You are on page 1of 2

Simple to Start: Simple to Set: Simple to Defrost: Simple to Check:

Setpoint Temperature Initiate Manual Defrost Pretrip Test

1 2

35
ON ON
°F
35
35 35
ON
°F ON
°F

OFF OFF
PRODUCT/ GAUGES
.8
SENSORS MENU .8 35 2 .8 35
SETPOINT OFF OFF
SET GAUGES SENSORS MENU SET GAUGES SENSORS MENU
2 POINT POINT 3

3 1. Press any key to return to the


1. Press the ON Key. NEW SETPOINT WILL BE
Standard Display.
ON
40 F 1. Return to the Standard Display. 1. Clear all alarm codes.
ON CONFIGURING SYSTEM 2. The THERMO KING Logo appears +/- TO CHANGE OK?
2. Press the SETPOINT Key on DEFROST STARTED MAIN MENU
briefly.
OFF
- + YES NO
the Standard Display.
ON
PRETRIP

OFF
PLEASE WAIT
2. Press the DEFROST Key. 4 ON
LANGUAGE 2. Return to the Standard Display.
3. The startup screen appears while 3 OFF 3
ALARMS
GAUGES
3. Press the + or - Keys to change 3. The display will show OFF
EXIT SELECT UP DOWN
3. Press the MENU Key.
communications are established and the setpoint reading. “Programming Defrost Please 5
the unit prepares for operation. 4. Press the UP or DOWN Key as to
NEW SETPOINT WILL BE
4. Press the YES or NO Key Wait.”
ON
4 choose the Pretrip Menu.
4. The Standard Display defaults to the “TemperatureWatch” screen after 40 F accordingly. 4. The display then shows the
2-1/2 minutes. The TemperatureWatch Display will remain on until any key OFF
+/- TO CHANGE
- + YES
OK?
NO 4 5. Press the SELECT Key to start a
5. The Standard Display appears 4 ON Defrost Display. The bar indicator
is pressed or a check, prevent or shutdown alarm occurs. 35 Pretrip Test.
with setpoint changed to the new will fill in showing the time ON
PRETRIP
OFF PASS
NOTE: For more detailed information, see the Operation chapter in setpoint.
SET
POINT
GAUGES SENSORS MENU
remaining to complete the Defrost 7 6. If the unit is not running, a Full
the appropriate unit operating manual. cycle. When the Defrost cycle is OFF EXIT
Pretrip will be initiated. If the unit is
NEW SETPOINT IS
5 NOTE: For more detailed complete the display returns to running in either diesel or electric
ON

Simple to Set:
40 F information, see the Operation Standard Display screen. mode, a Running Pretrip will be
OFF chapter in the appropriate unit performed.
operating manual. NOTE: For more detailed information, see the Operation chapter in
CYCLE-SENTRY or Continuous Mode the appropriate unit operating manual. 7. When all tests are complete, the results are reported as PASS, CHECK or
FAIL. If the results are CHECK or FAIL, the accompanying alarm codes will

Simple to Access: direct the technician to the cause of the problem.

1 Simple to Check: Sensors


NOTE: For more detailed information, see the Operation chapter in the
appropriate unit operating manual.

35 Gauges
ON
°F
35
OFF
SET
POINT
GAUGES
.8
SENSORS MENU
2&6
1
Simple to Check:
1 Hourmeters
35
ON
°F
35
35
ON
°F .8
35 OFF
SET GAUGES SENSORS MENU
2
POINT
.8 1
3 1. Return to the Standard Display. OFF
SET GAUGES SENSORS MENU
POINT

35
ON
°F
ON PROGRAMMING CONT MODE
2. Press the CYCLE-SENTRY/
.8 35
OFF
PLEASE WAIT Continuous Key. OFF
SET GAUGES SENSORS MENU
POINT

3. The “Programming Continuous 1. Return to the Standard 2


2
Mode” or “Programming CYCLE- CONTROL DISCHARGE AIR TEMPERATURE Display.
SENTRY Mode” screen briefly ON
48. 3
5 1. Return to the Standard Display. °F 2. Press the SENSORS Key.
appears. BATTERY VOLTAGE
OFF
EXIT LOCK BACK NEXT
13.8
ON
v Press the MENUKey. 3. Press the BACK or NEXT
NEW SYSTEM MODE IS 4. The “New System Mode is 1. Return to the Standard Display
ON
OFF
2. Use UP and DOWN soft keys Keys to scroll through the MAIN MENU
Continuous” screen or the “New EXIT LOCK BACK NEXT
SENSORS
CONTINUOUS
to scroll to the gauges option. 3 following sensor screens: ON
DATA LOGGER screen.
OFF
System Mode CYCLE-SENTRY” HOURMETERS

Press the SELECT Key when Control Return Air MODE


screen briefly appears. OFF
EXIT SELECT UP DOWN 2. Press the MENU Key.
3 gauges option is highlighted. Temperature, Display Return Air
5. The Standard Display appears Temperature, Control Discharge Air Temperature, Display Discharge Air 3. Scroll through Main Menu by
and the heading on top of screen 3. Press BACK or NEXT Keys to Temperature, Temperature Differential, Evaporator Coil Temperature,
scroll through following gauges: Coolant Temperature, Coolant Level, repeatedly pressing the UP and
reads the new mode. Ambient Air Temperature, Spare 1 Temperature, Datalogger Temperature 4 DOWN Keys until the hourmeters
Engine Oil Pressure, Engine Oil Level, Amps, Battery Voltage, Accessory Sensors 1-6 and the Board Temperature Sensor. If no keys are pressed
6. Pressing the CYCLE-SENTRY/Continuous Key again will change the Battery Voltage, Engine RPM, Fuel Level Sensor, Discharge Pressure, Main Menu Screen appears.
within 30 seconds, the screen will return to the Standard Display.
unit back to the previous mode. Suction Pressure, ETV Position, Fresh Air Exchange, I/O. If no keys are 4. Press the SELECT Key to enter the Hourmeters Menu.
pressed within 30 seconds, the screen will return to the Standard Display. 4. Press the LOCK Key to display any sensor screen for an indefinite
NOTE: For more detailed information, see the Operation chapter in 5. Press the NEXT and BACK Keys to view the Hourmeter Displays.
4. Press the LOCK Key to display any gauge screen for an indefinite period. Press the key again to unlock the screen.
the appropriate unit operating manual.
period. Press the key again to unlock the screen. 5. Press the EXIT Key to return to the Standard Display. NOTE: For more detailed information, see the Operation chapter in the
5. Press the EXIT Key to return to the Standard Display. appropriate unit operating manual.
NOTE: For more detailed information, see the Operation chapter in
NOTE: For more detailed information, see the Operation chapter in the appropriate unit operating manual.
the appropriate unit operating manual.
85 Forced Unit Operation 522 Battery Temperature Sensor Alarm

Simple to View: Simple to


86 Discharge Pressure Sensor 523 Battery Temperature Sensor Alarm
87 Suction Pressure Sensor 524 Generator Operational Limit V out to

Determine: 89 Check Electronic Throttling Valve Circuit Frequency Ratio


Cause of Alarm 90 Electric Overload 525 Generator Frequency Range Fault
91 Electric Ready Input 526 Generator Operational Limit Output Current
Cause of Alarm 92 Sensor Grades Not Set 527 Reserved

SR-4
93 Low Compressor Suction Pressure 528 Controller Not Receiving Messages From
1
96 Low Fuel Level Battery Charger

35
ON
0 No Alarms Exist 529 Check Fuel Pump Circuit
35 2 Evaporator Coil Sensor
98
99
Fuel Level Sensor
High Compressor Pressure Ratio 530 Low Pressure Differential

