You are on page 1of 697

Context of calculations

Selection of context

Weathers to use Parameters to use Obstructions to


Use Name for this study for this study use for this study

Yes Study

Open
MaterialBund, building and terrain
Toxic parameters
Modelling of mixturesTerrain and bund definition
Indoor toxic calculations

Type of pool Specify the


Type of terrain for substrate and downwind
Multi or pseudo-component modelling dispersion bunds building type

Types of terrain for Types of pool subs 0 Unselected

Open
ic parameters Dispersion
or toxic calculations Distances of interest

Building type
(downwind
building type) Distances of interest
m
Buildings\Building type

Open
Material

Specify volume
Use Study Folder Name Material inventory?

Yes Study Plant 1 P1-100-01_005mmP1-101 0 No


Yes Study Plant 1 P1-100-01_025mmP1-101 0 No
Yes Study Plant 1 P1-100-01_065mmP1-101 0 No
Yes Study Plant 1 P1-100-01_FBR P1-101 0 No
Yes Study Plant 1 P1-100-02_005mmP1-101 0 No
Yes Study Plant 1 P1-100-02_025mmP1-101 0 No
Yes Study Plant 1 P1-100-02_065mmP1-101 0 No
Yes Study Plant 1 P1-100-02_FBR P1-101 0 No
Yes Study Plant 1 P1-100-03_005mmP1-105 0 No
Yes Study Plant 1 P1-100-03_025mmP1-105 0 No
Yes Study Plant 1 P1-100-03_065mmP1-105 0 No
Yes Study Plant 1 P1-100-03_FBR P1-105 0 No
Yes Study Plant 1 P1-200-01_005mmP1-113 0 No
Yes Study Plant 1 P1-200-01_025mmP1-113 0 No
Yes Study Plant 1 P1-200-01_065mmP1-113 0 No
Yes Study Plant 1 P1-200-01_FBR P1-113 0 No
Yes Study Plant 1 P1-200-02_005mmP1-201 0 No
Yes Study Plant 1 P1-200-02_025mmP1-201 0 No
Yes Study Plant 1 P1-200-02_065mmP1-201 0 No
Yes Study Plant 1 P1-200-02_FBR P1-201 0 No
Yes Study Plant 1 P1-200-03_005mmP1-203 0 No
Yes Study Plant 1 P1-200-03_025mmP1-203 0 No
Yes Study Plant 1 P1-200-03_065mmP1-203 0 No
Yes Study Plant 1 P1-200-03_FBR P1-203 0 No
Yes Study Plant 1 P1-200-04_005mmP1-113 0 No
Yes Study Plant 1 P1-200-04_025mmP1-113 0 No
Yes Study Plant 1 P1-200-04_065mmP1-113 0 No
Yes Study Plant 1 P1-200-04_FBR P1-113 0 No
Yes Study Plant 1 P1-300-01_005mmP1-301 0 No
Yes Study Plant 1 P1-300-01_025mmP1-301 0 No
Yes Study Plant 1 P1-300-01_065mmP1-301 0 No
Yes Study Plant 1 P1-300-01_FBR P1-301 0 No
Yes Study Plant 1 P1-300-02_005mmP1-304 0 No
Yes Study Plant 1 P1-300-02_025mmP1-304 0 No
Yes Study Plant 1 P1-300-02_065mmP1-304 0 No
Yes Study Plant 1 P1-300-02_FBR P1-304 0 No
Yes Study Plant 1 P1-300-03_005mmP1-306 0 No
Yes Study Plant 1 P1-300-03_025mmP1-306 0 No
Yes Study Plant 1 P1-300-03_065mmP1-306 0 No
Yes Study Plant 1 P1-300-03_FBR P1-306 0 No

Open
Yes Study Plant 1 P1-300-04_005mmP1-309 0 No
Yes Study Plant 1 P1-300-04_025mmP1-309 0 No
Yes Study Plant 1 P1-300-04_065mmP1-309 0 No
Yes Study Plant 1 P1-300-04_FBR P1-309 0 No
Yes Study Plant 1 P1-400-01_005mmMeOH 0 No
Yes Study Plant 1 P1-400-01_025mmMeOH 0 No
Yes Study Plant 1 P1-400-01_065mmMeOH 0 No
Yes Study Plant 1 P1-400-01_FBR MeOH 0 No
Yes Study Plant 1 P1-400-02_005mmMeOH 0 No
Yes Study Plant 1 P1-400-02_025mmMeOH 0 No
Yes Study Plant 1 P1-400-02_065mmMeOH 0 No
Yes Study Plant 1 P1-400-02_FBR MeOH 0 No
Yes Study Plant 1 P1-400-03_005mmMeOH 0 No
Yes Study Plant 1 P1-400-03_025mmMeOH 0 No
Yes Study Plant 1 P1-400-03_065mmMeOH 0 No
Yes Study Plant 1 P1-400-03_FBR MeOH 0 No
Yes Study Plant 1 P1-1100-01_005m MeOH 0 No
Yes Study Plant 1 P1-1100-01_025m MeOH 0 No
Yes Study Plant 1 P1-1100-01_065m MeOH 0 No
Yes Study Plant 1 P1-1100-01_FBR MeOH 0 No
Yes Study Plant 1 P1-1100-02_005m MeOH 0 No
Yes Study Plant 1 P1-1100-02_025m MeOH 0 No
Yes Study Plant 1 P1-1100-02_065m MeOH 0 No
Yes Study Plant 1 P1-1100-02_FBR MeOH 0 No
Yes Study Plant 1 P1-700-01_005mmNG 0 No
Yes Study Plant 1 P1-700-01_025mmNG 0 No
Yes Study Plant 1 P1-700-01_065mmNG 0 No
Yes Study Plant 1 P1-700-01_FBR NG 0 No
Yes Study Plant 2 P2-100-01_005mmP2-010-04 0 No
Yes Study Plant 2 P2-100-01_025mmP2-010-04 0 No
Yes Study Plant 2 P2-100-01_065mmP2-010-04 0 No
Yes Study Plant 2 P2-100-01_FBR P2-010-04 0 No
Yes Study Plant 2 P2-100-02_005mmP2-010-05 0 No
Yes Study Plant 2 P2-100-02_025mmP2-010-05 0 No
Yes Study Plant 2 P2-100-02_065mmP2-010-05 0 No
Yes Study Plant 2 P2-100-02_FBR P2-010-05 0 No
Yes Study Plant 2 P2-100-03_005mmP2-010-05 0 No
Yes Study Plant 2 P2-100-03_025mmP2-010-05 0 No
Yes Study Plant 2 P2-100-03_065mmP2-010-05 0 No
Yes Study Plant 2 P2-100-03_FBR P2-010-05 0 No
Yes Study Plant 2 P2-100-04_005mmP2-010-07 0 No
Yes Study Plant 2 P2-100-04_025mmP2-010-07 0 No
Yes Study Plant 2 P2-100-04_065mmP2-010-07 0 No
Yes Study Plant 2 P2-100-04_FBR P2-010-07 0 No
Yes Study Plant 2 P2-200-01_005mmP2-020-01 0 No
Yes Study Plant 2 P2-200-01_025mmP2-020-01 0 No
Yes Study Plant 2 P2-200-01_065mmP2-020-01 0 No
Yes Study Plant 2 P2-200-01_FBR P2-020-01 0 No
Yes Study Plant 2 P2-200-02.1_005mP2-020-03 0 No
Yes Study Plant 2 P2-200-02.1_025mP2-020-03 0 No

Open
Yes Study Plant 2 P2-200-02.1_065mP2-020-03 0 No
Yes Study Plant 2 P2-200-02.1_FBR P2-020-03 0 No
Yes Study Plant 2 P2-200-02.2_005mP2-020-06 0 No
Yes Study Plant 2 P2-200-02.2_025mP2-020-06 0 No
Yes Study Plant 2 P2-200-02.2_065mP2-020-06 0 No
Yes Study Plant 2 P2-200-02.2_FBR P2-020-06 0 No
Yes Study Plant 2 P2-200-02.3_005mP2-020-02 0 No
Yes Study Plant 2 P2-200-02.3_025mP2-020-02 0 No
Yes Study Plant 2 P2-200-02.3_065mP2-020-02 0 No
Yes Study Plant 2 P2-200-02.3_FBR P2-020-02 0 No
Yes Study Plant 2 P2-200-02.4_005mP2-020-02 0 No
Yes Study Plant 2 P2-200-02.4_025mP2-020-02 0 No
Yes Study Plant 2 P2-200-02.4_065mP2-020-02 0 No
Yes Study Plant 2 P2-200-02.4_FBR P2-020-02 0 No
Yes Study Plant 2 P2-250-01_005mmP2-020-07 0 No
Yes Study Plant 2 P2-250-01_025mmP2-020-07 0 No
Yes Study Plant 2 P2-250-01_065mmP2-020-07 0 No
Yes Study Plant 2 P2-250-01_FBR P2-020-07 0 No
Yes Study Plant 2 P2-250-02_005mmP2-020-07 0 No
Yes Study Plant 2 P2-250-02_025mmP2-020-07 0 No
Yes Study Plant 2 P2-250-02_065mmP2-020-07 0 No
Yes Study Plant 2 P2-250-02_FBR P2-020-07 0 No
Yes Study Plant 2 P2-250-03_005mmP2-025-01 0 No
Yes Study Plant 2 P2-250-03_025mmP2-025-01 0 No
Yes Study Plant 2 P2-250-03_065mmP2-025-01 0 No
Yes Study Plant 2 P2-250-03_FBR P2-025-01 0 No
Yes Study Plant 2 P2-250-04_005mmP2-025-02 0 No
Yes Study Plant 2 P2-250-04_025mmP2-025-02 0 No
Yes Study Plant 2 P2-250-04_065mmP2-025-02 0 No
Yes Study Plant 2 P2-250-04_FBR P2-025-02 0 No
Yes Study Plant 2 P2-300-01_005mmP2-030-03 0 No
Yes Study Plant 2 P2-300-01_025mmP2-030-03 0 No
Yes Study Plant 2 P2-300-01_065mmP2-030-03 0 No
Yes Study Plant 2 P2-300-01_FBR P2-030-03 0 No
Yes Study Plant 2 P2-300-02_005mmP2-030-04 0 No
Yes Study Plant 2 P2-300-02_025mmP2-030-04 0 No
Yes Study Plant 2 P2-300-02_065mmP2-030-04 0 No
Yes Study Plant 2 P2-300-02_FBR P2-030-04 0 No
Yes Study Plant 2 P2-300-03_005mmP2-030-04 0 No
Yes Study Plant 2 P2-300-03_025mmP2-030-04 0 No
Yes Study Plant 2 P2-300-03_065mmP2-030-04 0 No
Yes Study Plant 2 P2-300-03_FBR P2-030-04 0 No
Yes Study Plant 2 P2-300-04_005mmP2-030-04 0 No
Yes Study Plant 2 P2-300-04_025mmP2-030-04 0 No
Yes Study Plant 2 P2-300-04_065mmP2-030-04 0 No
Yes Study Plant 2 P2-300-04_FBR P2-030-04 0 No
Yes Study Plant 2 P2-300-05_005mmP2-030-07 0 No
Yes Study Plant 2 P2-300-05_025mmP2-030-07 0 No
Yes Study Plant 2 P2-300-05_065mmP2-030-07 0 No
Yes Study Plant 2 P2-300-05_FBR P2-030-07 0 No

Open
Yes Study Plant 2 P2-300-06_005mmP2-030-07 0 No
Yes Study Plant 2 P2-300-06_025mmP2-030-07 0 No
Yes Study Plant 2 P2-300-06_065mmP2-030-07 0 No
Yes Study Plant 2 P2-300-06_FBR P2-030-07 0 No
Yes Study Plant 2 P2-300-07_005mmP2-030-07 0 No
Yes Study Plant 2 P2-300-07_025mmP2-030-07 0 No
Yes Study Plant 2 P2-300-07_065mmP2-030-07 0 No
Yes Study Plant 2 P2-300-07_FBR P2-030-07 0 No
Yes Study Plant 2 P2-300-08_005mmP2-030-06 0 No
Yes Study Plant 2 P2-300-08_025mmP2-030-06 0 No
Yes Study Plant 2 P2-300-08_065mmP2-030-06 0 No
Yes Study Plant 2 P2-300-08_FBR P2-030-06 0 No
Yes Study Plant 2 P2-300-09_005mmP2-030-12 0 No
Yes Study Plant 2 P2-300-09_025mmP2-030-12 0 No
Yes Study Plant 2 P2-300-09_065mmP2-030-12 0 No
Yes Study Plant 2 P2-300-09_FBR P2-030-12 0 No
Yes Study Plant 2 P2-300-10_005mmP2-030-12 0 No
Yes Study Plant 2 P2-300-10_025mmP2-030-12 0 No
Yes Study Plant 2 P2-300-10_065mmP2-030-12 0 No
Yes Study Plant 2 P2-300-10_FBR P2-030-12 0 No
Yes Study Plant 2 P2-300-11_005mmP2-030-12 0 No
Yes Study Plant 2 P2-300-11_025mmP2-030-12 0 No
Yes Study Plant 2 P2-300-11_065mmP2-030-12 0 No
Yes Study Plant 2 P2-300-11_FBR P2-030-12 0 No
Yes Study Plant 2 P2-400-01_005mmP2-030-08 0 No
Yes Study Plant 2 P2-400-01_025mmP2-030-08 0 No
Yes Study Plant 2 P2-400-01_065mmP2-030-08 0 No
Yes Study Plant 2 P2-400-01_FBR P2-030-08 0 No
Yes Study Plant 2 P2-400-02_005mmP2-030-08 0 No
Yes Study Plant 2 P2-400-02_025mmP2-030-08 0 No
Yes Study Plant 2 P2-400-02_065mmP2-030-08 0 No
Yes Study Plant 2 P2-400-02_FBR P2-030-08 0 No
Yes Study Plant 2 P2-400-03_005mmP2-030-08 0 No
Yes Study Plant 2 P2-400-03_025mmP2-030-08 0 No
Yes Study Plant 2 P2-400-03_065mmP2-030-08 0 No
Yes Study Plant 2 P2-400-03_FBR P2-030-08 0 No
Yes Study Plant 2 P2-400-04_005mmP2-030-08 0 No
Yes Study Plant 2 P2-400-04_025mmP2-030-08 0 No
Yes Study Plant 2 P2-400-04_065mmP2-030-08 0 No
Yes Study Plant 2 P2-400-04_FBR P2-030-08 0 No
Yes Study Plant 2 P2-400-05_005mmP2-030-08 0 No
Yes Study Plant 2 P2-400-05_025mmP2-030-08 0 No
Yes Study Plant 2 P2-400-05_065mmP2-030-08 0 No
Yes Study Plant 2 P2-400-05_FBR P2-030-08 0 No
Yes Study Plant 2 P2-700-01_005mmNG 0 No
Yes Study Plant 2 P2-700-01_025mmNG 0 No
Yes Study Plant 2 P2-700-01_065mmNG 0 No
Yes Study Plant 2 P2-700-01_FBR NG 0 No
Yes Study Plant 2 P2-JETTY-01_005m MeOH 0 No
Yes Study Plant 2 P2-JETTY-01_025m MeOH 0 No

Open
Yes Study Plant 2 P2-JETTY-01_065m MeOH 0 No
Yes Study Plant 2 P2-JETTY-01_FBR MeOH 0 No

Open
Material
Material Phase

Specified
Mass inventory Volume inventory Material to track condition Temperature
kg m3 degC
1000000 61332.056660991 P1-101 25
1000000 61332.056660991 P1-101 25
1000000 P1-101 25
1000000 P1-101 25
1000000 P1-101 399
1000000 P1-101 399
1000000 P1-101 399
1000000 P1-101 399
1000000 P1-105 657
1000000 P1-105 657
1000000 P1-105 657
1000000 P1-105 657
1000000 P1-113 159
1000000 P1-113 159
1000000 P1-113 159
1000000 P1-113 159
1000000 P1-201 224
1000000 P1-201 224
1000000 P1-201 224
1000000 P1-201 224
1000000 P1-203 47
1000000 P1-203 47
1000000 P1-203 47
1000000 P1-203 47
1000000 P1-113 60
1000000 P1-113 60
1000000 P1-113 60
1000000 P1-113 60
1000000 P1-301 136.8
1000000 P1-301 136.8
1000000 P1-301 136.8
1000000 P1-301 136.8
1000000 P1-304 83
1000000 P1-304 83
1000000 P1-304 83
1000000 P1-304 83
1000000 P1-306 685.8
1000000 P1-306 685.8
1000000 P1-306 685.8
1000000 P1-306 685.8

Open
1000000 P1-309 69
1000000 P1-309 69
1000000 P1-309 69
1000000 P1-309 69
1000000 MeOH 37.7
1000000 MeOH 37.7
1000000 MeOH 37.7
1000000 MeOH 37.7
1000000 MeOH 40
1000000 MeOH 40
1000000 MeOH 40
1000000 MeOH 40
1000000 MeOH 40
1000000 MeOH 40
1000000 MeOH 40
1000000 MeOH 40
1000000 MeOH 40
1000000 MeOH 40
1000000 MeOH 40
1000000 MeOH 40
1000000 MeOH 40
1000000 MeOH 40
1000000 MeOH 40
1000000 MeOH 40
1000000 NG 25
1000000 NG 25
1000000 NG 25
1000000 NG 25
1000000 P2-010-04 380
1000000 P2-010-04 380
1000000 P2-010-04 380
1000000 P2-010-04 380
1000000 P2-010-05 400
1000000 P2-010-05 400
1000000 P2-010-05 400
1000000 P2-010-05 400
1000000 P2-010-05 480
1000000 P2-010-05 480
1000000 P2-010-05 480
1000000 P2-010-05 480
1000000 P2-010-07 468
1000000 P2-010-07 468
1000000 P2-010-07 468
1000000 P2-010-07 468
1000000 P2-020-01 154
1000000 P2-020-01 154
1000000 P2-020-01 154
1000000 P2-020-01 154
1000000 P2-020-03 255
1000000 P2-020-03 255

Open
1000000 P2-020-03 255
1000000 P2-020-03 255
1000000 P2-020-06 40
1000000 P2-020-06 40
1000000 P2-020-06 40
1000000 P2-020-06 40
1000000 P2-020-02 57
1000000 P2-020-02 57
1000000 P2-020-02 57
1000000 P2-020-02 57
1000000 P2-020-02 94
1000000 P2-020-02 94
1000000 P2-020-02 94
1000000 P2-020-02 94
1000000 P2-020-07 40
1000000 P2-020-07 40
1000000 P2-020-07 40
1000000 P2-020-07 40
1000000 P2-020-07 40
1000000 P2-020-07 40
1000000 P2-020-07 40
1000000 P2-020-07 40
1000000 P2-025-01 40
1000000 P2-025-01 40
1000000 P2-025-01 40
1000000 P2-025-01 40
1000000 P2-025-02 40
1000000 P2-025-02 40
1000000 P2-025-02 40
1000000 P2-025-02 40
1000000 P2-030-03 93
1000000 P2-030-03 93
1000000 P2-030-03 93
1000000 P2-030-03 93
1000000 P2-030-04 140
1000000 P2-030-04 140
1000000 P2-030-04 140
1000000 P2-030-04 140
1000000 P2-030-04 128
1000000 P2-030-04 128
1000000 P2-030-04 128
1000000 P2-030-04 128
1000000 P2-030-04 128
1000000 P2-030-04 128
1000000 P2-030-04 128
1000000 P2-030-04 128
1000000 P2-030-07 69
1000000 P2-030-07 69
1000000 P2-030-07 69
1000000 P2-030-07 69

Open
1000000 P2-030-07 41
1000000 P2-030-07 41
1000000 P2-030-07 41
1000000 P2-030-07 41
1000000 P2-030-07 41
1000000 P2-030-07 41
1000000 P2-030-07 41
1000000 P2-030-07 41
1000000 P2-030-06 128
1000000 P2-030-06 128
1000000 P2-030-06 128
1000000 P2-030-06 128
1000000 P2-030-12 83
1000000 P2-030-12 83
1000000 P2-030-12 83
1000000 P2-030-12 83
1000000 P2-030-12 64
1000000 P2-030-12 64
1000000 P2-030-12 64
1000000 P2-030-12 64
1000000 P2-030-12 120
1000000 P2-030-12 120
1000000 P2-030-12 120
1000000 P2-030-12 120
1000000 P2-030-08 40
1000000 P2-030-08 40
1000000 P2-030-08 40
1000000 P2-030-08 40
1000000 P2-030-08 40
1000000 P2-030-08 40
1000000 P2-030-08 40
1000000 P2-030-08 40
1000000 P2-030-08 40
1000000 P2-030-08 40
1000000 P2-030-08 40
1000000 P2-030-08 40
1000000 P2-030-08 40
1000000 P2-030-08 40
1000000 P2-030-08 40
1000000 P2-030-08 40
1000000 P2-030-08 40
1000000 P2-030-08 40
1000000 P2-030-08 40
1000000 P2-030-08 40
1000000 NG 30
1000000 NG 30
1000000 NG 30
1000000 NG 30
1000000 MeOH 30
1000000 MeOH 30

Open
1000000 MeOH 30
1000000 MeOH 30

Open
al
Phase Modelling of mixtures

Liquid mole Phase to be


Pressure (gauge) fraction released Multi or pseudo-component modelling
bar fraction
27 0 1 Vapour
27 0 1 Vapour
27
27
41
41
41
41
31.5
31.5
31.5
31.5
82.5
82.5
82.5
82.5
81.5
81.5
81.5
81.5
82.9
82.9
82.9
82.9
30.4
30.4
30.4
30.4
8.6
8.6
8.6
8.6
1.1
1.1
1.1
1.1
7.1
7.1
7.1
7.1

Open
0.2
0.2
0.2
0.2
1.5
1.5
1.5
1.5
3
3
3
3
1
1
1
1
2
2
2
2
4.5
4.5
4.5
4.5
27
27
27
27
49.4
49.4
49.4
49.4
45.1
45.1
45.1
45.1
42.1
42.1
42.1
42.1
41.1
41.1
41.1
41.1
75.6
75.6
75.6
75.6
73.8
73.8

Open
73.8
73.8
66.2
66.2
66.2
66.2
75.7
75.7
75.7
75.7
74.8
74.8
74.8
74.8
66.2
66.2
66.2
66.2
66.2
66.2
66.2
66.2
32
32
32
32
0.5
0.5
0.5
0.5
5
5
5
5
8
8
8
8
7.1
7.1
7.1
7.1
7.1
7.1
7.1
7.1
0.2
0.2
0.2
0.2

Open
0.2
0.2
0.2
0.2
5.8
5.8
5.8
5.8
6.9
6.9
6.9
6.9
1.1
1.1
1.1
1.1
3.2
3.2
3.2
3.2
1.1
1.1
1.1
1.1
0.01
0.01
0.01
0.01
0.01
0.01
0.01
0.01
0.01
0.01
0.01
0.01
0.01
0.01
0.01
0.01
0.01
0.01
0.01
0.01
30
30
30
30
7.6
7.6

Open
7.6
7.6

Open
Scenario
Pipe dimensions Release location Direction

Release height
from vessel Outdoor release
Pipe length Elevation Tank head bottom direction
m m m m

Open
Open
Open
Open
Open
Discharge parameters
Direction Model settings Droplet break-up mechanism

