW 30 6 30
20
Input Power
10 20 Input Power 20
20 20
10 10
10 10
0 0 0 0
0 3.5 7 10.5 14 17.5 21 MPa 0 3.5 7 10.5 14 17.5 21 MPa
(1000) (2000) (3000) (PSI) (1000) (2000) (3000) (PSI)
Pressure Pressure
PV2R23-*-52 PV2R23-*-60
PV2R34-52-* PV2R34-60-*
U.S.GPM L/min
L/min
U.S.GPM 30 110
110
28 1800 r/min
100 26 100
24 90 1800 r/min 90
22 1500 r/min
Output Flow
Output Flow
80 80
20 1500 r/min
70 18 70 1200 r/min
16 60 1200 r/min 60
1000 r/min
14 50
50 kW
12
40 10 40 50 HP
1000 r/min
8 30 30 60
kW
HP 40
40 50
50
30 40 30 40
Input Power
Input Power
30 30
20 20
20 20
10 10
10 10
0 0 0
0
0 3.5 7 10.5 14 17.5 21 MPa 0 3.5 7 10.5 14 17.5 21 MPa
(1000) (2000) (3000) (PSI) (1000) (2000) (3000) (PSI)
Pressure Pressure
Typical Pump Characteristics at Viscosity 20 mm2/s (100 SSU) [ISO VG32 Oils, 50°C (122°F)]
B
PV2R23-*-66
PV2R34-66-*
L/min
140
U.S.GPM 130
"PV2R" Series
110
28
100 1500 r/min
Output Flow
24 90 HP
80 1200 r/min kW
20 70
70 50
1000 r/min
16 60 60
50 40
12 50
40
Input Power
30 40
30
20
20
10
10
0 0
0 3.5 7 10.5 14 17.5 21 MPa
(1000) (2000) (3000) (PSI)
Pressure
PV2R12-*-*-*-REAA-42/4290
PV2R13-*-*-*-RAAA-42/4290
PV2R23-*-*-*-REAA-41/4190
PV2R33-*-*-*-RAAA-31/3190
3 15 14 9 6 1 5 8 10 11 21 2 18 7 4 20
24
23
22
27
26
25
Cartridge Kits
Cartridge Kit Numbers Cartridge Kit Numbers
Model Numbers 6 Small Volume 5 Large Volume Model Numbers 6 Small Volume 5 Large Volume
Pump Pump Pump Pump
PV2R12-6- -*-REAA-42* CPV2R13-6-L-42 PV2R13-6- -*-RAAA-42* CPV2R13-6-L-42
PV2R12-8- -*-REAA-42* CPV2R13-8-L-42 PV2R13-8- -*-RAAA-42* CPV2R13-8-L-42
PV2R12-10- -*-REAA-42* CPV2R13-10-L-42 PV2R13-10- -*-RAAA-42* CPV2R13-10-L-42
PV2R12-12- -*-REAA-42* CPV2R13-12-L-42 PV2R13-12- -*-RAAA-42* CPV2R13-12-L-42
PV2R12-14- -*-REAA-42* CPV2R13-14-L-42 CPV2R2 PV2R13-14- -*-RAAA-42* CPV2R13-14-L-42 CPV2R3
PV2R12-17- -*-REAA-42* CPV2R13-17-L-42 - -R-41 PV2R13-17- -*-RAAA-42* CPV2R13-17-L-42 - -R-31
PV2R12-19- -*-REAA-42* CPV2R13-19-L-42 PV2R13-19- -*-RAAA-42* CPV2R13-19-L-42
PV2R12-23- -*-REAA-42* CPV2R13-23-L-42 PV2R13-23- -*-RAAA-42* CPV2R13-23-L-42
PV2R12-25- -*-REAA-42* CPV2R13-25-L-42 PV2R13-25- -*-RAAA-42* CPV2R13-25-L-42
PV2R12-31- -*-REAA-42* CPV2R13-31-L-42 PV2R13-31- -*-RAAA-42* CPV2R13-31-L-42
PV2R23-41- -*-REAA-41* CPV2R23-41-L-41 PV2R33-76- -*-RAAA-31* CPV2R33-76-L-31
CPV2R33
PV2R23-47- -*-REAA-41* CPV2R23-47-L-41 PV2R33-94- -*-RAAA-31* CPV2R33-94-L-31
CPV2R3 - -R-31
PV2R23-53- -*-REAA-41* CPV2R23-53-L-41 PV2R33-116- -*-RAAA-31* CPV2R33-116-L-31
- -R-31
PV2R23-59- -*-REAA-41* CPV2R23-59-L-41 Note: The marks are a spaces for large volume pump nominal
PV2R23-65- -*-REAA-41* CPV2R23-65-L-41 displacement. Referring to the model No. designation on
page 181, write the correct nominal displacement figures.
