POWER SYSTEM QUALITY AND CONTROL

YELLOWE, KENOBI MIKE 159043054 UTHMAN, JIMOH 159043002 UGWUAGBO, EMENIKE CHRISTIAN 159043055
S No. NAME(S) OF JOURNAL NAME, Vol., TITLE OF PAPER PROBLEM METHOD USED WEAKENESS(ES) STRENGTH OF THE REMARK
AUTHORS No., DATE, Pg. STATEMENT OF THE APPROACH (GAP NOT
APPROACH FILLED BY
THE WORK)
1 Ajitha priyadarsini IJRET: International Journal Load Frequency Control In suppression of fuzzy logic controller fuzzy logic controller is very
.S, P. Melba Mary of Research in Engineering Co-Ordination With oscillations in multi-area effective enhancing better
and Technology Frequency Controllable Hvdc power systems damping performance in
Links Using Fuzzy Logic non-linear conditions
Controller
2 John J. Paserba, IEEE How FACTS Controllers
Benefit
AC Transmission Systems
3 Zhong yun, Jiang 2010 2nd International Simulation of Vector Control control speed and discrete the simulation results show
Qiangxin, Wu Conference on Signal and Variable Frequency Asynchronous Machine vector of flux closed-loop that the validity and
weiling Processing Systems (ICSPS) Regulating System of discrete reliability of parameters
Asynchronous Machine Based regulating, speed
on MATLAB regulating performance and
dynamic performance are all
enhanced
4 IJRET: International Journal PWM GENERATION TO CONTROL perfect square wave
Ananya Devraj1, of Research in Engineering CONTROL VARIABLE VARIABLE Pulse Width Modulation The memory used in
Darshan R2 and Technology eISSN: FREQUENCY POWER FREQUENCY POWER this case is a Read Only
2319-1163 | pISSN: 2321- SOURCE SOURCE Memory (ROM) that
7308 additional power quality uses Look-Up-Table
problems
5 Akanksha Sharma1, International Journal of Automatic Generation Control Automatic Generation back propagation algorithm The ANN
K.P. Singh Parmar2 Computer Science and of Multi Area Power Control (AGC) of a five is used as neural network controller gives much better
and Dr. S.K. Telecommunications System using ANN Controller area interconnected learning rule results as compared to that of
Gupta3 [Volume 3, Issue 3, March power system with Integral controller.
2012] reheat turbines.
6
7 Atle Rygg Årdala*, SciVerse ScienceDirect Voltage and frequency control improve the voltage and Voltage and frequency Voltage Source Converters
Tore Undelandb, Energy Procedia 24 ( 2012 ) in offshore wind turbines frequency stability in control (VSCs) can
Kamran 229 – 236 connected to isolated oil offshore improve the power system
Sharifabadic platform power systems oil and gas installations. stability in oil and gas
platforms.
8 Zhuang Xu* SciVerse ScienceDirect Power Flow Control of High power flow control of The capability of
Energy Procedia 75 ( 2015 ) Voltage DC Networks for multi-terminal high voltage the control strategies to
1698 – 1704 Grid High Voltage DC DC networks (MTDC) perform three market
Integration of Networks for Grid dispatch schemes (
Offshore Wind Power Integration of Offshore
Wind Power

9 M. Elsisi, M. GSA-Based Design of Dual generation rate gravitational optimize the


Soliman, M. A. S. World Academy of Science, Proportional Integral constraint (GRC) search algorithm AGC in a two-area
Aboelela, W. Engineering and Technology Load Frequency Controllers and governor dead band interconnected power
Mansour Vol:9 2015-08-01 for Nonlinear are considered system.
Hydrothermal Power System
10 Wei Pana, Ye SciVerse ScienceDirect Online fault diagnosis for exploiting the sparse nature sparse signal recovery for the
Yuanb,1, Henrik Automatica 55 (2015) 27–36 nonlinear power systems automatic fault of the fault-diagnosis
Sandberg c, Jorge diagnosis for faults
Gonçalves b,d, transmission lines in
Guy-Bart Stan a large scale
power networks.