Atmospheric Phase change Droplet break-up Droplet break-up


Outdoor release expansion upstream of mechanism - mechanism -
angle method orifice? instantaneous continuous
deg
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0

Open
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0

Open
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0

Open
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0

Open
0
0

Open
Short pipe
Pipe characteristics Frequencies

Frequency of Frequency of Frequency of


Pipe roughness bends in pipe couplings in pipe junctions in pipe
mm /m /m /m

Open
Open
Open
Open
Open
Short pipe
Frequencies of valves Velocity head losses

Excess flow valve Non-return valve


Frequency of Frequency of non- Frequency of velocity head velocity head
excess flow valves return valves shut-off valves losses losses
/m /m /m

Open
Open
Open
Open
Open
Time varying releases
head losses
Modelling of time-varying leaks and line ruptures Dimensions

Shut-off valve
velocity head Vacuum relief Vacuum relief
losses valve valve set point Tank shape Tank height
bar m

Open
Open
Open
Open
Open
ing releases
Dimensions Dispersion scope

Averaging time for


Concentration of concentration of
Tank width Tank length Tank diameter interest interest
m m m ppm

Open
Open
Open
Open
Open
Dispersion
ispersion scope Distances of interest Averaging time for rep

Specify user-
defined averaging User defined
time averaging time Distances of interest ERPG [1 hr]
s m
0 No 0 No
0 No 0 No

Open
Open
Open
Open
Open
Bund, building a
Averaging time for reports Terrain and bund definition B

Type of pool
Type of terrain for substrate and
IDLH [30 mins] STEL [15 mins] dispersion bunds Release building

0 No 0 No
0 No 0 No

Open
Open
Open
Open
Open
Bund, building and terrain
Building definition

Indoor mass
In-building Building wake Wind or release Handling of modification
release? effect angle from North droplets factor
deg

Open
Open
Open
Open
Open
Toxic parameters
Indoor toxic calculations Exposure time data
Cut-off fraction of Cut-off
Specify the Building type Set averaging time toxic load for concentration for
downwind (downwind equal to exposure exposure time exposure time
building type building type) time calculation calculations
fraction fraction

Open
Open
Open
Open
Open
arameters
Toxic contours

Number of toxic
levels Dose levels Probit levels Lethality levels
fraction

Open
Open
Open
Open
Open
Explosion parameters
Explosion method (Consequence calculations only)

Explosion method

Open
Open
Open
Open
Open
parameters
Ignition Vapour liquid method
Multi-Energy: User-defined

Use explosion Explosion mass


Supply late Location of late mass modification modification Unconfined
ignition location ignition factor factor explosion strength
m

Open
Open
Open
Open
Open
Multi-Energy
Energy: User-defined Confined explosion sources

Unconfined Option for


explosion Number of specifying size of Strength of Volume of
efficiency confined sources confined sources confined source confined source
% m3

Open
Open
Open
Open
Open
Baker-Strehlow-Tang
ces Flame speed option Calculated flame speed

User specified
Volume fraction Mach number flame Mach
of confined source supplied number Flame expansion Obstacle density
fraction

Open
Open
Open
Open
Open
ehlow-Tang TNT
flame speed Ground correction factor TNT parameters

Default TNT
Correction for the The confined Air or ground explosion
Fuel reactivity ground effect volume burst efficiency
m3 fraction

Open
Open
Open
Open
Open
Fireball
Result types to calculate Radiation levels

Number of input
Calculate probit Calculate dose Calculate lethality radiation levels Intensity levels
kW/m2

Open
Open
Open
Open
Open
Fireball
Radiation levels Parameters Calculation method

Mass modification
Probit levels Dose levels Lethality levels factor Fireball model
fraction

Open
Open
Open
Open
Open
lculation method Jet fire method Result types to calculate

TNO model flame


temperature Jet fire method Calculate probit Calculate dose Calculate lethality
degC

Open
Open
Open
Open
Open
Jet fire
Radiation levels

Number of input
radiation levels Intensity levels Probit levels Dose levels Lethality levels
kW/m2 fraction

Open
Open
Open
Open
Open
fire
Parameters Cone model data

Flame-shape
Rate modification adjustment if
factor Crosswind angle Horizontal options Correlation grounded
deg

Open
Open
Open
Open
Open
Surface emissive power Result types to calculate
Calculation
method for
surface emissive Flame emissive
power power Emissivity fraction Calculate probit Calculate dose
kW/m2 fraction

Open
Open
Open
Open
Open
Pool fire
es to calculate Radiation levels

Number of input
Calculate lethality radiation levels Intensity levels Probit levels Dose levels
kW/m2

Open
Open
Open
Open
Open
Geometry
Parameters Geometry Invisible

Radiative fraction for


Lethality levels general fires East North Shape
fraction fraction m m
0 Point
0 0 0 Point

Open
Open
Open
Open
Open
ry
Invisible

Dimension

0 2D
0 2D

Open
Open
Open
Open
Open
Material

Specify volume
Use Study Folder Name Material inventory?

Open
Material
Material Phase

Specified
Mass inventory Volume inventory Material to track condition Temperature
kg m3 degC

Open
al
Phase Modelling of mixtures

Liquid mole Phase to be


Pressure (gauge) fraction released Multi or pseudo-component modelling
bar fraction

Open
Scenario
Pipe dimensions Release location Direction

Release height
from vessel Outdoor release
Pipe length Elevation Tank head bottom direction
m m m m

Open
Discharge parameters
Direction Model settings Droplet break-up mechanism

Atmospheric Phase change Droplet break-up Droplet break-up


Outdoor release expansion upstream of mechanism - mechanism -
angle method orifice? instantaneous continuous
deg

Open
Short pipe
Pipe characteristics Frequencies

Frequency of Frequency of Frequency of


Pipe roughness bends in pipe couplings in pipe junctions in pipe
mm /m /m /m

Open
Short pipe
Frequencies of valves Velocity head losses

Excess flow valve Non-return valve


Frequency of Frequency of non- Frequency of velocity head velocity head
excess flow valves return valves shut-off valves losses losses
/m /m /m

Open
Time varying releases
head losses
Modelling of time-varying leaks and line ruptures Dimensions

Shut-off valve
velocity head Vacuum relief Vacuum relief
losses valve valve set point Tank shape Tank height
bar m

Open
ing releases
Dimensions Dispersion scope

Averaging time for


Concentration of concentration of
Tank width Tank length Tank diameter interest interest
m m m ppm

Open
Dispersion
ispersion scope Distances of interest Averaging time for rep

Specify user-
defined averaging User defined
time averaging time Distances of interest ERPG [1 hr]
s m

Open
Bund, building a
Averaging time for reports Terrain and bund definition B

Type of pool
Type of terrain for substrate and
IDLH [30 mins] STEL [15 mins] dispersion bunds Release building

Open
Bund, building and terrain
Building definition

Indoor mass
In-building Building wake Wind or release Handling of modification
release? effect angle from North droplets factor
deg

Open
Toxic parameters
Indoor toxic calculations Exposure time data
Cut-off fraction of Cut-off
Specify the Building type Set averaging time toxic load for concentration for
downwind (downwind equal to exposure exposure time exposure time
building type building type) time calculation calculations
fraction fraction

Open
arameters
Toxic contours

Number of toxic
levels Dose levels Probit levels Lethality levels
fraction

Open
Explosion parameters
Explosion method (Consequence calculations only)

Explosion method

Open
parameters
Ignition Vapour liquid method
Multi-Energy: User-defined

Use explosion Explosion mass


Supply late Location of late mass modification modification Unconfined
ignition location ignition factor factor explosion strength
m

Open
Multi-Energy
Energy: User-defined Confined explosion sources

Unconfined Option for


explosion Number of specifying size of Strength of Volume of
efficiency confined sources confined sources confined source confined source
% m3