PV2R14-*-*-*-RAAA-32/3290
PV2R24-*-*-*-RAAA-31/3190 B
PV2R34-*-*-*-REAA-31/3190
3 25 21 20 13 6 29 1 5 12 18 16 2 17 19 35 27 24 11 26 4
"PV2R" Series
32
34
31
30
28
36
Cartridge Kits
Cartridge Kit Numbers Cartridge Kit Numbers
Model Numbers 6 Small Volume 5 Large Volume Model Numbers 6 Small Volume 5 Large Volume
Pump Pump Pump Pump
PV2R14-6- -*-RAAA-32* CPV2R13-6-L-42 PV2R24-26- -*-RAAA-31* CPV2R23-26-L-41
PV2R14-8- -*-RAAA-32* CPV2R13-8-L-42 PV2R24-33- -*-RAAA-31* CPV2R23-33-L-41 CPV2R4
PV2R14-10- -*-RAAA-32* CPV2R13-10-L-42 PV2R24-41- -*-RAAA-31* CPV2R23-41-L-41 - -R-30
PV2R14-12- -*-RAAA-32* CPV2R13-12-L-42 CPV2R2 PV2R24-47- -*-RAAA-31* CPV2R23-47-L-41
PV2R14-14- -*-RAAA-32* CPV2R13-14-L-42 - -R-41 PV2R34-52- -*-REAA-31* CPV2R33-52-L-31
PV2R14-17- -*-RAAA-32* CPV2R13-17-L-42 PV2R34-60- -*-REAA-31* CPV2R33-60-L-31
PV2R14-19- -*-RAAA-32* CPV2R13-19-L-42 PV2R34-66- -*-REAA-31* CPV2R33-66-L-31 CPV2R34
PV2R14-23- -*-RAAA-32* CPV2R13-23-L-42 PV2R34-76- -*-REAA-31* CPV2R33-76-L-31 - -R-31
Note: The marks are a spaces for large volume pump nominal PV2R34-94- -*-REAA-31* CPV2R33-94-L-31
displacement. Referring to the model No. designation on PV2R34-116- -*-REAA-31* CPV2R33-116-L-31
page 181, write the correct nominal displacement figures.
Graphic Symbol
1. In case of using socket welding flanges, there is a case where the operating pressure should be set lower than the normal because of strength of the
flanges. Therefore, please pay cautious attention to the operating pressure when the socket welding flanges are used.
2. As dimensions of the pipe flange mounting surface are conformed to SAE 4 Bolt Split Flange (Standard Pressure Series), pipe flanges conforming to
the SAE Standards can be used.
Notes: Special seals (Viton seals) are required when phosphate ester type fluids are used. (Prefix "F-" to the pipe flange kit number when ordering.)
Details of the pipe flange kits are shown on page 824.
Specifications
Maximum Operating Pressure
Model
Petroleum Base Oils
Max. Operating Pressure MPa (PSI)
Water Containing Fluids Synthetic Fluids
B
Numbers 1
Anti-Wear
Water in Oil
Anti-Wear Type R & O Type Type Water Water Glycols Phosphate Esters
Emulsions
Glycols
PV2R24A-26
PV2R24A-33
"PV2R24A/34A" Series
PV2R24A-41
Output Flow & Input Power, Shaft Speed Range and Mass
Shaft Speed Range r/min
Approx. Mass
Model Output Flow & Input Power Water Containing Fluids
Petroleum Base Oils kg (lbs.)
Numbers Phosphate Esters
Small Volume Pump Large Volume Pump Max. Min. Max. Min. Flange Mtg. Foot Mtg.
If the pump is used at speed above 1400 r/min, the suction pressure is limited to 0 kPa (0 in. Hg.).
Key Width
Discharge Port Discharge Port Position
E
Y
Suction Port
6)
88(3.46) Dia. 21 9
.7
9.56(.3764)
9.53(.3752)
(2
R17(R.67) R14(R.55) (.83) (.354)
12 .92
70
5 )
(4
)
74
sq
(.8
.
.2
22
47 874
(1
(4.752)
.6 )
(2.752)
.
120.7
69.9
12 4)
8
(4. 49
(1.93) "E" Thd.
76(2.99) 17(.67) Deep
R9
4Places
69.9 (R.35)
(2.752) 35.7 "D" Thd. "H" Deep
Small Volume Pump
(1.406) 4 Places View Arrow X View Arrow Y
Discharge Port "C" Thd. "F" Deep
19(.75) Dia. 4 Places
(3.35) 181
72.5 (7.126)
38.10(1.5000)
38.05(1.4980)
42.36(1.668)
42.18(1.661)
(2.85)
56
135.5
(5.33)
(2.20)
(4.33)
235.5(9.27)
110
160(6.30) Sq.
