Professional Documents
Culture Documents
h2s Analyzer 903 PDF
h2s Analyzer 903 PDF
Sulphur Analyser
benefits
Optical Tape Counter H2S specific measurement
Optical tape counter ensures exact spacing 16 button IS keypad allows user to configure
Rapid response to both increasing or decreasing
of stains as well as keeping track of tape con- and monitor unit without opening explosion
H2S levels
sumption. Tape life of 5-14 weeks can be ex- proof enclosure.
pected, depending on the application. Low operation and maintenance costs
applications
Capable of measuring total sulphur with the Natural Gas Processing
Multi-Range Capability > H2S Concentration at Plant Inlet
addition of furnace.
Able to monitor H2S and Total Sulphur at different ranges. One > Product Quality at Plant Outlet
analyser can thus provide measurements for two or more differing Natural Gas Pipelines
ranges saving the need for additional instruments. > Product Quality at Custody Transfer Station
Galvanic TAPE ASSURANCE SYSTEM
User Friendly Software Extended Range
Galvanic’s ISO 9001-2001 quality assured tapes work together Synthetic Natural Gas (e.g. Coal Gasification)
Easy-to-use Windows-based PC software with Measures H2S up to 2,000 ppm without adding a dilution system.
with a specially designed mechanical and optoelectronic system to > Catalyst Protection / Product Quality
graphical user interface for monitoring and analyser
ensure smooth and continuous operation. Over-Range Capability Gas Compression (LNG, GTL & NGL)
configuration. Can be used while PC is connected to
front of analyser or remotely via serial link or Ethernet. Wide dynamic range provides measurement of H2S levels well past > Catalyst Protection / Corrosion Control
Enhanced Data-Logging (512 kb) the instrument’s set range. > Product Quality
Petrochemical Feedstock
> Catalyst Protection
Fully Configurable System Advanced Diagnostics Field Other Options > Product Quality
Analyser can be customized to Feedback from Programmable > Custom Shelters: Galvanic offers complete analyser Fuel Cell
customer specific requirements. microprocessors mounted Memory shelters from sun shades to complete buildings.
> PPB measurement of H2S and Sulphur
Configurable features include on sensor block provide Easy to upgrade > Hydrogen shut-off: Allows for automatic hydrogen
stream switching (on demand detailed diagnostics analyser firmware Emission Monitoring
shut off to total sulphur oven when analyser is
or timed sequence), automatic information such as sensor with PC via USB > Stack Analysis
monitoring H2S.
calibration, multi mode H2S - status, tape movement, port or network
total sulphur measurement, tape length remaining, > Additional Stream(s): Can analyse up to 4 streams.
connection.
reference and zero gas test, and low sample pressure and > Custom Sample Systems: Galvanic designs custom
multi-ranging. temperature. sample systems for customer’s specific requirements.
WWW.GALVANIC.COM
Galvanic’s 903 H2S Analyser is an online instrument designed to measure hydrogen sulphide (H2S) and / or total sulphur in gaseous
Specifications streams. A single analyser can be configured to monitor up to four (4) streams. The instrument’s advanced digital colorimetric sensor
measures the rate of darkening caused by the reaction of H2S on white tape impregnated with lead acetate in accordance with ASTM
methods D4084-94, D4323-97 and D4468-95.
Streams One (1) stream (standard), with up to 4 Classifications Class 1, Div 1, Group B,C&D
streams (optional). Each stream includes: Class 1, Div 2, Group B,C&D
H2S analysis run, zero run, reference1 run,
reference2 run, calibration run and total Ambient Temp. 10-50°C (without enclosure)
sulphur run (optional).
Electronics - Dual processor design with intelligent
Multi-Range Each stream can have separate calibra- colorimetric sensor. To achieve greatest
tion coefficient and range of measurement. sensitivity sensor uses 24 bit AD converter
Please consult factory for details. equipped with temperature monitor on sen-
sor block. Sensor automatically calibrates
Tape Life 5-14 weeks, depending on application. on every cycle to prevent drift.
Typical tape life given 3 minute cycle time
- Optical tape counter optimizes tape usage
is 5 weeks. Can be extended to as much 3
and provides exact measurement of tape
months at low concentration.
used. User can program low tape alerts /
Auto / Manual Mode AUTO mode: analyser runs in predefined alarms.
sequence. - Real time clock for accurate event time
stamping.
MANUAL mode: user can force any stream to
run. Software Windows based software for configuration
and monitoring. Software includes advanced
configurable features for stream switching,
Communications / Interface automatic calibration, multi mode H2S and
total sulphur measurement, reference and
zero gas test, and multi-ranging.
Outputs 6 - 4-20mA outputs (isolated and scaled to
range) Humidifier Permeable membrane humidifier system fa-
3 - SPDT alarm relays 5 amps @ 30 VDC cilitates faster response time and eliminates
or 8amps @ 120/240 VAC (up to 3 more moisture carry-over to lead acetate tape.
optional)
Memory Field programmable memory. Firmware for
1 - 3 amp max 35 VDC or 3A 24-280 VAC
unit can be upgraded in the field.
Solenoid Driver (standard), up to 7 more
(optional) Data Logging Up to 10 months of H2S concentration data
1 - USB port logs. 512 Kbytes non-volatile memory for
1 - RS-232 Serial Port data logging and audit trail.
1 - RS-485 isolated serial Port
1 - LAN Port for extended analog outputs Options
1 - Ethernet (optional)
Modbus communication on all ports Total sulphur system, dilution system, high pressure sampling
system, solar power, back panel, low pressure sensor, low hy-
Inputs 8 discrete inputs (4 - Dry contact digital in- drogen sensor, auto-cal, and enclosure / cabinets (temperature
puts & 4 - wet contact digital inputs (12/24 controlled enclosure)
VDC)
2 - 4-20 mA, user selected