Open
Baker-Strehlow-Tang
ces Flame speed option Calculated flame speed

User specified
Volume fraction Mach number flame Mach
of confined source supplied number Flame expansion Obstacle density
fraction

Open
ehlow-Tang TNT
flame speed Ground correction factor TNT parameters

Default TNT
Correction for the The confined Air or ground explosion
Fuel reactivity ground effect volume burst efficiency
m3 fraction

Open
Jet fire method Result types to calculate

Number of input
Jet fire method Calculate probit Calculate dose Calculate lethality radiation levels

Open
Jet fire
Radiation levels Parameters

Rate modification
Intensity levels Probit levels Dose levels Lethality levels factor
kW/m2 fraction

Open
Cone model data Surface emissive pow
Calculation
Flame-shape method for
adjustment if surface emissive
Crosswind angle Horizontal options Correlation grounded power
deg

Open
Po
Surface emissive power Result types to calculate

Flame emissive
power Emissivity fraction Calculate probit Calculate dose Calculate lethality
kW/m2 fraction

Open
Pool fire
Radiation levels

Number of input
radiation levels Intensity levels Probit levels Dose levels Lethality levels
kW/m2 fraction

Open
Geometry
Parameters Geometry Invisible

Radiative fraction for


general fires East North Shape Dimension
fraction m m

Open
Material Geom
Material Geometry

Use Study Folder Name Material East


m

Open
Geometry
Geometry Invisible

North Shape Dimension


m

Open
M
Material

Use Study Folder Name Material Material to track

Open
Material
Phase

Specified Liquid mole Phase to be


condition Temperature Pressure (gauge) fraction released
degC bar fraction

Open
Scenario
Pipe dimensions Release location Direction

Outdoor release Outdoor release


Pipe internal diameter Elevation direction angle
mm m deg

Open
Pump data Breach data Pipe characteristics
Construction
material (enabled
in discharge Pipe wall
Pumped inflow Breach sizing method Pipe roughness parameters) thickness
kg/s mm mm

Open
Long pipe
Valves

Valve distance
from pipeline
Number of valves Valve type start Valve closing time Valve excess flow
m s kg/s

Open
Time varying
Crater modelling Time averag

Method for
Is the pipeline Depth of soil Duration of calculating
buried? cover Soil cover type interest average rate
m s

Open
Time varying releases
Time averaging Dispersion sc

Time at which First time value Second time value


Expected number release rate is for rate between for rate between Concentration of
of average rates calculated two times two times interest
s s s ppm

Open
Dispersion
Dispersion scope Distances of interest

Averaging time for Specify user-


concentration of defined averaging User defined
interest time averaging time Distances of interest
s m

Open
Bund, building and terrain
Averaging time for reports Terrain and bund definition

Type of pool
Type of terrain for substrate and
ERPG [1 hr] IDLH [30 mins] STEL [15 mins] dispersion bunds

Open
Toxic parameters
Indoor toxic calculations Exposure time data
Cut-off fraction of Cut-off
Specify the Building type Set averaging time toxic load for concentration for
downwind (downwind equal to exposure exposure time exposure time
building type building type) time calculation calculations
fraction fraction

Open
arameters
Toxic contours

Number of toxic
levels Dose levels Probit levels Lethality levels
fraction

Open
Explosion parameters
Explosion method (Consequence calculations only)

Explosion method

Open
parameters
Ignition Vapour liquid method
Multi-Energy: User-defined

Use explosion Explosion mass


Supply late Location of late mass modification modification Unconfined
ignition location ignition factor factor explosion strength
m

Open
Multi-Energy
Energy: User-defined Confined explosion sources

Unconfined Option for


explosion Number of specifying size of Strength of Volume of
efficiency confined sources confined sources confined source confined source
% m3

Open
Baker-Strehlow-Tang
ces Flame speed option Calculated flame speed

User specified
Volume fraction Mach number flame Mach
of confined source supplied number Flame expansion Obstacle density
fraction

Open
ehlow-Tang TNT
flame speed Ground correction factor TNT parameters

Default TNT
Correction for the The confined Air or ground explosion
Fuel reactivity ground effect volume burst efficiency
m3 fraction

Open
Fireball
Result types to calculate Radiation levels

Number of input
Calculate probit Calculate dose Calculate lethality radiation levels Intensity levels
kW/m2

Open
Fireball
Radiation levels Parameters Calculation method

Mass modification
Probit levels Dose levels Lethality levels factor Fireball model
fraction

Open
lculation method Jet fire method Result types to calculate

TNO model flame


temperature Jet fire method Calculate probit Calculate dose Calculate lethality
degC

Open
Jet fire
Radiation levels

Number of input
radiation levels Intensity levels Probit levels Dose levels Lethality levels
kW/m2 fraction

Open
fire
Parameters Cone model data

Flame-shape
Rate modification adjustment if
factor Crosswind angle Horizontal options Correlation grounded
deg

Open
Surface emissive power Result types to calculate
Calculation
method for
surface emissive Flame emissive
power power Emissivity fraction Calculate probit Calculate dose
kW/m2 fraction

Open
Pool fire
es to calculate Radiation levels

Number of input
Calculate lethality radiation levels Intensity levels Probit levels Dose levels
kW/m2

Open
Geometry
Parameters Geometry Invisible

Radiative fraction for


Lethality levels general fires East North Shape
fraction fraction m m

Open
ry
Invisible

Dimension

Open
Warehouse materials
Warehouse materials

Warehouse
Use Study Folder Name material Stored mass
kg

Open
se materials Building
se materials Building Building wake effect Warehouse

Warehouse is part
Active mass Warehouse Building wake Wind or release of a larger
fraction building effect angle from North building
fraction deg

Open
g
Warehouse Fire scenarios ADR class 3 liquids

Reaction rate
Warehouse area Warehouse height Scenario type Storage type calculation
m2 m

Open
Fire scenarios
DR class 3 liquids PGS-15 scenarios

Method of setting Number of


Specified reaction Fire-fighting likelihood of warehouse
Mass fraction rate system doors being open scenarios
fraction kg/m2.s

Open
os
User-defined scenarios

Ventilation rate
Name Fire surface area option Air change Fire duration
m2 /hr s

Open
Dispersion
Dispersion scope

Averaging time for Specify user-


Concentration of concentration of defined averaging User defined
Probability interest interest time averaging time
fraction ppm s

Open
Dispersion
Distances of interest Averaging time for reports

Distances of interest ERPG [1 hr] IDLH [30 mins] STEL [15 mins]
m

Open
Atmospheric
Use Study Folder Pressure vessel Folder storage tank

Open
Scenario
Release location Fireball emissive power

Use vessel burst


Folder Name Elevation Tank head pressure
m m

Open
o Material
all emissive power Material Phase

Vessel burst Phase to be


pressure - gauge Material to track released
bar

Open
Discharge parameters
Droplet break-up mechanism Dispersion scope

Averaging time for


Concentration of concentration of
Droplet break-up mechanism - instantaneous interest interest
ppm

Open
Dispersion
ispersion scope Distances of interest Averaging time for rep

Specify user-
defined averaging User defined
time averaging time Distances of interest ERPG [1 hr]
s m

Open
Bund, building and terrain
Averaging time for reports Terrain and bund definition
Indoor toxic calculations

Type of pool Specify the


Type of terrain for substrate and downwind
IDLH [30 mins] STEL [15 mins] dispersion bunds building type

Open
Toxic parameters
or toxic calculations Exposure time data Toxic conto
Cut-off fraction of Cut-off
Building type Set averaging time toxic load for concentration for
(downwind equal to exposure exposure time exposure time Number of toxic
building type) time calculation calculations levels
fraction fraction

Open
rs Explosion para
Toxic contours Explosion method

Dose levels Probit levels Lethality levels Explosion method


fraction

Open
Explosion parameters
Ignition Vapour liquid method
Multi-Energy: User-defined

Use explosion Explosion mass


Supply late Location of late mass modification modification Unconfined
ignition location ignition factor factor explosion strength
m

Open
Multi-Energy
Energy: User-defined Confined explosion sources

Unconfined Option for


explosion Number of specifying size of Strength of Volume of
efficiency confined sources confined sources confined source confined source
% m3

Open
Baker-Strehlow-Tang
ces Flame speed option Calculated flame speed

User specified
Volume fraction Mach number flame Mach
of confined source supplied number Flame expansion Obstacle density
fraction

Open
ehlow-Tang TNT
flame speed Ground correction factor TNT parameters

Default TNT
Correction for the The confined Air or ground explosion
Fuel reactivity ground effect volume burst efficiency
m3 fraction

Open
Fireball
Result types to calculate Radiation levels

Number of input
Calculate probit Calculate dose Calculate lethality radiation levels Intensity levels
kW/m2

Open
Fireball
Radiation levels Parameters Calculation method

Mass modification
Probit levels Dose levels Lethality levels factor Fireball model
fraction

Open
lculation method Jet fire method Result types to calculate

TNO model flame


temperature Jet fire method Calculate probit Calculate dose Calculate lethality
degC

Open
Jet fire
Radiation levels

Number of input
radiation levels Intensity levels Probit levels Dose levels Lethality levels
kW/m2 fraction

Open
Parameters Cone model data Surface emissive po
Calculation
Flame-shape method for
Rate modification adjustment if surface emissive
factor Correlation Horizontal options grounded power

Open
Po
Surface emissive power Result types to calculate

Flame emissive
power Emissivity fraction Calculate probit Calculate dose Calculate lethality
kW/m2 fraction

Open
Pool fire
Radiation levels

Number of input
radiation levels Intensity levels Probit levels Dose levels Lethality levels
kW/m2 fraction

Open
Parameters

Radiative fraction for


general fires
fraction

Open
Atmospheric
Use Study Folder Pressure vessel Folder storage tank

Yes Study Plant 1 P1-100-01_005mm


Yes Study Plant 1 P1-100-01_025mm
Yes Study Plant 1 P1-100-01_065mm
Yes Study Plant 1 P1-100-01_FBR
Yes Study Plant 1 P1-100-02_005mm
Yes Study Plant 1 P1-100-02_025mm
Yes Study Plant 1 P1-100-02_065mm
Yes Study Plant 1 P1-100-02_FBR
Yes Study Plant 1 P1-100-03_005mm
Yes Study Plant 1 P1-100-03_025mm
Yes Study Plant 1 P1-100-03_065mm
Yes Study Plant 1 P1-100-03_FBR
Yes Study Plant 1 P1-200-01_005mm
Yes Study Plant 1 P1-200-01_025mm
Yes Study Plant 1 P1-200-01_065mm
Yes Study Plant 1 P1-200-01_FBR
Yes Study Plant 1 P1-200-02_005mm
Yes Study Plant 1 P1-200-02_025mm
Yes Study Plant 1 P1-200-02_065mm
Yes Study Plant 1 P1-200-02_FBR
Yes Study Plant 1 P1-200-03_005mm
Yes Study Plant 1 P1-200-03_025mm
Yes Study Plant 1 P1-200-03_065mm
Yes Study Plant 1 P1-200-03_FBR
Yes Study Plant 1 P1-200-04_005mm
Yes Study Plant 1 P1-200-04_025mm
Yes Study Plant 1 P1-200-04_065mm
Yes Study Plant 1 P1-200-04_FBR
Yes Study Plant 1 P1-300-01_005mm
Yes Study Plant 1 P1-300-01_025mm
Yes Study Plant 1 P1-300-01_065mm
Yes Study Plant 1 P1-300-01_FBR
Yes Study Plant 1 P1-300-02_005mm
Yes Study Plant 1 P1-300-02_025mm
Yes Study Plant 1 P1-300-02_065mm
Yes Study Plant 1 P1-300-02_FBR
Yes Study Plant 1 P1-300-03_005mm
Yes Study Plant 1 P1-300-03_025mm
Yes Study Plant 1 P1-300-03_065mm
Yes Study Plant 1 P1-300-03_FBR

Open
Yes Study Plant 1 P1-300-04_005mm
Yes Study Plant 1 P1-300-04_025mm
Yes Study Plant 1 P1-300-04_065mm
Yes Study Plant 1 P1-300-04_FBR
Yes Study Plant 1 P1-400-01_005mm
Yes Study Plant 1 P1-400-01_025mm
Yes Study Plant 1 P1-400-01_065mm
Yes Study Plant 1 P1-400-01_FBR
Yes Study Plant 1 P1-400-02_005mm
Yes Study Plant 1 P1-400-02_025mm
Yes Study Plant 1 P1-400-02_065mm
Yes Study Plant 1 P1-400-02_FBR
Yes Study Plant 1 P1-400-03_005mm
Yes Study Plant 1 P1-400-03_025mm
Yes Study Plant 1 P1-400-03_065mm
Yes Study Plant 1 P1-400-03_FBR
Yes Study Plant 1 P1-1100-01_005mm
Yes Study Plant 1 P1-1100-01_025mm
Yes Study Plant 1 P1-1100-01_065mm
Yes Study Plant 1 P1-1100-01_FBR
Yes Study Plant 1 P1-1100-02_005mm
Yes Study Plant 1 P1-1100-02_025mm
Yes Study Plant 1 P1-1100-02_065mm
Yes Study Plant 1 P1-1100-02_FBR
Yes Study Plant 1 P1-700-01_005mm
Yes Study Plant 1 P1-700-01_025mm
Yes Study Plant 1 P1-700-01_065mm
Yes Study Plant 1 P1-700-01_FBR
Yes Study Plant 2 P2-100-01_005mm
Yes Study Plant 2 P2-100-01_025mm
Yes Study Plant 2 P2-100-01_065mm
Yes Study Plant 2 P2-100-01_FBR
Yes Study Plant 2 P2-100-02_005mm
Yes Study Plant 2 P2-100-02_025mm
Yes Study Plant 2 P2-100-02_065mm
Yes Study Plant 2 P2-100-02_FBR
Yes Study Plant 2 P2-100-03_005mm
Yes Study Plant 2 P2-100-03_025mm
Yes Study Plant 2 P2-100-03_065mm
Yes Study Plant 2 P2-100-03_FBR
Yes Study Plant 2 P2-100-04_005mm
Yes Study Plant 2 P2-100-04_025mm
Yes Study Plant 2 P2-100-04_065mm
Yes Study Plant 2 P2-100-04_FBR
Yes Study Plant 2 P2-200-01_005mm
Yes Study Plant 2 P2-200-01_025mm
Yes Study Plant 2 P2-200-01_065mm
Yes Study Plant 2 P2-200-01_FBR
Yes Study Plant 2 P2-200-02.1_005mm
Yes Study Plant 2 P2-200-02.1_025mm

