You are on page 1of 1

REPORT ON TENSILE STRENGTH TESTS OF REINFORCING STEEL BARS

PROJECT REFERENCE : 505(2)-CWY-02PT


PROJECT NAME : Upgrading and Maintanance of DILI(Airport Junction) - TIBAR ROAD, Section 2
PROJECT LOCATION : Tasitolu - Tibar Road
MATERIALS : Grade 60 Deformed Steel Bars
SOURCE OF MATERIALS : JIANGSU YONGGANG GROUP CO., LTD/JIANYING XINCHEN, JIANGSU
CONTRACTOR : CHINA WU YI CO., LTD
CONSULTANT : KATAHIRA & ENGINEERS INTERNATIONAL
DATE OF SAMPLING : 5-Jul-2017
DATE OF TESTING : 6-Jul-2017

PHISICAL PROPERTIES MECHANICAL PROPERTIES


NOMINAL YIELD YIELD TENSILE TENSILE TS/YS
LENGTH WEIGHT AREA UNIT MASS ELONGATION
SAMPLE DIA. POINT STRENGTH LOAD STRENGTH RATIO
ID
KN
KN (Machine
m kg mm mm2 kg/m (Machine Mpa Mpa %
Reading)
Reading)
#16{)))} 0.50 16 201.0619 0 0 0 #DIV/0!
#16{)))} 0.50 16 201.0619 0 0 0 #DIV/0!
#32(XGG) 0.50 32 804.2477 0 0 0 #DIV/0!
#32(XGG) 0.50 32 804.2477 0 0 0 #DIV/0!
#32{)))} 0.50 32 804.2477 0 0 0 #DIV/0!
#32{)))} 0.50 32 804.2477 0 0 0 #DIV/0!

Requirements; (AASTHO M31): YS (min. Mpa) 620 TS (min. Mpa) 420


Remarks:

Tested By: Witnessed By:

JEREMIAS VALENTINO LI JINDI LYDIA B. VENTOLERO


Materials Quality Control Engineer Materials Quality Control Engineer Senior Quality Assurance Engineer
Supplied Personel - KEI China Wu Yi Co., Ltd Katahira & Engineers International

You might also like