You are on page 1of 4

IS

: 694 - 2010
CM/L NO. 8200099709

RAYYAN CABLES PVT. LTD.


About Us
E-mail – marketing.rayyancables@gmail.com
Mobile - +91 8770384359
PROFILE
In the plateaus of Vindhya, a dream gave birth.

To innovate. To enlighten. To educate. To excel.

Presen ng, from the land of the white ger, your very own, Rayyan Cables. We at Rayyan Cables place utmost emphasis on quality.
Selec on of cable is a tough task; allow us to assist you - go for Rayyan.

We manufacture a range of specialized cables and are a crucial player in the domes c and retail segment. Since incep on, we have firmly
believed in the philosophy of constant growth, high quality and innova on. Customer sa sfac on has always been our priority.

A highly qualified, commi ed and experienced group of professionals strive to meet interna onal standards and cater to the needs of a
changing market. Our unblemished track record has earned us the patronage of leading industrial houses, project consultants and
architects.

FLAME RETARDANT PVC INSULATED SINGLE CORE UNSHEATHED


COPPER CABLES (UP TO 1100 VOLTS AC)
CONDUCTOR: The conductors, drawn from bright electroly c grade copper and annealed and bunched together.

INSULATION: The bunched conductors are insulated with specially formulated FR PVC compound with a high insula on resistance value.
The insula on process is carried out on modern high speed extrusion lines, which ensures high accuracy and consistency in performance.
Flame retardant proper es enable the cable to withstand overloads. The insula on is resistant to boiling water, steam and vapors. This
prevents ageing and cracking in kitchens, bathrooms, damp walls and chemical industries.

MARKING: The cables are printed with generic marking 'RAYYAN CABLES’.

COLORS: Red, Yellow, Blue, Black, Green and Grey.

PACKING: 90 Meters (apprx. 100 yards) pack in protec ve cartons.

Mul -stand flexible house wires with flame retardant proper es. Specially formulated insula on, with a high oxygen and
temperature index, enables the cable to withstand overloads preven ng electric mishaps. So, give yourself the promise of security
and supreme quality.

FR Flame Retardant
Test Specifica on Specified Values

Cri cal Oxygen Index ASTM-D 2863 Minimum 29%

Temperature Index ASTM-D 2863 Minimum 250 ⁰C

Size Dimensions and Ra ngs as per IS:694 specifica ons


Nominal Cross-Sec onal Number/Nominal Thickness of Overall Current Ra ng D.C Resistance

Areas of Conductor Dia of wires* [Nom.] insula on [Nom.] Diameter Max. Casing Concealed [Max.] at 20 ⁰C

Sq.mm Number/mm Mm Mm amps amps Ohm/km

0.75 24/0.2 0.6 2.8 11.00 10.00 26.0

1.00 32/0.2 0.6 3.0 16.00 15.00 18.1

1.50 30/0.25 0.6 3.8 22.00 18.00 12.1

2.50 50/0.25 0.7 4.0 28.00 25.00 7.41

4.00 56/0.3 0.8 4.8 42.00 35.00 4.95

*The number & diameter of conductor strands are for reference only and governed by conductor resistance.
*The above data is indica ve only and may be revised without prior informa on. Rayyan Cables will not be responsible for any damages arising out of incorrect
applica on of its product.
FLAME RETARDANT LOW SMOKE PVC INSULATED
SINGLE CORE UNSHEATHED COPPER CABLES
(UP TO 1100 VOLTS AC)

CONDUCTOR: The conductors, drawn from bright electroly c grade copper (99.99% purity) and annealed and bunched together.

INSULATION: The bunched conductors are insulated with specially formulated Flame Retardant Low Smoke Compound. During a fire situa on, the FR-
LSH compound restricts the spread of flame. The smoke emission is also minimal.

MARKING: The cables are printed with generic marking 'Rayyan - LSH'.

COLORS: Red, Yellow, Blue, Black, Green and Grey.

PACKING: 90 Meters (apprx. 100 yards) pack in protec ve cartons.

Our innova ve offering Rayyan - LSH is ideal for wiring solu ons in mul -storied buildings, hotels, hospitals, commercial establishments and residen al
complexes. It is shielded by a specially formulated flame retardant PVC compound. During fire, ordinary PVC emits black smoke and toxic fumes which
are acidic in nature. This impairs visibility and hampers rescue opera ons. This insula on retards spread of fire and emits minimum smoke and toxic
gases. Thereby reducing the risk of injury. As always, your safety is our guarantee; go with Rayyan Cables.

Rayyan - LSH - FRLS Flame Retardant Low Smoke


Test Specifica on Specified Values

Cri cal Oxygen Index ASTM-D 2863 Minimum 29%

Temperature Index ASTM-D 2863 Minimum 250 ⁰C

Acid Gas Genera on IEC 60754-1 Maximum 20%

Smoke Density Ra ng ASTM-D 2843 Maximum 60%

Size Dimensions and Ra ngs as per IS:694 specifica ons


Nominal Cross-Sec onal Number/Nominal Thickness of Overall Current Ra ng D.C Resistance

Areas of Conductor Dia of wires* [Nom.] insula on [Nom.] Diameter Max. Casing Concealed [Max.] at 20 ⁰C

Sq.mm Number/mm Mm Mm amps amps Ohm/km

0.75 24/0.2 0.6 2.8 11.00 10.00 26.0

1.00 32/0.2 0.6 3.0 16.00 15.00 18.1

1.50 30/0.25 0.6 3.8 22.00 18.00 12.1

2.50 50/0.25 0.7 4.0 28.00 25.00 7.41

4.00 56/0.3 0.8 4.8 42.00 35.00 4.95

6.00 84/0.3 0.8 6.4 52.00 46.00 3.30

*The number & diameter of conductor strands are for reference only and governed by conductor resistance.
*The above data is indica ve only and may be revised without prior informa on. Rayyan Cables will not be responsible for any damages arising out of incorrect applica on of
its product.
Marketed By:

RAYYAN CABLES PVT. LTD.


West Udyog Vihar, Industrial Area, Chorhata, REWA, MP – 486006
E-mail – marke ng.rayyancables@gmail.com
Mobile - +91 8770384359

You might also like