You are on page 1of 6

Estimation and Costing

Shopping Mall, Gurgaon

Plan of Shopping mall

1) EARTHWORK IN EXCAVATION

Area of the basements 9500sqm

Height of Excavation (height of 2 floor + 4.2 + 4.2 + 1 = 9.4 m


pcc layer)

Particular of Items No Area Height or Dept Quantity


h
Excavation 1 9500sqm 4.2 + 4.2 = 8.4m 90720 cu m

Lime or lean conc. In foundati 1 9500sqm 1m 10800 cu m


on
According to the table by DAR-
Excavation cost of the Substructure-

Area x Height x rate of amount = Total Excavation cost


9500sqm x 9.4m x 155.6rs = Rs 1,38,95,080

2) PLAIN CEMENT CONCRETE


According to the table by DAR-
PCC cost of the Substructure-

Area x Height x rate of amount = Total PCC bed in substructure cost


Total Area of PCC ( w/o footing) – area of footing x no. of columns = Area of PCC
9500 -1026= 8474sqM
8474 x 0.15m x 5719rs = Rs 72,70,000 ( w/o footing area )

3) FOUNDATIONS, FOOTINGS, BASES OF COLUMNS

Length of one column – 600mm


Length of one footing - 0.6 x 5 = 3m
Area of one footing - 3m x 3m = 9sqm
Height of the footing - 1m
No. of columns - 114
Volume x no. of columns x rate = Total rate
9 x 114 x 196.5 = Rs 2,01,600
4) POURING OF 1:2:4 CEMENT CONCRETE FOR FOUNDATION

Area of one footing - 3m x 3m = 9sqm


Height of the footing - 1m
No. of columns - 114
Volume x no. of columns x rate = Total rate
9 x 114 x 196.5 = Rs 2,01,600
5) Shuttering of Columns

Area of the column – 0.6 x 0.6 = 0.36sqm


Height of the column – 8.4m
No. of columns - 114
Volume x Rate = rate of the shuttering column
3.024 x 453 = RS 1,56,165
6) Retaining Wall

According to the table by DAR-


Retaining wall in Basement cost of the Substructure-

Length of Retaining Wall - 435 M


Ht of Retaining wall - 8.4 M ( Excluding Footing )
Thickness of Wall - 0.3m

Length x Height x Thickness = 1096


Rate X volume = Rs 93,31,344

You might also like