The 50ZP is a package air conditioner for manufactured housing, residential, and light commercial applications.
The 50ZP unit design is the result of our firm commitment to the development of the finest air conditioners that
modern technology can offer. The 50ZP unit is built in one basic cabinet size and features rectangular duct
configuration on sizes 036-060.
Features/Benefits
FACTORY-ASSEMBLED PACKAGE is a compact, fully
self-contained, electric cooling unit with horizontal supply
and return ducts. The 50ZP units are available in a variety
of standard cooling sizes with voltage options to meet
residential and light commercial requirements. Unit
installs easily on a ground level pad.
EASY TO INSTALL
50ZP units are small, compact, and easy to handle.
Every 50ZP unit has an identical 32 x 51-in. footprint to
make planning simple. The concise design uses less
sheet metal and makes the 50ZP units lighter than other
units. The unit can be easily positioned on the jobsite
with the hand-holds built into the unit basepan. Drop-in
cartridge style heaters are utilized to minimize
installation time. The 50ZP unit was designed with
potential safety hazards in mind; with no sharp edges or
corners which could injure a worker.
50ZP-04 PD 2011
The watertight construction and corrosion- performance level can reduce cooling expenses Controls — Contains high- and
resistant finish of the 50ZP unit will by as much as 25% compared to older cooling low-pressure switches to protect the unit from
keep it looking like new for years. The paint equipment. A high-eficiency, multi-speed running at unsuitable pressures. Provides
treatment process ensures quality protection blower motor system ensures quality additional safety features when needed.
against the elements. performance with most duct systems. The
computer-designed blower wheel is balanced Solid-State Time Guard® Device —
INDOOR AIR QUALITY is designed into the for quiet operation. Provides a 5-minute delay in compressor
50ZP units. A sloped drain pan minimizes the operation between cooling cycles. Prevents
amount of standing water inside the unit, which DURABLE, DEPENDABLE,
COMPRESSORS are designed for high compressor short cycling when rapid
limits mold and mildew growth. The drain pan
efficiency. Each compressor is hermetically compressor cycles may be a problem.
is made of a rust-proof material and will not
deteriorate or release foreign matter into the sealed against contamination to help promote FIELD-INSTALLED ACCESSORY
airstream. longer life and dependable operation. Vibration DESCRIPTION AND USAGE
isolation provides quiet operation. Compressors
LIGHTWEIGHT, COMPACT have internal high-pressure and overcurrent Electric Heater — Heater module slides into
CONSTRUCTION is ideal for manufactured protection. keyed mounting slots in the fan inlet. Heater
housing and residential applications. The 50ZP sizes range from 5.0 to 20.0 kW. Design allows
unit is one of the lightest, most compact DIRECT-DRIVE MULTISPEED, PSC
for single-point supply for entire unit. Heaters
packaged units ever designed. It’s light weight (PERMANENT SPLIT CAPACITOR)
provide heating capability when required.
(250 lbs for the 50ZP 036 unit) makes the unit BLOWER MOTOR is standard on all models.
easier to handle. The low height keeps ductwork Direct-drive, PSC condenser-fan motors are Crankcase Heater — Warms crankcase oil to
connections to a minimum and makes units less designed to help reduce energy consumption reduce refrigerant migration and ensure proper
visible. and provide for cooling operation down to 40 F. compressor lubrication. (Field Installed).
REFRIGERANT SYSTEM is designed to Outdoor Thermostat — Accessory provides
The 50ZP units utilize a structural beam design
provide dependability. Liquid refrigerant control when outdoor-air temperature falls
to form the four sides of the cabinet. Only 12
strainers are used to promote clean, unrestricted below set point. Helps to bring second stage of
different pieces of sheet metal are used in the
operation. Each unit leaves the factory with a 2-stage electric heater on line.
unit construction to simplify the unit for greater
reliability. full refrigerant charge. Refrigerant service
50ZP
2
MODEL NUMBER NOMENCLATURE
50ZP 036 - 5 1 1 S
50ZP
5- 208/230 -3-60
Physical Data
50ZP UNIT SIZE 036 042 048 060
Operating Weight (lb) 250 297 310 350
Compressor Type Reciprocating
Refrigerant R-22
Charge (lb) 4.7 4.4 6.1 7.5
Refrigerant Metering Device Acutrol TM System
Condenser Coil Copper Tubes, Aluminum Plate Fins
Rows – Fins/in. 1 – 17 1 – 17 2 – 17 2 – 17
Total Face Area (sq ft) 6.2 11.1 8.6 10.7
Condenser Motor Propeller
Condenser Cfm 2200 2800 2800 3000
Nominal Rpm 1100 1100 1100 1100
Motor Hp (Rpm) ¼ ¼ ¼ ¼
Diameter (in.) 20 20 20 20
Evaporator – Fan Motor Direct Drive
Blower Motor Size (in.) 10 × 8 10 × 9 10 × 9 10 × 10
Nominal Cfm 1200 1400 1600 2000
Rpm Range 800 – 1000 800 – 1000 900 - 1075 950 – 1100
Number of Speeds 3 3 2 2
Factory Speed Setting Low Med Low Low
Motor Hp ½ ½ ¾ 1
Connecting Duct Sizes Square
Supply Air (in.) 13.9 × 10.9 13.9 × 13.9
Return Air (in.) 13.9 × 11.5 13.9 × 27.8
Field- Supplied Return Air Filter*
24 × 24 × 1 24 × 24 × 1 24 × 30 × 1 24 × 30 × 1
Throwaway
Required filter sizes shown are based on the AHRI (Air conditioning, Heating & Refrigeration Institute) rated airflow at a
velocity of 300 ft/minute for throwaway type or 450 ft/minute fir high-capacity type.
Recommended filters are 1-in. think.
3
Dimensional drawings — 50ZP 036
50ZP
D C
A B
4
Dimensional drawings — 50ZP 042
50ZP
D C
A B
5
Dimensional drawings — 50ZP 048
50ZP
D C
A B
6
Dimensional drawings — 50ZP 060
50ZP
D C
A B
7
Cooling capacities (Gross)
50ZP036
EVAPORATOR CONDENSER AIR TEMPERATURE (F)
AIR 85 95 105 115 125
F Capacity MBtuh Compressor Capacity MBtuh Compressor Capacity MBtuh Compressor Capacity MBtuh Compressor Capacity MBtuh Compressor
Cfm BF
Ewb Total Sensible kW Total Sensible kW Total Sensible kW Total Sensible kW Total Sensible kW
72 39.8 19.9 3.65 37.9 19.2 3.83 35.9 18.6 4.02 33.8 18 4.20 31.90 17.20 4.69