11 Bindeshwar Singh, International Journal of Introduction to FACTS enhancement of the current status on
K.S. Verma, Pooja Automation and Power Controllers: A performance parameters application
Mishra, Rashi Engineering Volume 1 Issue Technological Literature of power systems of FACTS controllers in PSs
Maheshwari, 9, December 2012 Survey such as reactive power for enhancement of
Utkarsha support, minimize the performance parameters of
Srivastava, and real power systems
Aanchal losses, improvement in
Baranwal voltage profile,
improvement in
damping ratio of power
systems, provide the
flexible
operation and control
12 Tarik Zabaiou1, Preventive control approach novel voltage stability enhance the power system technique could
Louis-A Dessaint1, for voltage stability constrained optimal power voltage security by be easily
Innocent Kamwa2 improvement using voltage flow (VSC-OPF) improving the system combined with
stability constrained voltage stability and other stability
optimal power flow based on minimising the constraints such
www.ietdl.org static line voltage power losses as the
stability indices transient stability
voltage stability or the small
improvement using signal stability
voltage stability and could be
constrained implemented in
multi-objective
optimisation
problems
13 Cong-Hui Huang ournal􀀃of􀀃Applied􀀃Research Modified Neural Network for Neural Network for Radial Basis Function modified neural network for
􀀃and􀀃Technology Dynamic Control and Dynamic Control and Network (RBFN) and an dynamic control and
Operation of a Operation of a modified Elman Neural operation of a hybrid
Hybrid Generation Systems Hybrid Generation Network (ENN) for generation systems.
Systems maximum power point
tracking (MPPT).
14 Imran Khan, M.A. SciVerse ScienceDirect Optimal placement of FACTS improve the static voltage
Mallick, Malik Journal of Electrical Systems controller scheme for stabilitymargin measured in
Rafi, Mohammad and Information Technology enhancement ofpower system terms of the critical loading
Shadab Mirza∗ 2 (2015) 161–171 security in Indian scenario value for the system intact as
enhancement of power Line overloads are solved well as for the critical
system security by controlling active power contingency cases
of series compensators and
low voltages are solvedby
controlling reactive power
of shunt compensators,
respectively

15 E. Haesen, J. IEEE Robust planning methodology integration traditional mathematical the algorithm will
Driesen and R. for integration of stochastic generators optimisation of techno- be applied to
Belmans in distribution grids economic objectives planning
of stochastic generators in problems in MV
distribution grids cope with the wide variety of grids to improve
stochastic distributions reliability
concerning DG concerning
production, load profiles and dispatchable
grid topology. units, long-term
planning issues
(load growth,
fuel prices) and
grid stability.
16 Lorenzo Damiani*, SciVerse ScienceDirect Simulation of a Power power regulation system the bypass of the low the limited thermo-
Alessandro Pini Regulation System for Steam for coal power plants pressure pre-heaters in mechanical stress
Prato Power Plants order to increase the steam induced in the pre-heaters
flow-rate in turbine
17 Y. M. Atwa, E. F. IEEE TRANSACTIONS ON Optimal Renewable Renewable Resources regardless
El-Saadany, M. M. POWER SYSTEMS, VOL. Resources Mix for Mix for Distribution of the combination of the
A. Salama,, R. 25, NO. 1, FEBRUARY Distribution System Energy Loss renewable resources used to
Seethapathy, 2010 System Energy Loss Minimization calculate
Minimization the optimal fuel mix, there is
a significant reduction in the
probabilistic annual energy loss for all
planning technique scenarios proposed
18 Yongjie FANG J. Mod. Power Syst. Clean Reflections on stability reducing risk of system comparative analysis real-time operational
Energy (2014) 2(3):264–271 technology for reducing risk collapse due to management of emergency
DOI 10.1007/s40565-014- of system cascading outages control measures and
0067-x collapse due to cascading improvement of simulation
outages accuracy
19 IJRET: International Journal
Feba Thamar of Research in Engineering LOAD FREQUENCY Maximum Power Point modified hill climbing Transfer function model of
Tomy1, R.Prakash2 and Technology eISSN: CONTROL OF A TWO Tracking is performed in algorithm( the thermal generator is
2319-1163 | pISSN: 2321- AREA HYBRID SYSTEM photovoltaic combining fuzzy logic with interfaced with the
7308 CONSISTING OF A GRID hill climbing algorithm) photovoltaic system to create
CONNECTED PV SYSTEM two area systems. Load
AND THERMAL frequency controls of this
GENERATOR two area system are
performed.
