You are on page 1of 2

Marotta Controls, Inc.

www.marotta.com
973.334.7800

Marotta Ireland, Ltd.


www.marotta.ie

Marotta U.K. Ltd.


www.marotta.co.uk
M u l t i - Fu n c t i o n Va l v e

Marotta’s Multi-Function Valve (MFV) offers many of the high performance


features demanded by Ion and Hall Thruster satellite and spacecraft propul-
sion systems:

• Normally Closed Isolation demonstrated to internal leakage rates less


than 1x10-5 sccs GHe at pressures of 2.5 bar to 207 bar (36 to 3,000
psia) and temperatures from -54 to 93°C (–65 to 200°F)

• Precise, modulating closed loop pressure/flow regulation (pressure,


flow rate or anode current feedback) from 0 to 80°C (32 to 176°F

• Electronically adjustable set-point demonstrated to mass flow turn-


downs greater than 25 to 1 and pressure reductions from 207 bar to 35
millibar (3,000 to 0.5 psia)

The device can also operate as an open/closed 2-way valve.

Key Features

• Normally closed isolation


• Modulation closed loop pressure
• Electronically adjustable set-point
• Reduces the number of Xenon feed system components
• Reduced weight
• Provides both propellant isolation and precise mass flow delivery
• Sensor feedback
• Magnetostrictive material

Marotta’s Multi Function Valve is ideal for Space applications.

Sample Applications:
• Electric Propulsion • Ground Support
• Cold Gas Propulsion • Human Space Flight
• Pressurization Systems • Launch Vehicles
• Thermal Control • Human Space

Revised 3/15/05
marotta.com
Marotta Controls, Inc.
www.marotta.com
973.334.7800

Marotta Ireland, Ltd.


www.marotta.ie

Marotta U.K. Ltd.


M u l t i - F u n c t i o n Va l v e www.marotta.co.uk

Va l v e S p e c i f i c a t i o n s

Operating and Test Fluids Inert gas, including Xenon, Krypton, Helium,
Nitrogen

Operating Pressure 36 to 2000 psia

Internal Leakage <1 x 10-5 sccs GHe

External Leakage <1 x 10-6 sccs GHe

Flow Rate 0.02 to >25 mg/sec xenon

Power <10 watts typical

Operating Temperature Range 0°C to 80°C (32°F to 176°F)

Internal Leakage Temperature Range -54°C to 90°C (-65°F to 200°F)

Operating Life Cycle >100,000

Weight <318 grams (0.7 lbm)

Random Vibration 23.6 Grms

Contact Us
North America Europe
Marotta Controls, Inc. Marotta Controls, Inc. Marotta Ireland, Ltd. Marotta U.K., Ltd.
Corporate Headquarters 3077 Leeman Ferry Rd., 20 Airways Industrial Estate Cheltenham Trade Park
78 Boonton Avenue Suite A14 Dublin, 17 Cheltenham, Gloucestershire
Montville, NJ 07045-7800 Huntsville, AL 35801 Ireland GL51 8LZ, United Kingdom
(p) 973.334.7800 (p) 256.971.1200 (353) 1.8426688 (44) 1242.548780
(f) 973.334.1219 (f) 256.971.1201 (353) 1.8426020 (45) 1242.224291

marotta.com