1050 0.08 67 36.7 25.5 3.53 34.7 24.8 3.71 32.7 24 3.88 30.7 23.4 4.05 28.10 21.26 4.41
62 33.3 30.6 3.42 31.5 29.7 3.59 29.6 28.7 3.75 27.8 27.7 3.91 23.70 23.69 4.26
72 40.9 21 3.74 38.8 20.4 3.92 36.8 19.9 4.11 34.3 19 4.27 32.80 18.53 4.73
1200 0.10 67 37.5 27.3 3.61 35.5 26.6 3.79 33.4 25.8 3.96 31.4 25.1 4.14 29.10 23.16 4.46
62 34.3 32.8 3.15 32.4 31.8 3.67 30.6 30.6 3.84 29 29 4.03 25.30 25.35 4.33
72 41.3 21.9 3.80 39.4 21.5 3.99 37.2 20.7 4.17 35 20.1 4.36 33.50 19.70 4.78
1350 0.11 67 38.4 29.2 3.70 36.2 28.3 3.87 34.1 27.5 4.03 32 26.8 4.21 30.10 25.27 4.53
62 35.1 34.8 3.59 33.4 33.4 3.76 31.8 31.8 3.94 30.1 30.1 4.13 27.30 26.17 4.30
50ZP042
EVAPORATOR CONDENSER AIR TEMPERATURE (F)
AIR 85 95 105 115 125
F Capacity MBtuh Compressor Capacity MBtuh Compressor Capacity MBtuh Compressor Capacity MBtuh Compressor Capacity MBtuh Compressor
Cfm BF
Ewb Total Sensible kW Total Sensible kW Total Sensible kW Total Sensible kW Total Sensible kW
72 47.5 23.4 4.19 45 22.5 4.39 42.4 21.6 4.60 39.7 20.7 4.81 36.40 20.35 5.20
1225 0.11 67 40.3 26.9 3.89 39.7 27.4 4.17 37.8 27 4.40 35.5 26.4 4.62 31.80 26.31 4.90
62 37.6 33.1 3.81 36 32.8 4.03 34.1 32.1 4.25 31.8 31.1 4.45 29.10 29.10 4.70
72 48.7 24.7 4.28 46 23.8 4.49 43.4 22.9 4.70 40.5 22 4.89 37.60 22.06 5.24
1400 0.12 67 39.8 27.1 3.92 41.7 28.9 4.24 38.6 28.9 4.49 36.3 28.3 4.71 32.80 28.69 4.96
50ZP
62 38.2 34.6 3.88 36.9 34.9 4.13 34.9 34.3 4.34 33 33 4.56 30.90 30.90 4.82
72 49.6 26 4.37 46.8 25.1 4.58 44 24.1 4.78 41.2 23.2 4.98 38.50 23.65 5.27
1575 0.14 67 39.1 26.9 3.95 40.4 29.9 4.30 39.3 30.6 4.57 37.1 30.2 4.80 33.90 31.04 5.02
62 38 35.1 3.93 37.6 36.6 4.21 35.9 35.8 4.44 34.2 34.2 4.68 32.60 32.60 4.92
LEGEND 3. The sensible heat capacity is based on 80°F edb temperature of air
BF — Bypass Factor entering indoor coil.
Ewb — Entering Wet Bulb Below 80°F edb, subtract (corr factor x cfm) from the sensible heat
Idb — Leaving Dry Bulb capacity.
Iwb — Leaving Wet Bulb Above 80°F edb, add (corr factor x cfm) to the sensible heat
MBtuh — 1000 Btuh (gross) capacity. Correction Factor = 1.10 x (1–BF) x (edb – 80).
NOTES:
1. Direct interpolation is permissible. Do not extrapolate.
2. The following formulas may be used:
sensible capacity (MBtuh x 1000)
t = t ⴚ
ldb edw 1.10 x cfm
t lwb = Wet-bulb temperature corresponding to enthalpy of air leaving
indoor coil (h lwb )
total capacity (MBtuh x 1000)
hlwb = hewbⴚ
4.5 cfm
Where: h ewb = Enthalpy of air entering indoor coil
8
Cooling capacities (cont)
50ZP048
EVAPORATOR CONDENSER AIR TEMPERATURE (F)
AIR 85 95 105 115 125
F Capacity MBtuh Compressor Capacity MBtuh Compressor Capacity MBtuh Compressor Capacity MBtuh Compressor Capacity MBtuh Compressor
Cfm BF
Ewb Total Sensible kW Total Sensible kW Total Sensible kW Total Sensible kW Total Sensible kW
72 46.8 22.5 4.42 48.5 24.6 4.88 47.3 24.9 5.23 42.6 44.4 24.1 41.80 23.48 6.01
1400 0.06 67 45.6 31.2 4.41 45.4 32.6 4.77 42.9 31.9 5.03 38.1 39.9 31 36.50 29.77 5.72
62 43.5 39.6 4.34 41.4 39.2 4.60 38.9 38.2 4.85 34.6 36.4 36.4 33.00 33.00 5.49
72 45.4 22 4.42 48.1 24.3 4.89 48 26.1 5.33 42.9 45.1 25.6 43.00 25.13 6.83
1600 0.07 67 44.4 30.6 4.42 47.7 34.3 4.86 43.7 34.2 5.14 38.5 40.7 33.4 37.80 32.42 5.79
62 43.7 41.1 4.42 42.3 41.7 4.72 40.2 40.2 4.98 35.7 37.9 37.9 35.10 35.10 5.60
72 44.1 22.4 4.44 46.2 24 4.90 47.7 26.7 5.38 43.2 45.8 27 44.00 26.74 6.11
1800 0.08 67 43.3 30.2 4.43 45.3 34.7 3.90 44.3 36.3 5.25 38.7 41.3 35.6 38.90 34.83 5.85
62 42.7 40 4.44 43.1 43 4.83 41.5 41.4 5.12 36.7 39.3 39.2 36.90 36.90 5.69
50ZP060
EVAPORATOR CONDENSER AIR TEMPERATURE (F)
AIR 85 95 105 115 125
F Capacity MBtuh Compressor Capacity MBtuh Compressor Capacity MBtuh Compressor Capacity MBtuh Compressor Capacity MBtuh Compressor
Cfm BF
Ewb Total Sensible kW Total Sensible kW Total Sensible kW Total Sensible kW Total Sensible kW
72 68.1 33.4 6.22 67.6 34 6.78 64.3 33 7.22 60.5 31.8 7.60 54.8 30.4748 8.16
50ZP
1750 0.06 67 64.8 44.3 6.16 61.2 43.1 6.55 57.9 41.6 6.87 54.3 40.4 7.27 47.6 38.51 7.59
62 57.1 50.8 5.80 55 50.4 6.21 52.1 49.5 6.60 48.9 48.2 6.97 42.9 42.9 8.40
72 66.5 33.42 6.23 68.4 35.52 6.90 65.62 35.12 7.38 61.6 33.62 7.75 56.32 32.912 8.16
2000 0.07 67 66.1 47.22 6.30 62.1 46.32 6.72 58.82 44.32 7.01 55.6 43.52 7.43 49.32 41.928 7.70
62 55.9 50.52 5.82 56.1 53.82 6.35 53.52 52.92 6.76 50.8 50.72 7.17 45.72 45.72 7.40
72 64.8 32.8 6.23 67.9 36.1 6.95 66.5 36.8 7.51 62.5 35.4 7.88 57.6 34.92 8.21
2250 0.08 67 67.3 50.1 6.43 63.9 49.3 6.86 59.6 46.8 7.14 56.4 46.5 7.57 50.9 45.224 8.96
62 54.4 49.7 5.84 56.7 55.9 6.47 55 54.9 6.93 52.6 52.6 7.37 48.2 48.2 7.56
LEGEND 3. The sensible heat capacity is based on 80°F edb temperature of air
BF — Bypass Factor entering indoor coil.
Ewb — Entering Wet Bulb Below 80°F edb, subtract (corr factor x cfm) from the sensible heat
Idb — Leaving Dry Bulb capacity.
Iwb — Leaving Wet Bulb Above 80°F edb, add (corr factor x cfm) to the sensible heat
MBtuh — 1000 Btuh (gross) capacity. Correction Factor = 1.10 x (1–BF) x (edb – 80).
NOTES:
1. Direct interpolation is permissible. Do not extrapolate.
2. The following formulas may be used:
sensible capacity (MBtuh x 1000)
t = t ⴚ
ldb edw 1.10 x cfm
t lwb = Wet-bulb temperature corresponding to enthalpy of air leaving
indoor coil (h lwb )
total capacity (MBtuh x 1000)
hlwb = hewbⴚ
4.5 cfm
Where: h ewb = Enthalpy of air entering indoor coil
9
WET COIL PRESSURE DROP
UNIT SIZE AIRFLOW PRESSURE DROP
50ZP (cfm) (in. wg)
1000 0.04
1200 0.05
036
1400 0.07
1600 0.08
1000 0.04
1200 0.05
042
1400 0.07
1600 0.08
1400 0.07
048 1600 0.08
1800 0.09
1700 0.07
1800 0.08
060
2100 0.09
2300 0.10
HEATER CFM
kW 600 800 1000 1200 1400 1600 1800 2000 2200
5 – 20 0.06 0.08 0.10 0.13 0.15 0.18 0.20 0.23 0.25
50ZP
11
Typical wiring schematic — 208/230-3-60
50ZP
12
Typical field wiring (cont)
BRN (COMMON)
C
VIO (STEP 2)
W1
WHT ( STEP 1)
W1
BLK CONTACTOR 2
TO
UNIT POWER YEL BRN
WIRING YEL YEL
50ZP
Selection Procedure
I DETERMINE COOLING AND HEATING Enter the Accessory Electric Heater table on page 16
REQUIREMENTS AT DESIGN CONDITIONS. 208/230, single-phase, 50ZP036 unit. The 5-kW heater at
Given: 240v most closely satisfies the heating required to
Required Net Cooling Capacity (TC) . . . . . . 34,000 Btuh calculate kW at 230 V, multiply the heater kW by
Sensible Net Heat Capacity (SHC) . . . .. . . . . 25,000 Btuh multiplication factor 0.92 found in the Multiplication
Required Net Heating Capacity. . . . . . .. . . . . 15,000 Btuh Factors table on page 16.
Outdoor Entering-Air Temperature . . ... . . . . . . . . . .95°F 5 kW x 0.92 = 4.6 kW
Indoor Entering-Air Temperature. . . .80°F edb; 67°F ewb 4.6 kW x 3414 Btuh/kW = 15,704 Btuh
Indoor-Air Quantity . . . . . . . . . . . . . . . . . . . . . . 1200 cfm IV DETERMINE FAN SPEED AND POWER
External Static Pressure . . . . . . . . . . . . . . . . . .0.20 in. wg REQUIREMENTS AT DESIGN CONDITIONS.
Electrical Characteristics (V-Ph-Hz) . . . . . . . . . 230-1-60 Before entering the air delivery tables, calculate the total
II SELECT UNIT BASED ON REQUIRED COOLING static pressure required. From the given, Filter Pressure
CAPACITY. Drop table, the Accessory Electric Heat Pressure Drop
Enter Cooling Capacities table at condenser entering table, and the Wet Coil Pressure Drop table, find:
temperature of 95°F, indoor air entering at 1200 cfm and External static pressure 0.20 in. wg
67°F ewb. The 50ZP036 unit provides a total cooling Filter 0.10 in. wg
capacity of 35,500 Btuh and a sensible heat capacity of Electric Heat 0.13 in. wg
26,600Btuh. Wet Coil 0.09 in. wg
For indoor-air temperature other than 80°F edb, calculate Total static pressure 0.52 in. wg
sensible heat capacity correction, as required, using the
formula found in Note 3 following the Cooling Capacities Enter the table for Dry Coil Air Delivery — Horizontal
tables. Discharge. At 0.5 in. wg external static pressure and high
NOTE: Unit ratings are gross capacities. speed, the motor delivers 1297 cfm. Interpolating for 0.52
III SELECT ELECTRIC HEAT. in. wg delivers 1276 cfm, which satisfies the job
The required heating capacity is 15,000 Btuh (given). requirements.
Determine the electric heat capacity in kW.
15,000 Btuh = 3.8 kW of heat required
3414 Btuh/kW
13
Electrical data
Voltage
Nominal Compressor OFM IFM ELECTRIC HEATER POWER SUPPLY
50ZP Range
Unit Voltage
Nominal
V-Ph-Hz MIN Max RLA LRA FLA FLA FLA MCA MOCP
kW*
--/-- --/-- 21.6/21.6 35/35
220-1-60 187 254 13.5 82 1.50 2.80 3.8/5.0 18.1/20.8 26.1/29.5 35/35
7.5/10.0 36.1/41.7 48.6/55.6 50/60
036
--/-- --/-- 16.7/16.7 25/25
220-3-60 187 254 9.6 70 1.50 2.80 3.8/5.0 10.4/12.0 17.8/19.9 25/25
7.5/10.0 20.8/24.1 31.9/36.2 35/40
--/-- --/-- 25.9/25.9 40/40
220-1-60 187 254 17 97 1.50 2.80 3.8/5.0 18.1/20.8 27.4/29.5 40/40
7.5/10.0 36.1/41.7 48.6/55.6 50/60
042
--/-- --/-- 17.7/17.7 25/25
220-3-60 187 254 10.4 78 1.50 2.80 3.8/5.0 10.4/12.0 17.9/18.5 25/25
7.5/10.0 20.8/24.1 29.6/33.6 30/35
--/-- --/-- 28.5/28.5 45/45
220-1-60 187 254 18.7 110 1.50 3.20 3.8/5.0 18.1/20.8 27.4/29.5 45/45
7.5/10.0 36.1/41.7 48.6/85.6 50/60
048
--/-- --/-- 19.4/19.4 30/30
220-3-60 187 254 11.4 78 1.50 3.20 3.8/5.0 10.4/12.0 21.1/21.1 30/30
7.5/10.0 20.8/24.1 31.3/35.3 35/40
50ZP
14
Operating sequence
COOLING HEATING
NOTE: With the FAN switch in the ON position, 24 v is When power is supplied to unit, transformer (TRAN) is
supplied to the time-delay relay (TDR) through the G terminal energized. On units with crankcase heater (CH), heater is also
on the thermostat. This voltage energizes the coil of the relay, energized.
closing the normally-open set of contacts which provide With thermostat set to call for heating, sequence of operation is
continuous power to the indoor (evaporator) fan motor (IFM). as follows:
Moving the FAN switch back to the AUTO position (providing
there is not a call for cooling) deenergizes the TDR (when On a call for heat, circuit R-W and R-G are made through first-
applicable) which deenergizes the IFM after a 30-second delay. stage thermostat bulb. If accessory electric heaters are used, a
The FAN switch in AUTO position cycles upon a call for relay is energized, bringing on first stage of supplemental
cooling. electric heat and fan. When thermostat is satisfied, contacts
open, deenergizing relay (on all units) and time-delay relay (on
On a call for cooling, 24 v is supplied to the compressor units equipped with time-delay relay). Heaters deenergize, and
contactor (C) and TDR simultaneously through the Y and G evaporator fan stops after a 30-second time delay (on units
terminals of the thermostat, respectively. On units with a equipped with time-delay relay).
compressor TDR, there is a built-in, 5-minute (±45 seconds)
delay between compressor starts. Energizing the contactor
closes the normally-open set of contacts supplying power to
both the compressor and outdoor (condenser) fan motor (OFM).
50ZP
Energizing the TDR closes the normally-open set of contacts
providing power to the IFM. On the loss of the call for cooling,
24 v is removed from both the Y and G terminals of the
thermostat (providing the FAN switch is in the AUTO position),
deenergizing both the compressor and TDR and opening both
the contacts supplying power to compressor/OFM. IFM has a
30-second delay.
Typical Installation
INDOOR
THERMOSTAT
RETURN
AIR
FROM
TOP COVER POWER
SOURCE
POWER AND
LOW-VOLTAGE DISCONNECT
ENTRY PER NEC*
(UNIT AND
COMPOSITE ELECTRIC
RUST-PROOF HEATER)
BASEPAN
Power Wiring CONDENSATE
Control Wiring DRAIN
CONNECTION
15
APPLICATION DATA
ACCESSORY ELECTRIC HEATERS
ODS CATALOG NOMINAL USED WITH SIZES
ORDERING NO. CAPACITY (kW) 036 042 048 060
ELECTRIC HEATERS (208/230 — SINGLE PHASE — 60 Hz)
CPHEATER026A00 5.0 X X X X
CPHEATER039A00 10.0 X X X X
ELECTRIC HEATERS (208/230 — 3 PHASE — 60 Hz)
CPHEATER029A00 5.0 X X X X
CPHEATER030A00 10.0 X X X X
LEGEND
ODS — Order Distribution System
NOTE: Electric heaters are rated at 240 v. Refer to Multiplication Factors table below for voltages in other applications.
MULTIPLICATION FACTORS
HEATER Kw VOLTAGE DISTRIBUTION
MULTIPLICATION FACTOR
RATING V/3/60
200 0.69
208 0.75
240
230 0.92
240 1.00
Example: 10.0 kW (at 240v) heater on 208 v
= 10.0 × 0.75 (mult factor).
= 7.5 kw capacity at 208 v
GENERAL: Furnish and install outdoor package, electrically Condenser coils shall have aluminum-plate fins mechanically
controlled, air conditioner utilizing a hermetic compressor bonded to seamless copper tubes with all joints brazed.
for cooling duty. Unit shall discharge supply air horizontally.
Tube sheet openings shall be belled to prevent tube wear.
Nominal unit electrical characteristics shall be ______ v, EVAPORATOR SECTION: Fan shall be 2- or 3-speed with
______ ph, 60 Hz. The unit shall be capable of satisfactory direct drive motor as shown on the equipment drawings.
operation within voltage limits of ______ v to ______ v. Unit
power wiring shall enter unit cabinet at a single location. Fan wheel shall be made from steel, be double-inlet type with
Separate power supply shall not be required for electric heat. forward-curved blades with a corrosion-resistant finish and
dynamically balanced.
COOLING CAPACITY: Total cooling capacity of the unit
shall be _____ Btuh or greater, and sensible capacity shall be Evaporator coils shall have aluminum-plate fins mechanically
______ Btuh or greater at conditions of ______ cfm indoor air bonded to seamless copper tubes with all joints brazed.
entering unit at ______F dry bulb, _____ F wet bulb and Tube sheet openings shall be belled to prevent tube wear.
outdoor entering air of ______F dry bulb. Total design
conditions shall be a minimum of ______ Btuh/Watt. The unit MOTORS: Compressor motors shall be of the refrigerant-
shall be capable of cooling operation down to 40 F outdoor cooled type with line break thermal and current overload
as shipped from the factory. protection.
CABINET: Unit cabinet shall be constructed of phosphated, All fan motors shall have permanently lubricated bearings, and
bonderized, zinc-coated, prepainted steel. Basepan shall be inherent automatic reset thermal overload protection.
made of a single-piece non-corrosive, composite material. Condenser fan motor shall be open drip-proof.
Evaporator-fan compartment interior cabinet surfaces shall be REFRIGERANT SYSTEM: Refrigerant system shall include
insulated with a minimum 1/2-in. thick, flexible non-fiberglass fixed orifice metering system.
insulation, coated on the air side with aluminum foil.
CONTROLS: Unit shall be complete with self-contained low-
Cabinet panels shall be easily removable for servicing. voltage control circuit.
APPROVALS:
COMPRESSOR: Compressor shall be fully hermetic type All wiring shall be in accordance with NEC.
with internal and external vibration isolation. Unit shall be rated in accordance with AHRI Standard
CONDENSER SECTION: Condenser fan shall be of the Cabinet insulation shall conform to ASHRAE No. 62P.
direct-driven propeller type with aluminum blades, riveted to Insulation and adhesive shall meet NFPA 90A requirements for
corrosion-resistant steel spiders, and shall be dynamically flame spread and smoke generation.
balanced and discharge air horizontally or vertically upwards.
Unit shall have a sloped drain pan that conforms to ASHRAE
Standard 62-89.
Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations