1 of 5
Ethernet/IP Scanlist Setup
For Fanuc R-30iB Controller
Rev: A
2 of 5
Ethernet/IP Scanlist Setup
For Fanuc R-30iB Controller
Rev: A
NOTE: This will add all devices to the Scanlist with the default options. The options can be modified by right
clicking the connection and selecting Properties
3 of 5
Ethernet/IP Scanlist Setup
For Fanuc R-30iB Controller
Rev: A
5. (Optional) Adjust the Process Data Size for the IO-Link Master
5.1. In the Scanlist Configuration Window, Right Click on the IO-Link Master Connection and select Properties
5.3. The Process Port Data Size parameter can be lowered to reduce the total amount of Ethernet/IP data occupied
by the IO-Link data. NOTE: The default process data size is 32bytes per port (per IO-Link specification)
however most devices do not use the entire 32bytes.
5.4. If the Port Process Data Size is modified, the Input and Output Size entries on the Connection tab will need to
be changed to match. NOTE: The “(In xxx / Out xxx)” listed in the Port Process Data Size Parameter is provided
in bytes and need to be converted to words for the Input and Output Size Entries.
4 of 5
Ethernet/IP Scanlist Setup
For Fanuc R-30iB Controller
Rev: A
********************************************************************************************
Although the Data in the EIP stream is shifted as expected by the change in Process Data Size, the RSNetworx
Software will not allow a scanlist with 2 AL1222 units to be loaded due to the following error: