Dik reservoir data:

q 50 STB/D
ct 0.00001 psi
μ 0.15 cp
re 1000 f
B 1.25 RB/STB
rw 0.25 f
k 5 mD
s 4.5
Pi 3500 psi
φ 0.2
h 50 f
Calculate the time at which the Ei function comes be valid

a. 0.001491

Calculate the time after which the Ei function solution is no longer valid

b. 56.88

Calculate and plot the pressure as a function of position on semilograph

c. r 0.25 r 50 r 300
t 5 t 5 t 5
x 0.000000711 x 0.02844 x 1.02384
p 3464.047881 p 3492.028 p 3499.442

r 1 r 100 r 400
t 5 t 5 t 5
x 0.000011376 x 0.11376 x 1.82016
p 3471.38831 p 3495.481 p 3499.834

r 2 r 150 r 500
t 5 t 5 t 5
x 0.000045504 x 0.25596 x 2.844
p 3475.058524 p 3497.283 p 3499.958

r 10 r 200 r 750
t 5 t 5 t 5
x 0.0011376 x 0.45504 x 6.399
p 3483.580498 p 3498.364 p 3499.999

r 20 r 250 r 1000
t 5 t 5 t 5
x 0.0045504 x 0.711 x 11.376
p 3487.250712 p 3499.03 p 3500

Calculate the additional pressure drop due to the skin factor

d.
r 0.25
t 5
x 0.000000711
p 3440.220381
nilai f(x)>0.01

r x x1 x2 f(x1) f(x2) f(x)


50 0.02844 0.028 0.029 3.026 2.992 3.01104
100 0.11376 0.113 0.114 1.713 1.705 1.70692
150 0.25596 0.25 0.26 1.044 1.014 1.02612
200 0.45504 0.45 0.46 0.625 0.611 0.617944
250 0.711 0.71 0.72 0.367 0.36 0.3663
300 1.02384 1.02 1.03 0.212 0.209 0.210848
400 1.82016 1.82 1.83 0.0629 0.062 0.062886
500 2.844 2.8 2.9 0.0169 0.0148 0.015976
750 6.399 6.3 6.4 0.000228 0.000203 0.000203
1000 11.376 0 0 0 0 0

r(x) P (y) 4000


0.25 3356.192
1 3385.553
2 3400.234
10 3434.322
20 3449.003
50 3468.113 3500
100 3481.924
150 3489.133
200 3493.456
250 3496.121

3000
0 200 400 600 800 1000 1200
300 3496.767
400 3499.334
3000
500 3499.831 0 200 400 600 800 1000 1200
750 3499.998
1000 3500
00 1200
00 1200