Home Inspection Checklist

Address: A-05-07, Apartment Taman Putra Impian, Taman Putra Impian, Kajang Selangor
Date: 15/02/2019

Bathrooms Bathroom Master Bathroom 1 Bathroom 2


Code OK Code Summary Code Summary
Baseboards
Cabinets, shelves, & drawers
Ceiling
Counter
TM2 Door opening near to toilet seat
Doors T1.2 Door opening near to toilet seat
TM3 Got paint at door
Floors TF21-23 Tiles got hollow sound Yellow label Tiles got hollow sound
Stock Cork
Lights
Vent pipe TM Pipe need to be clean T1.1 Pipe need to be clean T2.1 Pipe need to be clean
Outlets and switches
Sink
Toilet
Towel hook
Water tap
Tub and shower
T1.10-18 Tiles got hollow sound Yellow label Wall tiles got hollow sound
Yellow
Walls Tiles got hollow sound T1.19,20 Whole area- tiles hollow sound T2.2 Need touch up tiles around
label
T1.3 Need grouting tiles around pipe pipe
Window T2.4 Window cannot close tightly

Fixtures secure? Condition of tiles and calking? Leaks or water pressure issues? Mold? Drawers and cabinets working?

Notes: Please re-check tiles at all area. This may be caused by improper installation method. Either the installer just “spot bonding” or the mixture of adhesive not follow the
standards.

House Defects Investigator H.D.I Ventures


Hall and
Balcony Code Summary Front Door Code Summary
Area
Fence B1 Rusty railing, need touch up paint Front Door FD1-6 Tiles got hollow sound
HCP24 Uneven paint at ceiling
Ceiling Ceiling
HCC20,21 Crack at ceiling beam
Floors B2 Tiles got hollow sound Ceiling Fan X Fan hook too close with ceiling beam
Lights Doors HDC 7-11,14-19 Crack at door frame area
Outlets and switches Floors H1-6 Tiles got hollow sound
Trim Lights
Outlets & HX Uneven skim at switches area
Walls
switches HX1 Got paint , need to be clean
Windows Cabinet TC,TC2 No cabinet cover and shelves
HDC12 Wall got crack
Wall damage? Sloping ceiling? Weak floors? Walls HDS13,23 Uneven skim
HDP22 Uneven paint
Notes: Windows
Wall damage? Sloping ceiling? Weak floors?

Notes: Have to hack at least 1 or 2 inches width all along at crack line and
Cement back . Don’t just paint or use stopping to cover the crack up.

House Defects Investigator H.D.I Ventures


Bedrooms Master Bedroom Bedroom 1
Code Summary Code Summary
Outside
B1CC Ceiling got crack
Ceiling
B1CS Uneven skim ceiling
Closet MBC1 Got paint at closet door
Doors MBDC 6-10 Crack at door frame area B1DC 14,15,23 Crack at door frame area
Floors MB1-5 Tiles got hollow sound B1.1-13 Tiles got hollow sound
Lights
Switches MBX Uneven skim at switches area
Trim
MBDC 11,12 Wall got crack B1DS 16,18 Uneven skim
Walls
MBDS 13 Uneven skim B1DC 17,19,21 Wall got crack
Windows
Bedrooms Bedroom 2 Bedroom 3
Code Summary Code Summary
Outside
Ceiling
Closet
Doors B2DC 22,23 Crack at door frame area
Floors B2.1-22 Tiles got hollow sound
Lights
Switches B2X Uneven skim
Trim
B2DC 24 Wall got crack
Walls
B2DS Uneven skim
Windows B2.25 Dirty window
Check ceilings for sloping and/or water damage. Are floors weak in places? Damaged windows or window screens?

Notes:

House Defects Investigator H.D.I Ventures


Kitchen Code Summary

Baseboards

Cabinets and drawers KC1 Misaligned cabinet door Utilities Code Summary
Ceiling Air conditioning
Stop Cock Valve Circuit breakers
Water Tap Drainage
Floors KF1-5 Tiles got hollow sound Fire Extinguisher

Garbage Disposal Hot water heater


Main electrical
Water trap KF6 Drain pipe too long
panel
Lights Water pressure

Outlets and switches


Notes:
Door

Refrigerator

Sink
Walls KW6-11 Whole area-tiles got hollow sound
Windows
Leaking sink or appliances? Cabinet & drawer condition?

Notes: