• Acoustic (sound) energy in the form of waves

having a frequency above the human hearing


range
• High frequency sound wave
• Audible: 20Hz – 20000Hz
• Infrasound: Below 20HZ
• Ultrasound: Above 20 000Hz
ultrasound machine transmits high-frequency (1 to 5
megahertz) sound pulses into your body using a probe

sound waves travel into your body and hit a boundary


between tissues (e.g. between fluid and soft tissue, soft tissue
and bone)

Some of the sound waves get reflected back to the probe,


while some travel on further until they reach another
boundary and get reflected. The reflected waves are picked up
by the probe and relayed to the machine.

machine displays the distances and intensities of the echoes


on the screen, forming a two dimensional image like the one
shown below.
Power off
Transducer Power on Transducer
receiving
echoes
• Produced by passing an electrical current through a
piezoelectrical (material that expands and contracts with
current) crystal
• The FREQUENCY of the transducer
• The HIGHER the frequency, the LESS it can penetrate
• The LOWER the frequency, the DEEPER it can penetrate
• Attenuation is directly related to frequency
• The frequency also affects the QUALITY of the ultrasound image

The HIGHER the frequency, the BETTER the resolution


The LOWER the frequency, the LESS the resolution

A 12 MHz transducer has very good resolution, but cannot


penetrate very deep into the body

A 3 MHz transducer can penetrate deep into the body, but it


have poorer resolution compared to 12MHz transducer
• B-mode is termed as Brightness mode or normal 2D diagnostic
ultrasound presentation of echo-producing interfaces in a single plane.
• Function: To display tissue structure
Sector
Convex

0 n
0
1 1

2 2

Linear
• Color Doppler uses standard ultrasound methods to produce a picture of a
blood vessel
• Usually there are 2 types of color display: Red (toward the probe) & Blue
(away from the probe)
• Function: To display direction of blood flow
The average velocity is converted to a color mapping.
Generally, RED indicates toward the transducer and BLUE
away.
Scan direction
of ultrasound beam

This area is blue, so


flow is generally away
from the beam, right to left

This area is red, so


flow is toward the
beam, left to right
• PW mode is used to detect hemodynamic flow and velocity of blood flow.
• Function: To measure velocity of blood flow
• CW mode is used to detect high hemodynamic flow in cardiac
application.
• Function: To measure velocity of blood flow, especially in heart
Your Trusted Partner in Diagnostic Solutions

“An ideal solution for POC setup


in Primary Care”
THE BENEFIT OF POC SETUP
IN PRIMARY CARE

IMPROVE PATIENT TESTING TIME AND WAITING TIME


QUICK DIAGNOSIS AND DECISION MAKING
PATIENT SATISFACTION IN TERMS OF SAVING TIME AND COST
 BETTER PATIENT OUTCOME
INCREASE REFERRALS
About Active Scientific Sdn Bhd
About Active Scientific Sdn Bhd

ECG

HEMAGLOBIN &
HEMATOCRIT ANALYZER
VINNO Ultrasound

VINNO INTRODUCTION
VINNO Ultrasound

VINNO INTRODUCTION
Products

VINNO E10 & x1


• Shared Services
• Entry Level
VINNO 5, 6 & 8
• Emerging Applications

VINNO X2 3D/4D
• Shared Services
• Mid Value
• HQ Light
Products

VINNO E35
•Share service VINNO M55
•Value end VINNO G50 •Dedicated W/H
•Share service •Middle end
•Middle end

VINNO M86
•Dedicated W/H
VINNO G80 VINNO G60 •High End
•Share service •Share service
•High end •Middle/high end
VINNO Technology
• Traditional Ultrasound Platform
…. Image data processing platform 20 bits 8 bits

• Front End • Middle • Scan Conversion


probe Post processing •
• Beamforming • Demodulation Display

Hardware Software

• VINNO Innovative RF Ultrasound Platform


…. RF signal data processing platform for better resolution and definition
20 bits

• Front End • Scan Conversion


probe • Signal processing
• Beamforming • Display

Hardware Software
 40 times data to compute for better image quality  High resolution in micro imaging
 Higher dynamic data to adapt different application  Processing algorithm based on signal data, not image data
 Non-linear demodulation to strong signal  More accurate calculation by higher step algorithm
High Frequency Performance
Xcen probe High performance system Sensitive finger flow within 2mm
• Ultra wide bandwidth • System to be 25Mhz
• Competitive sensitivity • Better resolution with RF
• To reach 18Mhz data processing

Xtech probes
Normal PZT probes

Good resolution even in finger thread


Premium Linear image quality

fingernail
With RF data, automatically have sound speed match with certain tissue in
order to be enhanced, such as Tendon
VSpeckle (Speckle Reduction Imaging)

Thanks to Vinno RF platform, VSpeckle I and Vspeckle II can automatically enhances


contrast and reduces speckle, haze and other artifacts.
Excellent 3D/4D

Excellent image quality


Innovative rendering processing
Innovative user interface coming soon
Intuitive User Operation

 Ergonomic “iPad” type touch panel give much


smoother to operate

 Simple user interface to simplify your daily operation

 Unique and friendly operation in data management,


report, measurement configuration, map
configuration, comments…
Operation of Vinno Ultrasound
Easy Compare Auto Optimization
3D Smart Touch Auto Measurement
Touch Screen Comment TView
Body Mark TGC & SGC
Gray Map Tutorial
Measurement Setting Needle Guidance
Bluetooth/Email Images Transfer
Simple UI
Easy Compare
Comments

Click and paste,given fast annotation


Body Mark

Adjust Size and Position


Gray Map

Many types

无需键盘输入
Measurement Setting

Free editing on sequence


Connectivity
Bluetooth transfer images
Email transfer images

You might also like