Initial Installation/Startup
Installation Instructions
A31003-H3170-J100-2-7631
Our Quality and Environmental Management Systems are
implemented according to the requirements of the ISO9001 and
ISO14001 standards and are certified by an external certification
company.
unify.com
bkTOC.fm
Nur für den internen Gebrauch Contents
Contents 0
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 3
bkTOC.fm
Contents Nur für den internen Gebrauch
A31003-H3170-J100-2-7631, 05/2015
4 OpenScape 4000 V7, Installation Instructions
bkTOC.fm
Nur für den internen Gebrauch Contents
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 5
bkTOC.fm
Contents Nur für den internen Gebrauch
7.1.1 Connecting to the Mains with LUNA/LPC80 Power Supply Units . . . . . . . . . . . . . . . . . . . . . . . . . . . 141
7.1.2 Connecting to the Mains Using the Power Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 143
7.2 Installing a Three-Phase Network. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 144
7.3 Installing a Single-Phase Network . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 145
7.4 Overview of Mains Connection 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 146
7.5 Installing a Three-Phase or Single-Phase Connection with Mid-Point Grounding, I.M. . . . . . . . . . . . . . . 147
7.6 Overview of Mains Connection 2, I.M. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 148
7.7 Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 149
7.8 AC Connection to Power Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 149
7.8.1 Routing the Power Cables on an AC-Powered, Nonredundant OpenScape 4000 . . . . . . . . . . . . . . 149
7.8.2 Attaching the Power Cable to the CSPCI Box. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 150
7.8.3 Connecting the Mains Cable to the EcoServer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 153
7.9 Setting the Operating Mode for the LPC80, I.M.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 154
7.9.1 Setting the Operating Mode. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 155
7.10 DC Connection with the External Power Supply, I.M.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 156
7.10.1 Routing the Power Cables on an AC-Powered, Redundant OpenScape 4000. . . . . . . . . . . . . . . . 156
7.10.2 Routing the Power Cables from the UACD and UDCD to the OpenScape 4000 . . . . . . . . . . . . . . 158
7.10.3 Attaching a DC Cable to the CSPCI Box. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 158
7.10.4 Connecting the DC Cable to the EcoServer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 161
7.11 DC Connection with UP/L80XF Cabinet, I.M. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 162
7.12 AC-to-DC Connection with a Redundant LTUW Cabinet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 162
7.13 DC Connection with Redundant UPR/LTUW Box, I.M. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 164
7.13.1 Connecting the Battery to the Power Box, I.M. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 165
7.13.2 Connecting the MDF for a Nonredundant, System, I.M. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 166
7.14 AC-to-DC Connection with AP 3700. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 168
7.14.1 AC Connection AP 3700-9/AP 3700-13 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 168
7.14.2 DC Connection AP 3700-9/AP 3700-13 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 168
7.14.3 AC Connection AP 3700 in 19" Cabinet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 169
7.14.4 DC Connection AP 3700 with DCDR (Fuse Unit) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 170
7.14.5 DC Connection AP 3700 with DCDR (DC Kit for 19-Inch Cabinet) . . . . . . . . . . . . . . . . . . . . . . . . . 172
7.14.6 DCDR Connection from Behind. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 173
7.14.7 DC Connection of AP 3700 to the MDF. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 175
7.15 UACD (Lineage Power) 19-Inch Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 176
7.15.1 Connect the power supply to an UACD. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 178
7.15.1.1 Install Primary Shelf A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 179
7.15.1.2 Install Secondary Shelf B - Two shelf System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 182
7.15.1.3 Pulsar Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 186
7.15.1.4 Install DC load output cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 187
7.15.1.5 Thermal Probes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 189
7.15.2 Alarm Outputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 193
7.15.3 UACD Power Box Part Numbers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 193
7.15.4 AC/DC Connection - Cabinet variants . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 195
7.15.4.1 AC/DC Connection UACD with AP3700” . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 195
7.15.4.2 AC/DC Connection UACD with UPR/LTUW” . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 196
7.15.4.3 UACD Cable list . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 197
7.15.5 Mains Connection Variants for UACD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 198
7.15.6 Connecting a Battery to the UACD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 202
7.16 UACD (PSR930/PSR930E) 19-Inch Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 203
7.16.1 UACD Power Box Part Numbers (PSR930/PSR930E) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 206
7.16.2 AC/DC Connection with UACD (PSR930/PSR930E) in 19” Cabinet with AP3700 . . . . . . . . . . . . . 207
7.16.3 AC/DC Connection with UACD (PSR930/PSR930E) in 19” Cabinet with UPR/LTUW . . . . . . . . . . 208
7.16.4 Mains Connection Variants for UACD (PSR930/PSR930E) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 209
A31003-H3170-J100-2-7631, 05/2015
6 OpenScape 4000 V7, Installation Instructions
bkTOC.fm
Nur für den internen Gebrauch Contents
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 7
bkTOC.fm
Contents Nur für den internen Gebrauch
A31003-H3170-J100-2-7631, 05/2015
8 OpenScape 4000 V7, Installation Instructions
bkTOC.fm
Nur für den internen Gebrauch Contents
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 9
bkTOC.fm
Contents Nur für den internen Gebrauch
A31003-H3170-J100-2-7631, 05/2015
10 OpenScape 4000 V7, Installation Instructions
1_safety_FDS70_de.fm
Introduction and Important Notes
Product Overview
• startup
• administration
• maintenance
• troubleshooting
and
• fault recovery
can be performed under normal conditions with the tools integrated in the system
and the existing documentation.
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 11
1_safety_FDS70_de.fm
Introduction and Important Notes
Using this Manual
A31003-H3170-J100-2-7631, 05/2015
12 OpenScape 4000 V7, Installation Instructions
1_safety_FDS70_de.fm
Introduction and Important Notes
Safety Information and Warnings
For the purposes of safety information and warnings, qualified persons are
persons who are authorized to place into operation, ground, and label systems,
devices, and lines in accordance with applicable safety procedures and
standards.
It is absolutely essential that you read and understand the following safety infor-
mation and warnings before starting installation and implementation work on the
communication system or device.
You should also carefully read and observe all safety information and warnings
on the communication systems and devices themselves.
Always consult your manager before starting work in conditions where the
necessary safety precautions do not appear to be in place.
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 13
1_safety_FDS70_de.fm
Introduction and Important Notes
Safety Information and Warnings
7 DANGER
Indicates an immediate danger that could result in death or serious injury.
7 WARNING
Indicates a general danger that could result in death or serious injury.
7 CAUTION
Indicates a danger that could result in injury.
NOTE: Indicates situations that could result in damage to property and/or loss of
data.
1 5 3 0 6 4 2
Electricity Weight Heat Fire Chemicals ESD* Laser
A31003-H3170-J100-2-7631, 05/2015
14 OpenScape 4000 V7, Installation Instructions
1_safety_FDS70_de.fm
Introduction and Important Notes
Safety Information and Warnings
7 DANGER
Risk of electric shock through contact with live wires
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 15
1_safety_FDS70_de.fm
Introduction and Important Notes
Safety Information and Warnings
7 WARNING
Risk of electric shock through contact with live wires
There are additional dangers even when working with low voltage and large cable
cross-sections. Cables with a large cross-section generally have lower voltages,
although the amperages are higher.
• Before starting any work, check that the circuits involved are de-energized.
Never take it for granted that turning off a main switch or circuit breaker will
reliably interrupt all circuits.
• Only use systems, tools, and equipment which are in perfect condition. Do not
use equipment with visible damage.
• Replace any damaged safety equipment (covers, labels and ground wires)
immediately.
A31003-H3170-J100-2-7631, 05/2015
16 OpenScape 4000 V7, Installation Instructions
1_safety_FDS70_de.fm
Introduction and Important Notes
Safety Information and Warnings
7 WARNING
Disconnection from power circuit(s)
• Before carrying out any work on the communication system or on the device,
find out whether there is a disconnect device and locate it.
• When you need to disconnect the power supply to the communication system
or device, you do so using the disconnect device.
• If you are performing work on circuits with hazardous voltages, always work
together with a partner who is familiar with the location of the disconnect
devices for the power supplies.
• Always disconnect the power supply when you are working directly next to a
power supply unit or direct current converter, unless the work instructions
expressly permit you to work without disconnecting the power supply.
• As long as the power supply is switched on, always observe the greatest
caution when performing measurements on powered components and
maintenance work on plug-in cards, PC boards and covers.
• Metallic surfaces such as mirrors are conductive. If you touch them, there is
a risk of electric shocks or short circuits.
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 17
1_safety_FDS70_de.fm
Introduction and Important Notes
Safety Information and Warnings
7 CAUTION
Danger of injury:
7 CAUTION
Risk of explosion if accumulators and batteries are not changed properly:
7 CAUTION
Risk of fire:
• The system cabinets must not be fitted with any third-party devices that have
not been approved.
A31003-H3170-J100-2-7631, 05/2015
18 OpenScape 4000 V7, Installation Instructions
1_safety_FDS70_de.fm
Introduction and Important Notes
Safety Information and Warnings
7 CAUTION
General risk of injury/accidents in the workplace:
• When maintenance work has been completed, always re-install all safety
equipment in the right place. Also close all doors, covers, or the housing after
completing test and maintenance work.
• Make sure that the work area is well lit and tidy.
• When working on the communication system, never wear loose clothing and
always tie back long hair.
• Always wear a hard hat where there is a risk of injury from falling objects.
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 19
1_safety_FDS70_de.fm
Introduction and Important Notes
Safety Information and Warnings
• Before placing the system into operation, check whether the nominal voltage
of the power supply network corresponds to the nominal voltage of the
communication system or device (type plate). If necessary, adjust the nominal
voltage of the communication system or device appropriately.
• Use only original accessories. Failure to comply with this safety information
may damage the communication system or violate safety and EMC regula-
tions.
• Before starting wall assembly, check that the load-bearing capacity of the wall
is adequate, Always use suitable installation and fixing material to make sure
that the communication system is mounted safely.
• Condensation damage:
If the temperature changes rapidly, air humidity can precipitate. If the commu-
nication system or device is moved from a colder to a warmer environment,
moisture can precipitate. Wait until the temperature has adjusted to the
ambient temperature and the communication system or device is completely
dry before starting it up.
A31003-H3170-J100-2-7631, 05/2015
20 OpenScape 4000 V7, Installation Instructions
1_safety_FDS70_de.fm
Introduction and Important Notes
Emergencies
1.5 Emergencies
What to do in an emergency
• In the event of an accident, remain calm and controlled.
• Always switch off the power supply before you touch an accident victim.
• If you are not able to immediately switch off the power supply, only touch the
victim with non-conductive materials (such as a wooden broom handle), and
first of all try to isolate the victim from the power supply.
First aid
• Be familiar with basic first aid procedures for electrical shock. A fundamental
knowledge of the various resuscitation methods if the victim has stopped
breathing or if the victim’s heart is no longer beating, as well as first aid for
treating burns, is absolutely necessary in such emergencies.
– What happened?
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 21
1_safety_FDS70_de.fm
Introduction and Important Notes
Normal Use
A31003-H3170-J100-2-7631, 05/2015
22 OpenScape 4000 V7, Installation Instructions
1_safety_FDS70_de.fm
Introduction and Important Notes
Proper Disposal and Recycling
The correct disposal and separate collection of your old appliance will
help prevent potential negative consequences for the environment
and human health. It is a precondition for reuse and recycling of used
electrical and electronic equipment.
The statements quoted above are only fully valid for equipment which
is installed and sold in the countries of the European Union and is
covered by the directive 2002/96/EC. Countries outside the
European Union may have other regulations regarding the disposal
of electrical and electronic equipment.
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 23
1_safety_FDS70_de.fm
Introduction and Important Notes
Standards and Guidelines on Installation
To conform with the legal fire protection and EMC requirements, operate the
OpenScape systems only when closed. You may open the system only briefly for
assembly and maintenance work.
A31003-H3170-J100-2-7631, 05/2015
24 OpenScape 4000 V7, Installation Instructions
1_safety_FDS70_de.fm
Introduction and Important Notes
Standards and Guidelines on Installation
• For the LAN connection to boards in LTUs, the notes regarding the shielding
connection at the opening of the LTU frame must be observed accordingly.
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 25
1_safety_FDS70_de.fm
Introduction and Important Notes
Standards and Guidelines on Installation
1.9.4 Labeling
A31003-H3170-J100-2-7631, 05/2015
26 OpenScape 4000 V7, Installation Instructions
1_safety_FDS70_de.fm
Introduction and Important Notes
Data Protection and Data Security
In Germany, the processing and use of such data is subject to various regulations,
including those of the Federal Data Protection Law (Bundesdatenschutzgesetz,
BDSG). Observe all applicable laws in other countries.
By protecting data against misuse during all stages of processing, privacy legis-
lation also protects the material interests of the individual and of third parties.
Employees of Unify Software and Solutions GmbH & Co. KG are bound to safeguard trad
personal data under the terms of the company’s work rules.
It is imperative to observe the following rules to ensure that the statutory provi-
sions relating to service (on-site or remote) are strictly followed. This safeguards
the interests of the customer and offers added personal protection.
• Use the password features of the system with no exceptions. Never give
passwords to an unauthorized person orally or in writing.
• Ensure that storage media which are no longer required are completely
destroyed. Ensure that no sensitive documents are left unprotected.
Work closely with your customer contact; this promotes trust and reduces
your workload.
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 27
1_safety_FDS70_de.fm
Introduction and Important Notes
Documentation Feedback
When you call, state the title, ID number, and issue of the document.
Example:
• Title: OpenScape 4000 V7 IP Solution, Service Documentation
• ID number: P31003H3170S101010020
• Issue: 1
A31003-H3170-J100-2-7631, 05/2015
28 OpenScape 4000 V7, Installation Instructions
2_Uebersicht.fm
Overview
System Configuration
2 Overview
This chapter provides an overview of the major system functions and components
of OpenScape 4000.
This manual describes the installation of the OpenScape 4000. OpenScape 4000
IP provides custom convergence applications and multimedia communications
solutions from workstation to workstation.
• 1 central control box CSPCI (Data and Switch Processor for Compact-PCI/
LAN) or an EcoServer. The CSPCI box or EcoServer can be installed as a
standalone unit or separately mounted in a 19" / 30" rack.
The AC-powered redundant OpenScape 4000 has a maximum of two power box
(UACD) cabinets. The DC-powered redundant OpenScape 4000 has a maximum
of two, 2-stack power box cabinets.
• AC-powered, nonredundant
• AC-powered, redundant
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 29
2_Uebersicht.fm
Overview
System Configuration
The CSPCI box (Data and Switch Processor for Compact-PCI/LAN) or EcoServer
is located either in stack 1 of the nonredundant AC-powered OpenScape 4000,
set up individually, or mounted in a separate 19" rack. The remaining three
shelves are telephony shelves called line trunk unit wide (LTUW) shelves.
LPC80
LPC80
LPC80
PSUP
PSUP
PSUP
PSUP
L80XF L80XF L80XF L80XF
LPC80
LPC80
LPC80
LPC80
L80XF L80XF L80XF L80XF
PSUP
PSUP
PSUP
PSUP
LPC80
LPC80
LPC80
LPC80
L80XF L80XF L80XF L80XF
PSUP
PSUP
PSUP
PSUP
LPSUC
LPSUC
LPSUC
CSPCI/
PSUP
PSUP
PSUP
L80XF L80XF L80XF
EcoServer
A31003-H3170-J100-2-7631, 05/2015
30 OpenScape 4000 V7, Installation Instructions
2_Uebersicht.fm
Overview
System Configuration
The CSPCI box provides switching unit (SWU) and administration and data
processor (ADP) functions.
• A common control unit that starts and controls the call processing functions
and features of the system
• A switching network that controls the voice data highways that carry infor-
mation through the system
• A service unit that provides ringing, tones, conference call switching, dual-
tone multi frequency (DTMF) button signals, and public network dial tones for
LTU boards
• Duplex
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 31
2_Uebersicht.fm
Overview
System Configuration
2.1.1.2 Duplex
This configuration has two common controls (CC) including ADP. Each common
control is powered by a separate power supply.
Slot Modules
5/6 DSCXL2+ (CC-B) •
2x DSCXL2+: S30122-X8004-X39
HDTR2: S30122-X8007-X4
PSU:ACPCI / DCPCI
Fan:C39165-A7070-B14
RTM: S30810-Q2312-X (back)
MCM: S30810-Q2313-X (back)
2.1.1.3 Mono
Slot Modules
5/6 Panel •
3/4 Panel •
Fan HDTR2 Fan
1/2 • DSCXL2+ • •
DSCXL2+: S30122-X8004-X39
HDTR2: S30122-X8007-X4
PSU:ACPCI / DCPCI
A31003-H3170-J100-2-7631, 05/2015
32 OpenScape 4000 V7, Installation Instructions
2_Uebersicht.fm
Overview
System Configuration
Fan:C39165-A7070-B14
RTM: S30810-Q2312-X (back)
MCM: S30810-Q2313-X (back)
2.1.1.4 EcoServer
Figure 2 EcoServer
This new system combines a main processor module with the functionalities of
the RTM and the connectivity functions of the MCM. Two of the new 19" systems
can be interconnected using a special cross-connect cable to create a redundant
system.
The OpenScape 4000 EcoServer Shelf is the base cabinet of the OpenScape
4000 system. The main processor module is based on an x86 architecture as the
successor to the former DSCXL2.
Two redundant hot-plug power supplies fulfill the requirements for dual AC or DC
device connections and high availability. All fixed cable port connections are
located on the rear wall of the box.
Two redundant high-availability fans are installed inside the EcoServer. These
fans are optimally reliable and may not be replaced.
For more details on the EcoServer, see the hardware section of the "OpenScape
4000" Service Manual.
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 33
2_Uebersicht.fm
Overview
System Configuration
The line trunk unit wide (LTUW) shelf is the new version of the LTUE shelf. It
functions as an interface between the system and the external environment using
champ connectors (see Figure 3). The LTUW shelf is only available with
redundant OpenScape 4000 AC and DC systems.
• An LTUCA board
SIVAPAC (MDF)
SIVAPAC (MDF)
SIVAPAC (MDF)
SIVAPAC (MDF)
SIVAPAC (MDF)
SIVAPAC (MDF)
SIVAPAC (MDF)
SIVAPAC (MDF)
SIVAPAC (MDF)
SIVAPAC (MDF)
SIVAPAC (MDF)
Champ (MDF)
Champ (MDF)
Champ (MDF)
Champ (MDF)
Champ (MDF)
Champ (MDF)
Champ (MDF)
Champ (MDF)
Champ (MDF)
Champ (MDF)
Champ (MDF)
Champ (MDF)
PSUP
PSUP
HTS
Bulk
Talk
PFI
RG/WG
RG/WG
LTUC.. board
PSUP
PSUP
BG 10
BG 15
BG 16
BG 1
BG 2
BG 3
BG 4
BG 5
BG 6
BG 7
BG 8
BG 9
WGM
RGM
Bulk
40000040ger
A31003-H3170-J100-2-7631, 05/2015
34 OpenScape 4000 V7, Installation Instructions
2_Uebersicht.fm
Overview
System Configuration
The OpenScape 4000 system uses SIPAC LTUW shelves. SIPAC and SIVAPAC
shelves cannot be mixed in the same system.
UACD
LTUW LTUW LTUW LTUW
UACD 2
LTUW LTUW LTUW LTUW
UACD 1 CSPCI/
LTUW LTUW LTUW
EcoServer
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 35
2_Uebersicht.fm
Overview
System Configuration
see Figure 5. Each DC-powered OpenScape 4000 cabinet stack receives input
power from one UDCD. The UDCD receives input power from a DC power
system.
The OpenScape 4000 system uses SIPAC LTUW shelves. SIPAC and SIVAPAC
shelves cannot be mixed in the same system.
PSU PSU
PSU PSU
PSU PSU
PSU PSU
PSU PSU PSU
PSU
PSU PSU
PSU PSU
PSU PSU
LTUW LTUW LTUW LTUW
PSU
PSU
LTUW LTUW LTUW
EcoServer
Figure 5 OpenScape 4000, DC-powered, cabinet layout
A31003-H3170-J100-2-7631, 05/2015
36 OpenScape 4000 V7, Installation Instructions
2_Uebersicht.fm
Overview
System Configuration
UP/UPR
1(L80XF/LTUW)
AP 3700-13(13 slots) only
UCS CSPCI/ in 19" cabinet
EcoServer
RTM
AP 3700-13L *-G5413-X
T
U
C
A
LUN LUN LUN LUN
A2 A2 A2 A2
However, Survivability Server can control all types of IPDA access points
(AP 3300 IP, AP 3500 IP, AP 3700 IP) in emergency situations, regardless of
whether the access points are equipped with NCUI(1) or NCUI2.
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 37
2_Uebersicht.fm
Overview
System Configuration
Depending on the power supply module used, it can be operated with an 110/
230Vac or 48 Vdc supply.
In AP 3700 IP, there is no electrical connection between the access point and the
server.
The Survivability Server and NCUI of the same access point communicate with
each other exclusively via the IP network (see also the service manual for
"OpenScape 4000 V7 IP Solutions, IPDA&APE").
DSCXL2+ module
Panel
A31003-H3170-J100-2-7631, 05/2015
38 OpenScape 4000 V7, Installation Instructions
2_Uebersicht.fm
Overview
Switching Units
• DSCXL board (data processor controller 586) with LAN and 256 MB of
dynamic memory
• Clock generator function included on the RTM board (memory time switch
with clock generator MTSCG)
The memory time switch section of the RTM board performs the switching
network function in a OpenScape 4000 system. The SWU DSXCL board and
common control boards control the RTM board over the multibus.
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 39
2_Uebersicht.fm
Overview
Switching Units
The service unit functions in a OpenScape 4000 are distributed among the
following:
• Ring generator
A31003-H3170-J100-2-7631, 05/2015
40 OpenScape 4000 V7, Installation Instructions
2_Uebersicht.fm
Overview
Telephony Shelves
NOTE: Certain devices and applications can be, or must be, directly inter-
faced to the internal or external server. This is accomplished using the
DSCXL2+ or LAN connection board. Refer to the OpenScape 4000 Service
Manual for additional information about these boards.
Server Types
Applications Administrative External
Data Processor Server
(ADP)
Administrative data processor X
Xpressions X
CallBridge X
OpenScape 4000 Manager X
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 41
2_Uebersicht.fm
Overview
External Servers
Server Types
OS CC X
OS Xpert X
• System startup
The ADP is responsible for commissioning (placing into service) the system.
The ADP also reloads flashware and loadware on a subsystem level (ADP, SWU,
and ACD secondary server) and an individual module level (after deactivation
and activation of boards).
A31003-H3170-J100-2-7631, 05/2015
42 OpenScape 4000 V7, Installation Instructions
2_Uebersicht.fm
Overview
External Servers
• Startup of ADP:
The OpenScape 4000 Manager provides direct command line access for admin-
istration and troubleshooting configuration and system problems.
The Linux-based RMA application provides information and status reports for
major and minor alarms.
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 43
2_Uebersicht.fm
Overview
External Servers
CDR provides traffic statistics for monitoring system activity and evaluating
system performance. CDR statistics can also be used by the traffic metering and
statistics application.
Application software in the ADP provides for system security. The system admin-
istrator uses the software to assign user passwords and control the access level
of those passwords. This prevents unauthorized access to the system and to
critical system files, databases, and administration or maintenance facilities.
2.4.1.8 RDS
2.4.1.9 HSD
A31003-H3170-J100-2-7631, 05/2015
44 OpenScape 4000 V7, Installation Instructions
2_Uebersicht.fm
Overview
Internal Servers
• DSCXL2+ board
• SF2x8 board
Each of the common control unit boards interface with one another over the
multibus/PCI bus.
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 45
2_Uebersicht.fm
Overview
Internal Servers
A31003-H3170-J100-2-7631, 05/2015
46 OpenScape 4000 V7, Installation Instructions
3_Montagevorbereitungen.fm
Preparing for Installation
Installation Procedures Matrix
e) Remove the system from its Section 3.6, “Removing the System
packaging. from its Packaging”
f) Remove the system from the Section 3.7, “Unloading a System with
pallet. a Roller Base from the Pallet”
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 47
3_Montagevorbereitungen.fm
Preparing for Installation
Installation Procedures Matrix
A31003-H3170-J100-2-7631, 05/2015
48 OpenScape 4000 V7, Installation Instructions
3_Montagevorbereitungen.fm
Preparing for Installation
Installation Procedures Matrix
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 49
3_Montagevorbereitungen.fm
Preparing for Installation
Installation Materials
Tools Size
Allen key wrenches Complete set
Cable stripper
Channel lock pliers, large
Communication technician’s pliers
Compass saw
Cross-head screwdriver (Phillips screwdriver in the
U.S.)
Diagonal cutting pliers
Drill
Gloves
Hammer 400 g
Insertion tool (board removal and replacement tool in the
U.S.)
Level
Meter stick (yardstick in the U.S.)
Module key (board removal and replacement tool in the
U.S.)
Ring or flat spanners (open-ended socket wrench in the 8 mm to 19 mm (.3 to .7 in)
U.S.)
Socket spanner set (socket wrench in the U.S.) 10 mm to 19 mm (.4 in to .7 in)
Screwdrivers 2 mm to 8 mm
In the U.S.: Phillips (no. 2 and
no. 3) and flat-blade (3/16 inch
by 4 inch)
Seismic anchor kit (if applicable)
Side cutter
Soldering iron
Spirit level (level in the U.S.)
Stripping knife
Telephone pliers (long-nose pliers)
A31003-H3170-J100-2-7631, 05/2015
50 OpenScape 4000 V7, Installation Instructions
3_Montagevorbereitungen.fm
Preparing for Installation
Conducting the Site Verification
Tools Size
Terminal crimping pliers (crimpers in the U.S.) Up to 50 mm (2 in)
Torx screwdrivers Complete set
Wrench, hex key, 6 mm
Wrench, hex socket, 7/32 inch
Wrist band and conductive pad (ESD equipment in the
U.S.)
• Scissors
• Site map
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 51
3_Montagevorbereitungen.fm
Preparing for Installation
Inspecting for Shipping Damage
1. List any obvious external damage on the shipping documents, then ask the
delivery personnel to sign the documents.
7 CAUTION
Risk of injury when unpacking the system
Never try to lift heavy objects without assistance.
4. Record and report any damages according to local procedures or the appro-
priate service center.
7 WARNING
Electric shock caused by damaged material
Replace the power cable immediately if it shows any signs of damage. Replace
any damaged safety equipment (covers, labels and ground wires) immediately.
IMPORTANT: Place the pallet as close to the equipment room as possible before
removing the cabinet.
A31003-H3170-J100-2-7631, 05/2015
52 OpenScape 4000 V7, Installation Instructions
3_Montagevorbereitungen.fm
Preparing for Installation
Positioning the Cabinets
To remove a system with a roller base from the pallet (see Figure 1):
1. At the base of the cabinet, remove the screws on the left and right sides of
the pallet.
2. Tilt the system slightly to one side (1) and slide out the crosspiece (2). Repeat
this procedure on the other side.
3. Push the two boards to the middle (3) and slide them out (4).
NOTE: Secure all four casters (only for a 3 or 4-cabinet system) to prevent the
system from rolling away. Lock the rollers once the system is installed or moved.
5
4 3
1. Unlock the casters by lifting the caster locks upwards on the cabinet leveling
assembly (see Figure 2).
2. Roll the cabinet into the location specified by the equipment room floor plan.
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 53
3_Montagevorbereitungen.fm
Preparing for Installation
Leveling the Cabinets
3. Lock the casters by pushing the lock on the cabinet leveling assembly
downwards.
To unlock
To lock
2. Use the Allen wrench to adjust the height of the caster (2).
1 2
A31003-H3170-J100-2-7631, 05/2015
54 OpenScape 4000 V7, Installation Instructions
3_Montagevorbereitungen.fm
Preparing for Installation
Leveling the Cabinets
IMPORTANT: This procedure applies only for the AP3700-9. The AP3700-13
cabinet should only be installed in a 19" shelf and is not intended for standalone
installation.
2. Adjust the height of the foot by turning the wrench (2) left or right.
1
2
Figure 4 Leveling the feet
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 55
3_Montagevorbereitungen.fm
Preparing for Installation
Removing the Front Covers
1. Find the two slots under the front cover (see arrows under the front cover on
Figure 5).).
2. Insert a 5/8-in. (or smaller) flat-blade screwdriver into each of the two slots
and push hard (until you hear a click) to release the cover.
Slot Slot
3. Pull the bottom part of the front cover away from the cabinet and lift upwards
(see Figure 6).
A31003-H3170-J100-2-7631, 05/2015
56 OpenScape 4000 V7, Installation Instructions
3_Montagevorbereitungen.fm
Preparing for Installation
Removing the Front Covers
The back covers can be removed in the same way, by pulling them toward the
back.
1. At the top of the cabinet, remove the screw on the top cover with a flat-blade
screwdriver (see Figure 8 and Figure 9).
2. Using two hands, lift the cover upwards to disengage it from the cabinet frame
mounting bracket.
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 57
3_Montagevorbereitungen.fm
Preparing for Installation
Removing the Front Covers
Screw
Cover latches
Cabinet frame
mounting
bracket
2 3
1
A31003-H3170-J100-2-7631, 05/2015
58 OpenScape 4000 V7, Installation Instructions
3_Montagevorbereitungen.fm
Preparing for Installation
Removing the Front Covers
3. If the system contains multiple cabinets, remove the remaining covers from
the lower cabinets by following step 2 (see Figure 10).
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 59
3_Montagevorbereitungen.fm
Preparing for Installation
Important Labels on the System
A31003-H3170-J100-2-7631, 05/2015
60 OpenScape 4000 V7, Installation Instructions
3_Montagevorbereitungen.fm
Preparing for Installation
Important Labels on the System
WARNING
HIGH LEAKAGE CURRENT
Earth Connection Required
Before Connecting Supply
! AVERTISSEMENT
COURANT DE FUITE ELEVE
Raccordement a la terre
indispensable avant
le raccordement au reseau
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 61
3_Montagevorbereitungen.fm
Preparing for Installation
Important Labels on the System
MSOP
V32905-B23-
Compliance
X201 with
V32905-B22-X108
second cabinet
40000120ger2
Figure 14 Locations of the labels on the system
A31003-H3170-J100-2-7631, 05/2015
62 OpenScape 4000 V7, Installation Instructions
3_Montagevorbereitungen.fm
Preparing for Installation
Inventorying the System Hardware
1. Compare the hardware in the cabinet against the packing slip, bill of
materials, and hardware map.
To inventory the installation kit, refer to the packing list that accompanies the
system.
• Maintenance limits
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 63
3_Montagevorbereitungen.fm
Preparing for Installation
Installing Seismic Anchors
2. Confirm with the facility provider coordinator that all trunk testing has been
scheduled with the telephone company or vendor.
1. Ensure that the earthquake kits are supported on a floor located at or below
grade level of the building.
2. Ensure that a qualified engineer reviews the anchorage and adequacy of the
floor for the following conditions:
• The floor slab is at least 4 inches thick and capable of supporting loads
imposed by the equipment.
4. Perform a load test of 50% of the anchors in accordance with the California
Department of General Services, division of State Architect, Interpretation of
Regulations Document 19-1, September 1, 1999 (reference, Expansion Bolts
or Epoxy Type Anchors in Concrete).
A31003-H3170-J100-2-7631, 05/2015
64 OpenScape 4000 V7, Installation Instructions
3_Montagevorbereitungen.fm
Preparing for Installation
Stacking OpenScape 4000 Cabinets
NOTE: Use extreme care and caution when you install drilled-in anchors in
existing non-prestressed reinforced concrete to avoid cutting or damaging the
existing reinforcing bars and tension wires during installation.
7. The M8 high-strength bolts that connect the bracket to the cabinet frame are
Grade 5. Tighten the bolts to 35-40 ft-lbs. to ensure that they do not slip in the
slotted holes.
To add cabinets to the system, refer to Section , “Adding Cabinets to the System”.
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 65
3_Montagevorbereitungen.fm
Preparing for Installation
Installing the Cable Channels
1. At the back of the base cabinet, place the cable channel against the cabinet
as shown in Figure 16.
Screw
Screw location
location
Cable
channels
Screw
location
Figure 16 Cable channels
A31003-H3170-J100-2-7631, 05/2015
66 OpenScape 4000 V7, Installation Instructions
4_Montagehinweise.fm
Special Installation Notes
Removing 24-Port Boards
- Always put on the ESD wrist strap on your bare wrist before you touch any of
the boards or assemblies.
Always place and work with the boards on a grounded conductive pad.
7 WARNING
Risk of electric shock while working on the power system
To avoid electrical shock, never wear the ESD wrist strap while working on the
power system or at the back of the cabinet. Danger of electric shock!
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 67
4_Montagehinweise.fm
Special Installation Notes
Removing 24-Port Boards
1. Only use the supplied board removal and replacement tool (see Figure 1).
2. Refer to the markings on the board removal and replacement tool for instruc-
tions on how to use it.
The installed Adapter 1 makes the 16-port boards protrude from the shelf, a little
farther than the 24-port boards. To lock the 16-port boards into position, special
latches are provided above (black) and below (gray) the shelf. When the adapters
are installed, only the gray latches lock into place.
IMPORTANT: The Adapter 1 has three pieces: one power-up module and two
adapter modules (see Figure 3).
You must install the 16-port adapters manually, as they cannot be installed using
the board removal and replacement tool. You cannot use this tool to seat boards
with gray latches into place. To remove the boards, follow the instructions in
Section 4.1, “Removing 24-Port Boards”.
A31003-H3170-J100-2-7631, 05/2015
68 OpenScape 4000 V7, Installation Instructions
4_Montagehinweise.fm
Special Installation Notes
Removing 24-Port Boards
4. On the adapter module (labeled 1 and 2), slightly pull the catch hooks apart.
5. Position the adapter module over the backplane connector of the board.
6. Ensure that the outer edge of each adapter module corresponds with each
outer edge of the board.
7. Ensure that each adapter module’s outermost row of pins is aligned with the
outermost row of the board connector, then insert the module into the
connector.
IMPORTANT: If the clearance between the board connector and the hot plug
connector on the board is not sufficient for the module catch hook, loosen the
two hot plug connector screws on the back of the board and adjust location
to allow the catch hook to fit between the hot plug and the board connector.
10. Insert the power-up module (3) into the hot plug connector of the board.
1 3 2
Figure 2 Installing SIVAPAC-to-SIPAC adapter 1 (1 of 2)
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 69
4_Montagehinweise.fm
Special Installation Notes
Removing 24-Port Boards
Adapter modules
711
RK/9 6
5-B
8-A19
C3922
Power-up module
ter 1
Adap s
en
Siem
ter 1
Adap s
en
Siem
Catch hook
Component
side
LEDs
40000038ger
Figure 3 Installing SIVAPAC-to-SIPAC adapter 1 (2 of 2)
2. Insert the power-up module into the middle section of the backplane
connector as shown in Figure 4.
4. Position the adapter module over the backplane connector of the board.
Ensure that the outer edge of each adapter module corresponds with each
outer edge of the board as shown in Figure 4.
A31003-H3170-J100-2-7631, 05/2015
70 OpenScape 4000 V7, Installation Instructions
4_Montagehinweise.fm
Special Installation Notes
Removing 24-Port Boards
5. Ensure that each adapter module’s outermost row of pins is aligned with the
outermost row of the board connector, then insert the module into the
connector.
7. If the catch hooks do not correctly lock, the adapter module is incorrectly
positioned. Reverse the position of the module and repeat the step.
Adapter modules
512
RK/9 8
195-B
C392
28-A
Power-up module
ter 2
Adap s
To SIVAPAC
backplane
en
Siem
512
RK/9 8
195-B
28-A
C392
ter 2
Adap s
en
Siem
Catch hook
Catch hook
Component
side
LEDs
40000039ger
Figure 4 Installing SIPAC-to-SIVAPAC board adapter 2
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 71
4_Montagehinweise.fm
Special Installation Notes
Installing Shielding Covers
• On the front and the rear in the case of blank board slots
1. Insert the two bottom pins on the shielding cover into the openings provided
for this purpose on the slide-in shelf.
2. Now push the shielding cover in the direction of the board until it locks into
position (refer to Bild 5).
A31003-H3170-J100-2-7631, 05/2015
72 OpenScape 4000 V7, Installation Instructions
4_Montagehinweise.fm
Special Installation Notes
Installing 24DA Splitting Strips on an Old Main Distribution Frame
1. Fasten a screw on the applicable adapter strap to the left-hand side of the
splitting strip, as shown in Figure 6.
2. Fasten a screw on the second adapter strap to the right-hand side of the
splitting strip, as shown in Figure 7.
3. Fasten a screw on the left-hand side of the pre-assembled splitting strip to the
MDF as shown in Figure 8 (1).
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 73
4_Montagehinweise.fm
Special Installation Notes
Installing 24DA Splitting Strips on an Old Main Distribution Frame
1
2
A31003-H3170-J100-2-7631, 05/2015
74 OpenScape 4000 V7, Installation Instructions
4_Montagehinweise.fm
Special Installation Notes
Installing AP 3700 Cabinets in 19-Inch Cabinets
Figure 9 Bearing elbow and support bracket for AP 3700 in the 19-inch
cabinet
Sequence of installation:
2. Secure both support brackets (A, in Figure 9) to the sides of the system box
with four of the screws supplied.
3. Secure a right and left bearing elbow (B, in Figure 9) in the 19-inch cabinet
with the screws provided.
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 75
4_Montagehinweise.fm
Special Installation Notes
Replacing the CSPCI/CCDAX in the 30" Shelf with an EcoServer
4. Lift the system cabinet into the 19-inch cabinet and sit the cabinet on the two
bearing elbows (B, inFigure 9). Push the cabinet into the 19-inch cabinet until
the front edge of the cabinet is flush with the front of the 19-inch frame.
7 CAUTION
Risk of injury when lifting heavy objects/loads
Always seek assistance before lifting a system cabinet into the 19-inch cabinet -
never do it on your own.
5. Secure the system cabinet to the frame of the 19-inch cabinet by means of
the two support brackets (A, in Figure 9) and the screws provided. Make sure
the minimum play specified for the system cabinets is provided (see Section
5.8.3, “AP 3700 Configuration Rules and Examples with 19" Cabinets/Open
Racks”).
2. Turn off the power supply/power supplies for the system and/or remove the
mains plug from the CSPCI/CCDAX power supply.
A31003-H3170-J100-2-7631, 05/2015
76 OpenScape 4000 V7, Installation Instructions
4_Montagehinweise.fm
Special Installation Notes
Replacing the CSPCI/CCDAX in the 30" Shelf with an EcoServer
4. Remove all cables at the front and rear of the CSPCI/CCDAX server (LTU,
application, clock, V.24, ASW, ALIN cable, etc.).
5. Loosen the fixing screws at the rear of the CSPCI/CCDAX shelf and twist to
remove.
6. Once you have removed the fixing screws on the CSPCI/CCDAX shelf, push
the entire CSPCI/CCDAX shelf including mounting plates out frontwards.
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 77
4_Montagehinweise.fm
Special Installation Notes
Replacing the CSPCI/CCDAX in the 30" Shelf with an EcoServer
Back
Front
7. Set aside all hanging cables so that the adapter frame for the EcoServer can
be installed without obstructions.
2. Turn off the power supply/power supplies for the system and/or remove the
mains plug from the CCDAX power supply.
4. Remove all cables at the front and rear of the CCDAX server (LTU, appli-
cation, clock, V.24, ASW, ALIN cable, etc.).
5. Loosen the fixing screws at the rear of the CCDAX shelf and twist to remove.
A31003-H3170-J100-2-7631, 05/2015
78 OpenScape 4000 V7, Installation Instructions
4_Montagehinweise.fm
Special Installation Notes
Replacing the CSPCI/CCDAX in the 30" Shelf with an EcoServer
6. Once you have removed the fixing screws on the CCDAX shelf, push the
entire CCDAX shelf including mounting plates out frontwards.
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 79
4_Montagehinweise.fm
Special Installation Notes
Replacing the CSPCI/CCDAX in the 30" Shelf with an EcoServer
Back
Front
7. Set aside all hanging cables so that the adapter frame for the EcoServer can
be installed without obstructions.
A31003-H3170-J100-2-7631, 05/2015
80 OpenScape 4000 V7, Installation Instructions
4_Montagehinweise.fm
Special Installation Notes
Replacing the CSPCI/CCDAX in the 30" Shelf with an EcoServer
This installation step describes the pre-assembly of the front retaining plate if only
one EcoServer is installed (not duplex).
1. First take the front retaining plate with the associated retaining nuts and
position these as shown in the next diagram in the designated fixing holes.
NOTE: If two EcoServers are being installed (in duplex mode), you have to install
a further two retaining nuts to the top right on the front retaining plate (yellow
marking).
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 81
4_Montagehinweise.fm
Special Installation Notes
Replacing the CSPCI/CCDAX in the 30" Shelf with an EcoServer
2. Take the two adapter frames and secure the rear retaining plates including
retaining nuts using 5 screws each (yellow marking) to the respective adapter
frame.
NOTE: If two EcoServers are being installed (in duplex mode), you have to omit
the two retaining nuts to the top right (see blue marking).
A31003-H3170-J100-2-7631, 05/2015
82 OpenScape 4000 V7, Installation Instructions
4_Montagehinweise.fm
Special Installation Notes
Replacing the CSPCI/CCDAX in the 30" Shelf with an EcoServer
1. Now push the two adapter frames from the rear into the server shelf so that
the plates are fitted to the left and right of the frame as shown in the next
diagram (yellow marking).
Figure 16 Pushing the adapter frame into the shelf from the rear
2. Now tightly screw the pre-assembled front retaining plates for the EcoServer
to the front of the adapter frame using 5 screws each.
Fixing screws
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 83
4_Montagehinweise.fm
Special Installation Notes
Replacing the CSPCI/CCDAX in the 30" Shelf with an EcoServer
NOTE: The rear air baffles have to be installed as shown in Figure 19 for using
the DCDR. Install the DCDR at the position where the front four air baffles are
positioned. See also Figure 18.
1. First secure two air baffles at the front (can also be used as a support for the
EcoServer) to the left and right at the bottom of the shelf, as shown in the next
diagram.
2. Now likewise secure two air baffles each to the bottom left and right at the rear
of the processor shelf.
A31003-H3170-J100-2-7631, 05/2015
84 OpenScape 4000 V7, Installation Instructions
4_Montagehinweise.fm
Special Installation Notes
Replacing the CSPCI/CCDAX in the 30" Shelf with an EcoServer
1. Push the EcoServer from the front into the processor shelf and screw it tightly
to the front plate left and right using two screws each.
2. Now secure the upper air baffles above the EcoServer (unless in duplex
mode) on the left side only, as viewed from the front. Because the EcoServer
fan is positioned on the right, no air baffles may be installed on the right so
that the warm air can escape freely upwards.
NOTE: If two EcoServers are installed (in duplex mode), no air baffles may be
installed at the top.
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 85
4_Montagehinweise.fm
Special Installation Notes
Replacing the CSPCI/CCDAX in the 30" Shelf with an EcoServer
3. Now secure the front and rear cover of the shelf again.
The DCDR (incl. its DC cable) is used to connect the EcoServer to the DC supply,
similar to the wiring of the previous cPCI shelf. An additional DCDR can be used
if necessary (e.g. EcoServer duplex with redundant DC PSU -> 4x DC inputs).
.
Figure 22 DC connection of EcoServer with DCDR (DC kit for 30" cabinet)
A31003-H3170-J100-2-7631, 05/2015
86 OpenScape 4000 V7, Installation Instructions
4_Montagehinweise.fm
Special Installation Notes
Shielding Connection on the Opening of the LTU Frame
NOTE: The shield of all front cables (except network cables and optical fiber
cables) must be secured to the frame with two cable ties at the shelf opening.
IMPORTANT: System cables with pre-stripped sections must be used for LTU
frames.
Part numbers:
• Ferrite core: C39022-Z7000-C16
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 87
4_Montagehinweise.fm
Special Installation Notes
Attaching the Ferrite
2. Take the mains cable and make a loop so that the mains cable runs twice
through the ferrite core.
A31003-H3170-J100-2-7631, 05/2015
88 OpenScape 4000 V7, Installation Instructions
4_Montagehinweise.fm
Special Installation Notes
Attaching the Ferrite
3. Now close the ferrite core by pressing the two halves together without
clamping the cable. The ferrite core must be closed fully (see Section 4.7.3,
“Description and Handling of Ferrite Core”).
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 89
4_Montagehinweise.fm
Special Installation Notes
Attaching the Ferrite
2. Use a cable tie (part no.: PNQ:5VC1036026) with metal shield in order to
make a 360° shield connector and secure this around the two DC cables.
3. Secure the DC cable shield to the cord grip provided on the housing for this
purpose (6) using the cable tie.
A31003-H3170-J100-2-7631, 05/2015
90 OpenScape 4000 V7, Installation Instructions
4_Montagehinweise.fm
Special Installation Notes
Attaching the Ferrite
4. Lay the opened ferrite core below the mains cable as close as possible to the
housing.
5. Take the DC cables and make a loop so that the two DC cables runs twice
through the ferrite core.
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 91
4_Montagehinweise.fm
Special Installation Notes
Attaching the Ferrite
6. Now close the ferrite core by pressing the two halves together without
clamping the cable. The ferrite core must be closed fully (see Section 4.7.3,
“Description and Handling of Ferrite Core”).
A31003-H3170-J100-2-7631, 05/2015
92 OpenScape 4000 V7, Installation Instructions
4_Montagehinweise.fm
Special Installation Notes
Attaching the Ferrite
To close the ferrite core, press the two halves firmly together without clamping the
cable. The ferrite core must be closed fully.
NOTE: The ferrite core must be closed fully, with no air slots or air gaps. You can
check this by looking sideways through the ferrite core. No air slot should be
visible and none of the cables should be clamped between the two halves of the
ferrite core.
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 93
4_Montagehinweise.fm
Special Installation Notes
Attaching the Ferrite
To open the ferrite core, press the key tool firmly into the slot on the housing of
the ferrite core until the housing opens. Then simply press open the two halves.
Figure 35 Pressing the key tool into the housing of the ferrite
A31003-H3170-J100-2-7631, 05/2015
94 OpenScape 4000 V7, Installation Instructions
5_Aufstellungsvarianten.fm
Installation Variants
30" Standard Cabinet Installation
5 Installation Variants
This chapter provides schematic representations for the various OpenScape
4000 system installations. For illustrations or IPDA installations, refer to the
associated chapter. Unless otherwise noted, all illustrations apply to both U.S.
and I.M. installations.
IMPORTANT: Each cabinet, including the front cover, forms a shielded unit.
Cabinets should be locked while the system is running and the cover should be
replaced following testing and maintenance.
125 mm 90 mm
110 mm
460 mm
550 mm
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 95
5_Aufstellungsvarianten.fm
Installation Variants
Multiple Cabinet Installation
500
25 1840
1415
400
1015
400
615 65
525 335
15 125
25 90
65
A31003-H3170-J100-2-7631, 05/2015
96 OpenScape 4000 V7, Installation Instructions
5_Aufstellungsvarianten.fm
Installation Variants
AC-to-DC Power Box Installation
1310
610
700
90
550
720
650
Figure 3 UACD
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 97
5_Aufstellungsvarianten.fm
Installation Variants
DC-to-DC Power Box Installation
Z Z Z
1535
Y Y Y I
O
D T T T C UDCD(b)
P R R R B
O O O P 610
N N N
Z Z Z 925
O Y Y Y I
D T T T C
R R R
P
O O O
B
P
UDCD(a)
N N N
315
BUA 225 Base unit
90
Front view 550
720 650
Figure 4 UDCD
A31003-H3170-J100-2-7631, 05/2015
98 OpenScape 4000 V7, Installation Instructions
5_Aufstellungsvarianten.fm
Installation Variants
Free-Standing Installation
IMPORTANT: The CSPCI box, including the front cover, forms a shielded unit.
Free slots must be covered.
Stack4
#)Cable duct
Rec. size 110 x 60mm UP/UPR 15
(L80XF/LTUW)
-> Reference point
Stack1
= Basic configuration UP/UPR
UP/UPR 3 (L80XF/LTUW)
(L80XF/LTUW)
450
UP/UPR
MDF- MDF- UP/UPR (L80XF/LTUW)
HX6 HX6 (L80XF/LTUW)
(n) (1) UP/UPR 12
or or UP/UPR 1 (L80XF/LTUW)
1305 (L80XF/LTUW)
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 99
5_Aufstellungsvarianten.fm
Installation Variants
Free-Standing Installation
#)Cable duct
Rec. size 110 x 60mm
-> Reference point HE = Height unit in 19" SR
19”
450
= Basic configuration
Stack4
Stack1
UP/UPR 15
UP/UPR 4 (L80XF/LTUW)
CSPCI/
4HE
(L80XF/LTUW)
450 EcoServer
UP/UPR
MDF- MDF- UP/UPR (L80XF/LTUW)
HX6 HX6 (L80XF/LTUW)
(n) (1)
or UP/UPR 13
or 1305 UP/UPR (L80XF/LTUW)
(L80XF/LTUW)
745 UP/UPR 1
(L80XF/LTUW)
#)
#) #)
A31003-H3170-J100-2-7631, 05/2015
100 OpenScape 4000 V7, Installation Instructions
5_Aufstellungsvarianten.fm
Installation Variants
Free-Standing Installation
2700
MDFHX6 175 MDFHX6
= Basic configu-
1000 ration
Ref.point Cable duct
= Ref.pt.
max. 2 Stack 1 Stack 2 Stack 3 Stack 4 f.sys.cable
SRR 01 800
UACD 4 U... 4 UP... 4 UP.... 4 UP...
SRR = Row of
SR 105 101 102 103 104 cabinets
773 Expansion 1000 SR = Cabinet
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 101
5_Aufstellungsvarianten.fm
Installation Variants
Cabling Diagram, I.M.
16
-
9
8
-
1 UP
16 UPR
- 16
9 -
9
-8 -
8
1
UP1 UP
16
- UPR -
16 UPR
9 9
8 8
- -
1 1
UP UP
16 UPR
- UPR 16
9 -
-8 8
9
1 -
1 UP
MDFHX6 UP
UPR UPR
(1)
MDFHX6
Stack
(6) UCS
2, 3, 4
(CSPCI /
EcoServer)
Stack
1
A31003-H3170-J100-2-7631, 05/2015
102 OpenScape 4000 V7, Installation Instructions
5_Aufstellungsvarianten.fm
Installation Variants
Shelf Configuration
Slot Modules
5/6 DSCXL2+ (CC-B) •
2x DSCXL2+: S30122-X8004-X39
HDTR2: S30122-X8007-X4
PSU:ACPCI / DCPCI
Fan:C39165-A7070-B14
RTM: S30810-Q2312-X (back)
MCM: S30810-Q2313-X (back)
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 103
5_Aufstellungsvarianten.fm
Installation Variants
Shelf Configuration
Slot Modules
5/6 Panel •
DSCXL2+: S30122-X8004-X39
HDTR2: S30122-X8007-X4
PSU:ACPCI / DCPCI
Fan:C39165-A7070-B14
RTM: S30810-Q2312-X
MCM: S30810-Q2313-X
A31003-H3170-J100-2-7631, 05/2015
104 OpenScape 4000 V7, Installation Instructions
5_Aufstellungsvarianten.fm
Installation Variants
Shelf Configuration
5.7.2 EcoServer
The EcoServer is designed as an autonomous 19" solution. The system is used
as a standalone system or in (19" and 30") cabinets.
NOTE: Please refer to the hardware description in the "OpenScape 4000 Service
Manual" for information on replacing the individual components.
7 CAUTION
It is not permitted to open the housing cover. If the seal on the housing is
removed or broken, the device warranty is automatically invalidated.
Figure 9 EcoServer
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 105
5_Aufstellungsvarianten.fm
Installation Variants
Shelf Configuration
A31003-H3170-J100-2-7631, 05/2015
106 OpenScape 4000 V7, Installation Instructions
5_Aufstellungsvarianten.fm
Installation Variants
Shelf Configuration
Front
Back
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 107
5_Aufstellungsvarianten.fm
Installation Variants
Shelf Configuration
NOTE: There are no installation requirements to be noted for the EcoServer for
the 19" installation. It can be installed at any height in the cabinet. It must simply
be ensured with a duplex variant that both EcoServers are installed directly above
one another since the cross-connect cable that connects the two EcoServers is
only 130mm long.
7 CAUTION
In the case of cabinet installation, the EcoServer must not be weighed down
with other components/devices. The installation accessory is only
designed for the EcoServer and cannot bear the weight of additional
hardware.
AP 3700
A31003-H3170-J100-2-7631, 05/2015
108 OpenScape 4000 V7, Installation Instructions
5_Aufstellungsvarianten.fm
Installation Variants
Shelf Configuration
NOTE: With the 30" variant, the EcoServer is installed at the same position at the
bottom of the first cabinet as otherwise the case with the CSPCI and CCDAX.
LTUW
#
Peripheral Peripheral modules
modules
PSUP
LTUCA
PSUP
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 109
5_Aufstellungsvarianten.fm
Installation Variants
Shelf Configuration
L80XF
Peripheral Peripheral
LPC80
LTUCA
modules
PSUP
modules
Figure 16 UP Cabinet
5.7.5 AP 3700-9
Part number: S30805-G5412-X
IMPORTANT: Only two power supplies are needed. The third LUNA2 is used for
a redundant power supply.
A31003-H3170-J100-2-7631, 05/2015
110 OpenScape 4000 V7, Installation Instructions
5_Aufstellungsvarianten.fm
Installation Variants
Shelf Configuration
Slots
1 2 3 4 5 6 7 8 9 10
• Slot 5-1: Patch panels (8-, 20- and 24-port RJ45 connectors/CHAMP
connectors)
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 111
5_Aufstellungsvarianten.fm
Installation Variants
Shelf Configuration
DSCXL2+ module
Panel
A31003-H3170-J100-2-7631, 05/2015
112 OpenScape 4000 V7, Installation Instructions
5_Aufstellungsvarianten.fm
Installation Variants
Shelf Configuration
Slots
10 9 8 7 6 5 4 3 2 1
IMPORTANT: Only three power supplies are needed. The fourth LUNA2 is used
for a redundant power supply.
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 113
5_Aufstellungsvarianten.fm
Installation Variants
Shelf Configuration
Slots
1 2 3 4 5 6 7 8 9 10 11 12 13 14
max. 4x LUNA 2
(Power Supplies)
• Slot 6-1: Patch panels (8-, 20- and 24-port RJ45 connectors/CHAMP
connectors)
• Ground connector
A31003-H3170-J100-2-7631, 05/2015
114 OpenScape 4000 V7, Installation Instructions
5_Aufstellungsvarianten.fm
Installation Variants
Shelf Configuration
Slots
14 13 12 11 10 9 8 7 6 5 4 3 2 1
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 115
5_Aufstellungsvarianten.fm
Installation Variants
Installation with AP 3700 Cabinets
UACD 2
PDPX2 LPC 1 LPC 2 LPC 3 ACDPX
Stack 3/
4
UACD 1
PDPX2 LPC 1 LPC 2 LPC 3 ACDPX
Stack
1/2
The connection is via a cable from the RTM board/RTMx module on the CSPCI/
EcoServer processor shelf to the LTUCA board in the expansion cabinet (see
Figure 23).
A31003-H3170-J100-2-7631, 05/2015
116 OpenScape 4000 V7, Installation Instructions
5_Aufstellungsvarianten.fm
Installation Variants
Installation with AP 3700 Cabinets
UP/UPR 1
AP 3700-13(13 slots)
(L80XF/LTUW)
only in 19" cabinet
UCS
CSPCI / AP3700-13 L *-G5413-X
EcoServer T
RTM U
C
A
LUNA LUNA LUNA LUNA
2 2 2 2
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 117
5_Aufstellungsvarianten.fm
Installation Variants
Installation with AP 3700 Cabinets
NOTE: The installation instructions below apply equally for closed cabinets and
open racks.
The standard commercial 19" cabinets used for server and network applications
in the IT sector are suitable for installing the OpenScape 4000 components.
The elements installed in the cabinet must be accessible from the back and front.
Cabinets that allow 19-inch components to be installed from the back and front
should be used (>= 4 vertical struts).
In accordance with the relevant vendor’s selected rack program, the following
parts and devices must/can be obtained from the rack vendor:
In line with the planned configuration, cabinets with the appropriate number of
rack units (Us, 1 U = 44.45 mm) should be selected.
A31003-H3170-J100-2-7631, 05/2015
118 OpenScape 4000 V7, Installation Instructions
5_Aufstellungsvarianten.fm
Installation Variants
Installation with AP 3700 Cabinets
If AP 3700 IP and AP 3700 boards are to be installed, the cabinet must have
sliding rails/supporting rails with a minimum load-bearing capacity of 40 kg.
The 19" installation brackets supplied should be used to fix the components to the
cabinet struts.
CSPCI requires 4 HEs and should preferably be placed in the bottom of the rack.
Enough space should be allowed for ventilation (air drawn in from the left, air
escapes on the right).
If there are more than two AP 3700-* boards, a 19" fan unit (1 U) must be used.
The required air flow rate of at least 600 m3/h should be ensured.
If necessary, it is possible to install a second fan unit (if redundancy is desired but
not mandatory).
A minimum clearance of 2 HEs should be allowed between the CSCPI and the
AP 3700-* board
The cabinets should be chosen and configured so that there is sufficient air circu-
lation.
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 119
5_Aufstellungsvarianten.fm
Installation Variants
Installation with AP 3700 Cabinets
In the case of DC systems (48V), you must ensure that a fused 16 A connection
is used.
A31003-H3170-J100-2-7631, 05/2015
120 OpenScape 4000 V7, Installation Instructions
5_Aufstellungsvarianten.fm
Installation Variants
Installation with AP 3700 Cabinets
25
24
23
22
21
20
19
18
17
16
15
14
13
DCDR DCDR
12
11
10
09
08
07 AP 3700 (1)
AP 3700 (1)
06
05
04
03
02
01
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 121
5_Aufstellungsvarianten.fm
Installation Variants
Installation with AP 3700 Cabinets
37
36
35
34
33 AP 3700
HiPath (5) (3)
3700
32
AP 3700 (2) HiPath 3700 (2)
31
30
29
28
27
26 Lüfter / Fans
25
24
23
DCDR
22
AP 3700 (4)
21
20
19
18
17
AP 3700 (1) 16
15
14
13 DCDR
12
11
10
09
08
07
06 AP 3700 (3)
05
04
03
CSPCI
02
01
A31003-H3170-J100-2-7631, 05/2015
122 OpenScape 4000 V7, Installation Instructions
5_Aufstellungsvarianten.fm
Installation Variants
Installation with AP 3700 Cabinets
41
40
39
AP 3700
HiPath (3)(3)
3700 38 AP 3700
HiPath (6)(3)
3700
37
36
35
34
33
32
Lüfter / Fans 31 Lüfter / Fans
30
29
28
27
AP 3700 (2) 26 AP 3700 (5)
25
24
23
22
21
20
DCDR 19 DCDR
18
17
16
15
14
13
AP 3700 (1) 12 AP 3700 (4)
11
10
09
08
07
Lüfter / Fans redundant 06 Lüfter / Fans redundant
05
04
03
CSPCI
02
01
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 123
5_Aufstellungsvarianten.fm
Installation Variants
Installation with AP 3700 Cabinets
A31003-H3170-J100-2-7631, 05/2015
124 OpenScape 4000 V7, Installation Instructions
5_Aufstellungsvarianten.fm
Installation Variants
MDFHX 6 Mounting Location, I.M.
33 +1
Appro Drill template supplied
x.4 3)
MDFHX 6 MDFHX 6
1100 1) 1305 2)
420 1)
450 2)
4) 1) Mounting dimensions
20
2) Clipping dimensions
3) Distance between MDF HX units
4) Minimum distance from floor
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 125
5_Aufstellungsvarianten.fm
Installation Variants
MDFHX 8 Mounting Location, I.M.
33 +1
Appro Drill template supplied
x.4 3)
MDFHX 8 MDFHX 8
530 1) 745 2)
420 1)
450 2)
20 4) 1) Mounting dimensions
2) Clipping dimensions
3) Distance between MDFHX units
4) Minimum distance from floor
A31003-H3170-J100-2-7631, 05/2015
126 OpenScape 4000 V7, Installation Instructions
6_Erdung.fm
Grounding the OpenScape 4000
This means it is extremely important for safety that a second ground is installed
in addition to the ground wire on the supply according to the instructions in this
installation guide. This guarantees the protection of boards from atmospheric
overvoltages / lightning strikes even when the mains plug is removed and the
overvoltage is coupled via the connected station and trunk lines. This is the only
set-up that protects users from electric shocks.
If the system is not grounded correctly, potential differences in the system when
a critical switching threshold of voltage levels is reached can cause faults. Ground
loops resulting from differing ground potentials in the ground busbars (fixed
ground connection) and in the PE wires on the power supply unit should be
prevented by implementing measures in the electro-installation (see Section 6.5,
"System Ground Connections (19" variant)").
• Fixed ground connections are laid from the grounding point in the OpenScape
4000 housing directly to the ground busbar for the building.
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 127
6_Erdung.fm
Grounding the OpenScape 4000
Grounding the Main Distribution Frame (MDF)
• Please ensure that the PE ground wire supplied due to the connection of the
230V/110V power supply network has the same potential as the fixed ground
connection. This is guaranteed when both ground wires are branched by the
same ground busbar in the building installation and cannot create potential
differences en route to the connection to OpenScape 4000.
NOTE: The main distribution frames must be connected directly to the ground
busbar. No ground connection should be established directly between the main
distribution frame and the base cabinet.
1
Ground conductor from
ground busbar to MDF
A31003-H3170-J100-2-7631, 05/2015
128 OpenScape 4000 V7, Installation Instructions
6_Erdung.fm
Grounding the OpenScape 4000
Connecting and Grounding the Boxes in the 30" Cabinet
Power box
CSPCI or
EcoServer
1. Position the individual stacks and the power box according to the site to avoid
repositioning them later.
2. Using the supplied ground straps (1), determine the correct distance between
the roller bases by inserting the straps in adjacent bases (see Figure 3).
3. Attach the various ground straps to the left (2) and right (3) of the roller base
using the screws that are provided.
1 2 3
Figure 3 Installing the ground strap at the base of the cabinets
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 129
6_Erdung.fm
Grounding the OpenScape 4000
Connecting and Grounding the Boxes in the 30" Cabinet
7 WARNING
Risk of electric shock as a result of an incorrect grounding conductor
connection
Never operate the system without the specified straps. The strapping serves as
an internal grounding conductor connection for the individual components.
2. Insert the supplied ground straps (2) and tighten the screws.
1 2
3 4
A31003-H3170-J100-2-7631, 05/2015
130 OpenScape 4000 V7, Installation Instructions
6_Erdung.fm
Grounding the OpenScape 4000
Grounding the System (30" cabinet)
An internal ground conductor between the base cabinet and the expansion
cabinets is supplied ex-works. See Figure 6.
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 131
6_Erdung.fm
Grounding the OpenScape 4000
Grounding AP 3700 System Cabinets
• Connect the ground conductor directly from the ground busbar to the
grounding connector.
AP 3700-9 AP 3700-13
Grounding connectors
Figure 7 AP 3700-9/AP 3700-13 grounding connectors
A31003-H3170-J100-2-7631, 05/2015
132 OpenScape 4000 V7, Installation Instructions
6_Erdung.fm
Grounding the OpenScape 4000
System Ground Connections (19" variant)
AP 3700
230V
AP 3700
230V
AP 3700
230V Equipotential
bonding
CSPCI/
EcoServer PE*
230V
PE*
3
PE
Equipment room –
230V power distributor Ground busbar
UPS PE*
Building/room –
Ground busbar
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 133
6_Erdung.fm
Grounding the OpenScape 4000
System Ground Connections (19" variant)
AP 3700
AP 3700
PE* PE
-48 V N
CSPCI/ L
0V
EcoServer
PE* PE*
Equipotential
bonding
conductor Equipment room –
Ground busbar
Cable shield
PE*
PE*) cross sections in accordance Building/room –
with national regulations Ground busbar
e.g. (DIN EN 50310)
A31003-H3170-J100-2-7631, 05/2015
134 OpenScape 4000 V7, Installation Instructions
6_Erdung.fm
Grounding the OpenScape 4000
System Ground Connections (19" variant)
MDF
AP 3700
230V
PE*
CSPCI/EcoServer
230V
Equipo-
3 tential
bonding
conductor PE*
PE
Equipment room –
230V power distributor Ground busbar
UPS PE*
Building/room –
Ground busbar
PE*) cross sections in accordance
with national regulations
e.g. (DIN EN 50310)
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 135
6_Erdung.fm
Grounding the OpenScape 4000
System Ground Connections (19" variant)
CSPCI/EcoServer 3
-48 V
0V Cable shield
EB PE*
PE
N
PE* L
Equipment room –
Ground busbar
PE*
A31003-H3170-J100-2-7631, 05/2015
136 OpenScape 4000 V7, Installation Instructions
6_Erdung.fm
Grounding the OpenScape 4000
System Ground Connections (19" variant)
Figure 14 and Figure 15 show a diagram of the system ground connections with
the corresponding ground straps.
2xUACD Stack 1
MDF
~~
3) 2)
1)
PE cable 352
Battery
gnye +
-
Ground busbar 1) Ground strap C39165-A7080-C146
2) Ground strap C39165-A7080-C22
3) Attach PE line
Figure 14 Schematic representation of OpenScape 4000 system ground
connections
Figure 15 shows how the ground connector is connected to the 0-V busbar on the
30" cabinet
Figure 15 Ground connection from ground busbar to the 0-V busbar on the 30"
cabinet
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 137
6_Erdung.fm
Grounding the OpenScape 4000
System Ground Connections (19" variant)
A31003-H3170-J100-2-7631, 05/2015
138 OpenScape 4000 V7, Installation Instructions
7_Netzanschluss.fm
Connecting to the Mains and Power Supply
Connecting to the Mains
7 WARNING
Electric shock due to disconnected ground wire!
The grounding wire of the in-house power connector must always be connected
to the mains power socket first.
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 139
7_Netzanschluss.fm
Connecting to the Mains and Power Supply
Connecting to the Mains
OpenScape 4000 has been designed to accept four different types of power
supply worldwide as follows:
7 WARNING
Safety cannot be guaranteed if the mains plugs are inaccessible.
The mains plug must be easily and safely accessible in all installation variants.
Unplug the mains plug immediately in the event of danger!
7 WARNING
Electric shock due to disconnected ground wire!
Before starting up the system and connecting the stations, connect the system
correctly to the ground wire.
Never operate the system without the required ground wire.
A31003-H3170-J100-2-7631, 05/2015
140 OpenScape 4000 V7, Installation Instructions
7_Netzanschluss.fm
Connecting to the Mains and Power Supply
Connecting to the Mains
IMPORTANT: In Canada and U.S., only L1, L2, and PE are brought to the wall
socket. The neutral lead for 208 Vac power is not brought to the wall socket.
Fuse Fuse
16 A 16 A
L1
L2 3-phase network
L3
~ 230 V/400 V
N
PE
Fuse
16 A
PE N L1
This part of the illustration (L3)
applies to Europe and GNYE BU BK1
gnye bu bk
International character code for
I.M.
colors
Cable 3x1.52
LPC80/LUNA
The power cables should already be installed in new systems. Should the AC-to-
DC shelf power supply cables become unplugged during transit, route the power
cable in a OpenScape 4000 as follows:
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 141
7_Netzanschluss.fm
Connecting to the Mains and Power Supply
Connecting to the Mains
2. Plug the power cable into the AC-to-DC shelf power shelf supplies ( LPC80).
3. Route the power cable through the metal knock-out (see Figure 2) and to the
back of the system.
NOTE:Two cable ties are required for proper EMI (electromagnetic inter-
ference) grounding.
5. Route and plug the other end of the power cable to the mains socket (AC
outlet) in the base unit (BAU) under the shelf (see Figure 3).
6. Repeat this procedure to the L80XF (expansion) cabinets if you have a multi-
cabinet installation.
IMPORTANT: Figure 3 shows an illustration for the I.M. Canada and U.S. use a
different outlet strip.
A31003-H3170-J100-2-7631, 05/2015
142 OpenScape 4000 V7, Installation Instructions
7_Netzanschluss.fm
Connecting to the Mains and Power Supply
Connecting to the Mains
In the case of the redundant power supply variant, the connection is made to the
mains using a power connector socket on the power box. Depending on the local
power supply, you may need to make a distinction between the different
connection variants.
1. Remove the shielded power line with connection box from the power box
(Powershelf 1 or Powershelf 2) and remove the cover of the mains socket.
Powershelf 1 Powershelf 2
Figure 4 Connecting to the mains using the power box
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 143
7_Netzanschluss.fm
Connecting to the Mains and Power Supply
Installing a Three-Phase Network
7 WARNING
Electric shock due to disconnected ground wire!
Before you connect the three-phase power cable (~230 V/400 V), ensure that the
protective ground terminal (building ground) is connected to the system frame.
3. Insert the open end of the power cable through the junction box.
4. Strip the wires on the power cable, insert, and secure the wires to the
terminals as follows: (see Figure 5 and Figure 6):
d) Attach each of the two black wires that emerge from the mains cable to a
separate (BK) terminal on the distribution socket.
5. Tighten the screw on the junction box and replace the cover.
A31003-H3170-J100-2-7631, 05/2015
144 OpenScape 4000 V7, Installation Instructions
7_Netzanschluss.fm
Connecting to the Mains and Power Supply
Installing a Single-Phase Network
bk BK(L2)
bn BN(L1)
bu BU(N)
gnye GNYE(PE)
7 WARNING
Electric shock due to disconnected ground wire!
Before you connect the single-phase power, ensure that the protective ground
terminal (building ground) is connected to the system frame.
3. Insert the open end of the power cable through the junction box.
4. Strip the wires on the power cable, insert, and secure the wires to the
terminals as follows:
b) Connect the power switches 1, 2 and 3 to the ACDPX in the power supply
frame of the UACD, as shown in the Figure 7.
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 145
7_Netzanschluss.fm
Connecting to the Mains and Power Supply
Overview of Mains Connection 1
*)
PE cable
PE N L1 L2 L3 must be PE N L1 L3
L2
GNYE BU BK2
connected GNYE BU BK2
gnye bu BN BK1bk2 gnye bu BN BK1 bk2
Cable with bn bk1 International color cable bn bk1
terminal box codes
C39195-A7970-B19
ACDPX
PSU CB
1 /2 /3 1
11 21
UACD
2
11 21
3
11 21
L1 2 3 N PE
*) Insert additional jumper
A31003-H3170-J100-2-7631, 05/2015
146 OpenScape 4000 V7, Installation Instructions
7_Netzanschluss.fm
Connecting to the Mains and Power Supply
Installing a Three-Phase or Single-Phase Connection with Mid-Point Grounding, I.M.
7 WARNING
Electric shock due to disconnected ground wire!
Before you connect the power phases, make sure that the protective ground
terminal (building ground) is connected to the system frame.
3. Insert the open end of the power cable through the junction box.
4. Strip the wires on the power cable, insert, and secure the wires to the
terminals as follows:
a) Insert and secure the blue (BU) and brown (BN) wires together in the
junction box.
c) Connect the power switches 1, 2 and 3 to the ACDPX in the power supply
frame UACD, as shown in the Figure 8.
7 WARNING
Electric shock due to the connection of unapproved systems!
Only one OpenScape 4000 DC system with a 25A fuse may be connected per
stack to the UACD.
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 147
7_Netzanschluss.fm
Connecting to the Mains and Power Supply
Overview of Mains Connection 2, I.M.
L1 Single-phase
3-phase network L2 network A
~ 120 V/208 V L3 midpoint grounding B
~ 127 V/220 V N ~ 110/220 V N(PE)
PE ~ 120/240 V
Fuse
25 A
Cable 3x42
PE cable must
be connected
*) Reconnect
N L3 L1 N
(PE) (n) (PE) B A
ACDPX
PSU CB
1 /2 /3 1
11 21
UACD
2
11 21
3
11 21
L1 N
PE
*) For information on reconnecting, see also diagram:
a) mains socket: V32905-A2-X399
b) ACDP/ACDPX: V32905-A2-X206!
A31003-H3170-J100-2-7631, 05/2015
148 OpenScape 4000 V7, Installation Instructions
7_Netzanschluss.fm
Connecting to the Mains and Power Supply
Power Supply
NOTE: The contact area of all power supply cables must be bonded with two
cable fasteners each (see Figure 80 on page 222).
The DC power supply usually has a voltage of –48 V. However, some modules
require –60 V. A power supply module (APPS) is used in this case. This -60-V
power supply is only provided for individual shelves.
NOTE: Never plug in or unplug the APPS module when the power is on.
2. If your system features redundant CPUs: Connect the power cables to the
AC/AC power management unit (LPC80).
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 149
7_Netzanschluss.fm
Connecting to the Mains and Power Supply
AC Connection to Power Supplies
3. Route the power cables (1) downwards through the frame's metal knock-out
(2) (see Figure 9) to the base unit assembly (BUA) below the CSPCI/
EcoServer shelf.
4. Secure the power cables with tie-wraps on the metal knock-outs (3).
5. Plug the other end of the power cables to the ac outlet in the BUA.
2 1
3
Figure 9 OpenScape 4000 AC installation
1. Remove the fixing screws (1) from the MCM board on the back of the CSPCI
box and remove the board (see also Figure 10).
2. Insert the power cable in the socket (2) on the CSPCI box and secure it to the
cord grip (3) with a cable tie.
3. Route the power cable through the cable duct (4) on the MCM board and
screw the MCM board back onto the CSPCI shelf.
A31003-H3170-J100-2-7631, 05/2015
150 OpenScape 4000 V7, Installation Instructions
7_Netzanschluss.fm
Connecting to the Mains and Power Supply
AC Connection to Power Supplies
2
1 3
4
Figure 10 Attaching the power cable to the CSPCI box
NOTE: A ferrite core must be attached to the relevant AC mains cable in order to
prevent the system being impacted by external atmospheric interferences, such
as radiation (see Section 4.7, "Attaching the Ferrite").
Stack 1 Stack 4
UP UP
LPC L80XF LPC L80XF
80 BAT PS 80 BAT PS
# = S30805-H5284- UP UP
* = S30805-H5298- Talk Talk
Bulk Bulk
$ = C39195-A .... UP
UP
~ LPC
~ LPC L80XF
80 BAT PS 80 BAT PS
UP PE UP
Talk Talk
Bulk $ -A7650-B35 Bulk
UP UP
~ LPC L80XF PS ~ LPC L80XF PS
80 BAT 80 BAT
UP UP
Talk Talk
Bulk Bulk
CSPCI Box UCS
UP
~ UP
LPC L80XF
1) ~ CSPCI Box / 80 BAT PS
UP
EcoServer Talk
MCM Bulk
equipo-
#-X12PE PE #-X12 PE
230/115V ~
~ AC AC
2) 3) -48V 3) -48V
MDF MDF
PE
MDF-
HX6
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 151
7_Netzanschluss.fm
Connecting to the Mains and Power Supply
AC Connection to Power Supplies
Stack 1 *-X11
Stack 4
*-X11
UP UP
LPC L80XF LPC L80XF
PS PS
80 BAT UP 80 BAT UP
# = S30805-H5284- Talk Talk
Bulk Bulk
* = S30805-H5298-
$ = C39195-A .... ~
UP ~ UP
LPC L80XF PS PE LPC L80XF PS
80 BAT UP 80 BAT UP
Talk $ -A7650-B35 Talk
Bulk Bulk
UP UP
~ LPC PS
~ LPC L80XF
L80XF PS
80 BAT UP 80 BAT
UP
Talk Talk
Bulk Bulk
CSPCI Box UCS UP
~ LPC L80XF
~ *-X14 80 BAT PS
UP
MCM 1) CSPCI Box / Talk
EcoServer Bulk
equipo-
#-X12PE PE #-X12 PE
+/-48V ~
AC AC
5) -48V 5)
-48V
PE MDF MDF
2) 3)
MDF- 4)
HX6 UACD
L 1 2 1 2 1 2 1 2 L A
C
P Bulk Talk Talk Bulk P D
C PDPX2(1) PDPX2(2) C P AC
X
BAMX1 BAMX2 EBCCB(2) to battery
EBCCB(1)
A31003-H3170-J100-2-7631, 05/2015
152 OpenScape 4000 V7, Installation Instructions
7_Netzanschluss.fm
Connecting to the Mains and Power Supply
AC Connection to Power Supplies
1 2
NOTE: In case of redundancy, connect a second mains cable to the power supply
(2) and likewise run it downwards to the designated mains socket rail.
Connect the mains cables individually to the designated mains sockets in case of
a standalone connection.
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 153
7_Netzanschluss.fm
Connecting to the Mains and Power Supply
Setting the Operating Mode for the LPC80, I.M.
ON = Battery charger
OFF = Power Supply
Figure 14 shows the switch of the two different power supply units. Set the
operating mode of the power supply unit using this switch.
A31003-H3170-J100-2-7631, 05/2015
154 OpenScape 4000 V7, Installation Instructions
7_Netzanschluss.fm
Connecting to the Mains and Power Supply
Setting the Operating Mode for the LPC80, I.M.
Between standard/ for -K7162- Artesyn: neutral switch, clearly identifiable from
charger mode (on the sticker
back of the LPC80) 1st option: Battery Charger
2nd option: Power Supply Peripheral Shelf:
standard mode forebodes
for -K7163- Celestica: jumper W1, clearly identifiable from
sticker
ON --> connector W1 with J5 --> battery charger
mode
OFF --> connector W1 with
J6 --> standard mode for CAB80DSC
for K7554- Supplier: MagneTek 3-pin connector behind a
window on the underside of the power supply
unit. (2 screws)
1. Connector in "Mode1": as used with peripheral
shelves
2. Connector in "Mode2": as used with battery
chargers
Between two possible for -K7162- Artesyn: jumper setting, clearly identifiable from
voltages (in charger sticker
mode) 1st option: 54.7 V (factory setting)
2nd option: 53.5 V
for -K7163- Celestica: jumper J9, clearly identifiable from
sticker
1st option: connection between pin 3 and pin 4
from J9 --> 54.7V (factory setting)
2nd option: connection between pin 3 and pin 4
from J9 --> 53.5V
for K7554- Supplier: MagneTek Switch on the underside of
the power supply unit; (voltages shown on circuit
board)
- Switch in left position --> 53.5V
- Switch in right position --> 54.7V
Table 1 Operating mode settings of the LPC80
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 155
7_Netzanschluss.fm
Connecting to the Mains and Power Supply
DC Connection with the External Power Supply, I.M.
IMPORTANT: In Canada and U.S., the UPS provides AC power only. It is not a
source of DC power.
An external system power supply (uninterruptible power supply [UPS] in the U.S.)
is a PSU in which a jumper is connected to the system instead of the LPC80
power supply unit (see Figure 19). The jumper feeds the –48 V external power
supply to the system. The external –48V is connected from the DC power box to
the individual backplanes of the system cabinets.
NOTE: Ensure that the cables are locked down, otherwise, the LTU shelf that
is connected to is not going to function properly.
IMPORTANT: The top blue connector bulk cable on top of the CSPCI box
connects to the bottom blue connector of the LTUW cabinet. The top blue
connector bulk cable on the LTUW cabinet connects to the bottom blue
connector of the LTUW cabinet immediately above it and so on.
3. At every cabinet:
Connect and tie-wrap the shielded portion of the –48 Vdc bulk input power
cables to the cabinet frame.
4. At every cabinet:
Connect the -48-Vdc bulk input power cable to the shielded ground at the left
side of each cabinet.
A31003-H3170-J100-2-7631, 05/2015
156 OpenScape 4000 V7, Installation Instructions
7_Netzanschluss.fm
Connecting to the Mains and Power Supply
DC Connection with the External Power Supply, I.M.
6. Connect the -48-Vdc input talk circuit breaker cables to the X11 connector of
the LTUW shelf.
7. Daisy-chain the -48-Vdc input talk circuit breaker cables to the upper LTUW
shelves.
8. At every cabinet:
Connect the -48-Vdc talk input power cable to the shielded ground at the left
side of each cabinet.
Output to
LTUW
shelf
Shielded
ground
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 157
7_Netzanschluss.fm
Connecting to the Mains and Power Supply
DC Connection with the External Power Supply, I.M.
All internal cabling for the UACD and UDCD should be complete when the
equipment goes out of the factory. The output power cables on the UACD and
UDCD are also already connected on the power shelves.
In the UACD or UDCD, the output power cable must be connected to the CSPCI
connector (bottom blue connector of the bulk circuit breaker, see Figure 15).
1. Connect the -48V cable from the external battery to the DC terminal (1) on the
base cabinet (see Figure 16).
2. Route the -48V from the -48V fuse module to the CSPCI backplane (2).
Expansion cabinet
- 48V
Base cabinet
Figure 16 Connecting the external –48V to the DC terminal on the base cabinet
3. Remove the fixing screws from the MCM board (3) on the back of the CSPCI
box and remove the board (see Figure 18).
IMPORTANT: The factory setting for the CSPCI shelf’s power supply coding is
always set to ACPCI. To use DC power supplies (DCPCI), you must change the
coding as indicated in Figure 17.
A31003-H3170-J100-2-7631, 05/2015
158 OpenScape 4000 V7, Installation Instructions
7_Netzanschluss.fm
Connecting to the Mains and Power Supply
DC Connection with the External Power Supply, I.M.
Front
"Duplex" configuration
DSCXL2+
F F
A Blind Panel A
N N
HDTR2
DSCXL2+
Chamber F: empty
Chamber E: empty
Chamber D: Position 1
- DC system 1)
Chamber F: empty
Chamber E: empty
Chamber D: Position 3
5. Strip away the cable insulation from the two DC cables (5) up to the shield (if
not already done in advance).
6. Secure the DC cable shield (use a cable tie with metal shield to get a 360°
shield connector, part no.:PNQ:1036026) to the cord grip provided for this
purpose (6).
7. Route the DC cable out through the cable duct (7) on the MCM board and
screw the MCM board back onto the CSPCI shelf.
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 159
7_Netzanschluss.fm
Connecting to the Mains and Power Supply
DC Connection with the External Power Supply, I.M.
3
4
7
8. Once the -48V cable is connected, check that the correct jumper is plugged
into the designated plug connector for the LPC80 (see Figure 19).
A31003-H3170-J100-2-7631, 05/2015
160 OpenScape 4000 V7, Installation Instructions
7_Netzanschluss.fm
Connecting to the Mains and Power Supply
DC Connection with the External Power Supply, I.M.
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 161
7_Netzanschluss.fm
Connecting to the Mains and Power Supply
DC Connection with UP/L80XF Cabinet, I.M.
Stack 1 Stack 4
*- *- UP
UP
L80XF L80XF
# = S30805-H5284- PS PS
BAT UP BAT UP
* = S30805-H5298- Talk Talk
Bulk Bulk
$ = C39195-A ....
UP UP
with jumpers L80XF PE L80XF PS
PS
BAT UP
Talk
UP $ -A7650-B35 BAT
Talk
Bulk Bulk
UP
UP UP
L80XF
PS
with L80XF PS
BAT UP jumpers BAT UP
Talk Talk
Bulk Bulk
CSPCI Box UCS UP
*-X14 L80XF PS
1) CSPCI Box
BAT UP
MCM Talk
Bulk
equipo- PE PE
+/-48V
#-X12 #-X12 2)
2)
-48V -48V
MDF DC MDF DC
connection connection
PE -48V
-48V
MDFHX
6/8
A31003-H3170-J100-2-7631, 05/2015
162 OpenScape 4000 V7, Installation Instructions
7_Netzanschluss.fm
Connecting to the Mains and Power Supply
AC-to-DC Connection with a Redundant LTUW Cabinet
An external battery connection can also be used to support the power supply.
Stack 1 Stack 4
*-X12 *-X11 *-X12 *-X11
UPR UPR
PS LTUW PS PS LTUW PS
UP UP UP UP
Talk Talk
# = S30805-H5284- Bulk Bulk
* = S30805-H5298-
UPR UPR
$ = C39195-A .... LTUW PS LTUW PS
PS PE PS UP
UP UP UP
Talk $ -A7650-B35 Talk
Bulk Bulk
UPR UPR
PS LTUW PS LTUW PS
PS
UP UP UP
Talk UP Talk
Bulk Bulk
*-X15
CSPCI Box UCS UPR
*-X14 LTUW PS
*-X15 PS UP
Talk
MCM 1) CSPCI Box / UP
Bulk
EcoServer
PE PE
+/-48V
-48V 3) -48V
-48V
MDF MDF
PE UACD (2)
-48V 1 2 1 2
Bulk Talk
L
P
L
P
A
C
D AC
PDPX2 C C P
X
MDFHX 2) BAMX2 EBCCB to battery
6/8
UACD (1)
4) 1 2 1 2 L L A
C
Bulk Talk P P D
PDPX2 C C P AC
X
BAMX1 EBCCB to battery
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 163
7_Netzanschluss.fm
Connecting to the Mains and Power Supply
DC Connection with Redundant UPR/LTUW Box, I.M.
