50ZP (60Hz)

Single-Package
Air Conditioners
3 - 5 Nominal Tons

Product Data
The 50ZP is a package air conditioner for manufactured housing, residential, and light commercial applications.
The 50ZP unit design is the result of our firm commitment to the development of the finest air conditioners that
modern technology can offer. The 50ZP unit is built in one basic cabinet size and features rectangular duct
configuration on sizes 036-060.

Features/Benefits
FACTORY-ASSEMBLED PACKAGE is a compact, fully
self-contained, electric cooling unit with horizontal supply
and return ducts. The 50ZP units are available in a variety
of standard cooling sizes with voltage options to meet
residential and light commercial requirements. Unit
installs easily on a ground level pad.

EASY TO INSTALL
50ZP units are small, compact, and easy to handle.
Every 50ZP unit has an identical 32 x 51-in. footprint to
make planning simple. The concise design uses less
sheet metal and makes the 50ZP units lighter than other
units. The unit can be easily positioned on the jobsite
with the hand-holds built into the unit basepan. Drop-in
cartridge style heaters are utilized to minimize
installation time. The 50ZP unit was designed with
potential safety hazards in mind; with no sharp edges or
corners which could injure a worker.

NEW IMPROVED AERODYNAMIC FAN BLADE DESIGN


reduces the overall sound by up to 6dB; now as low as
78dB.

TOP COVER SERVICE ACCESS


Makes installation and maintenance quicker and easier.
The 50ZP units are designed to be serviced from the top.
The split-top design allows easy access for installation and
maintenance procedures of the unit. Routine maintenance
tasks such as coil cleaning are sped up with through-the-
top access. Multiple side panels do not need to be
removed as with other units.

NO-RUST BASEPAN WITH


INTEGRATED DRAIN PAN
Is standard on all units. The 50ZP units feature a toug
hightech, composite material basepan with integrated
drain pan. The composite material eliminates the potential
problems of rust and premature replacement which are
common with standard metal basepans. Durable oven
backed polyester powder painted galvanized steel)
protects against harsh weather.

50ZP-04 PD 2011
The watertight construction and corrosion- performance level can reduce cooling expenses Controls — Contains high- and
resistant finish of the 50ZP unit will by as much as 25% compared to older cooling low-pressure switches to protect the unit from
keep it looking like new for years. The paint equipment. A high-eficiency, multi-speed running at unsuitable pressures. Provides
treatment process ensures quality protection blower motor system ensures quality additional safety features when needed.
against the elements. performance with most duct systems. The
computer-designed blower wheel is balanced Solid-State Time Guard® Device —
INDOOR AIR QUALITY is designed into the for quiet operation. Provides a 5-minute delay in compressor
50ZP units. A sloped drain pan minimizes the operation between cooling cycles. Prevents
amount of standing water inside the unit, which DURABLE, DEPENDABLE,
COMPRESSORS are designed for high compressor short cycling when rapid
limits mold and mildew growth. The drain pan
efficiency. Each compressor is hermetically compressor cycles may be a problem.
is made of a rust-proof material and will not
deteriorate or release foreign matter into the sealed against contamination to help promote FIELD-INSTALLED ACCESSORY
airstream. longer life and dependable operation. Vibration DESCRIPTION AND USAGE
isolation provides quiet operation. Compressors
LIGHTWEIGHT, COMPACT have internal high-pressure and overcurrent Electric Heater — Heater module slides into
CONSTRUCTION is ideal for manufactured protection. keyed mounting slots in the fan inlet. Heater
housing and residential applications. The 50ZP sizes range from 5.0 to 20.0 kW. Design allows
unit is one of the lightest, most compact DIRECT-DRIVE MULTISPEED, PSC
for single-point supply for entire unit. Heaters
packaged units ever designed. It’s light weight (PERMANENT SPLIT CAPACITOR)
provide heating capability when required.
(250 lbs for the 50ZP 036 unit) makes the unit BLOWER MOTOR is standard on all models.
easier to handle. The low height keeps ductwork Direct-drive, PSC condenser-fan motors are Crankcase Heater — Warms crankcase oil to
connections to a minimum and makes units less designed to help reduce energy consumption reduce refrigerant migration and ensure proper
visible. and provide for cooling operation down to 40 F. compressor lubrication. (Field Installed).
REFRIGERANT SYSTEM is designed to Outdoor Thermostat — Accessory provides
The 50ZP units utilize a structural beam design
provide dependability. Liquid refrigerant control when outdoor-air temperature falls
to form the four sides of the cabinet. Only 12
strainers are used to promote clean, unrestricted below set point. Helps to bring second stage of
different pieces of sheet metal are used in the
operation. Each unit leaves the factory with a 2-stage electric heater on line.
unit construction to simplify the unit for greater
reliability. full refrigerant charge. Refrigerant service
50ZP

connections make checking operating pressures


EFFICIENT, DEPENDABLE easier.
PERFORMANCE with durable compressors
designed for efficiency. The 50ZP units offer
9.5 SEER (Seasonal Energy Efficiency Ratio)
cooling performance efficiencies. This

AHRI* capacity ratings NOTES:


1. Ratings are gross values, excluding the effects
Gross SOUND of circulating fan heat.
UNIT STANDARD
COOLING SEER # RATINGS ## 2. Cooling capacity ratings are based on cooling
50ZP CFM
CAPACITY** (dB)
standard:
036 35,500 1200 9.5 78 80°F db/67°F wb indoor air entering temperature
042 41,700 1400 9.5 78 95°F db air entering outdoor unit
048 47,700 1600 9.5 78
060 62,120 2000 9.5 80

LEGEND * Air Conditioning, Heating & Refrigeration Institute.


db — Dry Bulb ** Rated in accordance with U.S. Government DOE Department of
dB — decibels Energy) test procedures and/or AHRI Standard 210/240-89.
SEER — Seasonal Energy Efficiency Ratio # All units have factory-installed time-delay relay.
wb — Wet Bulb ## Rated in accordance with AHRI Standard 270-84.

Table of contents Page


Features/Benefits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
AHRI Capacity Ratings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Model Nomenclature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Physical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Dimensional Drawings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-7
Performance Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-10
Typical Wiring Schematics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11-13
Selection Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
Electrical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Operating Sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Typical Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Application Data. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Engineers’ Specification Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

2
MODEL NUMBER NOMENCLATURE

50ZP 036 - 5 1 1 S

50ZP – Packaged Rooftop


- Electric Cooling
- Electric Heater Accessory
High Ambient
Nominal Cooling Capacity
036 Ö 3 Tons
042 Ö 3.5 Tons Standard
048 Ö 4 Tons
060 Ö 5 Tons
Series
Electrical Supply
3- 208/230 -1-60

50ZP
5- 208/230 -3-60

Physical Data
50ZP UNIT SIZE 036 042 048 060
Operating Weight (lb) 250 297 310 350
Compressor Type Reciprocating
Refrigerant R-22
Charge (lb) 4.7 4.4 6.1 7.5
Refrigerant Metering Device Acutrol TM System
Condenser Coil Copper Tubes, Aluminum Plate Fins
Rows – Fins/in. 1 – 17 1 – 17 2 – 17 2 – 17
Total Face Area (sq ft) 6.2 11.1 8.6 10.7
Condenser Motor Propeller
Condenser Cfm 2200 2800 2800 3000
Nominal Rpm 1100 1100 1100 1100
Motor Hp (Rpm) ¼ ¼ ¼ ¼
Diameter (in.) 20 20 20 20
Evaporator – Fan Motor Direct Drive
Blower Motor Size (in.) 10 × 8 10 × 9 10 × 9 10 × 10
Nominal Cfm 1200 1400 1600 2000
Rpm Range 800 – 1000 800 – 1000 900 - 1075 950 – 1100
Number of Speeds 3 3 2 2
Factory Speed Setting Low Med Low Low
Motor Hp ½ ½ ¾ 1
Connecting Duct Sizes Square
Supply Air (in.) 13.9 × 10.9 13.9 × 13.9
Return Air (in.) 13.9 × 11.5 13.9 × 27.8
Field- Supplied Return Air Filter*
24 × 24 × 1 24 × 24 × 1 24 × 30 × 1 24 × 30 × 1
Throwaway
Required filter sizes shown are based on the AHRI (Air conditioning, Heating & Refrigeration Institute) rated airflow at a
velocity of 300 ft/minute for throwaway type or 450 ft/minute fir high-capacity type.
Recommended filters are 1-in. think.

3
Dimensional drawings — 50ZP 036
50ZP

D C

Corner weights distribution (kg)


Corner ”A” Corner ”B” Corner ”C” Corner ”D”
weight weight weight weight
25 39 30 20

A B

4
Dimensional drawings — 50ZP 042

50ZP
D C

Corner weights distribution (kg)


Corner ”A” Corner ”B” Corner ”C” Corner ”D”
weight weight weight weight
30 46 36 23

A B

5
Dimensional drawings — 50ZP 048
50ZP

D C

Corner weights distribution (kg)


Corner ”A” Corner ”B” Corner ”C” Corner ”D”
weight weight weight weight
31 48 38 24

A B

6
Dimensional drawings — 50ZP 060

50ZP
D C

Corner weights distribution (kg)


Corner ”A” Corner ”B” Corner ”C” Corner ”D”
weight weight weight weight
35 55 42 27

A B

7
Cooling capacities (Gross)
50ZP036
EVAPORATOR CONDENSER AIR TEMPERATURE (F)
AIR 85 95 105 115 125
F Capacity MBtuh Compressor Capacity MBtuh Compressor Capacity MBtuh Compressor Capacity MBtuh Compressor Capacity MBtuh Compressor
Cfm BF
Ewb Total Sensible kW Total Sensible kW Total Sensible kW Total Sensible kW Total Sensible kW
72 39.8 19.9 3.65 37.9 19.2 3.83 35.9 18.6 4.02 33.8 18 4.20 31.90 17.20 4.69
1050 0.08 67 36.7 25.5 3.53 34.7 24.8 3.71 32.7 24 3.88 30.7 23.4 4.05 28.10 21.26 4.41
62 33.3 30.6 3.42 31.5 29.7 3.59 29.6 28.7 3.75 27.8 27.7 3.91 23.70 23.69 4.26
72 40.9 21 3.74 38.8 20.4 3.92 36.8 19.9 4.11 34.3 19 4.27 32.80 18.53 4.73
1200 0.10 67 37.5 27.3 3.61 35.5 26.6 3.79 33.4 25.8 3.96 31.4 25.1 4.14 29.10 23.16 4.46
62 34.3 32.8 3.15 32.4 31.8 3.67 30.6 30.6 3.84 29 29 4.03 25.30 25.35 4.33
72 41.3 21.9 3.80 39.4 21.5 3.99 37.2 20.7 4.17 35 20.1 4.36 33.50 19.70 4.78
1350 0.11 67 38.4 29.2 3.70 36.2 28.3 3.87 34.1 27.5 4.03 32 26.8 4.21 30.10 25.27 4.53
62 35.1 34.8 3.59 33.4 33.4 3.76 31.8 31.8 3.94 30.1 30.1 4.13 27.30 26.17 4.30

50ZP042
EVAPORATOR CONDENSER AIR TEMPERATURE (F)
AIR 85 95 105 115 125
F Capacity MBtuh Compressor Capacity MBtuh Compressor Capacity MBtuh Compressor Capacity MBtuh Compressor Capacity MBtuh Compressor
Cfm BF
Ewb Total Sensible kW Total Sensible kW Total Sensible kW Total Sensible kW Total Sensible kW
72 47.5 23.4 4.19 45 22.5 4.39 42.4 21.6 4.60 39.7 20.7 4.81 36.40 20.35 5.20
1225 0.11 67 40.3 26.9 3.89 39.7 27.4 4.17 37.8 27 4.40 35.5 26.4 4.62 31.80 26.31 4.90
62 37.6 33.1 3.81 36 32.8 4.03 34.1 32.1 4.25 31.8 31.1 4.45 29.10 29.10 4.70
72 48.7 24.7 4.28 46 23.8 4.49 43.4 22.9 4.70 40.5 22 4.89 37.60 22.06 5.24
1400 0.12 67 39.8 27.1 3.92 41.7 28.9 4.24 38.6 28.9 4.49 36.3 28.3 4.71 32.80 28.69 4.96
50ZP

62 38.2 34.6 3.88 36.9 34.9 4.13 34.9 34.3 4.34 33 33 4.56 30.90 30.90 4.82
72 49.6 26 4.37 46.8 25.1 4.58 44 24.1 4.78 41.2 23.2 4.98 38.50 23.65 5.27
1575 0.14 67 39.1 26.9 3.95 40.4 29.9 4.30 39.3 30.6 4.57 37.1 30.2 4.80 33.90 31.04 5.02
62 38 35.1 3.93 37.6 36.6 4.21 35.9 35.8 4.44 34.2 34.2 4.68 32.60 32.60 4.92

LEGEND 3. The sensible heat capacity is based on 80°F edb temperature of air
BF — Bypass Factor entering indoor coil.
Ewb — Entering Wet Bulb Below 80°F edb, subtract (corr factor x cfm) from the sensible heat
Idb — Leaving Dry Bulb capacity.
Iwb — Leaving Wet Bulb Above 80°F edb, add (corr factor x cfm) to the sensible heat
MBtuh — 1000 Btuh (gross) capacity. Correction Factor = 1.10 x (1–BF) x (edb – 80).

NOTES:
1. Direct interpolation is permissible. Do not extrapolate.
2. The following formulas may be used:
sensible capacity (MBtuh x 1000)
t = t ⴚ
ldb edw 1.10 x cfm
t lwb = Wet-bulb temperature corresponding to enthalpy of air leaving
indoor coil (h lwb )
total capacity (MBtuh x 1000)
hlwb = hewbⴚ
4.5 cfm
Where: h ewb = Enthalpy of air entering indoor coil

8
Cooling capacities (cont)
50ZP048
EVAPORATOR CONDENSER AIR TEMPERATURE (F)
AIR 85 95 105 115 125
F Capacity MBtuh Compressor Capacity MBtuh Compressor Capacity MBtuh Compressor Capacity MBtuh Compressor Capacity MBtuh Compressor
Cfm BF
Ewb Total Sensible kW Total Sensible kW Total Sensible kW Total Sensible kW Total Sensible kW
72 46.8 22.5 4.42 48.5 24.6 4.88 47.3 24.9 5.23 42.6 44.4 24.1 41.80 23.48 6.01
1400 0.06 67 45.6 31.2 4.41 45.4 32.6 4.77 42.9 31.9 5.03 38.1 39.9 31 36.50 29.77 5.72
62 43.5 39.6 4.34 41.4 39.2 4.60 38.9 38.2 4.85 34.6 36.4 36.4 33.00 33.00 5.49
72 45.4 22 4.42 48.1 24.3 4.89 48 26.1 5.33 42.9 45.1 25.6 43.00 25.13 6.83
1600 0.07 67 44.4 30.6 4.42 47.7 34.3 4.86 43.7 34.2 5.14 38.5 40.7 33.4 37.80 32.42 5.79
62 43.7 41.1 4.42 42.3 41.7 4.72 40.2 40.2 4.98 35.7 37.9 37.9 35.10 35.10 5.60
72 44.1 22.4 4.44 46.2 24 4.90 47.7 26.7 5.38 43.2 45.8 27 44.00 26.74 6.11
1800 0.08 67 43.3 30.2 4.43 45.3 34.7 3.90 44.3 36.3 5.25 38.7 41.3 35.6 38.90 34.83 5.85
62 42.7 40 4.44 43.1 43 4.83 41.5 41.4 5.12 36.7 39.3 39.2 36.90 36.90 5.69

50ZP060
EVAPORATOR CONDENSER AIR TEMPERATURE (F)
AIR 85 95 105 115 125
F Capacity MBtuh Compressor Capacity MBtuh Compressor Capacity MBtuh Compressor Capacity MBtuh Compressor Capacity MBtuh Compressor
Cfm BF
Ewb Total Sensible kW Total Sensible kW Total Sensible kW Total Sensible kW Total Sensible kW
72 68.1 33.4 6.22 67.6 34 6.78 64.3 33 7.22 60.5 31.8 7.60 54.8 30.4748 8.16

50ZP
1750 0.06 67 64.8 44.3 6.16 61.2 43.1 6.55 57.9 41.6 6.87 54.3 40.4 7.27 47.6 38.51 7.59
62 57.1 50.8 5.80 55 50.4 6.21 52.1 49.5 6.60 48.9 48.2 6.97 42.9 42.9 8.40
72 66.5 33.42 6.23 68.4 35.52 6.90 65.62 35.12 7.38 61.6 33.62 7.75 56.32 32.912 8.16
2000 0.07 67 66.1 47.22 6.30 62.1 46.32 6.72 58.82 44.32 7.01 55.6 43.52 7.43 49.32 41.928 7.70
62 55.9 50.52 5.82 56.1 53.82 6.35 53.52 52.92 6.76 50.8 50.72 7.17 45.72 45.72 7.40
72 64.8 32.8 6.23 67.9 36.1 6.95 66.5 36.8 7.51 62.5 35.4 7.88 57.6 34.92 8.21
2250 0.08 67 67.3 50.1 6.43 63.9 49.3 6.86 59.6 46.8 7.14 56.4 46.5 7.57 50.9 45.224 8.96
62 54.4 49.7 5.84 56.7 55.9 6.47 55 54.9 6.93 52.6 52.6 7.37 48.2 48.2 7.56

LEGEND 3. The sensible heat capacity is based on 80°F edb temperature of air
BF — Bypass Factor entering indoor coil.
Ewb — Entering Wet Bulb Below 80°F edb, subtract (corr factor x cfm) from the sensible heat
Idb — Leaving Dry Bulb capacity.
Iwb — Leaving Wet Bulb Above 80°F edb, add (corr factor x cfm) to the sensible heat
MBtuh — 1000 Btuh (gross) capacity. Correction Factor = 1.10 x (1–BF) x (edb – 80).

NOTES:
1. Direct interpolation is permissible. Do not extrapolate.
2. The following formulas may be used:
sensible capacity (MBtuh x 1000)
t = t ⴚ
ldb edw 1.10 x cfm
t lwb = Wet-bulb temperature corresponding to enthalpy of air leaving
indoor coil (h lwb )
total capacity (MBtuh x 1000)
hlwb = hewbⴚ
4.5 cfm
Where: h ewb = Enthalpy of air entering indoor coil

9
WET COIL PRESSURE DROP
UNIT SIZE AIRFLOW PRESSURE DROP
50ZP (cfm) (in. wg)
1000 0.04
1200 0.05
036
1400 0.07
1600 0.08
1000 0.04
1200 0.05
042
1400 0.07
1600 0.08
1400 0.07
048 1600 0.08
1800 0.09
1700 0.07
1800 0.08
060
2100 0.09
2300 0.10

FILTER PRESSURE DROP (in. wg)


UNIT FILTER CFM
SIZE SIZE
50ZP (in.) 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000 2100 2200 2300
036-042 24 X 24 0.08 0.08 0.09 0.09 0.09 0.10 0.11 0.12 0.14 0.15 — — — — — — —
048,060 24 X 30 — — — — — — 0.08 0.09 0.10 0.11 0.12 0.13 0.14 0.15 0.16 0.17 0.18

ACCESSORY ELECTRIC HEAT PRESSURE DROP (in. wg)


50ZP

HEATER CFM
kW 600 800 1000 1200 1400 1600 1800 2000 2200
5 – 20 0.06 0.08 0.10 0.13 0.15 0.18 0.20 0.23 0.25

DRY COIL AIR DELIVERY* — HORIZONTAL DISCHARGE


(Deduct 10% for 208-Volt Operation)
230 Volt Horizontal Discharge
Unit Motor Air
External Static Pressure (in.wg)
50ZP speed Delivery 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9
Watts 450 435 420 400 380 335 326 311 —
Low
CFM 1231 1218 1204 1120 1008 950 863 751 —
Watts 470 450 445 410 388 359 338 321 —
036 Med
CFM 1302 1264 1205 1163 1081 940 873 783 —
Watts 660 635 610 575 540 505 485 460 —
High
CFM 1700 1660 1581 1450 1297 1190 1095 989 —
Watts 478 458 440 411 378 350 327 317 —
Low
CFM 1303 1270 1224 1179 1126 1022 911 816 —
Watts 481 468 450 438 404 370 338 320 —
042 Med
CFM 1310 1280 1241 1181 1110 1022 943 811 —
Watts — 798 678 647 618 578 540 500 460
High
CFM — 1736 1688 1618 1510 1421 1309 1187 1060
Watts — — 801 760 730 688 650 600 570
Low
CFM — — 1898 1841 1757 1682 1564 1429 1365
048
Watts — — 870 842 818 782 696 632 628
High
CFM — — 2000 1903 1799 1718 1625 1446 1333
Watts 890 850 810 790 735 680 580 480 422
Low
CFM 1834 1820 1791 1762 1703 1640 1415 1159 950
Watts 1040 1018 1000 950 890 835 790 650 580
060 Med
CFM 2230 2102 2025 1960 1901 1855 1752 1468 1121
Watts 1073 1038 1001 958 896 840 800 691 575
High
CFM 2230 2202 2160 2122 2052 1926 1791 1588 1202

*Air delivery values are based on , dry NOTES:


coil, without filter or electric heater. Deduct wet coil, filter, and electric 1. Do not operate the unit at a cooling airflow that is less than 350 cfm
heater pressure drops to obtain external static pressure available for for each 12,000 Btuh of rated cooling capacity. Evaporator-coil frost-
ducting. ing may occur at airflows below this point.
2. Dashes indicate portions of the table that are beyond the blower mo­
tor capacity or are not recommended.
10
Typical wiring schematic — 208/230-1-60

50ZP

11
Typical wiring schematic — 208/230-3-60
50ZP

12
Typical field wiring (cont)
BRN (COMMON)
C
VIO (STEP 2)
W1
WHT ( STEP 1)
W1

BLK CONTACTOR 2
TO
UNIT POWER YEL BRN
WIRING YEL YEL

FUSE BLOCK CONTACTOR 1


EL 1 AUTO-LIMIT
F3 YEL BRN BLK
EL 2
L2 F4 YEL YEL YEL BLK
EL 3
L1 F1 BLK YEL YEL BLK
F2 BLK

Typical Electric Heater Diagram

50ZP
Selection Procedure
I DETERMINE COOLING AND HEATING Enter the Accessory Electric Heater table on page 16
REQUIREMENTS AT DESIGN CONDITIONS. 208/230, single-phase, 50ZP036 unit. The 5-kW heater at
Given: 240v most closely satisfies the heating required to
Required Net Cooling Capacity (TC) . . . . . . 34,000 Btuh calculate kW at 230 V, multiply the heater kW by
Sensible Net Heat Capacity (SHC) . . . .. . . . . 25,000 Btuh multiplication factor 0.92 found in the Multiplication
Required Net Heating Capacity. . . . . . .. . . . . 15,000 Btuh Factors table on page 16.
Outdoor Entering-Air Temperature . . ... . . . . . . . . . .95°F 5 kW x 0.92 = 4.6 kW
Indoor Entering-Air Temperature. . . .80°F edb; 67°F ewb 4.6 kW x 3414 Btuh/kW = 15,704 Btuh
Indoor-Air Quantity . . . . . . . . . . . . . . . . . . . . . . 1200 cfm IV DETERMINE FAN SPEED AND POWER
External Static Pressure . . . . . . . . . . . . . . . . . .0.20 in. wg REQUIREMENTS AT DESIGN CONDITIONS.
Electrical Characteristics (V-Ph-Hz) . . . . . . . . . 230-1-60 Before entering the air delivery tables, calculate the total
II SELECT UNIT BASED ON REQUIRED COOLING static pressure required. From the given, Filter Pressure
CAPACITY. Drop table, the Accessory Electric Heat Pressure Drop
Enter Cooling Capacities table at condenser entering table, and the Wet Coil Pressure Drop table, find:
temperature of 95°F, indoor air entering at 1200 cfm and External static pressure 0.20 in. wg
67°F ewb. The 50ZP036 unit provides a total cooling Filter 0.10 in. wg
capacity of 35,500 Btuh and a sensible heat capacity of Electric Heat 0.13 in. wg
26,600Btuh. Wet Coil 0.09 in. wg
For indoor-air temperature other than 80°F edb, calculate Total static pressure 0.52 in. wg
sensible heat capacity correction, as required, using the
formula found in Note 3 following the Cooling Capacities Enter the table for Dry Coil Air Delivery — Horizontal
tables. Discharge. At 0.5 in. wg external static pressure and high
NOTE: Unit ratings are gross capacities. speed, the motor delivers 1297 cfm. Interpolating for 0.52
III SELECT ELECTRIC HEAT. in. wg delivers 1276 cfm, which satisfies the job
The required heating capacity is 15,000 Btuh (given). requirements.
Determine the electric heat capacity in kW.
15,000 Btuh = 3.8 kW of heat required
3414 Btuh/kW

13
Electrical data
Voltage
Nominal Compressor OFM IFM ELECTRIC HEATER POWER SUPPLY
50ZP Range
Unit Voltage
Nominal
V-Ph-Hz MIN Max RLA LRA FLA FLA FLA MCA MOCP
kW*
--/-- --/-- 21.6/21.6 35/35
220-1-60 187 254 13.5 82 1.50 2.80 3.8/5.0 18.1/20.8 26.1/29.5 35/35
7.5/10.0 36.1/41.7 48.6/55.6 50/60
036
--/-- --/-- 16.7/16.7 25/25
220-3-60 187 254 9.6 70 1.50 2.80 3.8/5.0 10.4/12.0 17.8/19.9 25/25
7.5/10.0 20.8/24.1 31.9/36.2 35/40
--/-- --/-- 25.9/25.9 40/40
220-1-60 187 254 17 97 1.50 2.80 3.8/5.0 18.1/20.8 27.4/29.5 40/40
7.5/10.0 36.1/41.7 48.6/55.6 50/60
042
--/-- --/-- 17.7/17.7 25/25
220-3-60 187 254 10.4 78 1.50 2.80 3.8/5.0 10.4/12.0 17.9/18.5 25/25
7.5/10.0 20.8/24.1 29.6/33.6 30/35
--/-- --/-- 28.5/28.5 45/45
220-1-60 187 254 18.7 110 1.50 3.20 3.8/5.0 18.1/20.8 27.4/29.5 45/45
7.5/10.0 36.1/41.7 48.6/85.6 50/60
048
--/-- --/-- 19.4/19.4 30/30
220-3-60 187 254 11.4 78 1.50 3.20 3.8/5.0 10.4/12.0 21.1/21.1 30/30
7.5/10.0 20.8/24.1 31.3/35.3 35/40
50ZP

--/-- --/-- 41.02/41.02 60/60


220-1-60 187 254 26.5 178 1.42 5.76 3.8/5.0 18.1/20.8 42.4/42.2 60/60
7.5/10.0 36.1/41.7 54.25/61.25 60/70
060
--/-- --/-- 26.65/26.65 40/40
220-3-60 187 254 15 114 1.42 5.76 3.8/5.0 10.4/12.0 29.7/29.7 40/40
7.5/10.0 20.8/24.1 33.8/37.8 35/40
EXAMPLE: Supply voltage is 460-3-60.
AB = 452 v
LEGEND BC = 464 v
FLA — Full Load Amps AC = 455 v
LRA — Locked Rotor Amps
MCA — Minimum Circuit Amps
®
Average Voltage = 452 + 464 + 455
3
MOCP — Maximum Overcurrent Protection
RLA — Rated Load Amps = 1371
3
*Heater capacity (KW) based on heater voltage of 208v, 240v, & 480v.
If power distribution voltage to unit varies from rated heater voltage, = 457
heater KW will vary accordingly. Determine maximum deviation from average voltage.
(AB) 457 452 = 5 v
NOTES: (BC) 464 457 = 7 v
1. In compliance with NEC (National Electrical Code) requirements (AC) 457 455 = 2 v
for multimotor and combination load equipment (refer to NEC Maximum deviation is 7 v.
Articles 430 and 440), the overcurrent protective device for the
unit shall be Power Supply fuse . The CGA (Canadian Gas Determine percent of voltage imbalance.
Association) units may be fuse or circuit breaker. 7
2. Minimum wire size is based on 60 C copper wire. If other than % Voltage Imbalance = 100 x
60 C wire is used, or if length exceeds wire length in table, 457
determine size from NEC. = 1.53%
3. Unbalanced 3-Phase Supply Voltage
Never operate a motor where a phase imbalance in supply volt- This amount of phase imbalance is satisfactory as it is below the
age is greater than 2%. Use the following formula to determine maximum allowable 2%.
the percentage of voltage imbalance.
% Voltage imbalance IMPORTANT: If the supply voltage phase imbalance is
more than 2%, contact your local electric utility company
max voltage deviation from average voltage immediately.
= 100 x
average voltage

14
Operating sequence
COOLING HEATING
NOTE: With the FAN switch in the ON position, 24 v is When power is supplied to unit, transformer (TRAN) is
supplied to the time-delay relay (TDR) through the G terminal energized. On units with crankcase heater (CH), heater is also
on the thermostat. This voltage energizes the coil of the relay, energized.
closing the normally-open set of contacts which provide With thermostat set to call for heating, sequence of operation is
continuous power to the indoor (evaporator) fan motor (IFM). as follows:
Moving the FAN switch back to the AUTO position (providing
there is not a call for cooling) deenergizes the TDR (when On a call for heat, circuit R-W and R-G are made through first-
applicable) which deenergizes the IFM after a 30-second delay. stage thermostat bulb. If accessory electric heaters are used, a
The FAN switch in AUTO position cycles upon a call for relay is energized, bringing on first stage of supplemental
cooling. electric heat and fan. When thermostat is satisfied, contacts
open, deenergizing relay (on all units) and time-delay relay (on
On a call for cooling, 24 v is supplied to the compressor units equipped with time-delay relay). Heaters deenergize, and
contactor (C) and TDR simultaneously through the Y and G evaporator fan stops after a 30-second time delay (on units
terminals of the thermostat, respectively. On units with a equipped with time-delay relay).
compressor TDR, there is a built-in, 5-minute (±45 seconds)
delay between compressor starts. Energizing the contactor
closes the normally-open set of contacts supplying power to
both the compressor and outdoor (condenser) fan motor (OFM).

50ZP
Energizing the TDR closes the normally-open set of contacts
providing power to the IFM. On the loss of the call for cooling,
24 v is removed from both the Y and G terminals of the
thermostat (providing the FAN switch is in the AUTO position),
deenergizing both the compressor and TDR and opening both
the contacts supplying power to compressor/OFM. IFM has a
30-second delay.

Typical Installation
INDOOR
THERMOSTAT

RETURN
AIR

FROM
TOP COVER POWER
SOURCE

POWER AND
LOW-VOLTAGE DISCONNECT
ENTRY PER NEC*
(UNIT AND
COMPOSITE ELECTRIC
RUST-PROOF HEATER)
BASEPAN
Power Wiring CONDENSATE
Control Wiring DRAIN
CONNECTION

Condenser Airflow *Separate disconnect per NEC


(National Electrical Code) required
for electric heater when single-
Evaporator Airflow point conection is not used. C00008

15
APPLICATION DATA
ACCESSORY ELECTRIC HEATERS
ODS CATALOG NOMINAL USED WITH SIZES
ORDERING NO. CAPACITY (kW) 036 042 048 060
ELECTRIC HEATERS (208/230 — SINGLE PHASE — 60 Hz)
CPHEATER026A00 5.0 X X X X
CPHEATER039A00 10.0 X X X X
ELECTRIC HEATERS (208/230 — 3 PHASE — 60 Hz)
CPHEATER029A00 5.0 X X X X
CPHEATER030A00 10.0 X X X X
LEGEND
ODS — Order Distribution System
NOTE: Electric heaters are rated at 240 v. Refer to Multiplication Factors table below for voltages in other applications.

MULTIPLICATION FACTORS
HEATER Kw VOLTAGE DISTRIBUTION
MULTIPLICATION FACTOR
RATING V/3/60
200 0.69
208 0.75
240
230 0.92
240 1.00
Example: 10.0 kW (at 240v) heater on 208 v
= 10.0 × 0.75 (mult factor).
= 7.5 kw capacity at 208 v

Engineers’ Specification Guide


50ZP

GENERAL: Furnish and install outdoor package, electrically Condenser coils shall have aluminum-plate fins mechanically
controlled, air conditioner utilizing a hermetic compressor bonded to seamless copper tubes with all joints brazed.
for cooling duty. Unit shall discharge supply air horizontally.
Tube sheet openings shall be belled to prevent tube wear.
Nominal unit electrical characteristics shall be ______ v, EVAPORATOR SECTION: Fan shall be 2- or 3-speed with
______ ph, 60 Hz. The unit shall be capable of satisfactory direct drive motor as shown on the equipment drawings.
operation within voltage limits of ______ v to ______ v. Unit
power wiring shall enter unit cabinet at a single location. Fan wheel shall be made from steel, be double-inlet type with
Separate power supply shall not be required for electric heat. forward-curved blades with a corrosion-resistant finish and
dynamically balanced.
COOLING CAPACITY: Total cooling capacity of the unit
shall be _____ Btuh or greater, and sensible capacity shall be Evaporator coils shall have aluminum-plate fins mechanically
______ Btuh or greater at conditions of ______ cfm indoor air bonded to seamless copper tubes with all joints brazed.
entering unit at ______F dry bulb, _____ F wet bulb and Tube sheet openings shall be belled to prevent tube wear.
outdoor entering air of ______F dry bulb. Total design
conditions shall be a minimum of ______ Btuh/Watt. The unit MOTORS: Compressor motors shall be of the refrigerant-
shall be capable of cooling operation down to 40 F outdoor cooled type with line break thermal and current overload
as shipped from the factory. protection.

CABINET: Unit cabinet shall be constructed of phosphated, All fan motors shall have permanently lubricated bearings, and
bonderized, zinc-coated, prepainted steel. Basepan shall be inherent automatic reset thermal overload protection.
made of a single-piece non-corrosive, composite material. Condenser fan motor shall be open drip-proof.
Evaporator-fan compartment interior cabinet surfaces shall be REFRIGERANT SYSTEM: Refrigerant system shall include
insulated with a minimum 1/2-in. thick, flexible non-fiberglass fixed orifice metering system.
insulation, coated on the air side with aluminum foil.
CONTROLS: Unit shall be complete with self-contained low-
Cabinet panels shall be easily removable for servicing. voltage control circuit.
APPROVALS:
COMPRESSOR: Compressor shall be fully hermetic type All wiring shall be in accordance with NEC.
with internal and external vibration isolation. Unit shall be rated in accordance with AHRI Standard
CONDENSER SECTION: Condenser fan shall be of the Cabinet insulation shall conform to ASHRAE No. 62P.
direct-driven propeller type with aluminum blades, riveted to Insulation and adhesive shall meet NFPA 90A requirements for
corrosion-resistant steel spiders, and shall be dynamically flame spread and smoke generation.
balanced and discharge air horizontally or vertically upwards.
Unit shall have a sloped drain pan that conforms to ASHRAE
Standard 62-89.

Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations

2011 50ZP -04 PD