You are on page 1of 2

Section 8: Broadcasting Standards

1. D. Loose connections in the oscillator, amplifier, or antenna circuits


2. B. Mean power
3. B. 80 kW
Solution:
Given: Gf= 2
Pt= 20kW
Req’d: ERP=?
𝐸𝑅𝑃 = 𝑃𝑡(𝐺𝑓)2
𝐸𝑅𝑃 = 20𝑥103
𝐸𝑅𝑃 = 80,000
𝐸𝑅𝑃 = 80𝑘𝑊

4. A. Local oscillator
5. C. 525 lines
6. B. 485 lines
7. D. 525 lines
8. D. During experimental period
9. C. MOPA
10. A. heating of capacitor in the oscillator
11. A. Class C
12. D. Low Band VHF
13. B. 5
14. C. 52 s
15. A. TVRO
16. B. Carrier Power
17. B. FM
18. A. Through installing a band-pass filter in the antenna feed line
19. B. Television
20. C. Back Wave
21. B. MF
22. A. 20 kW
23. 1.3 Mhz
24. C. Band reject filter
25. C. Surface Loam Soil
26. C. Indirect
27. D. 30 to 53 kHz
28. A. Local oscillator
29. A. vestigial Sideband
30. A. J.L Baird

Solving #3:
Given: Gf= 2
Pt= 20kW
Req’d: ERP=?
Solution:
𝐸𝑅𝑃 = 𝑃𝑡(𝐺𝑓)2
𝐸𝑅𝑃 = 20𝑥103
𝐸𝑅𝑃 = 80,000
𝐸𝑅𝑃 = 80𝑘𝑊