Stack 1 Stack 4
*-X12 *-X11 *-X12 *-X11
UPR UPR
LTUW PS PS LTUW PS
PS UP
# = S30805-H5284- UP Talk UP Talk UP
Bulk Bulk
* = S30805-H5298-
$ = C39195-A .... UPR UPR
LTUW PS LTUW PS
PS PE PS UP
UP UP UP
Talk Talk
Bulk $ -A7650-B35 Bulk
UPR UPR
LTUW PS LTUW PS
PS PS
UP UP UP
1) UP
Bulk
Talk Talk
Bulk *-X15
CSPCI Box UCS UPR
*-X14 LTUW PS
*-X15 PS UP
CSPCI Box / UP Talk
MCM EcoServer
Bulk
2) PE
PE
+/-48V
DC -48V 2) -48V
connection MDF DC MDF
PE -48V connection
-48V
MDFHX
6/8
A31003-H3170-J100-2-7631, 05/2015
164 OpenScape 4000 V7, Installation Instructions
7_Netzanschluss.fm
Connecting to the Mains and Power Supply
DC Connection with Redundant UPR/LTUW Box, I.M.
1. Connect the 0 V supply from the battery to the roller base of the power box
(see Figure 24).
2. Attach the –48 V supply from the external battery to the cable drawn from the
system (see Figure 25).
EBCCB 1
PSU
(EBCCB 2)
ON
LPC
OFF BAMX 1
X6 (X7)
-48 V sense
PDPX2(1)
(PDPX2(2))
POWER
SHARE
Fuse
70 A
ON
OFF
BAMX 1
(BAMX 2)
UBATT
Ext. batt. Items in parentheses indicate
-48 V double configuration in the
power box.
Figure 25 External battery connection to power box (back view)
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 165
7_Netzanschluss.fm
Connecting to the Mains and Power Supply
DC Connection with Redundant UPR/LTUW Box, I.M.
IMPORTANT: In Canada and U.S., the UPS provides AC power only. It is not a
source of DC power.
The power supply for the main distribution frame is branched from extension
boxes 1 and 2 and connected to the main distribution frame by means of fuse
modules (Si1/Si2), each with 1.6 A fuses (see Figure 26 and Figure 27). The –48
V connectors from the MDFs can be combined as required. Ensure that the
number of MDFs connected at a fuse does not exceed the overall power
requirement for each 1.6 A fuse.
MDFHX6 MDFHX6
4/5/6 1/2/3
Backplane L80XF
-48 V -48 V
-48 V Exp. 1 Exp. 2
-48 V
Fuses:
L80XF = 2.0 A
LTUW (X15) = 1.6 A
Figure 27 -48 V fuse module for MDF (nonredundant)
A31003-H3170-J100-2-7631, 05/2015
166 OpenScape 4000 V7, Installation Instructions
7_Netzanschluss.fm
Connecting to the Mains and Power Supply
DC Connection with Redundant UPR/LTUW Box, I.M.
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 167
7_Netzanschluss.fm
Connecting to the Mains and Power Supply
AC-to-DC Connection with AP 3700
A31003-H3170-J100-2-7631, 05/2015
168 OpenScape 4000 V7, Installation Instructions
7_Netzanschluss.fm
Connecting to the Mains and Power Supply
AC-to-DC Connection with AP 3700
AP 3700 AP 3700
LU LU LU LU LU LU LU LU
NA2 NA2 NA2 NA2 2) 2) NA2 NA2 NA2 NA2
FAN FAN
6)
AP 3700 AP 3700
6)
LU LU LU LU LU LU LU LU
NA2 NA2 NA2 NA2 NA2 NA2 NA2 NA2
2)
2)
AP 3700 AP 3700 6)
6)
LU LU LU LU LU LU LU LU
NA2 NA2 NA2 NA2 NA2 NA2 NA2 NA2
2)
FAN 2) FAN
AP 3700 6)
6) *) CSPCI
LU LU LU LU RTM
NA2 NA2 NA2 NA2 MCM
2)
6) *) *)
2)
PE
AC AC
1) 1)
*) Set up a secure star-shaped earth connection from the earth bar to
the cabinet. Secure cable with cable ties.
Figure 31 AC connection AP 3700 in 19" cabinet
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 169
7_Netzanschluss.fm
Connecting to the Mains and Power Supply
AC-to-DC Connection with AP 3700
LU LU LU LU LU LU LU LU
NA2 NA2 NA2 NA2 NA2 NA2 NA2 NA2
7)
FAN module FAN module
AP 3700 6) AP 3700
6)
LU LU LU LU LU LU LU LU
NA2 NA2 NA2 NA2 NA2 NA2 NA2 NA2
7) 8)
(-)
DCDR (-) (-)
DCDR (-)
AP 3700 AP 3700
6)
6)
LU LU LU LU LU LU LU LU
NA2 NA2 NA2 NA2 NA2 NA2 NA2 NA2
7)
FAN module FAN module
AP 3700 6)
7) CSPCI
8)
LU LU LU LU RTM
NA2 NA2 NA2 NA2 6)
MCM
8)
6) PE
10) *) PE *)
DC + / - 48V DC + / - 48V
Connection
*) Set up a secure star-shaped with or without L bridges
earth connection from the earth PE L2+ L1+ L2- L1- PE L2+ L1+ L2- L1-
10)
bar to the cabinet. Secure cable
4a) 4)or5) 4a) 4)or5)
with cable ties.
Figure 32 DC Connection AP 3700 with DCDR (Fuse Unit)
Table 2 lists the cables to be used when the AP 3700 is to have AC/DC wiring in
the 19" cabinet (see the numbers in Figure 31 and Figure 32).
A31003-H3170-J100-2-7631, 05/2015
170 OpenScape 4000 V7, Installation Instructions
7_Netzanschluss.fm
Connecting to the Mains and Power Supply
AC-to-DC Connection with AP 3700
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 171
7_Netzanschluss.fm
Connecting to the Mains and Power Supply
AC-to-DC Connection with AP 3700
LU LU LU LU LU LU LU LU
NA2 NA2 NA2 NA2 NA2 NA2 NA2 NA2
2) 2)
FAN module FAN module
AP 3700 3) AP 3700
3)
LU LU LU LU LU LU LU LU
NA2 NA2 NA2 NA2 NA2 NA2 NA2 NA2
2) 1)
(-)
DCDR (-) (-)
DCDR (-)
1) AP 3700 AP 3700
1)
3)
3)
LU LU LU LU LU LU LU LU
NA2 NA2 NA2 NA2 NA2 NA2 NA2 NA2
2)
FAN module FAN module
AP 3700 3)
2) CSPCI
1)
LU LU LU LU RTM
NA2 NA2 NA2 NA2 3)
MCM
3)
1) PE 1) PE
DC + / - 48V *) / 6)
DC + / - 48V *) / 6)
*) Set up a secure star-shaped earth Connection with or without L
connection from the earth bar to the bridges
central ground connect point on the PE L2+ L1+ L2- L1-
rack (min. cross-section 102)
4) + 5) PE L2+ L1+ L2- L1-
Cable from UACD
+ " -earth bar 1)
-48 V " - bulk/talk
Figure 33 DC connection AP 3700 with DCDR (DC kit for 19-inch cabinet)
A31003-H3170-J100-2-7631, 05/2015
172 OpenScape 4000 V7, Installation Instructions
7_Netzanschluss.fm
Connecting to the Mains and Power Supply
AC-to-DC Connection with AP 3700
2) 1A Si/CB
2)
16 A Si/CB for MDF 16 A Si/CB
L2- L2+ for 3rd + 4th for 1st + 2nd L1+ L1-
Terminal cabinet cabinet Terminal
block block
Table 3 lists the cables to be used for DC wiring in the AP 3700 in the 19-inch
cabinet (see numbering in Figure 33 and Figure 34).
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 173
7_Netzanschluss.fm
Connecting to the Mains and Power Supply
AC-to-DC Connection with AP 3700
Figure 35 shows the DCDR fuse unit for the 19" installation version
Technical specifications
Dimensions: Width = 435 mm,Depth = 205 mm, Height = 90 mm, Installation
height = 2 U
The power supply connection cables are also supplied (see SK S30122-K7698-
X).
Fixing screws for DCDR and the terminal block for rack installation should be
obtained from the rack vendor for the specific rack used.
NOTE: The breaker panel unit DCDR must always be installed above a CSPCI
or AP3700-9/13.
IMPORTANT:
- The approved 16-A automatic circuit breaker (V39118-Z7180-A6) should always
be used to connect the cabinets CSPCI, AP3700-9, and AP 3700-13.
- In the case of LM orders based on the project planning procedures, the 16-A
automatic circuit breakers are automatically planned depending on the configu-
A31003-H3170-J100-2-7631, 05/2015
174 OpenScape 4000 V7, Installation Instructions
7_Netzanschluss.fm
Connecting to the Mains and Power Supply
AC-to-DC Connection with AP 3700
ration.
- For each DCDR, two 1-A automatic circuit breakers (V39118-Z7180-A8) are
provided in advance for the connection of external devices.
- An order with part number is required in all other cases (for example, additional
requirements).
For information on where to install and connect the fuse panel, refer to Figure 36.
Fuse panel
SK -> S30805-H5412-X10
with 2 x 1-A automatic
circuit breakers
OpenScape 4000 *)
AP 3700
-
LU LU LU LU
NA2 NA2 NA2
2) FAN module
6
CSPCI
RTM 11)
MCM on connector X210 for SAPP BB
MDF-HX8/6 (AP3700 IP) or
-UE on connector X212 for SAPP EB
2) (AP3700)
PE
AC
1)
*) Fuse panel can be installed in the following locations:
SAPP BB -> X101 - X104
SAPP EB -> X101 - X106
Figure 36 DC connection of AP 3700 to the MDF
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 175
7_Netzanschluss.fm
Connecting to the Mains and Power Supply
UACD (Lineage Power) 19-Inch Installation
The UACD power box (Lineage Power) is a new AC/DC power box for use in 19-
inch cabinets which replaces the old UACD (PSR930/PSR930E).
IMPORTANT:
- The new UACD power box may only be serviced by authorized service personal.
- All UACD lines (in the 19” cabinet) must be secured with an appropriate cord
grip (e.g. cable tie).
A31003-H3170-J100-2-7631, 05/2015
176 OpenScape 4000 V7, Installation Instructions
7_Netzanschluss.fm
Connecting to the Mains and Power Supply
UACD (Lineage Power) 19-Inch Installation
- Load Breakers
- Battery Breaker
NOTE: The equipment comes with all circuit breakers already equipped!
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 177
7_Netzanschluss.fm
Connecting to the Mains and Power Supply
UACD (Lineage Power) 19-Inch Installation
The UACD expansion cabinet (UACD Scondary Shelf) has the same structure as
the base cabinet minus the base controller.
IMPORTANT:
- Before starting up the power, ensure that all rectifiers’ modules on the front are
securely screwed into the shelf to guarantee a secure contact.
7 WARNING
Risk of injury resultig from following items:
- Be aware of the presence of unfused battery potential in the vicinity.
- Use only insulated tools.
- Make sure the system is properly grounded per the National Electrical Code and
local building codes.
- Remove all metal jewelry before beginning the installation.
Installation Material:
• Wire cutters and strippers
• 18 to 22 AWG wire
A31003-H3170-J100-2-7631, 05/2015
178 OpenScape 4000 V7, Installation Instructions
7_Netzanschluss.fm
Connecting to the Mains and Power Supply
UACD (Lineage Power) 19-Inch Installation
Hardware:
Attach each shelf to the frame using a minimum of four (two on each side) of the
12-24 screws included with the shelf. Torque to 30 in-lbs using 5/16” nut driver.
Allow a minimum 2 inch clearance at back of shelf for rectifier airflow, no vertical
spacing is required.
Wiring Guidelines:
All wiring is located on the rear of the shelf:
• dc output wiring,
• LAN port
Make all electrical connections using the proper crimping tools and dies. Torque
to values specified. Verify all wiring complies with the NEC and other applicable
local codes. The temperature rating of the wire must be no less than 90° Celsius
and should be sized using the 60° Celsius ampacity table in the NEC handbook.
7 DANGER
Risk of electric shock through contact with live wires
Only qualified personnel should install and service the UACD system and
modules. Hazardous energy and voltages are present in the unit and on the
interface cables and will shock or cause serious injury or death if safety
precautions are ignored. Follow all safetywarnings and practices when servicing
this equipment.
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 179
7_Netzanschluss.fm
Connecting to the Mains and Power Supply
UACD (Lineage Power) 19-Inch Installation
HDR 3
HDR 2
A31003-H3170-J100-2-7631, 05/2015
180 OpenScape 4000 V7, Installation Instructions
7_Netzanschluss.fm
Connecting to the Mains and Power Supply
UACD (Lineage Power) 19-Inch Installation
1. Install DC reference and frame ground cable (see also Figure 41):
NOTE:
DC reference and frame ground cables are not included. Some installations may
not require separate reference and frame ground wires.
a) Step 1:
Remove the 6 screws and rear access cover see Figure 40.
6 screws
b) Step 2:
Will separate dc reference and frame grounds be used?
If Yes, then use a # 10 AWG (user provided) cable, strip the insulation and
install one M4 single hole lug and one M8 single hole lug to form a cable.
Install the ground cable from the dc reference point to the frame point
shown below.
If no, then go on with c).
c) Step 3:
Use a # 10 AWG (user provided) cable, strip the insulation and use one
3/8” single-hole lug to form a ground cable. Install the lugged cable from
the M8 frame ground connection to the appropriate building ground point.
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 181
7_Netzanschluss.fm
Connecting to the Mains and Power Supply
UACD (Lineage Power) 19-Inch Installation
7 WARNING
Risk of electric shock through contact live wires
Verify all circuit breakers are in the open position before proceeding.
1. Remove the shelf to shelf bus bar knockout (see Figure 43).
A31003-H3170-J100-2-7631, 05/2015
182 OpenScape 4000 V7, Installation Instructions
7_Netzanschluss.fm
Connecting to the Mains and Power Supply
UACD (Lineage Power) 19-Inch Installation
3. Align the bus bars through the opening (see Figure 44).
4. Install the battery bus bars and secure with hardware (screws, see Figure 44)
previously removed. Torque hardware to 60 – inch lbs (see Figure 43 and
Figure 44).
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 183
7_Netzanschluss.fm
Connecting to the Mains and Power Supply
UACD (Lineage Power) 19-Inch Installation
A31003-H3170-J100-2-7631, 05/2015
184 OpenScape 4000 V7, Installation Instructions
7_Netzanschluss.fm
Connecting to the Mains and Power Supply
UACD (Lineage Power) 19-Inch Installation
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 185
7_Netzanschluss.fm
Connecting to the Mains and Power Supply
UACD (Lineage Power) 19-Inch Installation
1. Step1:
Cut the tie wrap and uncoil the shelf to shelf communication cable. Route the
cable through the round hole to the second shelf.
2. Step 2:
Plug the opposite end of the cable into the HDR3 connector of the second
shelf.
A31003-H3170-J100-2-7631, 05/2015
186 OpenScape 4000 V7, Installation Instructions
7_Netzanschluss.fm
Connecting to the Mains and Power Supply
UACD (Lineage Power) 19-Inch Installation
There are four 40 Amp load circuit breakers located on the front of each shelf.
Load wiring connects on the rear of the shelf. Up to a 8 AWG wire can be termi-
nated.
1. Step 1:
Strip insulation from wires, insert wires into terminals. Torque connection to
20 – inch lbs. Repeat for each load circuit.
2. Step 2:
Dress and strain relieve wires in a downward direction and route the wires
throug the outlett on backside (see Figure 49).
+ -48V
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 187
7_Netzanschluss.fm
Connecting to the Mains and Power Supply
UACD (Lineage Power) 19-Inch Installation
Remove
NOTE: To ensure a correct shielding contact of load cables to the housing, you
have to strip and fix the cable with 2 cable ties as shown in the Figure 48.
A31003-H3170-J100-2-7631, 05/2015
188 OpenScape 4000 V7, Installation Instructions
7_Netzanschluss.fm
Connecting to the Mains and Power Supply
UACD (Lineage Power) 19-Inch Installation
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 189
7_Netzanschluss.fm
Connecting to the Mains and Power Supply
UACD (Lineage Power) 19-Inch Installation
1. Step 1:
Install the temperature probe on the battery post as shown in the Figure 50.
Temperature probe
2. Step 2:
Locate J4 on the rear of the shelf and plug-in the RJ45 connector (see Figure
51). Route the cable to the temperature probe and plug it into the connector
(see Figure 52).
A31003-H3170-J100-2-7631, 05/2015
190 OpenScape 4000 V7, Installation Instructions
7_Netzanschluss.fm
Connecting to the Mains and Power Supply
UACD (Lineage Power) 19-Inch Installation
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 191
7_Netzanschluss.fm
Connecting to the Mains and Power Supply
UACD (Lineage Power) 19-Inch Installation
from Shelf A
from Shelf B
3. Step 3:
Secure the temperature probe cover to the probe (see Figure 52).
4. Step 4:
In case of an secondary shelf B secure the temperatur probe additionally
beside the temperature probe of the primary shelf A (see Figure 52 and
Figure 53).
A31003-H3170-J100-2-7631, 05/2015
192 OpenScape 4000 V7, Installation Instructions
7_Netzanschluss.fm
Connecting to the Mains and Power Supply
UACD (Lineage Power) 19-Inch Installation
PIN Description
1 Door Open Alarm
2 Auxiliary Major Alarm
3 VBUS – (PTC protected)
4 Power Major Alarm Return
5 Power Minor Alarm Return
6 Battery On Discharge Alarm
Return
7 Rectifier Fail Alarm Return
8 AC Fail Alarm
9 SPD Fail (Surge Protection Fail)
10 Air Conditioner Fail
11 Unassigned
12 Power Major Alarm
13 Power Minor Alarm
14 Battery On Discharge Alarm
15 Rectifier Fail Alarm
16 AC Fail Alarm
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 193
7_Netzanschluss.fm
Connecting to the Mains and Power Supply
UACD (Lineage Power) 19-Inch Installation
A31003-H3170-J100-2-7631, 05/2015
194 OpenScape 4000 V7, Installation Instructions
7_Netzanschluss.fm
Connecting to the Mains and Power Supply
UACD (Lineage Power) 19-Inch Installation
Rack 1
Rack 2
Rack 1
Rack 2
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 195
7_Netzanschluss.fm
Connecting to the Mains and Power Supply
UACD (Lineage Power) 19-Inch Installation
Stack 1
Stack 2
Stack 1
Stack 2
A31003-H3170-J100-2-7631, 05/2015
196 OpenScape 4000 V7, Installation Instructions
7_Netzanschluss.fm
Connecting to the Mains and Power Supply
UACD (Lineage Power) 19-Inch Installation
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 197
7_Netzanschluss.fm
Connecting to the Mains and Power Supply
UACD (Lineage Power) 19-Inch Installation
AC input options
Single phase (factory default); L1, L2, L3 jumpered and N1, N2, N3 jumpered.
Typical 3 wire input; phase to neutral with PE ground. Three rectifiers are fed
from one input.
Figure 56 AC input option 1 (Singel phase)
Dual phase (factory default); L1, L2, L3 jumpered and N1, N2, N3 jumpered.
A31003-H3170-J100-2-7631, 05/2015
198 OpenScape 4000 V7, Installation Instructions
7_Netzanschluss.fm
Connecting to the Mains and Power Supply
UACD (Lineage Power) 19-Inch Installation
Typical 3
wire input; phase to neutral with PE ground. Three rectifiers are fed from one
Figure 57 AC input option 1 (Dual phase)
Three phase star connection; L1, L2, L3 individual feeds. N1, N2, N3 jumpered.
Typical 5 wire input; 3 phase inputs (L1, L2, L3), one neutral and one PE
ground. Three rectifiers are fed from three phases with one neutral feed.
Figure 58 AC input option 2 (Three phase star connection)
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 199
7_Netzanschluss.fm
Connecting to the Mains and Power Supply
UACD (Lineage Power) 19-Inch Installation
Typical 7 wire input;3 phase inputs (L1, L2, L3) and 3 neutral inputs (N1, N2,
N3) and one PE ground. Three rectifiers are individually fed from three circuits.
Figure 59 AC input option 2 (Three phase star connection)
a) Step 1:
Remove the 6 screws and cover from the rear of the shelf (seeFigure 40 ).
b) Step 2:
Route the ac wires through the shelf grommet (1). Bundle the wires
together and secure the bundle with a zip tie behind the grommet. Use a
second zip tie to strain relieve the bundle to the shelf tie point (2).
2 1
3
Figure 60 Routing AC wires
A31003-H3170-J100-2-7631, 05/2015
200 OpenScape 4000 V7, Installation Instructions
7_Netzanschluss.fm
Connecting to the Mains and Power Supply
UACD (Lineage Power) 19-Inch Installation
c) Step 3:
Secure the Ground (PE) wire (green-yellow), see (3) on Figure 60. Torque
to 20 – lbs.
d) Step 4:
Strip insulation from the ac input wires, insert and secure wires to the
terminal blocks, see (3) on Figure 60. Torque terminal screws to 20 in –
lbs.
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 201
7_Netzanschluss.fm
Connecting to the Mains and Power Supply
UACD (Lineage Power) 19-Inch Installation
NOTE: Verify correct battery cable polarity before landing battery cables.
a) Step 1:
Remove the M8 bolts and connect battery cables to the battery bus bars
as shown in Figure 61. Torque connections to 60 - inch lbs.
b) Step 2:
Dress and strain relieve battery cables in a downward direction and route
the wires through the outlet on backside (see Figure 49).
-48V Battery
+ Battery
-48V Battery
+ Battery
A31003-H3170-J100-2-7631, 05/2015
202 OpenScape 4000 V7, Installation Instructions
7_Netzanschluss.fm
Connecting to the Mains and Power Supply
UACD (PSR930/PSR930E) 19-Inch Installation
IMPORTANT:
- The UACD power box (PSR930/PSR930E) may only be installed in a separate,
closed 19" cabinet. This cabinet must ensure mechanical and electrical
protection and may only be serviced by authorized service personnel.
- All PSR930 lines (in the 19" cabinet) must be secured with an appropriate cord
grip (e.g. cable tie).
- System- Batt.
Figure 62 UACD base cabinet PSR930 (front view)
The UACD expansion cabinet PSR930E has the same structure as the base
cabinet minus the base controller.
IMPORTANT:
- Before starting up the power, ensure that all network modules on the front are
securely screwed into the shelf to guarantee a secure contact.
- If you need to replace a network moduleor change the number of network
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 203
7_Netzanschluss.fm
Connecting to the Mains and Power Supply
UACD (PSR930/PSR930E) 19-Inch Installation
modules,you must hold down the "System configuration" button for at least 3s on
the controller (seeFigure 62) after the replacement/expansiob to ensure that the
new network module can be reassigned to the alarm system.
To connect the power supply cables to an UACD, you must first remove the rear
covers.
A31003-H3170-J100-2-7631, 05/2015
204 OpenScape 4000 V7, Installation Instructions
7_Netzanschluss.fm
Connecting to the Mains and Power Supply
UACD (PSR930/PSR930E) 19-Inch Installation
IMPORTANT: The base and expansion cabinets are physically connected left
and right at the rear by a metal bracket (indicated in green in Figure 64) (see also
the Service Manual).
1
- 2
+
Output terminals
Output terminals
+/- 48V to the
+/- 48V to the battery system
Input terminals
~230/380V from the
network
-
+/- 48V connection
+
If a base and expansion cabinet are used, the +/-48V are connected as
shown in this image.
Figure 64 UACD power box PSR930/PSR930E (back view)
To establish communication with the expansion cabinet, first connect the base
cabinet’s relevant bus cable (1) to the expansion cabinet. Then plug the base
cabinet’s contactor control monitoring cable (2) into the expansion cabinet (see
also the Service Manual).
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 205
7_Netzanschluss.fm
Connecting to the Mains and Power Supply
UACD (PSR930/PSR930E) 19-Inch Installation
A31003-H3170-J100-2-7631, 05/2015
206 OpenScape 4000 V7, Installation Instructions
7_Netzanschluss.fm
Connecting to the Mains and Power Supply
UACD (PSR930/PSR930E) 19-Inch Installation
Rack 1 Rack 2
AP AP
UACD AP AP
# 4)
230/ PSR930
400V~ -
MDF .. 4 3 21 Outg. - - - -
+ fuse + DCDR + + DCDR +
~ AP AP
§)
&) Battery
- &) PE cross-section min. 10mm2 , AWG
+
6 (AWG = American Wire Gage)
§) PE line is connected
Ground busbar
#) AC terminals
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 207
7_Netzanschluss.fm
Connecting to the Mains and Power Supply
UACD (PSR930/PSR930E) 19-Inch Installation
Stack 1 Stack 4
*-X12 *-X11 *-X12 *-X11
UPR UPR
PS LTUW PS PS LTUW PS
UP UP UP UP
Talk Talk
Bulk Bulk
A31003-H3170-J100-2-7631, 05/2015
208 OpenScape 4000 V7, Installation Instructions
7_Netzanschluss.fm
Connecting to the Mains and Power Supply
UACD (PSR930/PSR930E) 19-Inch Installation
With a three-phase network, the 3 neutral wires are connected with a contact
jumper (1). Connect the corresponding power line as illustrated below.
Figure 67 shows the mains connection to the UACD for a three-phase network.
Overload protection:
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 209
7_Netzanschluss.fm
Connecting to the Mains and Power Supply
UACD (PSR930/PSR930E) 19-Inch Installation
The jumper (1) - if still installed - must be removed for a single-phase connection.
Connect the corresponding power line as illustrated below.
Figure 68 shows the mains connection to the UACD for a one-phase network.
Overload protection:
The jumper (1) - if still installed - must be removed for a two-phase connection.
Connect the corresponding power line as illustrated below.
Figure 69 shows the mains connection to the UACD for a two-phase network.
Overload protection:
A31003-H3170-J100-2-7631, 05/2015
210 OpenScape 4000 V7, Installation Instructions
7_Netzanschluss.fm
Connecting to the Mains and Power Supply
UACD (PSR930/PSR930E) 19-Inch Installation
The jumper (1) - if still installed - must be removed for a mains delta connection.
Connect the corresponding power line as illustrated below.
Figure 70 shows the mains connection to the UACD for a mains delta connection.
Overload protection:
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 211
7_Netzanschluss.fm
Connecting to the Mains and Power Supply
UACD (with BAMX1 and BAMX2) 30-Inch Installation
X
M
EBCCB
BA
Stack 1,2,/3.4
PDPX2
ACDPX
LPC
LPC
LPC
A31003-H3170-J100-2-7631, 05/2015
212 OpenScape 4000 V7, Installation Instructions
7_Netzanschluss.fm
Connecting to the Mains and Power Supply
UACD (with BAMX1 and BAMX2) 30-Inch Installation
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 213
7_Netzanschluss.fm
Connecting to the Mains and Power Supply
UACD (with BAMX1 and BAMX2) 30-Inch Installation
Bulk
FCS
NGA1 40 A 40 A 2
NGA2 to Stack
40 A 40 A 1
1-2
Talk
NGA3
40 A 2
- 48V
70 A
POW.
NGA SHARE
BATT. PDPX2
IN
1)
X2 BAEX X8
+
-
X7 X6 X1 X3 X9
BATT. BAMX1
INPUT
BAEXF
NGAR
NGA1
NGA2
NGA3
NGA
WRA
- 48V sense
PFI
- 48V sense
70 A 14 A
UACD 2
X8 -> contactor control output CAB1
Battery
X9 -> contactor control output CAB2
1) -> contactor control input
Figure 73 UACD 1 connections
A31003-H3170-J100-2-7631, 05/2015
214 OpenScape 4000 V7, Installation Instructions
7_Netzanschluss.fm
Connecting to the Mains and Power Supply
UACD (with BAMX1 and BAMX2) 30-Inch Installation
1 40 A 40 A
Bulk
FCS
2 40 A 40 A
to Stack
3-4 1 Talk 40 A 40 A
40 A
- 48V
2
70 A
POW. NGA
SHARE PDPX2 BATT.
IN
NGA3
NGA2
NGA1
+
-
BAMX2 BATT.
INPUT
1)
14 A 70 A
EBCCB
BAMX1
X9 BAEX X3
to BAEX UACD 1
UACD 1
Battery X9 -> contactor control output CAB2
1) -> contactor control input
Figure 74 UACD 2 connections
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 215
7_Netzanschluss.fm
Connecting to the Mains and Power Supply
Battery Manager Cabinet for L80XF Shelf
EBCCB
X2
X1
EBCCB
M
M
BA
BA
Stack 3,4
PDPX2
Stack 1,2
PDPX2
ACDPX
LPC
LPC
Figure 75 Battery Manager cabinet for L80XF shelf
A31003-H3170-J100-2-7631, 05/2015
216 OpenScape 4000 V7, Installation Instructions
7_Netzanschluss.fm
Connecting to the Mains and Power Supply
Battery Manager Cabinet for L80XF Shelf
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 217
7_Netzanschluss.fm
Connecting to the Mains and Power Supply
Battery Manager Cabinet for L80XF Shelf
Line Line
l N PE LPC power supply l N PE
40 A 1 40 A 1
Bulk
NGA1
Bulk
40 A 2 to 40 A 2 to
LPC1 LPC1
NGA1 40 A 40 A 1 stack 40 A 1 stack
3-4
Talk
1-2
Talk
40 A
40 A 2 40 A 2
- 48V
- 48V
70 A 70 A
NGA POW. NGA
BATT. PDPX2 PDPX2 POW.
SHARE BATT. SHARE
IN IN
1)
NGA
BAMX1 BAMX2
X2 BAEX X8 -
+
-
+
X7 X6 X1 X3 X9
BATT.
NGA BATT. INPUT
BAEXF
NGAR
- 48V sense
- 48V sense
NGA
WRA
PFI
INPUT
1)
14 A 70 A 14 A 70 A
CCDAX-BGR
ALIN cable
EBCCB EBCCB
A31003-H3170-J100-2-7631, 05/2015
218 OpenScape 4000 V7, Installation Instructions
7_Netzanschluss.fm
Connecting to the Mains and Power Supply
UDCD (Zytron), North America Only
Stack 1,2/3,4
ICBP
Zytron
Zytron
Zytron
ODP
BUA
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 219
7_Netzanschluss.fm
Connecting to the Mains and Power Supply
UDCD (Zytron), North America Only
(+) COM.
EMI filter MODE –48 Vdc
(-) CHOKE
CB RET
100 Protective
- + - + ground
BUA
J2 J1
J7 J6 J5 ODP
E3 DCPFX
J2 J1
40 A J17 Bulk to
stack(2)
J16 RTN
J7 J6 J5
E4 ODP
DCPFX E3 to CSPCI or
stack 2
DCPFX E4
Figure 78 Overview of UDCD Stack 1 Connections
A31003-H3170-J100-2-7631, 05/2015
220 OpenScape 4000 V7, Installation Instructions
7_Netzanschluss.fm
Connecting to the Mains and Power Supply
UDCD (Lineage Power)
NOTE: The initial installation for the UDCD and their documentation will be
covered by local company in US.
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 221
7_Netzanschluss.fm
Connecting to the Mains and Power Supply
Connecting the Power Box to the System
1. Attach the cable from connector X1 in the BAMX1 (BAEX) to the ALIN
connector in the CSPCI box (stack 1).
2. From PDPX2 (1), stack 1/2, and PDPX2 (2), stack 3/4, connect one –48-V
TALK and one –48-V BULK cable to the relevant –48-V connectors on the
lower shelves at the back of each stack. Table 13 and Figure 80 show how to
connect the bulk and talk cables from the BAMX to the OpenScape 4000
cabinets.
Back
Stack 4 Stack 3 Stack 2 Stack 1
Power
LTU.. 15 LTU.. 11 LTU.. 7 LTU.. 3
box
LTU.. 14 LTU.. 10 LTU.. 6 LTU.. 2
A31003-H3170-J100-2-7631, 05/2015
222 OpenScape 4000 V7, Installation Instructions
7_Netzanschluss.fm
Connecting to the Mains and Power Supply
Connecting the Power Box to the System
The –48 V connectors from the MDFs can be combined as required. Ensure that
the number of MDFs connected at a fuse does not exceed the overall power
requirement for each 1.6 A fuse.
Stack 1
LTU.. 3
LTU.. 2
LTU.. 1
-48 V
TALK
PDPX2(1) -48 V MDF
Figure 81 Redundant -48-V connection unit for MDF
The main distribution frame connection of –48 V is the same as that described in
the Section 7.13.2, "Connecting the MDF for a Nonredundant, System, I.M.".
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 223
7_Netzanschluss.fm
Connecting to the Mains and Power Supply
PSDXE Connection
Battery IN
UBATT EBCCB
NGA
BAMX1 PDPX2
Figure 82 PSDXE connection
A31003-H3170-J100-2-7631, 05/2015
224 OpenScape 4000 V7, Installation Instructions
7_Netzanschluss.fm
Connecting to the Mains and Power Supply
Calculating the Battery Cabling, I.M.
• Minimum system voltage 42.5 V at the BAEX module (in the BAMX1 in
CABPSD)
• Permissible voltage drop (Uv) on the battery cable, from the terminal to the
battery, if the battery is to be discharged to 44V (1.83V/battery)
• The system current is based on the power supply units output as follows:
NOTE: If possible, the battery cable cross-section should not be less than 70
mm2, even in configurations with fewer than 6 PSUs. A cross-section of at least
70 mm2 if the configuration is subsequently expanded to the maximum of 6 PSUs
in order to ensure proofing against short-circuits. Expansions should always
provide for a certain reserve, as otherwise, the battery cable must be reinforced
or replaced if the voltage drop (Uv) is exceeded at 1.5 V.
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 225
7_Netzanschluss.fm
Connecting to the Mains and Power Supply
Calculating the Battery Cabling, I.M.
A31003-H3170-J100-2-7631, 05/2015
226 OpenScape 4000 V7, Installation Instructions
8_InterneLeitungen.fm
Internal Line Cables
Installing Signal Cables
NOTE: To avoid a short-circuit, ensure that the power on the system is off before
connecting and removing the LTU cables.
The following default cable lengths are used depending on the installation
variant:
• 2 m (in stack 1)
Duplex LTU.. 1 - LTU.. 15 (LTUCA board CCA) CSPCI RTM (EBT 2/3)
LTU.. 1 - LTU.. 15 (LTUCA board CCB) CSPCI RTM(EBT 5/6)
The cables for trunk failure transfer, reference clock and alarm signaling are
connected to the MCM board.
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 227
8_InterneLeitungen.fm
Internal Line Cables
Installing Signal Cables
Simplex
LTUCA
LTU/
AP 3700 Duplex
WHB
WHA
CCB
CCA
RUN FAIL
ALUM
2. All cables that lead to the main distribution frames (I.M.) must be attached to
the relevant stack frames with cable fasteners (see Figure 4).
A31003-H3170-J100-2-7631, 05/2015
228 OpenScape 4000 V7, Installation Instructions
8_InterneLeitungen.fm
Internal Line Cables
Installing Signal Cables
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 229
8_InterneLeitungen.fm
Internal Line Cables
Installing Signal Cables
C39195- 20 20 20 50 50 50 50 50 50 50 50 50 50 50 50
Z7211-A...
L80XF/ 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
LTUW/
AP3700
Front CCA CCA CCA CCA CCA CCA CCA CCA CCA CCA CCA CCA CCA CCA CCA
LTUCA board
CSPCI
Cab. LTU LTU LTU LTU LTU LTU LTU LTU LTU LTU LTU LTU LTU LTU LTU
connector 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
SLOT, rear
1. RTM, mono R1/2 R1/2 R1/2 R1/2 R1/2 R1/2 R1/2 R1/2 R1/2 R1/2 R1/2 R1/2 R1/2 R1/2 R1/2
or or or or or or or or or or or or or or or or
1. RTM, duplex R2/3 R2/3 R2/3 R2/3 R2/3 R2/3 R2/3 R2/3 R2/3 R2/3 R2/3 R2/3 R2/3 R2/3 R2/3
2. RTM, duplex R5/6 R5/6 R5/6 R5/6 R5/6 R5/6 R5/6 R5/6 R5/6 R5/6 R5/6 R5/6 R5/6 R5/6 R5/6
Cab. LTU LTU LTU LTU LTU LTU LTU LTU LTU LTU LTU LTU LTU LTU LTU
connector 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
CSPCI
Front CCB CCB CCB CCB CCB CCB CCB CCB CCB CCB CCB CCB CCB CCB CCB
LTUCA board
L80XF/ 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
LTUW/
AP3700
A31003-H3170-J100-2-7631, 05/2015
230 OpenScape 4000 V7, Installation Instructions
8_InterneLeitungen.fm
Internal Line Cables
Installing Signal Cables
C39195- 20 20 20 50 50 50 50 50 50 50 50 50 50 50 50
Z7211-A...
L80XF/ 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
LTUW/
AP3700
Front CCA CCA CCA CCA CCA CCA CCA CCA CCA CCA CCA CCA CCA CCA CCA
LTUCA board
EcoServer 1
Cab. LTU LTU LTU LTU LTU LTU LTU LTU LTU LTU LTU LTU LTU LTU LTU
connector 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
1 x RTMx
(mono)
or ------------- ------ ------ ------ ------ ------ ------ ------ ------ ------ ------ ------ ------ ------ ------ ------
2 x RTMx,
duplex
Cab. LTU LTU LTU LTU LTU LTU LTU LTU LTU LTU LTU LTU LTU LTU LTU
connector 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
EcoServer 2
Front CCB CCB CCB CCB CCB CCB CCB CCB CCB CCB CCB CCB CCB CCB CCB
LTUCA board
L80XF/ 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
LTUW/
AP3700
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 231
8_InterneLeitungen.fm
Internal Line Cables
Installing Signal Cables
Ext. I/F Service Mainte- Host LTUCA/ Mainte- Ext. UACD MDF
PC nance Slots LTUCR nance Clock Box IM / US
Periph. Box
Front
Front
Front
Front
Rear
Rear
Rear
Rear
Rear
CSPCI SLOT 1/2/5
> -----DSCXL2----- RTM ----MCM----
Board
KAST name 8 x LAN 1 x 1 x V.24 2 x 15xLAN 1) 1 x V.24 ref.clock ALIN ASW
8-8pos USB DSUB-9 USB 8-8pos DSUB-9 25-25pos 10-10pos DSUB
slave VGA 2.0 VGA -open
C39195-Z7211- 7...120 20...100
A..
C39195-Z7702- 20
A20
S30267-Z355- 25
A..
C39195-Z7615/ 30/100
7602-A..
Standard X
commercial USB
cable
C39195-Z7612- 100...
A..3) 950 (IM)
C39195-Z7613- Patch
A.. panel
(IM)
50 / 150
C39195-Z7614- 100/
A..4) 150 (US)
External cable X
S30122-X8011- 25
X10
A31003-H3170-J100-2-7631, 05/2015
232 OpenScape 4000 V7, Installation Instructions
8_InterneLeitungen.fm
Internal Line Cables
Installing Signal Cables
8.1.4.1 Front
Front
Front
Front
EcoServer
KAST name 1 x USB 4 x USB HDMI
slave USB 2-5
C39195-Z7702- 20
A20
Standard X
commercial
USB cable
C39195-Z7617- 20
A1
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 233
8_InterneLeitungen.fm
Internal Line Cables
Installing Signal Cables
8.1.4.2 Back
for RTMx LTUCA/ External UACD MDF Main board Remote I/F
duplex LTUCR clock box Box IM / US ext. I/F
config. Periph.
Rear
Rear
Rear
Rear
Rear
Rear
Rear
EcoServer --------RTMx-------
1)
KAST name Cross- 15 x LAN Ref.clock ALIN ALUM 8 x LAN 1 x LAN
connect 8-8pos SUB-D 25 SUB-D 9 SUB-D 15 8-8pos. 1-Gbit
SCSI2 25-25pos. -open 1-Gbit
50-50pos.
C39195-Z7211- 20...100 7...120
A..
C39195-Z7612- 100...
A.. 950 (IM)
C39195-Z7613- Patch
A... panel
(IM)
50 / 150
C39195-Z7614- 100/
A.. 150 (US)
External cable X
C39195-Z7409- 130mm
A1
S30122-X8011- 50
X12
C39195-Z7702- 20
A20
1) 15 LAN cable for LTU1...LTU15 (AP3700 --> 1 ... 15), see also label on
EcoServer rear side (15 x Lan, cable lengths: 2m, 5m, 10m).
7 CAUTION
The cross-connect cable must not be unplugged or plugged into the active
server when the system is online, unless the server is in standalone mode.
A31003-H3170-J100-2-7631, 05/2015
234 OpenScape 4000 V7, Installation Instructions
8_InterneLeitungen.fm
Internal Line Cables
Installing Signal Cables
To avoid malfunctions when inserting the cross-connect cable, connect the cable
– depending on the application – in the sequence described below:
3. Remove the cross-connect cable on the defective server only (do not
remove the cross-connect cable from the active server as this would trigger a
restart of the active server).
5. Connect the cross-connect cable, which is still plugged into the active
server, to the second EcoServer.
6. Connect the power cable to the second EcoServer and switch on the power
supply.
2. Switch the active server to standalone mode (see "Separated Duplex": stand-
alone_operation enable).
3. You can now also remove the cross-connect cable from the standalone
server.
4. Now connect the new cross-connect cable to the two EcoServers, starting
with the active server.
Starting situations
1. Operation of the first system with connected cross-connect cable
b) Connect the power cable to the second EcoServer and switch on this
server.
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 235
8_InterneLeitungen.fm
Internal Line Cables
Installing the Service Alarm Cable and Trunk Bypass
The active server in standalone mode detects the second EcoServer by means
of the cross-connect cable and automatically switches from standalone mode to
duplex mode.
The connectors for the alarm interface and trunk failure transfer are located on
the rear of the EcoServer.
2. Connect the open end cable to the MDF (or the cable (S30267-Z7613-A*) to
the patch panel).
3. Connect the cable (S30122-X8011-X10) for the alarm interface to the ALIN
connector on the CSPCI or the cable (S30122-X8011-X12) to the ALIN
connector on the EcoServer and connect the other end of the cable to the
ALIN connector on the UACD box.
A31003-H3170-J100-2-7631, 05/2015
236 OpenScape 4000 V7, Installation Instructions
9_ExterneKabelbaugruppen.fm
External Cabling Assemblies
This section describes the assembly of the main distribution frames and the
cables that must be connected from the MDF splitting strips to the corresponding
LTU/AP 3700 slots in the OpenScape 4000 (also refer to the cable plugging list
that accompanies the relevant system). Two different MDFs can be used
(MDFHX6) depending on the system configuration.
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 237
9_ExterneKabelbaugruppen.fm
External Cabling Assemblies
MDFHX6 Assembly, I.M.
A01:
Carrier for special modules
(ALUM relay, automatic B
cutout etc.)
B/F: C
Plate (attachment for internal
and external ground cable)
C01-C16:
24 DA splitting strips
A
(internal connections for
system LTUE network)
D001-D19:
35 DA strapping
connectors (external
connections for server, AC,
line and CO network)
D
A31003-H3170-J100-2-7631, 05/2015
238 OpenScape 4000 V7, Installation Instructions
9_ExterneKabelbaugruppen.fm
External Cabling Assemblies
MDFHX6 Assembly, I.M.
LTU.. 2
MDF 2 Back view
SLOT 121
SLOT 108
SLOT 103
SLOT 097
SLOT 091
SLOT 085
SLOT 079
SLOT 067
SLOT 061
SLOT 055
SLOT 049
SLOT 043
SLOT 037
SLOT 031
SLOT 025
SLOT 115
16 09 08 01
LTU.. 1
MDF 1
Back view
1 per 24 pair a/b 24
MDF splitting strip 16
1 24
MDF splitting strip 01
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 239
9_ExterneKabelbaugruppen.fm
External Cabling Assemblies
MDFHX6 Assembly, I.M.
MDF 1 13 09 08 01
1 24
MDF splitting strip 01
A31003-H3170-J100-2-7631, 05/2015
240 OpenScape 4000 V7, Installation Instructions
9_ExterneKabelbaugruppen.fm
External Cabling Assemblies
Overvoltage Protection of the Modules, I.M.
NOTE:
Lightning protection on the boards:
Analog and digital subscriber lines are protected on the boards using protection
up to 2KV longitudinal voltage and 1KV transverse voltage against high-energy
overvoltage in pulses from 10/700us and 1.2/50us, which can be induced by a
lightning strike. This protection is only effective, however, if the system is
grounded correctly in accordance with the assembly guidelines.
Grounding:
Once OpenScape 4000 has been grounded, check the low-impedance grounding
of the system via the ground connector of the power supply circuit as well as the
low-impedance connection of the additional permanently connected protective
grounding conductor to the building's equipotential busbars.
NOTE:
External lightning protection:
With line lengths of over 500m and if the lines leave the building, analog and
digital subscriber boards must be protected by external lightning protection.
Overvoltage protection is integrated in the module for 24DA cables. The cable
connectors do not contain any other overvoltage protection devices.
Where necessary, you can use overvoltage protectors to protect external cables
to the main distribution frame against atmospheric pressure.
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 241
9_ExterneKabelbaugruppen.fm
External Cabling Assemblies
Overvoltage Protection of the Modules, I.M.
SWU MDF
PE cable acc. to
DIN EN 50310
A31003-H3170-J100-2-7631, 05/2015
242 OpenScape 4000 V7, Installation Instructions
9_ExterneKabelbaugruppen.fm
External Cabling Assemblies
MDF Cable Connections, I.M.
IMPORTANT: PIN assignment is different on the LTUW backplane and the cable
connectors!
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 243
9_ExterneKabelbaugruppen.fm
External Cabling Assemblies
Connecting the Signal or Alarm Cables to the MDF, I.M.
– ALUM on: System had a problem, e.g. reload (ALUM contact is open)
These signals are transmitted via relays to the front connector (15-pin), which is
connected in turn to the main distribution frame via the cable C39195-Z7612-A*
(DSub connector, open end).
11 = ALUM 1
06 = ALUM 2
02 = NAL 1
03 = NAL 2
10 = UAL 1
05 = UAL 2
A31003-H3170-J100-2-7631, 05/2015
244 OpenScape 4000 V7, Installation Instructions
9_ExterneKabelbaugruppen.fm
External Cabling Assemblies
Connecting Subscriber Line Modules/Trunk Boards
Splitting MDF
strip 16 cable
1. -Wire pair-8. 9.-Wire pair-16. 17.-Wire pair-24.
1
Splitting
strip 1
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 245
9_ExterneKabelbaugruppen.fm
External Cabling Assemblies
Connecting Subscriber Line Modules/Trunk Boards
A31003-H3170-J100-2-7631, 05/2015
246 OpenScape 4000 V7, Installation Instructions
9_ExterneKabelbaugruppen.fm
External Cabling Assemblies
Connecting Subscriber Line Modules/Trunk Boards
Table 4 lists the line connections for the subscriber line modules.
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 247
9_ExterneKabelbaugruppen.fm
External Cabling Assemblies
Connecting Subscriber Line Modules/Trunk Boards
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
--- --- --- --- --- --- --- --- ---
--- --- --- --- --- --- ---
a a a a a a a a a a a a a a a a
b b b b b b b b b b b b b b b b
Table 4 Subscriber line module connections (Seite 2 von 3)
A31003-H3170-J100-2-7631, 05/2015
248 OpenScape 4000 V7, Installation Instructions
9_ExterneKabelbaugruppen.fm
External Cabling Assemblies
Connecting Subscriber Line Modules/Trunk Boards
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 249
9_ExterneKabelbaugruppen.fm
External Cabling Assemblies
Connecting Subscriber Line Modules/Trunk Boards
A31003-H3170-J100-2-7631, 05/2015
250 OpenScape 4000 V7, Installation Instructions
9_ExterneKabelbaugruppen.fm
External Cabling Assemblies
Connecting Subscriber Line Modules/Trunk Boards
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 251
9_ExterneKabelbaugruppen.fm
External Cabling Assemblies
Connecting Subscriber Line Modules/Trunk Boards
1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 -
--- --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- ---------------
AE AE AE AE AM AM AM AM E E E E MA MA MA MA <--
BE BE BE BE BM BM BM BM M M M M MB MB MB MB Standard
--- --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- ---------------
T T T T T1 T1 T1 T1 E E E E - - - - <--
R R R R R1 R1 R1 R1 M M M M - - - - Type I
--- --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- ---------------
Fan Fan Fan Fan Fab Fab Fab Fab - - - - - - - - <--
A A A A A A A A San SanSanSan - - - - Type Ia
B B B B B B B B Sab SabSabSab - - - - -
--- --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- ---------------
T T T T T1 T1 T1 T1 E E E E M M M M <--
R R R R R1 R1 R1 R1 SG SG SG SG SB SB SB SB Type II
Table 6 Connection to MDF (Seite 1 von 3)
A31003-H3170-J100-2-7631, 05/2015
252 OpenScape 4000 V7, Installation Instructions
9_ExterneKabelbaugruppen.fm
External Cabling Assemblies
Connecting Subscriber Line Modules/Trunk Boards
1 - 2 -
--- --- --- ---
a a
b b
TMOM2 a/b > 17 mA APSE QUAD-SICOFI 4 3
-Q2214- 051XH DT X max. 2 x 500 / 1000 (adapter for special
MF Ohm equipment)
X100 (depending on Paging equipment, dictation
partner) equipment, TERM, ELA,
c-wire max. NWS, announcement
200Ohm equipment, QU, and
(with 3-wire outgoing loop monitoring
connection)
-0/-7 dBr
1 3 2 4 1 1 2 2 3 3 4 4
--- --- --- --- --- --- --- --- --- --- --- ---
a a a a J D J D J D J D
b b b b P C P C P C P C
Table 6 Connection to MDF (Seite 2 von 3)
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 253
9_ExterneKabelbaugruppen.fm
External Cabling Assemblies
Connecting Subscriber Line Modules/Trunk Boards
1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8
--- --- --- --- --- --- --- --- --- --- --- --- --- --- --- ---
Fan Fab Fan Fab Fan Fab Fan Fab Fan Fab Fan Fab Fan Fab Fan Fab
AE AM AE AM AE AM AE AM AE AM AE AM AE AM AE AM
BE BM BE BM BE BM BE BM BE BM BE BM BE BM BE BM
0 0 1 1 2 2 3 3 4 4 5 5 6 6 7 7
Table 6 Connection to MDF (Seite 3 von 3)
A31003-H3170-J100-2-7631, 05/2015
254 OpenScape 4000 V7, Installation Instructions
9_ExterneKabelbaugruppen.fm
External Cabling Assemblies
Connecting Subscriber Line Modules/Trunk Boards
Table 9-3 lists the trunk connections to the MDF with DID.
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 255
9_ExterneKabelbaugruppen.fm
External Cabling Assemblies
Connecting Subscriber Line Modules/Trunk Boards
Table 7 lists the trunk connections to the MDF with CDR and DID.
A31003-H3170-J100-2-7631, 05/2015
256 OpenScape 4000 V7, Installation Instructions
9_ExterneKabelbaugruppen.fm
External Cabling Assemblies
Connecting Subscriber Line Modules/Trunk Boards
Table 8 lists the trunk connections to the MDF with CDR but without DID.
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 257
9_ExterneKabelbaugruppen.fm
External Cabling Assemblies
Creating a Strapping List, I.M.
1. Use the tables in Section 9.6.1, “System Assignment 16/24 DA Splitting Strip”
and Section 9.6.2, “Network Assignment 25/35 DA Strapping Connector” as
templates to strapping the MDF.
You can also query the assignment of positions with the AMOs SBCSU and
SCSU.
2. Include these lists with the customer documentation. These are the current
working documents for activities performed on the MDF.
A31003-H3170-J100-2-7631, 05/2015
258 OpenScape 4000 V7, Installation Instructions
MDF Pin (a/b) BGR
SLO SLO
T 1 / 3 / 5 / 7 / 9 / 11/ 13/ 15/ 17/ 19/ 21/ 23/ 25/ 27/ 29/ 31/ 33/ 35/ 37/ 39/ 41/ 43/ 45/ 47/ T
2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48
C
016
C
015
C
014
C
013
C
A31003-H3170-J100-2-7631, 05/2015
012
C
011
Da 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 a-b
259
9_ExterneKabelbaugruppen.fm
260
1 / 3 / 5 / 7 / 9 / 11/ 13/ 15/ 17/ 19/ 21/ 23/ 25/ 27/ 29/ 31/ 33/ 35/ 37/ 39/ 41/ 43/ 45/ 47/ 49/ 51/ 53/ 55/ 57/ 59/ 61/ 63/ 65/ 67/ 69/
2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70
Creating a Strapping List, I.M.
External Cabling Assemblies
9_ExterneKabelbaugruppen.fm
Connector
9.6.2 Network Assignment 25/35 DA Strapping
Slot - D 0016 002 003 004 005 006 007 008 009 010 011 012 013 014 015 016 017 018 019
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 261
9_ExterneKabelbaugruppen.fm
External Cabling Assemblies
Creating a Strapping List, I.M.
A31003-H3170-J100-2-7631, 05/2015
262 OpenScape 4000 V7, Installation Instructions
10_Peripheriegeraete.fm
Installing Peripheral Equipment
Installing the AC-WIN IP Attendant Console
OpenScape 4000
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 263
10_Peripheriegeraete.fm
Installing Peripheral Equipment
Connecting the Service Terminal
Service
connector
BTT
A 230V∼ 230V∼
A
230V∼
Figure 1 Service terminal connection
A31003-H3170-J100-2-7631, 05/2015
264 OpenScape 4000 V7, Installation Instructions
10_Peripheriegeraete.fm
Installing Peripheral Equipment
HiPath SIRA (Secured Infrastructure For Remote Access)
Modem
connector
A A = Cable, C39195-Z7602-A30/100
TAE6D/
UAE 8/8 a/b MDF
MODEM
230V∼
Figure 2 HiPath SIRA
NOTE: The shield of all front cables (except network cables and optical fiber
cables) must be secured to the frame with two cable ties at the shelf opening. See
also Section 4.6, “Shielding Connection on the Opening of the LTU Frame”.
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 265
10_Peripheriegeraete.fm
Installing Peripheral Equipment
Connecting Cables
A31003-H3170-J100-2-7631, 05/2015
266 OpenScape 4000 V7, Installation Instructions
10_Peripheriegeraete.fm
Installing Peripheral Equipment
Connecting Cables
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 267
10_Peripheriegeraete.fm
Installing Peripheral Equipment
Connecting Cables
1 CO network -
IDN
5 10 9 2 wi.
7 25-pin
Signaling Modem
(max. 4 modems)
220 V∼
# = Maintenance port M, V.24, 15-pin cannon connector
1 = DIUT2 (digit. interf. unit T2): S30810-Q2226-X200
3 = PNE private network emulator: S30810-Q6400-X
or:
PBXXX peripheral board: S30810-Q6401-X
5 = Modem e.g. CPV, V.32bis: S30122-X5621-X
7 = V.24 cable, 15/25-pin cannon conn.,10m: C39195-Z7267-C2
8 = S2 cable, 15-pin cannon conn., open end: S30267-Z167-A..
9 = S-Y(St)Y 16x2x0.4 cable
10 = UAE 8/8 AP: L30460-X 951-X,
UP: L30460-X 952-X,
AP/UP: L30460-X 958-X
TAE6D: C39334-Z7052-C11
Figure 5 PNE/PBXXX back-to-back with modem in DIUS2 emulation with
DIUT2
A31003-H3170-J100-2-7631, 05/2015
268 OpenScape 4000 V7, Installation Instructions
10_Peripheriegeraete.fm
Installing Peripheral Equipment
Connecting Cables
LTUW OpenScape
MDF
NT/CO network -
3 2 ISDN
X2
adapter
PBXXX APPCU 2X15-pin 8 S2
X3
OpenScape MDF
2 NT/CO network -
LTUW ISDN
X2 S2 8
3 adapter
PBXXX
APPCU 2X15-pin
X3
1
6
Port 0
2X15-pin DIUT2
Port 1 Partially integrated mode is used for <
S2 Hicom E V3.0
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 269
10_Peripheriegeraete.fm
Installing Peripheral Equipment
Installing the Distance Adapter
1. At the back of the distance adapter, connect one end of a line cord to the UP0/
E connector (see Figure 8).
2. Connect the other end of the line cord to the Optiset E or OptiPoint telephone.
3. At the back of the distance adapter, connect another line cord to the PABX
U2B/1Q connector.
6. At the back of the distance adapter, connect the other end of the power supply
into the PS connector.
A31003-H3170-J100-2-7631, 05/2015
270 OpenScape 4000 V7, Installation Instructions
10_Peripheriegeraete.fm
Installing Peripheral Equipment
Installing the Distance Adapter
HiPath4000
4500
2 4
3
U 2B1Q 1
U P0/E
7
SLMQ3
(16 ports) 7 3 4
2
1
U 2B1Q U P0/E
6 5
EIA/TIA-232
40000152ger
1 - Distance adapter
2 - Optiset E (primary)
3 - Analog adapter
4 - Analog device
5 - EIA/TIA-232-E data device
6 - Data adapter
7 - 6000 meters
Figure 8 Connectivity options for the distance adapters
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 271
10_Peripheriegeraete.fm
Installing Peripheral Equipment
Installing the Distance Adapter
Front View
SIEMENS
Power Supply
PABX
UP0/E U2B/1Q PS
40000153
Figure 9 Distance adapter
A31003-H3170-J100-2-7631, 05/2015
272 OpenScape 4000 V7, Installation Instructions
11_IPDA.fm
Installing the IPDA
IMPORTANT: Refer to the OpenScape 4000 Service Manual for additional infor-
mation about the IPDA installations (IP solutions).
The system consists of a maximum 4 stacks (AP 3300 IP only) and one power
management unit attached to each other in a single row. The system can be
placed anywhere in the room (maximum expansion of 15 LTUW = 5760 ports).
Each stack can be configured with up to 4 boxes. The stacks are permanently
connected. A maximum of 6 wall main distribution frames (MDFHX6) can be
used. This corresponds to expansion up to a maximum 2304 ports.
Cabling should only be configured underfloor (double floor). The reference point
for system cabling is located at the lower end of the stack (see Figure 7).
The system can also be configured using IPDA instead of one single stack
(maximum of four boxes for every stack). These systems can be installed as free-
standing systems or can be built into a 19-inch cabinet.
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 273
11_IPDA.fm
Installing the IPDA
Peripheral
HG HG
modules
3570 3575
NOTE: Each cabinet, including the front cover, forms a shielded unit. Ensure to
lock the cabinets while the system is running and replace the covers immediately
following testing and maintenance.
A31003-H3170-J100-2-7631, 05/2015
274 OpenScape 4000 V7, Installation Instructions
11_IPDA.fm
Installing the IPDA
IPDA Connection Variants
OpenScape 4000
AP 3700-9 IP (9 slots)
HG3575 AP 3700-9 N
*-G5412-X C
AP 3700-9 N U
*-G5412-X C I
U 4
I LUN LUN LUNA
IP 4 A2 A2
2
LUNA LUNA LUNA
network
2 2 2
OpenScape 4000
AP3700-9 (9 slots) with OpenScape 4000
CSAPE, Survivability AP 3300 IP
Server N
HG3575
UP C
U
AP 3700-9 N L80XF I
*-G5412-X C
U 4
I
4 Router
LUNA LUNA LUNA
2 2 2
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 275
11_IPDA.fm
Installing the IPDA
IPDA Connection Variants
OpenScape
OpenScape 4000 -AP 3700-9 IP
UPR/ HG3570 AP 3700-9 N
UP Stack 1 C
STMI4 U
LTUW/ L
T I
L80XF U 1) 4
C IP LUNA LUNA LUNA
X 2) 2 2 2
network
LTUW/ L 2)
T
L80XF U Router
C
X
LTUW/ L HG3570
T STMI4
L80XF U 1)
C
X 2)
-AP 3300 IP
UCS UP HG3575
L80XF NCUI4
CSPCI 1)
CS-CPCI
Router
2)
A31003-H3170-J100-2-7631, 05/2015
276 OpenScape 4000 V7, Installation Instructions
12_Systemstart.fm
Starting the System
Completing the Installation
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 277
12_Systemstart.fm
Starting the System
Pre-Power On Checks
IMPORTANT: Do not use ESD procedures when working with power supplies.
If any power supplies becomes unseated during transport, reseat it by gently
pushing it toward the backplane until it seats in place.
2. Insert the peg of the board removal tool into the hole at the top of the
unseated board .
3. Lift the board removal tool and completely unseat the board.
5. Gently push the board toward the backplane until it seats in the backplane
connector.
1. Check that all signal cables are tightly secured at the connector on each shelf
backplane.
2. Check that the connectors on the other end of the signal cables are tightly
secured.
3. If signal cables were disconnected during transit, refer to the hardware map
to connect and secure these cables to the proper locations.
A31003-H3170-J100-2-7631, 05/2015
278 OpenScape 4000 V7, Installation Instructions
12_Systemstart.fm
Starting the System
Turning on a Nonredundant AC-Powered OpenScape 4000
7 WARNING
Observe all applicable safety precautions when working with high voltages.
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 279
12_Systemstart.fm
Starting the System
Turning on Cabinet 1 and 2 of a Redundant AC-Powered OpenScape 4000
7 WARNING
Observe all applicable safety precautions when working with high voltages.
2. At the back of the cabinet: Turn on the main circuit breaker under the CSPCI
shelf (see Figure 2 on page 283).
3. At the ACDPX board in UACD stack 1: Turn on the ac input power switches.
4. At the PDPX2 terminal field in UACD stack 1: Turn on the ac output power
module (PM1, PM2, and PM3) circuit breakers.
5. At the PDPX2 terminal field in UACD stack 1: Turn on the circuit breakers for
the
–48-V trunks (BULK and TALK).
6. At the back of UACD stack 1: Turn on the backup battery circuit breaker.
a) Shelf 1
8. At the PDPX2 terminal field in UACD stack 1: Turn on the power share circuit
breaker.
A31003-H3170-J100-2-7631, 05/2015
280 OpenScape 4000 V7, Installation Instructions
12_Systemstart.fm
Starting the System
Turning on Cabinet 3 and 4 of a Redundant AC-Powered OpenScape 4000
7 WARNING
Observe all applicable safety precautions when working with high voltages.
2. At the back of the cabinet: Turn on the main circuit breaker under the CSPCI
shelf (see Figure 2 on page 283).
3. At the ACDPX board in UACD stack 2: Turn on the ac input power switches.
4. At the PDPX2 terminal field in UACD stack 2: Turn on the ac output power
module (PM1, PM2, and PM3) circuit breakers.
5. At the PDPX2 terminal field in UACD stack 1: Turn on the –48-V circuit
breakers (BULK and TALK).
6. At the back of UACD stack 2: Turn on the backup battery circuit breaker.
a) Shelf 1
8. At the PDPX2 terminal field in UACD stack 2: Turn on the power share circuit
breaker.
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 281
12_Systemstart.fm
Starting the System
Turning on Cabinet 1 of a DC-Powered OpenScape 4000
1. At the dc system switchboard: Turn on and tag off the circuit breaker for the
dc electric circuit in cabinet 1.
2. At the back of cabinet 1 (under the CSPCI shelf): Turn on the main circuit
breaker (see Figure 2).
3. At the ICBP field in the UDCD cabinet in stack 1: Turn on the PMOD power
switches (see Figure 1).
4. Turn on the cabinet 1 dc-to-dc shelf power supplies in the following order:
5. At the front of UDCD cabinet 1 stack 1 ODP (Figure 3): Turn on the -48-V
TALK circuit breaker.
Figure 1 ICBP
A31003-H3170-J100-2-7631, 05/2015
282 OpenScape 4000 V7, Installation Instructions
12_Systemstart.fm
Starting the System
Turning on Cabinet 2 of a DC-Powered OpenScape 4000
+48 V
–48 V
Ground
Main to the base unit wire
circuit
breaker
Figure 2 Main circuit breaker, OpenScape 4000, rear view
1. At the dc system switchboard: Turn off and tag off the circuit breaker for
cabinet 2.
2. At the back of cabinet 2 (under the CSPCI shelf): Turn on the main circuit
breaker (see Figure 2).
3. At the ICBP field in UDCD cabinet 1 in stack 2: Turn on the PMOD power
switches (see Figure 1).
4. At the front of UDCD cabinet 1 stack 2 ODP: Turn on the -48-V BULK circuit
breaker (see Figure 3).
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 283
12_Systemstart.fm
Starting the System
Turning on Cabinet 3 of a DC-Powered OpenScape 4000
In cabinet 2 in the OpenScape 4000 system: Turn on the dc-to-dc shelf power
supplies in the following order:
5. At the front of UDCD cabinet 1 stack 2 ODP: Turn on the -48-V TALK circuit
breaker (see Figure 3).
1. At the dc system switchboard: Turn off and tag off the circuit breaker for
cabinet 3.
2. At the back of cabinet 3 (under the CSPCI shelf): Turn on the main circuit
breaker.
3. At the ICBP field in UDCD cabinet 2 in stack 1: Turn on the PMOD power
switches.
4. In cabinet 3 in the OpenScape 4000 system: Turn on the dc-to-dc shelf power
supplies in the following order:
7. At the front of UDCD cabinet 2 stack 1 ODP: Turn on the -48-V TALK circuit
breaker.
1. At the dc system switchboard: Turn off and tag off the circuit breaker for
cabinet 4.
2. At the back of cabinet 4 (under the CSPCI shelf): Turn on the main circuit
breaker.
3. At the ICBP field in UDCD cabinet 2 in stack 2: Turn on the PMOD power
switches.
4. At the front of UDCD cabinet 2 stack 2 ODP: Turn on the -48-V BULK circuit
breaker.
A31003-H3170-J100-2-7631, 05/2015
284 OpenScape 4000 V7, Installation Instructions
12_Systemstart.fm
Starting the System
Activating the RTC Battery on the DSCXL2 Board
5. In cabinet 4 in the OpenScape 4000 system: Turn on the dc-to-dc shelf power
supplies in the following order:
8. At the front of UDCD cabinet 2 stack 2 ODP: Turn on the –48-V TALK circuit
breaker (see Figure 3).
The RTC battery (Real-Time-Clock) for the system clock (lithium button cell 2032)
is located on the DSCXL2 board.
If an EcoServer is used instead of a CSPCI, the RTC battery will be located below
the hard disk slot (see HW description of EcoServer in the OpenScape 4000
Service Manual).
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 285
12_Systemstart.fm
Starting the System
Setting the Date and Time
IMPORTANT: Expect a time delay until the digital terminals have accepted the
change (time/date). The change (time/date) is only implemented on the attendant
console when you remove and then reinsert the handset cord.
NOTE:If the system is brought into the equipment room from a cold environment,
condensation may occur. Wait until the system temperature is balanced and the
system is completely dry before starting it up.
To perform a startup:
NOTE:If the customer HD has not been generated, it must first be generated (e.g.
in the Generation Center) and then swapped with the test database.
If a generated customer HD is available, replace the test database in the system
with the generated customer HD.
1. Ensure that the plug has been ECOS-tested for safety purposes.
3. Plug the LPC80 power plug into the base unit assembly (BUA) that is located
underneath the CSPCI box.
A31003-H3170-J100-2-7631, 05/2015
286 OpenScape 4000 V7, Installation Instructions
12_Systemstart.fm
Starting the System
Replacing the Covers
6. When starting the system with the test (database) (default state):
initiate the startup of the OpenScape 4000 system by pressing the LCT key
on the DSCXL2 board.
When starting the system with the generated customer HD:
the system starts up as soon as it is turned on.
7. Track the startup using the OLED (organic LED) display on the DSCXL2
board (see DSCXL2 board description in the "OpenScape 4000" service
manual).
IMPORTANT: Each cabinet, including the front cover, forms a shielded unit.
Ensure to lock the cabinets while the system is running and replace the covers
immediately following testing and maintenance.
2. Lock the top cover by turning the quick-release 90° to the left or right (1) until
the covers are firmly secured.
7 CAUTION
Risk of injury from falling unlocked covers
The covers are secure when you hear a click as you shut the cover. The cover
may fall off if it is not locked into place.
3. Install the cover to the cable channel (see Figure 5 on page 288).
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 287
12_Systemstart.fm
Starting the System
Replacing the Covers
Cable channel
covers
A31003-H3170-J100-2-7631, 05/2015
288 OpenScape 4000 V7, Installation Instructions
13_Systemueberpruefung.fm
Verifying the System
Tools Required
IMPORTANT: Each cabinet, including the front cover, forms a shielded unit.
Ensure to lock the cabinets while the system is running and replace the covers
immediately following testing and maintenance.
Use the following tools to perform the system verification procedures in this
chapter:
• Maintenance telephone with a direct inward dialing (DID) number and direct
trunk select capability enabled
• Transmission measuring test set (TMS) with singing return loss (SRL) and
echo return loss (ERL) capability (SAGE 930A with options 01 and 10C), P/N
66E4280
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 289
13_Systemueberpruefung.fm
Verifying the System
Checking the Cables
4. Check the line statuses using the TAP (analog circuits, digital circuits and
special circuits):
A list of abbreviations for features can be found in the OpenScape 4000 service
manual under the AMO description "FEASU".
To test the failure transfer function of the system (only with an analog trunk):
A31003-H3170-J100-2-7631, 05/2015
290 OpenScape 4000 V7, Installation Instructions
13_Systemueberpruefung.fm
Verifying the System
Backing up the Customer Data
3. After the test is complete, switch on the power to the system again (reload)
and wait until it has started up.
Best Practice processes can be referenced in the document "Best Practice Instal-
lation Process", which can be found in the partner portal.
• Remote maintenance
• Software patches
For hardware and software settings, please see the service manual description,
e.g. "HiPath Secured Infrastructure for Remote Access".
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 291
13_Systemueberpruefung.fm
Verifying the System
Checking the Ring Generator
IMPORTANT: If the ANATE telephone does not ring, check the ring generator
settings.
7 WARNING
Be extremely careful when working with the ring generator. High voltages
are present at the ring generator.
Ensure that the ring generator is jumpered as follows before powering on the
system: 85 V, 20 Hz. To check this setting:
3. Walk through the site to verify that the cabling has been completed according
to guidelines, and either accept the work or write a list of the corrections to be
made.
A31003-H3170-J100-2-7631, 05/2015
292 OpenScape 4000 V7, Installation Instructions
13_Systemueberpruefung.fm
Verifying the System
Verifying Transmission Facilities
For facilities that are utilized within complex networks the best balance choice
provides the highest ERL value that is equal to or greater than 18 dB and an SRL
low and high that are equal to or greater than 10 dB.
IMPORTANT: Do not select a balance network if the measured ERL value is less
than either of the measured SRL values.
Table 1 shows various sample return loss measurements. In this example the
best choice balance network would be network 3. Network 2 and 5 are acceptable
for local trunks. Network 4 is not acceptable.
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 293
13_Systemueberpruefung.fm
Verifying the System
Verifying Transmission Facilities
NOTE: Use this method only when more than one balance network meets the
minimum criteria set previously in Section 13.10.2, “Choosing the Balance
Network”. Do not include balance networks if the measurements fall below any of
the minimum level requirements.
1. Select a trunk.
2. Take the ERL and SRL measurements for all four networks on the selected
trunk.
3. Assign a quality factor rank (Q number 1 to 4) number, with 4 being the best
return loss measurement. Ignore the trunk if any measurement falls below
minimum requirements.
4. List the Q number for each balance network. Select the higher Q number
total.
In the event that two trunks have the same Q number total, select the network
with the highest ERL measurement. If both trunks have the same ERL
measurement, select the network with the highest SRL low measurement
followed by the highest SRL high measurement.
Net- ERL (dB) Q-No. SRL Low Q-No. SRL Q-No. Q-No.
work ERL (db) SRL Low High SRL Total
(db) High
2 13.7 2 10.2 2 11.0 2 6
3 18.6 4 13.2 3 12.5 4 11
4 6.2 5.7 6.1
5 15.7 3 14.1 4 14.3 3 10
A31003-H3170-J100-2-7631, 05/2015
294 OpenScape 4000 V7, Installation Instructions
13_Systemueberpruefung.fm
Verifying the System
Verifying Transmission Facilities
To determine the best central office (CO) trunk configuration, perform the
following:
IMPORTANT: The angle brackets (< >) indicate fields that require trunk
specific information.
4. Connect the transmission test set to the maintenance telephone port (Figure
1).
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 295
13_Systemueberpruefung.fm
Verifying the System
Verifying Transmission Facilities
-2.5 dBm
HiPath 4000
SLMA3 T
or ATI
R
TMC16 T
R
40000126ger
1 - Bridge clips
2 - MDF
3 - Demarc
4 - TMS
5 - Central office
6 - Maintenance telephone
Figure 1 Test setup for measuring ERL and SRL on CO trunk channels
7. Listen for CO dial tone. If you cannot get dial tone, ensure that it is not in use,
and then perform the CO trunk signaling tests.
9. Measure and note the ERL and SRL (low and high) values.
10. Repeat steps 1 through 9 of this procedure for balance network configura-
tions 3, 4, and 5.
11. Configure the balance network in the trunk configuration that provided the
best ERL and SRL values.
A31003-H3170-J100-2-7631, 05/2015
296 OpenScape 4000 V7, Installation Instructions
13_Systemueberpruefung.fm
Verifying the System
Verifying Transmission Facilities
b) Type the following field values and confirm every input with Enter:
Field Value
PEN <LTG-LTU-SLOT-CIRCUIT>
DEV DID
COFIDX 2
2. Activate the DID line to load the new balance network as follows:
b) Type the following field values and confirm every input with Enter:
Field Value
ONTYPE AUL
TYPE PEN
PEN1 <LTG-LTU-SLOT-CIRCUIT>
PEN2 <LTG-LTU-SLOT-CIRCUIT>
-2.5 dBm
HiPath 4000
T
Analog
board R
TMDID T
board R
40000127ger
1 - Bridge clips
2 - MDF
3 - Demarc
4 - TMS
5 - Central office
6 - Maintenance telephone
Figure 2 Test setup for measuring ERL and SRL on DID trunk channels
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 297
13_Systemueberpruefung.fm
Verifying the System
Verifying Transmission Facilities
6. Have the facility provider seize the DID trunk under test and then terminate it
with silent termination.
7. Using the TMS, measure and note the value of the ERL and the SRL.
8. Repeat steps 1 though 7 for balance network configurations with the COFIDX
set to 3, 4, and 5.
9. Configure the balance network in the trunk configuration that provided the
best ERL and SRL values.
b) Type the following field values and confirm every input with Enter:
Field Value
STNO <OPS extension #>
DEVFUNC ANATE
COFIDX 5
2. Activate the OPS line to load the new balance network as follows:
b) Type the following field values and confirm every input with Enter:
Field Value
ONTYPE AUL
TYPE STNO
STNO <OPS extension #>
3. Disconnect the maintenance telephone from the MDF block.
A31003-H3170-J100-2-7631, 05/2015
298 OpenScape 4000 V7, Installation Instructions
13_Systemueberpruefung.fm
Verifying the System
Verifying Transmission Facilities
1 - Demarc
2 - Bridge clips
3 - Transmission facilities
4 - MDF
5 - TMS
6 - Maintenance telephone
7 - Distant-end OPS telephone
Figure 3 Test setup for measuring ERL and SRL on OPS lines
8. Measure and note the ERL and SRL (low and high) values.
9. Repeat steps 1 through 8 for OPS line configurations for balance network
configurations 2, 3, and 4.
10. Configure the balance network in the line configuration that provided the best
ERL and SRL values.
1. Ensure that the local continuity and the end-to-end link tests have been
performed.
2. Ensure that personnel on the far end of the ISDN span have been assigned
to perform this verification procedure with you.
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 299
13_Systemueberpruefung.fm
Verifying the System
Verifying Transmission Facilities
b) Type the following field values and confirm every input with Enter:
Field Value
ONTYPE AUL
LTG <LTG>
LTU <LTU>
SLOT <SLOT>
4. Activate the D channel of the ISDN span as follows:
b) Type the following field values and confirm every input with Enter:
Field Value
ONTYPE AUL
PEN <PEN of the D channel>
5. Activate all the bearer channels of the ISDN span as follows:
b) Type the following field values and confirm every input with Enter:
Field Value
ONTYPE AUL
PEN <PEN1><PEN2>
The D channel becomes operational within 15 seconds.
If the D channel is not operational within 15 seconds after activation, check
the configuration for the different types of applications in Table 3 through
Table 6.
IMPORTANT: Record the device type and bipolar eight substitution infor-
mation.
A31003-H3170-J100-2-7631, 05/2015
300 OpenScape 4000 V7, Installation Instructions
13_Systemueberpruefung.fm
Verifying the System
Verifying Transmission Facilities
Table 6 TCSU configuration checks for AT&T, MCI, and SPRINT ISDN trunks
IMPORTANT: If all of the configurations are correct and the D channel is still not
operational, contact your next level of support.
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 301
13_Systemueberpruefung.fm
Verifying the System
Verifying Transmission Facilities
b) Type the following field values and confirm every input with Enter:
Field Value
ONTYPE AUL
TYPE PEN
PEN1 <PEN1>
PEN2 <PEN2>
2. Activate all the channels of the span as follows:
b) Type the following field values and confirm every input with Enter:
Field Value
ONTYPE AUL
TYPE <PEN>
PEN1 <PEN1>
PEN <PEN2>
3. Ensure that the local continuity and the end-to-end link tests have been
performed.
4. Perform a bit error rate test (BERT). Should the BERT fail, contact your local
provider.
Type the command DIS-BSSU and press Enter. Repeat this action several
times.
Field Value
LTG 1
LTU <LTU>
SLOT <SLOT>
CCTNO <blank>
DIS-TYPE <blank>
RESET <blank>
After 15 seconds, the T1 span enters the green alarm state and the following
errors stop increasing:
• Up slips (US)
A31003-H3170-J100-2-7631, 05/2015
302 OpenScape 4000 V7, Installation Instructions
13_Systemueberpruefung.fm
Verifying the System
Verifying the Hard Disk
2. If the drive is not ready, repeat steps 1a and 1b, and proceed to the following
steps:
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 303
13_Systemueberpruefung.fm
Verifying the System
Verifying the Operation of System Features and Servers
1. Print the following information by typing the commands shown in Table 7, one
at a time.
3. If STNTBL1=N, and DNOTBL1=N, then all stations are valid for CDR. If
STNTBL1=Y, and DNOTBL1=Y, find valid stations for CDR from the
command DIS-MLIST printout.
5. Make an external call from any valid station. The CDR must be sent either to
a printer or to a terminal when the call is completed.
8. Type the field value DIAFNO=<dialog field #>, and then press Enter.
10. If the dialog fields are free in the DIS-MFREQ command printout: type the
command ADD-MFREQ and press Enter.
11. Type the following field values and confirm every input with Enter:
Field Value
TYPE L
DIAFNO 1
FILE CDRC1
FILESTA <YYMMDDHHmm>
FILEND <YYMMDDHHmm>
FORMFORM0 2
BLKSIZE 127
FOUT Y
STAT YYMMDDHHmm>
MULTOUT N
PERIOD 0
SELSTOP Y
12. Make an external call from any valid station.
A31003-H3170-J100-2-7631, 05/2015
304 OpenScape 4000 V7, Installation Instructions
13_Systemueberpruefung.fm
Verifying the System
Verifying the Operation of System Features and Servers
14. Type the field value DIAFNO=<l> and then press Enter.
15. When the CDR test is finished, type the command DEL-MFREQ and press
Enter.
16. Type the field value DIAFNO=<l> and then press Enter.
3. Note the route number that is associated with the selected dialing pattern.
4. Note the first trunk group (route element) associated with the route number in
the Trunk Group Numbers and Route Numbers report.
a) Check the LCR schedule report to ensure that the LCR schedule
presently allows access to the selected route element. (Look at the Trunk
Group Numbers and Route Numbers report and note the letters under the
SCHEDULES field that have been marked with an X. Use these letters as
an input to the LCR schedule report.)
If the schedule blocks a call to that trunk group, change the system date
and time to comply with the schedule, by typing the command CHADATE.
b) Check for a READY status of the actual trunk circuits in that group by
typing the command DIS-SDSU-TK with the PENs found in the PEN
locations of the trunk circuits report.
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 305
13_Systemueberpruefung.fm
Verifying the System
Verifying the System Bypass
c) Check the AUTH field of the Trunk Group Numbers and Route Numbers
report to ensure that the LCOS for the maintenance extension is high
enough to use that route by typing the command DIS-SCSU to find the
LCOSV of the maintenance extension.
d) Check the AORT field of the Trunk Group Numbers and Route Numbers
report to ensure that the test number does not contain an area code or
office code that is blocked for that route. Use the AORT index number
from the Trunk Group Numbers and Route Numbers report in the DIS-
LAORT report to check this.
6. Dial a far-end test number that incorporates the selected dialing pattern.
Ensure that the call is complete.
7. Ensure that one of the trunks in the trunk group was seized by call processing,
by typing the command DIS-SDSU with the PENs found in the PEN Locations
of Trunk Circuits report. The initials CP should appear in the status field.
8. Deactivate the trunk group by typing the command DEADSSU with the PENs
found in the PEN Locations of Trunk Circuits report.
9. Repeat steps 4 through 8 with the remaining route elements (trunk group) in
the route.
10. Repeat steps 3 through 9 with the remaining dialing patterns in the Dialing
Patterns and Route Numbers report.
11. Repeat steps 2 through 9 with a ROLMnet extension from each route found
in the ROLMnet Dialing Patterns and Route Numbers report.
12. If the date and time were changed in step 5a, reset them to their correct
values.
2. Refer to the OpenScape 4000 Service Manual for the OLED information on
the DSCXL2 board to check whether the system bypass is functioning
properly.
A31003-H3170-J100-2-7631, 05/2015
306 OpenScape 4000 V7, Installation Instructions
14_Systemerweiterung.fm
Adding Cabinets to the System
Expansion Configuration
NOTE: The connecting screws between the individual cabinets are not used for
internal grounding purposes.
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 307
14_Systemerweiterung.fm
Adding Cabinets to the System
Connecting the Cabinet Stacks
1. Release the cabinet by turning the quick-release locks 90° to the left or right
(see Figure 2).
IMPORTANT: The housing cover and backplane are also secured in the
same manner as the expansion cabinets. This allows components to be
removed individually after the quick-release locks have been released.
Index Z
B G
Balance network Ground straps between individual cabinets 129, 130
overview 293 Ground straps for cabinet base 129
selecting 293 Grounding
Balancing CO trunks 295 AP 3700 cabinets 132
Balancing DID trunks 297 cabinet frame 131
Balancing OPS lines and trunks 298 LTU cabinets (internal) 131
Battery cable cross-sections 225 OpenScape 4000 system 127
Battery, connecting to the power box 165 Grounding overview 2 137
C H
Cable channels Hard disk, checking 303
installing 66 Hardware and symptom diagnosis 44
Cable routing
AP 3700-13 to MDF (MDFHX6) 240 I
LTU-MDF (MDFHX6) 239 Important information 20
Cabling assemblies, external 237 Important labels on the system 60
CDR Installation materials 50
applications 44 Installation notes 67
CO trunks, balancing 295 Installation procedures 47
Common control units Installation variants 95
overview 39 Installation with AP 3300 cabinets 95
Connecting the power box to the system 222 Installing seismic anchors 64
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 309
bkIX.fm
Index Nur für den internen Gebrauch
A31003-H3170-J100-2-7631, 05/2015
310 OpenScape 4000 V7, Installation Instructions
bkIX.fm
Nur für den internen Gebrauch Index
U
UACD power box 212
Unloading
system with roller base 53
UP/L80XF DC connection 162
Using this manual 11
V
Verifying
ISDN spans 299
system bypass 306
Verifying the hard disk 303
Verifying the system
tools required 289
W
Warning sign
Caution 18
Danger 15
Warning 16
A31003-H3170-J100-2-7631, 05/2015
OpenScape 4000 V7, Installation Instructions 311
bkIX.fm
Index Nur für den internen Gebrauch
A31003-H3170-J100-2-7631, 05/2015
312 OpenScape 4000 V7, Installation Instructions