127.00 Dia.
(1.22)
(5.000)
(4.998)
31
126.95
R16
(R.63)
17.5(.689) Dia. Through
4 Places 148
(5.83)
Dimensions mm (Inches)
Model Numbers "C" Thd. "D" Thd. "E" Thd.
F H
PV2R24A-*-*-F-REAA-10 M16 M14 M10 19 (.75) 22 (.87)
PV2R24A-*-*-F-REAA-1090 5/8-11 UNC 1/2-13 UNC 3/8-16 UNC 21 (.83) 21 (.83)
DIMENSIONS IN
MILLIMETRES (INCHES)
Foot Mtg.: PV2R24A-*-*-L-REAA-10/1090
17.5(.689) Dia. Through
26(1.02) Dia. Spotface
4 Places
A
(9.63)
244.5
22(.87)
23(.91)
(4.31)
109.5
(.08)
2
76.2 98 145(5.71)
(3.000) (3.86)
131 60 117.5 117.5
(5.16) (2.36) (4.626) (4.626)
274
(10.79)
Key Width
100(3.94) Dia. Discharge Port
Small Volume Pump 36(1.42) Dia.
Discjarge Port
21 9
28(1.10) Dia. (.83) (.354)
9.56(.3764)
9.53(.3752)
R16 R14
R11(R.43) (R.63) (R.55)
"PV2R24A/34A" Series
130.2(5.126)
(2.752)
2
58.7
69.9
15 8)
5 .9
(
76(2.99)
65 30.2 77.8 35.7 "D" Thd. "L" Deep
(2.56) (1.189) (3.063) (1.406) 4 Places
"J" Thd. "N" Deep "C" Thd. "K" Deep
4 Places 4 Places
480.5(18.92)
Port Position
142 148 133 A
(5.59) (5.83) (5.24) 213
85
(8.39)
Dia.
(3.35) 181
72.5
(7.126)
38.10(1.5000)
38.05(1.4980)
(2.85)
42.36(1.668)
42.18(1.661)
56
135.5(5.33)
(2.20)
110(4.33)
(3.54)
235.5(9.27)
160(6.30) Sq.
90
Dia.
(1.22)
(5.000)
(4.998)
31
127.00
126.95
R16
(R.63)
17.5(.689) Dia. Through
2 Places 148
(5.83)
Dimensions mm (Inches)
Model Numbers "C" Thd. "D" Thd. "J" Thd.
K L N
PV2R34-*-*-F-RAAA-10 M16 M14 M10 19 (.75) 22 (.87) 19 (.75)
PV2R34-*-*-F-RAAA-1090 5/8-11 UNC 1/2-13 UNC 7/16-14 UNC 21 (.83) 21 (.83) 20 (.79)
DIMENSIONS IN
MILLIMETRES (INCHES)
Foot Mtg.: PV2R34A-* -* -L-RAAA-10/1090
17.5(.689) Dia. Through
26(1.02) Dia. Spotface
4 Places
A
(9.63)
244.5
23(.91)
22(.87)
(4.31)
109.5
(.08)
2
76.2 98 145
(3.000) (3.86) (5.71)
131 60 117.5 117.5
(5.16) (2.36) (4.626) (4.626)
274
(10.79)
PV2R24A-*-*-*-REAA-10/1090
PV2R34A-*-*-*-RAAA-10/1090
14 3 13 12 8 1 9 20 11 15 16 2
19
6
18 10
17 21
24
23
Cartridge Kits
Cartridge Kit Numbers
Model Numbers 8 Small Volume 9 Large Volume
Pump Pump
PV2R24A-26- -*-REAA-10* CPV2R23-26-L-41
PV2R24A-33- -*-REAA-10* CPV2R23-33-L-41
PV2R24A-41- -*-REAA-10* CPV2R23-41-L-41
PV2R24A-47- -*-REAA-10* CPV2R23-47-L-41 CPV2R4A- -R-10
PV2R24A-53- -*-REAA-10* CPV2R23-53-L-41
PV2R24A-59- -*-REAA-10* CPV2R23-59-L-41
PV2R24A-65- -*-REAA-10* CPV2R23-65-L-41
PV2R34A-76- -*-REAA-10* CPV2R33-76-L-31
PV2R34A-94- -*-REAA-10* CPV2R33-94-L-31 CPV2R34A- -R-10
PV2R34A-116- -*-REAA-10* CPV2R33-116-L-31
Note: The marks are a spaces for large volume pump nominal displacement. Referring to
the model No. designation on page 196, write correct nominal displacement figures.