You are on page 1of 1

2 1

5200
JOINT SEALANT DEPTH ACCORDING TO
12 MANUFACTURER REQUIREMENTS
A B C (HYBRIFLEX-LM OR SIMILAR APPROVED)

5
250 250
10200 235 235
2000 3099 4998 102 4.900 500 x 200 DOWNSTAND BEAM BRICK OR
RC SLAB
101 1899 8200 CONCRETE

250
500
WALL

250
815 302

800
200 200
300 455 261 38 MESH REF 395
720 LAP MINIMUM
40 COVER

397
C1
COLUMN C1 COLUMN C1
1

4900
2400
WALL 3
BOND BREAKING COMPOUND OR TAPE

813
935
C1 C1
300

ISOLATION JOINTS JOINT FILLER:

935
200

WALL 1 150 THICK SURFACE BED NON-EXPANDABLE ASPHALT IMPREGNATED


WITH MESH REF 395 FIBRE BOARD
1.200

1345
900

900

900
413 1900 200 7185 455 360
SECTION B 200x400 DEEP BEAM SCALE 1:2

1200
200

WALL 2 ABOVE OPENING


300

600x300 DEEP BOND BREAKING COMPOUND


600x300 DEEP RC 600x300 DEEP RC
5200

RC STRIP NGL OR TAPE


STRIP FOOTING STRIP FOOTING
413 FOOTING
300 DEEP R.C. BASE NOTE: SAWED JOINT FACE
600x300 DEEP RC

1000
STRIP FOOTING 150mm thk SLAB:

WALL 3
CUT 37.5mm DEEP JOINT SEALANT DEPTH ACCORDING TO
3165

3165
10 MANUFACTURER REQUIREMENTS

300
(HYBRIFLEX-LM OR SIMILAR APPROVED)

397 397

5
SLAB DEEP

40
RC SLAB

2 A B C
3

397

1
4
600x300 DEEP RC 75
C1 C1 C1 10200
STRIP FOOTING 200 200
300 455 300 MESH REF 395
2000 8200 720 LAP MINIMUM
40 COVER
250 250
4.900 249 500 x 250 DOWNSTAND BEAM 248
BOND BREAKING COMPOUND

250250
BACKING CORD

500
INITIAL SAW CUT

800
SCALE 1:2

A B C
10200 COLUMN C1
COLUMN C1 COLUMN C1
TO BE CONFIRMED

4900
1099 2000 8200 1098

2400
101 1899 TO BE CONFIRMED TO BE CONFIRMED

VITAGRID TYPE 25x4,5


1.200 SERIES VE (GALVANISED) BOTTOM AND TOP MESH REF NO. 888.
PRECAST 720mm MINIMUM LAP LENGTH.
S.J. S.J. S.J. S.J. S.J. S.J. S.J.
STORMWATER 40mm COVER WITH EXPANSION
200x400 DEEP BEAM JOINTS AT 1000 CC
CHANNEL

1200
ABOVE OPENING
200 THK. R.C. WALL
I.J.
0.000
C1 C1 NGL
C1 NGL
S.J. S.J.

150
1 I.J.

300 600
I.J. I.J. 30

1000
600x300 DEEP
300 625

200 0

800
935

S.J. S.J. S.J. S.J. S.J. S.J. S.J. S.J. S.J. S.J. S.J. S.J. RC STRIP FOOTING
935

I.J. I.J. I.J. 1200x1200x300

300

300
DEEP RC BASE 600x300 DEEP 1200x1200x300
S.J. S.J. RC STRIP FOOTING DEEP RC BASE
300
900

900

1900 200 7185 455 360 413 517 167 450 150 6883 183 450 167 1215 397
SECTION B
S.J. S.J.

I.J. I.J. 200 THK. R.C. WALL


I.J.
5200

S.J. S.J.
30x30x5L (GALVANISED) WITH
I.J. I.J. I.J.
I.J. 20x5x125mm LONG LUGS @
S.J. FFL=23.425 S.J.
300c/c CAST INTO CONCRETE
S.J. BRICK WALL
S.J. VITAGRID TYPE 25x4,5 VARIES

1200
200x400 DEEP BEAM
S.J. S.J. SERIES VE (GALVANISED)
ABOVE OPENING - COLUMN LEGEND
DOWELLED INTO MARK MEMBER
S.J. S.J. R.C. WALL

200
C1 200x400 RC COLUMN
I.J. I.J. I.J.

200
S.J. S.J.
2 C1 C1 600x300 DEEP R.C.
C1

600
STRIP FOOTING FOOTING LEGEND

400
1000
S.J. S.J. S.J. S.J. S.J. S.J. S.J. S.J. S.J. S.J. S.J. S.J. S.J. S.J. S.J. S.J. S.J. S.J.
MARK MEMBER

800
300 DEEP R.C.

300 100 300


BASE F1 1200x1200x300 DEEP RC BASE

STORMWATER CHANNEL - REFER TO APRON DETAIL

200mm THK CONCRETE APRON WITH BOTTOM AND


TOP MESH REF NO. 888 720mm MINIMUM LAP
LENGTH. 40mm COVER WITH PRECAST
STORMWATER CHANNEL.

You might also like