Smart Reefer™ 4
OFF
SET
POINT
GAUGES SENSORS MENU 3 Control Return Air Sensor 105 Receiver Tank Pressure Solenoid Circuit 531 Check Economizer Pressure Sensor
2 4 Control Discharge Air Sensor 106 Purge Valve Circuit 538 Engine J1939 CAN Datalink Degraded
5 Ambient Air Sensor 107 Condenser Inlet Solenoid Circuit 539 Engine J1939 CAN Datalink Failed
6 Coolant Temp Sensor 108 Door Open Time-out 599 Engine Service Tool Connected

Microprocessor
7 Engine RPM Sensor 110 Suction Line Solenoid Circuit 600 Check Crankshaft Speed Sensor
9 High Evaporator Temperature 111 Unit Not Configured Correctly 601 Check Camshaft Speed Sensor
1. Return to the Standard Display 10 High Discharge Pressure 602 Check Intake Throttle Position Sensor
MAIN MENU 113 Electric Heat Circuit
ON
PRETRIP Screen. 11 Unit Controlling on Alternate Sensor 114 Multiple Alarms - Cannot Run 603 Check Exhaust Pressure Sensor
LANGUAGE
ALARMS
GAUGES 2. Press the MENU Key. 12 Sensor or Digital Input Shutdown 117 Auto switch from Diesel to Electric 604 Check Coolant Temperature Sensor
OFF
EXIT SELECT UP DOWN
13 Sensor Calibration Check 118 Auto switch from Electric to Diesel 605 Check Fresh Air Temperature Sensor
3. Press the UP or DOWN Key until 17 Engine Failed to Crank 120 Alternator Exciter Circuit 606 Reserved
the Alarm Menu appears. 18 High Engine Coolant Temperature 607 Check Fuel Temperature Sensor
121 Liquid Injection Circuit
4 3 4. Press the SELECT Key. 19 Low Engine Oil Pressure 122 Diesel/Electric Relay Circuit 608 Check Rail Pressure Sensor
The Alarm Display will appear. 20 Engine Failed to Start 127 Setpoint Not Entered 609 Check Intake Pressure Sensor
5
1 OF 2 ALARMS
CHECK AMBIENT TEMP SENSOR
21 Cooling Cycle Check 128 Engine Run Time Maintenance Reminder #1 610 Check Atmospheric Pressure Sensor
ON
5. If alarms are present, the quantity 22 Heating Cycle Check 611 Check Glow Plug Circuit
64 PRETRIP REMINDER
129 Engine Run Time Maintenance Reminder #2
OFF
x 64
of alarms and the most recent alarm 23 Cooling Cycle Fault 130 Electric Run Time Maintenance Reminder #1 612 Check Intake Throttle Circuit
EXIT CLEAR HELP DOWN
code number will be shown. 24 Heating Cycle Fault 613 Check Injector(s)
131 Electric Run Time Maintenance Reminder #2
5 25 Alternator Check 614 Check High Pressure Fuel Pump
6. If necessary to view all alarms, 132 Total Unit Run Time Maintenance Reminder #1
scroll down using the DOWN Key. 26 Refrigeration Capacity 133 Total Unit Run Time Maintenance Reminder #2 615 Rail Pressure Fault
6 28 Pretrip Abort 134 Controller Power On Hours 616 Engine Overspeed
7 7. If a serious condition occurs, the 29 Defrost Damper Circuit 141 Autoswitch Diesel to Electric Disabled 617 Internal ECU Fault
unit will be shut down to prevent 30 Defrost Damper Stuck 143 Remote Zone Drain Hose Heater Output 618 Check EGR System
35 damage to the unit or the load. If
ON

