You are on page 1of 2

Rewamp/Updrade of Existing Dehydrator

Project Title
and Desalter to Dual Frequency Technology

Client: Equipment: Dual Frequency Desalter

NO LOAD TEST REPORT

Vessel Tag: D28-D-211 LRCII Tag: D28-LRC-211

POWER UNIT DETAILS


Model/No/Part 100 KW ML-2000C/OILDF100PDR6150MINPTCTRTTXXXULCAXXNS/146493
Serial No Power Unit B (Middle): 23631-01A-2
Nominal Voltage 25KVDCpk, Frequency 50/60 Hz
4ADCpk
Phase 3 Internal Frequency 800 – 1600 Hz

SLATE SETTING
Base Frequency 800 Hz Waveform Inv. Circular
Mod Frequency 1 Hz Skew Factor 0.5
Min Voltage 5000 V Ramp Up Time 3s
Max Voltage 5000 V Current Limit 30 A

POWER UNIT SETTING


Secondary Voltage 25 KV Power Rating 100 KW

TEST RESULTS

POWER UNIT NO
POWER UNIT STATUS
OFC FAULTS
OFC RATE (MIN)

FEEDBACK VALUES

BUS CURRENT (A) BUS VOLTAGE (V) POS VOLTAGE (V) NEG VOLTAGE (V)

FEEDBACK VALUES WHEN HEART BEAT DISCONNECT

BUS CURRENT (A) BUS VOLTAGE (V) POS VOLTAGE (V) NEG VOLTAGE (V)
COMMENTS

TESTED BY WITNESSED BY

………………………………. ………………………………. ………………………………..


Name: Yusmin Jusoh Name: Name:
Designation: Field Engineer Designation: Field Engineer Designation:
Company: Schlumberger Company: Sanden Company: ARAMCO
Date: Date: Date: