You are on page 1of 8

A joint venture with AG! ASAHI Glassplant Inc.

, JAPAN

ACID
CONCENTRATION PLANTS

A TEAM SETS NEW STANDARDS


A joint venture with AG! ASAHI Glassplant Inc., JAPAN

ACID CONCENTRATION PLANTS


FROM IDEAL COMBINATION OF MATERIALS

ATR-ASAHI has the know-how to use Operating reliability is the highest priority.
advantageous and economical This is greatly enhanced by a correct
combination of materials for the various selection and combination of materials,
acid concentration application. The team and the maintenance effort is minimized-
of engineers takes the specific properties an important point for higher profitability
of, for example, PTFE, titanium, since, in addition to the capital costs,
tantalum, graphite, enameled steel and maintenance forms and increasingly
borosilicate glass into account. important cost factor.

2
NOx
ABSORPTION EXHAUST AIR
E4

E5
E2

C1 V1

E1 C2
T5

STEAM
E6

T6
STEAM

T2
STEAM T3
E3 AIR
P5
E7
E8 P3

T4

STEA
M P4

T1

P2

NA- WASTE WATER


65%
P1
NITRIC ACID
ABOVE 98%
SULPHURIC ACID 20% SULPHURIC ACID 70%
A joint venture with AG! ASAHI Glassplant Inc., JAPAN

Concentrating to medium Concentrating to high concentration


concentration
For further concentrating up to 93-96%
The following advantages in comparison H2SO4 the type of equipment used for
to other sulfuric acid evaporators also in concentrating to medium concentration
use: must be adapted to the changed physical
In forced circulation, no evaporation at the conditions in particular by:
heating surfaces, and therefore no, or
substantially reduced, fouling of the Lowering the operating pressure or raising
heating surfaces. the operating temperature to conform with
the sulfuric acid vapour pressure curve.
Higher heat transfer due to high liquid
velocities in the heater, and thus smaller Incorporation of a scrubbing column to
heating surfaces even for relatively small remove the vaporized acid fraction from the
temperature differences between the vapour.
heating steam and the boiling
temperature. The vacuum forced-circulation evaporator
already described has also proved effective
Due to the flash evaporation the high for concentrating up to 96%. The acid which
evaporating duly is fully retained at any has under gone preliminary purification by
vacuum. steam stripping is concentrated here in two
stages to 96% H2SO4.
Very reliable operation and rapid
adaptation to fluctuating throughput The acid which has been preconcentrated to
requirements of 0 to 100% of the capacity 85% in the first stage flows into the second
is made possible by the relatively small stage-via the scrubbing column; the vapour
hold-up; the plant cab be started-up and from this stage is compressed to the higher
shut down in a short time. operating pressure of the first stage by a
steam ejector.
Horizontal tube single pass evaporators
are also used. In this type of equipment
the waste acids are concentrated in
stages. In the chambers formed by the
segment weirs in a single pass. The
disadvantage compared with the forced
circulation system is the very much
greater susceptibility to fouling.

7
PRODUCTS
Process Plants With Guarantees
Nitric Acid Concentration.
Sulfuric Acid Concentration.
De-nitration and NOx absorption with acid recovery.
Integrated NAC/SAC.
Plants for recycling mixed acids / waste acids from the products of energetic
materials and other process industries.
Other Process Plants
Hcl gas generation with zero discharge.
Br2 recovery from NaBr solution.
Bromine production from bitterns.
Gas absorption for HCl, SO2, Cl2, HBr.
Sulfuric acid dilution.
Production of sodium hypochlorite.
Recovery precious metals from waste streams.
Solvent recovery plants.
Glass assemblies
For almost all unit operations distillation, absorption, adsorption,
extraction, crystallization, reaction
Overhead equipment on Glass Lined Vessels
Glass Process equipment
Column, Condensers, Falling film absorbers, Falling film evaporators,
Mixer-Settlers, Phase Separators, Dosing pump, Reaction Vessels &
Stirrers.
Glass Wiped Film Evaporators and Short Path Distillation apparatus.

Pilot Plants
For all unit operations, general purpose Reaction & Distillation,
Photochemical reactions.
Fully automated laboratory synthesis units, Mini plant for low-tonnage
productions
Plants for process validations.

Glass Shell & Tube Heat Exchangers


Main Condensers, Guard Condensers, Products Coolers, Thermo-
siphon Reboilers, Waste Heat Economizers
Also with SiC tubes, Special design high pressure exchangers.

SERVICES
Design & Supply of Glass Pilot Plants and Process Plants
Basic Engineering Detailed Engineering
Stage-wise inspections Erection at site Mechanical Testing
Commissioning De-bottlenecking & streamilining
Preparation of as built drawings
Design & Supply of custom-made equipments

PROCESS HEAT TRANSFER


0 0
Single fluid heating / cooling units for Kilo Labs and Mini-plants (-90 C up to 200 C)
Single fluid heating / cooling systems for production plants.

PROCESS AUTOMATION
Turnkey PLC / DCS based systems

668, GIDC Makarpura


Vadodara 390 010, India
Tel: +91 (0265) 30 48 746 Via S. Domenico Savio, 31
Fax: +91 (0265) 26 33 423 25086 Rezzato (BS)
processplant@atrasahiglass.com ITALY
www.atrasahiglass.com Phone: +39 030 2590781, Fax: +39 030 2592531
A joint venture with AG! ASAHI Glassplant Inc., JAPAN Email: ambrosi.luigi@tin.it