35 this occurs, the Alarm Icon will


31 Oil Pressure Switch 144 Lost Expansion Module CAN Communication 619 ECU Main Relay Fault
OFF SET
POINT
GAUGES SENSORS MENU 32 Refrigeration Capacity Low 145 Loss of Controller "On" Feedback Signal 620 Reserved
appear, the display and backlight 33 Check Engine RPM 146 Software Version Mismatch 621 Reserved
will flash on and off. 35 Run Relay Circuit 622 Reserved
148 Autoswitch Electric to Diesel Disabled
36 Electric Motor Failed to Run 149 Alarm Not Identified 623 TRU CAN Message Timeout
NOTE: For more detailed infor- 37 Engine Coolant Level 150 Out of Range Low 624 Check Intake Air Temperature Sensor
mation, see the Operation chapter in the appropriate unit operating 38 Electric Phase Reversed 151 Out of Range High 625 Check Intake Air Temperature Sensor
manual. 39 Water Valve Circuit 153 Expansion Module Flash Load Failure 626 Check Exhaust Temperature Sensor
40 High Speed Circuit 157 OptiSet Plus Mismatch 699 Unknown ECU Fault

Simple to View:
41 Check Engine Coolant Temperature 158 Primary Software Failed to Load
42 Unit Forced to Low Speed 203 Display Return Air Sensor
43 Unit Forced to Low Speed Modulation 204 Display Discharge Air Sensor
Clearing Alarm Codes 44 Check Fuel System 252 Check Fresh Air Exchange Circuit

Driver Guide to
45 Hot Gas Bypass or Hot Gas Bypass 500 Host Evaporator Fan Low Speed
Circuit 501 Host Evaporator Fan High Speed
1.If the alarm situation has been 46 Check Air Flow 502 Host Evaporator Fan RPM Sensor

Simple
5
1 OF 2 ALARMS
CHECK AMBIENT TEMP SENSOR
resolved press the CLEAR Key to 48 Check Belts/Clutch 503 Host Condenser Fan 1 RPM Sensor
ON
64
x
PRETRIP REMINDER
64
clear the alarm. 50 Reset Clock 504 Host Condenser Fan 2 RPM Sensor
OFF
EXIT CLEAR HELP DOWN 52 Heat Circuit 505 Roadside Condenser Fan Motor Speed Circuit
2. The display will briefly show

Operation
54 Test Mode Time-out 506 Curbside Condenser Fan Motor Speed Circuit
CLEARING ALARMS – PLEASE 56 Host Evap Fan Low Speed 507 Digital Scroll Output Circuit
WAIT. Then the Alarm Menu will 57 Host Evap Fan High Speed 508 Speed Request Communication Error
reappear. 61 Low Battery Voltage 509 Engine Control Unit (ECU) Failed to Enable
1 62 Ammeter Out of Calibration
3. Press the HELP Key for 510 Engine Control Unit (ECU) Run Signal Failed
additional information regarding the 63 Engine Stopped 511 Engine Wait to Start Time Delay Expired
1 OF 1 ALARMS
ON
66 LOW ENGINE OIL LEVEL alarm shown on the display. Also 64 Pretrip Reminder 512 High Compressor Suction Pressure
x 64
see the complete Alarm Code list in 65 Abnormal Temperature Differential 513 Low Compressor Suction Ratio
OFF
EXIT CLEAR HELP DOWN the next column. 66 Low Engine Oil Level 514 Minimum ETV Discharge Superheat
67 Liquid Line Solenoid Circuit Temperature
4. To return to the Main Menu press 68 Internal Controller Fault
the EXIT Key. To return to the 515 Minimum ETV Discharge Superheat
70 Hourmeter Failure Temperature
Standard Display press the EXIT 74 Controller Reset to Defaults
3 Key again. 516 I/O Controller to Application Controller
79 Internal Data Logger Overflow Communication Failure TK 55771-2-PC (Rev. 0, 01/14) ©Thermo King Corporation
NOTE: For more detailed information, see the Operation chapter in the 80 Compressor Temp Sensor 517 Check for Water in Fuel System
appropriate unit operating manual. 81 High Compressor Temp 518 Generator Ground Fault
82 High Compressor Temperature Shutdown 519 Check Battery Charger Input Power
83 Low Engine Coolant Temperature 520 Check Battery Charger Output Power
84 Restart Null 521 Battery Charger External/Environmental Fault