20 D. H. Spatti, I. N. IEEE LATIN AMERICA Fuzzy Control System for Voltage Regulation fuzzy control strategy limited to the power
da Silva, W. F. TRANSACTIONS, VOL. 8, Voltage Regulation In Power Transformers distribution substation,
Usida and R. A. NO. 1, MARCH 2010 In Power Transformers and both the voltage
Flauzino, measurements and
control actions are
carried out on the
secondary bus
21 FELIX F. WU, THE IEEE, VOL. 93, NO. Power System Control Power System Control
FELLOW, 11, NOVEMBER 2005 Centers: Past, Present, Centers
KHOSROW and Future
MOSLEHI, AND
ANJAN BOSE
22 Preeti Hooda et al Int. PI Controller with better performance than
Preeti Hooda, Journal of Engineering Automatic Generation Control Automatic Generation Bacterial Foraging conventional Proportional
Dr.Leena.G, Anita Research and Applications Using PI Controller with Control for Thermal and integral controller.This
Khosla www.ijera.com ISSN : 2248- Bacterial Foraging for both Hydro Plants method reduces the peak
9622, Vol. 4, Issue 6 Version Thermal and Hydro Plants deviation in frequencies
1), June 2014, pp.113-118 andimproves the tie line
power
23 H. Azani 1,2, A. IEEE Multiloop Control Strategy difficult to stabilize, the
Massoud 1, L. Ben- for Grid-Interfaced Three- conventional third order performance of the high-
Brahim 1, Phase Voltage LCL filter, the high order LLCL-filter with RC
B. W. Williams 2, Source Inverter with order LLCL Passive damping passive
and D. Holliday Passively Damped LLCL- filter techniques damping circuit through
Filter evaluating the system
stability using
dual-loop control strategy
that has been applied to the
LCLfilter
24 Jun Zhang, Xihuai SciVerse ScienceDirect Multi-machine Power System decentralized robust nonlinear robust control the nonlinear robust
Wang and Jianmei Procedia Environmental Robust Excitation Control control and improve theory excitation controller is very
Xiao Sciences 10 ( 2011 ) 350 – stability of the system effective for the
355 improvement of system
stability and
disturbance attenuation
compared with the PSS and
the traditional PID controller.
25 Basit, Abdul; The Journal of Engineering; Wind power integration into coordinated control coordinated control strategy
Hansen, Anca Received on 13th August the automatic generation strategy for the AGC for the AGC between
Daniela; Altin, 2014; Accepted on 20th control of power systems with the power combined
Müfit; Sørensen, August 2014 large-scale wind power balance control of power heat and power plants
Poul Ejnar; Gamst, systems with large wind (CHPs) and WPPs to
Mette power penetration enhance the security and the
reliability of a power system
operation in the case of a
large
wind power penetration
26 Yihua Hu, Weidong Three-Port DC–DC Converter novel three-port dc–dc The developed technology is
Xiao, Wenping for Stand-Alone converter capable of achieving MPPT,
Cao, , Photovoltaic Systems for stand-alone PV high conversion ratio, and
Bing Ji, and D. IEEE TRANSACTIONS ON systems, based on an multiple operating modes,
John Morrow, POWER ELECTRONICS, System efficiency and improved Flyback- while still
VOL. 30, NO. 6, JUNE 2015 cost effectiveness of Forward topology making the converter
photovoltaic (PV) relatively simple, light,
systems efficient, and costeffective.
27 Load Frequency Control in decentralized control Two Area Power System
Prof. Prafulla National Institute of Two Area Power System scheme
Chandra Panda, Technology, Rourkela
Siddhahast
Mohapatra
28 Qingzeng Yan, IEEE TRANSACTIONS ON Minimization of the DC solution to minimize the
Xiaojie Wu, Xibo POWER ELECTRONICS, Component dc component
Yuan, Yiwen Geng, VOL. 30, NO. 7, JULY 2015 in Transformerless Three- in three-phase ac
and Qi Zhang Phase currents and developed a
Grid-Connected Photovoltaic software-based accurate extraction of
Inverters approach to mimic the the dc component based on
blocking capacitors double time integral

29 Biplab ScienceDirect, Ain Shams UPFC with series and shunt minimization of Genetic Algorithm (GA) performance is improved
Bhattacharyya *, Engineering Journal (2014) FACTS controllers transmission loss and and Differential Evolution with
Vikash Kumar 5, 775–787 for the economic operation of simultaneous reduction (DE) technique the use of UPFC along with
Gupta, Sanjay a power in the other series and shunt
Kumar system operating cost of the FACTS controller is
system using Flexible illustrated.
AC Transmission
System (FACTS)
devices.
30 Adria Marcos- Loss-Free Resistor-Based bridgeless rectifier type is the application
Pastor, Enric Vidal- Power Factor Correction composed of two of sliding-mode control by
Idiarte, Angel Cid- Using a Semi-Bridgeless different boost cells which means of hysteretic
Pastor, Boost Rectifier operate complementarily controllers results
and Luis Mart´ınez- in Sliding-Mode Control during each in a first-order stable system
Salamero, loss-free resistor based half-line cycle that can mitigate these
on a semibridgeless harmful consequences
IEEE TRANSACTIONS ON rectifier due to its capability to ensure
POWER ELECTRONICS, the symmetry of the line
VOL. 30, NO. 10, input current waveform for
OCTOBER 2015 both positive and negative
half-line
cycles.
31 Samir M. Al Journal of Power and Energy Control of Instable Chaotic Instable Chaotic Small linear state feedback the linear controller
Shariff1*, Ahmad Engineering, 2015, 3, 1-7 Small Power Power controller stabilizes the system by
M. Harb2 Published Online February System System eliminating all
2015 in SciRes. chaotic oscillations. Hence,
http://www.scirp.org/journal/ the system became
jpee completely stable over the
http://dx.doi.org/10.4236/jpe whole range of the control
e.2015.32001
32 Rajiv K. Varma, , IEEE TRANSACTIONS ON New Control of PV Solar improving stable power novel concept of utilizing
Shah Arifur POWER DELIVERY, VOL. Farm as STATCOM transfer limits of the a photovoltaic (PV) solar
Rahman, , and Tim 30, NO. 2, APRIL 2015 (PV-STATCOM) for interconnected farm inverter as
Vanderheide, Increasing Grid Power transmission system STATCOM, called
Transmission Limits During PV-STATCOM
Night and Day
33 RAGHAVENDRA Online voltage estimation and the estimation based on maximum Comparative results show
P1, D. N. control for smart distribution of voltage profile in a and minimum voltage that RTUs
GAONKAR1 J. Mod. Power Syst. Clean networks smart distribution estimation by remote estimated values are almost
Energy (2016) 4(1):40–46 network withDGfor terminal units matching with
DOI 10.1007/s40565-016- the online voltage (RTUs) placed only at DG backward/forward
0187-6 control connected bus and at sweep load flow method
capacitor
connected bus.
34 José G. de Matos, Power Control in AC Isolated control controlling the power The proposed strategy
Felipe S. F. e Silva, Microgrids the generated power generated by the calculates the amount
and With Renewable Energy from energy sources energy sources dump loads of power that must be
Luiz A. de S. Sources and existing in autonomous or generated at each time by
Ribeiro, IEEE TRANSACTIONS ON Energy Storage Systems and isolated microgrids. any physical each source in
INDUSTRIAL communication among the order to keep the balance of
ELECTRONICS, VOL. 62, power electronic energy into the microgrid. In
NO. 6, JUNE 2015 converters or the individual other
energy source controllers words, the sum of the
generated, consumed, and
stored energy
must always be zero all the
time.
35 Fengjiang Wu, Bo IEEE TRANSACTIONS ON Online Variable Topology- compared with the H- derived expressions of the operation range of CM-
Sun, Jiandong INDUSTRIAL Type Photovoltaic bridge inverter, the the total loss and grid GCI is wider while the
Duan, and Ke Zhao ELECTRONICS, VOL. 62, Grid-Connected Inverter current total harmonics efficiency is
NO. 8, AUGUST 2015 distortions
operation range of the of cascaded inverter and H- lower. An OVT-GCI based
cascaded inverter is bridge inverter under the on CM-GCI is proposed to
wider, whereas conditions increase
the total loss is larger of variable output voltage the European efficiency
and power of the PV array
36 Jie YAN, J. Mod. Power Syst. Clean Risk assessment framework power systems against The 1) For a large cyber significant contributions to
Manimaran Energy (2015) 3(3):321–331 for power control systems cyber attacks duality element relative system with numerous the
GOVINDARASU, with PMU-based fuzzy evaluation, risk security development of a more
Chen-Ching LIU, intrusion response system assessment framework vulnerabilities, reliable and secure power
Ming NI (&), DERFEM may not be grid.
Umesh VAIDYA sufficient. Some
statistical analysis
techniques may be
coupled with DERFEM
to improve evaluation
results.
2) A dedicated control
strategy will be
developed in IRS
for control actions to
prevent voltage
instability. The
voltages are over 1.2
after 1.8 s in Fig. 7d. It
is because IRS
employs a control
action on a simplified
excitation system.
37 Scientific Research
Tamilmaran doi:10.4236/sgre.2011.24035 Smart Grid: An evolution of Smart Grid Smart Grid is important as it
Vijayapriya1*, Published Online November Overview development will take us towards energy
Dwarkadas 2011 independence and
Pralhadas Kothari2 environmentally sustainable
economic growth
38 Zohaib Akhtar, IEEE TRANSACTIONS ON Primary Frequency Control Primary Frequency Reactive Compensation 1) the rating (which dictates
Balarko Chaudhuri, SMART GRID Contribution From Control Contribution the cost and size) of the
and Shu Yuen Ron Smart Loads Using Reactive From reactive compensator and 2)
Hui, Compensation Smart Loads the range of variation in
voltage
across the NC load
connected in series with the
compensator.
39 Hyuntae Choi, Performance of Medium- medium-voltage (MV) the steadystate
Mihai Ciobotaru, Voltage DC-Bus PV System dc-bus PV system and dynamic performance of
Minsoo Jang, Architecture Utilizing High- architecture the PV system architecture.
and Vassilios G. Gain DC–DC Converter based The performance of the
Agelidis, MPPT controller under
IEEE TRANSACTIONS ON high-gain soft-switched rapidly changing
SUSTAINABLE ENERGY, interleaved boost (SSIB) solar irradiation conditions
VOL. 6, NO. 2, APRIL 2015 dc–dc and the operation of the
converter SSIB
converter were confirmed.
40 Bogdan ScienceDirect, Electric Three-level coordination in the synthesis of power interactions synthesis technique with
Marinescua,b,∗ , Power Systems Research 111 power system stabilization system stabilizers of the dynamics of the better
David Peteschc,1 (2014) 40–51 (PSSs) and speed power system
governors performances if new
structures (like, e.g., state-
space forms) are
allowed for the regulators
instead of the actual standard
ones. From
this point of view, the
methodology presented here
is an open
framework.
41 Welflen Ricardo IEEE TRANSACTIONS ON The Transformerless Single- Harmonic and Reactive universal active filter for The steady-state analysis is
Nogueira Santos, POWER ELECTRONICS, Phase Universal Power Compensation harmonic also presented
Edison Roberto VOL. 29, NO. 7, JULY 2014 Active Power Filter for and reactive power in order to demonstrate the
Cabral da Silva, Harmonic and Reactive compensation for single- possibility to obtain an
Cursino Brand˜ao Power Compensation phase systems optimum
Jacobina, applications. voltage angle reducing the
Eisenhawer de current amplitude of both
Moura Fernandes, series and
Alexandre Cunha parallel converters and,
Oliveira, consequently, the total losses
Rafael Rocha of the system.
Matias, Dalton
Franc¸a Guedes
Filho, Otac´ılio M.
Almeida, and
Patryckson
Marinho Santos
42 Changhong Zhao, IEEE TRANSACTIONS ON Design and Stability of Load- Load-Side Primary systematic method rebalance
UfukTopcu, NaLi, AUTOMATIC CONTROL, Side Primary Frequency Control in power and resynchronize bus
and VOL. 59, NO. 5, MAY 2014 Frequency Control in Power Power Systems frequencies after a
Steven Low, Systems disturbance
with significantly improved
transient performance.
43 Divya Asijaa, ScienceDirect, Procedia Performance Evaluation and Power World Simulator during the
Pallavi Computer Science 70 ( 2015 Improvement in Transient fault if we use the excitation
Choudekarb*, ) 733 – 739 Instability of system, then we can easily
Ruchirac†, Malvika IEEE 9 bus System using control the voltage and
Chouhand exciter and governor control the designing and system power and can
improvement in protect the
“Transient whole system from transient
Stability of IEEE 9 Bus instability.
Test System
44 Abdelmoume`ne ScienceDirect, Ain Shams Load frequency control Automatic Generation robust Fractional Order robustness analysis
Delassi *, Salem Engineering Journal (2015) problem in interconnected Control PIkD controller against higher degree of load
Arif 1, Lakhdar power systems using robust (AGC) of a three areas disturbance and sever
Mokrani 2 fractional PIkD reheat-thermal system parametric variation
controller demonstrates the
effectiveness of the
investigated controller.