Open
Yes Study Plant 2 P2-200-02.1_065mm
Yes Study Plant 2 P2-200-02.1_FBR
Yes Study Plant 2 P2-200-02.2_005mm
Yes Study Plant 2 P2-200-02.2_025mm
Yes Study Plant 2 P2-200-02.2_065mm
Yes Study Plant 2 P2-200-02.2_FBR
Yes Study Plant 2 P2-200-02.3_005mm
Yes Study Plant 2 P2-200-02.3_025mm
Yes Study Plant 2 P2-200-02.3_065mm
Yes Study Plant 2 P2-200-02.3_FBR
Yes Study Plant 2 P2-200-02.4_005mm
Yes Study Plant 2 P2-200-02.4_025mm
Yes Study Plant 2 P2-200-02.4_065mm
Yes Study Plant 2 P2-200-02.4_FBR
Yes Study Plant 2 P2-250-01_005mm
Yes Study Plant 2 P2-250-01_025mm
Yes Study Plant 2 P2-250-01_065mm
Yes Study Plant 2 P2-250-01_FBR
Yes Study Plant 2 P2-250-02_005mm
Yes Study Plant 2 P2-250-02_025mm
Yes Study Plant 2 P2-250-02_065mm
Yes Study Plant 2 P2-250-02_FBR
Yes Study Plant 2 P2-250-03_005mm
Yes Study Plant 2 P2-250-03_025mm
Yes Study Plant 2 P2-250-03_065mm
Yes Study Plant 2 P2-250-03_FBR
Yes Study Plant 2 P2-250-04_005mm
Yes Study Plant 2 P2-250-04_025mm
Yes Study Plant 2 P2-250-04_065mm
Yes Study Plant 2 P2-250-04_FBR
Yes Study Plant 2 P2-300-01_005mm
Yes Study Plant 2 P2-300-01_025mm
Yes Study Plant 2 P2-300-01_065mm
Yes Study Plant 2 P2-300-01_FBR
Yes Study Plant 2 P2-300-02_005mm
Yes Study Plant 2 P2-300-02_025mm
Yes Study Plant 2 P2-300-02_065mm
Yes Study Plant 2 P2-300-02_FBR
Yes Study Plant 2 P2-300-03_005mm
Yes Study Plant 2 P2-300-03_025mm
Yes Study Plant 2 P2-300-03_065mm
Yes Study Plant 2 P2-300-03_FBR
Yes Study Plant 2 P2-300-04_005mm
Yes Study Plant 2 P2-300-04_025mm
Yes Study Plant 2 P2-300-04_065mm
Yes Study Plant 2 P2-300-04_FBR
Yes Study Plant 2 P2-300-05_005mm
Yes Study Plant 2 P2-300-05_025mm
Yes Study Plant 2 P2-300-05_065mm
Yes Study Plant 2 P2-300-05_FBR

Open
Yes Study Plant 2 P2-300-06_005mm
Yes Study Plant 2 P2-300-06_025mm
Yes Study Plant 2 P2-300-06_065mm
Yes Study Plant 2 P2-300-06_FBR
Yes Study Plant 2 P2-300-07_005mm
Yes Study Plant 2 P2-300-07_025mm
Yes Study Plant 2 P2-300-07_065mm
Yes Study Plant 2 P2-300-07_FBR
Yes Study Plant 2 P2-300-08_005mm
Yes Study Plant 2 P2-300-08_025mm
Yes Study Plant 2 P2-300-08_065mm
Yes Study Plant 2 P2-300-08_FBR
Yes Study Plant 2 P2-300-09_005mm
Yes Study Plant 2 P2-300-09_025mm
Yes Study Plant 2 P2-300-09_065mm
Yes Study Plant 2 P2-300-09_FBR
Yes Study Plant 2 P2-300-10_005mm
Yes Study Plant 2 P2-300-10_025mm
Yes Study Plant 2 P2-300-10_065mm
Yes Study Plant 2 P2-300-10_FBR
Yes Study Plant 2 P2-300-11_005mm
Yes Study Plant 2 P2-300-11_025mm
Yes Study Plant 2 P2-300-11_065mm
Yes Study Plant 2 P2-300-11_FBR
Yes Study Plant 2 P2-400-01_005mm
Yes Study Plant 2 P2-400-01_025mm
Yes Study Plant 2 P2-400-01_065mm
Yes Study Plant 2 P2-400-01_FBR
Yes Study Plant 2 P2-400-02_005mm
Yes Study Plant 2 P2-400-02_025mm
Yes Study Plant 2 P2-400-02_065mm
Yes Study Plant 2 P2-400-02_FBR
Yes Study Plant 2 P2-400-03_005mm
Yes Study Plant 2 P2-400-03_025mm
Yes Study Plant 2 P2-400-03_065mm
Yes Study Plant 2 P2-400-03_FBR
Yes Study Plant 2 P2-400-04_005mm
Yes Study Plant 2 P2-400-04_025mm
Yes Study Plant 2 P2-400-04_065mm
Yes Study Plant 2 P2-400-04_FBR
Yes Study Plant 2 P2-400-05_005mm
Yes Study Plant 2 P2-400-05_025mm
Yes Study Plant 2 P2-400-05_065mm
Yes Study Plant 2 P2-400-05_FBR
Yes Study Plant 2 P2-700-01_005mm
Yes Study Plant 2 P2-700-01_025mm
Yes Study Plant 2 P2-700-01_065mm
Yes Study Plant 2 P2-700-01_FBR
Yes Study Plant 2 P2-JETTY-01_005mm
Yes Study Plant 2 P2-JETTY-01_025mm

Open
Yes Study Plant 2 P2-JETTY-01_065mm
Yes Study Plant 2 P2-JETTY-01_FBR

Open
Scenario
Hole

Use specified
discharge Discharge
Folder Name Orifice diameter coefficient? coefficient
mm fraction
P1-100-01_005mm 5 0 No
P1-100-01_025mm 25 0 No
P1-100-01_065mm 65 0 No
P1-100-01_FBR 250 0 No
P1-100-02_005mm 5 0 No
P1-100-02_025mm 25 0 No
P1-100-02_065mm 65 0 No
P1-100-02_FBR 250 0 No
P1-100-03_005mm 5 0 No
P1-100-03_025mm 25 0 No
P1-100-03_065mm 65 0 No
P1-100-03_FBR 450 0 No
P1-200-01_005mm 5 0 No
P1-200-01_025mm 25 0 No
P1-200-01_065mm 65 0 No
P1-200-01_FBR 400 0 No
P1-200-02_005mm 5 0 No
P1-200-02_025mm 25 0 No
P1-200-02_065mm 65 0 No
P1-200-02_FBR 500 0 No
P1-200-03_005mm 5 0 No
P1-200-03_025mm 25 0 No
P1-200-03_065mm 65 0 No
P1-200-03_FBR 500 0 No
P1-200-04_005mm 5 0 No
P1-200-04_025mm 25 0 No
P1-200-04_065mm 65 0 No
P1-200-04_FBR 400 0 No
P1-300-01_005mm 5 0 No
P1-300-01_025mm 25 0 No
P1-300-01_065mm 65 0 No
P1-300-01_FBR 200 0 No
P1-300-02_005mm 5 0 No
P1-300-02_025mm 25 0 No
P1-300-02_065mm 65 0 No
P1-300-02_FBR 400 0 No
P1-300-03_005mm 5 0 No
P1-300-03_025mm 25 0 No
P1-300-03_065mm 65 0 No
P1-300-03_FBR 400 0 No

Open
P1-300-04_005mm 5 0 No
P1-300-04_025mm 25 0 No
P1-300-04_065mm 65 0 No
P1-300-04_FBR 900 0 No
P1-400-01_005mm 5 0 No
P1-400-01_025mm 25 0 No
P1-400-01_065mm 65 0 No
P1-400-01_FBR 200 0 No
P1-400-02_005mm 5 0 No
P1-400-02_025mm 25 0 No
P1-400-02_065mm 65 0 No
P1-400-02_FBR 200 0 No
P1-400-03_005mm 5 0 No
P1-400-03_025mm 25 0 No
P1-400-03_065mm 65 0 No
P1-400-03_FBR 200 0 No
P1-1100-01_005mm 5 0 No
P1-1100-01_025mm 25 0 No
P1-1100-01_065mm 65 0 No
P1-1100-01_FBR 600 0 No
P1-1100-02_005mm 5 0 No
P1-1100-02_025mm 25 0 No
P1-1100-02_065mm 65 0 No
P1-1100-02_FBR 600 0 No
P1-700-01_005mm 5 0 No
P1-700-01_025mm 25 0 No
P1-700-01_065mm 65 0 No
P1-700-01_FBR 75 0 No
P2-100-01_005mm 5 0 No
P2-100-01_025mm 25 0 No
P2-100-01_065mm 65 0 No
P2-100-01_FBR 450 0 No
P2-100-02_005mm 5 0 No
P2-100-02_025mm 25 0 No
P2-100-02_065mm 65 0 No
P2-100-02_FBR 600 0 No
P2-100-03_005mm 5 0 No
P2-100-03_025mm 25 0 No
P2-100-03_065mm 65 0 No
P2-100-03_FBR 600 0 No
P2-100-04_005mm 5 0 No
P2-100-04_025mm 25 0 No
P2-100-04_065mm 65 0 No
P2-100-04_FBR 600 0 No
P2-200-01_005mm 5 0 No
P2-200-01_025mm 25 0 No
P2-200-01_065mm 65 0 No
P2-200-01_FBR 600 0 No
P2-200-02.1_005mm 5 0 No
P2-200-02.1_025mm 25 0 No

Open
P2-200-02.1_065mm 65 0 No
P2-200-02.1_FBR 750 0 No
P2-200-02.2_005mm 5 0 No
P2-200-02.2_025mm 25 0 No
P2-200-02.2_065mm 65 0 No
P2-200-02.2_FBR 700 0 No
P2-200-02.3_005mm 5 0 No
P2-200-02.3_025mm 25 0 No
P2-200-02.3_065mm 65 0 No
P2-200-02.3_FBR 650 0 No
P2-200-02.4_005mm 5 0 No
P2-200-02.4_025mm 25 0 No
P2-200-02.4_065mm 65 0 No
P2-200-02.4_FBR 650 0 No
P2-250-01_005mm 5 0 No
P2-250-01_025mm 25 0 No
P2-250-01_065mm 65 0 No
P2-250-01_FBR 150 0 No
P2-250-02_005mm 5 0 No
P2-250-02_025mm 25 0 No
P2-250-02_065mm 65 0 No
P2-250-02_FBR 150 0 No
P2-250-03_005mm 5 0 No
P2-250-03_025mm 25 0 No
P2-250-03_065mm 65 0 No
P2-250-03_FBR 150 0 No
P2-250-04_005mm 5 0 No
P2-250-04_025mm 25 0 No
P2-250-04_065mm 65 0 No
P2-250-04_FBR 300 0 No
P2-300-01_005mm 5 0 No
P2-300-01_025mm 25 0 No
P2-300-01_065mm 65 0 No
P2-300-01_FBR 450 0 No
P2-300-02_005mm 5 0 No
P2-300-02_025mm 25 0 No
P2-300-02_065mm 65 0 No
P2-300-02_FBR 750 0 No
P2-300-03_005mm 5 0 No
P2-300-03_025mm 25 0 No
P2-300-03_065mm 65 0 No
P2-300-03_FBR 700 0 No
P2-300-04_005mm 5 0 No
P2-300-04_025mm 25 0 No
P2-300-04_065mm 65 0 No
P2-300-04_FBR 450 0 No
P2-300-05_005mm 5 0 No
P2-300-05_025mm 25 0 No
P2-300-05_065mm 65 0 No
P2-300-05_FBR 1000 0 No

Open
P2-300-06_005mm 5 0 No
P2-300-06_025mm 25 0 No
P2-300-06_065mm 65 0 No
P2-300-06_FBR 350 0 No
P2-300-07_005mm 5 0 No
P2-300-07_025mm 25 0 No
P2-300-07_065mm 65 0 No
P2-300-07_FBR 350 0 No
P2-300-08_005mm 5 0 No
P2-300-08_025mm 25 0 No
P2-300-08_065mm 65 0 No
P2-300-08_FBR 350 0 No
P2-300-09_005mm 5 0 No
P2-300-09_025mm 25 0 No
P2-300-09_065mm 65 0 No
P2-300-09_FBR 450 0 No
P2-300-10_005mm 5 0 No
P2-300-10_025mm 25 0 No
P2-300-10_065mm 65 0 No
P2-300-10_FBR 200 0 No
P2-300-11_005mm 5 0 No
P2-300-11_025mm 25 0 No
P2-300-11_065mm 65 0 No
P2-300-11_FBR 200 0 No
P2-400-01_005mm 5 0 No
P2-400-01_025mm 25 0 No
P2-400-01_065mm 65 0 No
P2-400-01_FBR 300 0 No
P2-400-02_005mm 5 0 No
P2-400-02_025mm 25 0 No
P2-400-02_065mm 65 0 No
P2-400-02_FBR 450 0 No
P2-400-03_005mm 5 0 No
P2-400-03_025mm 25 0 No
P2-400-03_065mm 65 0 No
P2-400-03_FBR 300 0 No
P2-400-04_005mm 5 0 No
P2-400-04_025mm 25 0 No
P2-400-04_065mm 65 0 No
P2-400-04_FBR 450 0 No
P2-400-05_005mm 5 0 No
P2-400-05_025mm 25 0 No
P2-400-05_065mm 65 0 No
P2-400-05_FBR 800 0 No
P2-700-01_005mm 5 0 No
P2-700-01_025mm 25 0 No
P2-700-01_065mm 65 0 No
P2-700-01_FBR 200 0 No
P2-JETTY-01_005mm 5 0 No
P2-JETTY-01_025mm 25 0 No

Open
P2-JETTY-01_065mm 65 0 No
P2-JETTY-01_FBR 600 0 No

Open
Scenario Material
Release location Direction Material

Outdoor release Outdoor release


Elevation Tank head direction angle Material to track
m m deg

Open
Open
Open
Open
Open
Material Discharge parameters
Phase Model settings

Atmospheric Phase change


Phase to be expansion upstream of
released method orifice?

Open
Open
Open
Open
Open
scharge parameters
Droplet break-up mechanism Dispersion scope

Averaging time for


Concentration of concentration of
Droplet break-up mechanism - continuous interest interest
ppm

Open
Open
Open
Open
Open
Dispersion
ispersion scope Distances of interest Averaging time for rep

Specify user-
defined averaging User defined
time averaging time Distances of interest ERPG [1 hr]
s m

Open
Open
Open
Open
Open
Bund, building and terrain
Averaging time for reports Terrain and bund definition
Indoor toxic calculations

Type of pool Specify the


Type of terrain for substrate and downwind
IDLH [30 mins] STEL [15 mins] dispersion bunds building type

Open
Open
Open
Open
Open
Toxic parameters
or toxic calculations Exposure time data Toxic conto
Cut-off fraction of Cut-off
Building type Set averaging time toxic load for concentration for
(downwind equal to exposure exposure time exposure time Number of toxic
building type) time calculation calculations levels
fraction fraction

Open
Open
Open
Open
Open
rs Explosion para
Toxic contours Explosion method

Dose levels Probit levels Lethality levels Explosion method


fraction

Open
Open
Open
Open
Open
Explosion parameters
Ignition Vapour liquid method
Multi-Energy: User-defined

Use explosion Explosion mass


Supply late Location of late mass modification modification Unconfined
ignition location ignition factor factor explosion strength
m

Open
Open
Open
Open
Open
Multi-Energy
Energy: User-defined Confined explosion sources

Unconfined Option for


explosion Number of specifying size of Strength of Volume of
efficiency confined sources confined sources confined source confined source
% m3

Open
Open
Open
Open
Open
Baker-Strehlow-Tang
ces Flame speed option Calculated flame speed

User specified
Volume fraction Mach number flame Mach
of confined source supplied number Flame expansion Obstacle density
fraction

Open
Open
Open
Open
Open
ehlow-Tang TNT
flame speed Ground correction factor TNT parameters

Default TNT
Correction for the The confined Air or ground explosion
Fuel reactivity ground effect volume burst efficiency
m3 fraction

Open
Open
Open
Open
Open
Fireball
Result types to calculate Radiation levels

Number of input
Calculate probit Calculate dose Calculate lethality radiation levels Intensity levels
kW/m2

Open
Open
Open
Open
Open
Fireball
Radiation levels Parameters Calculation method

Mass modification
Probit levels Dose levels Lethality levels factor Fireball model
fraction

Open
Open
Open
Open
Open
lculation method Jet fire method Result types to calculate

TNO model flame


temperature Jet fire method Calculate probit Calculate dose Calculate lethality
degC

Open
Open
Open
Open
Open
Jet fire
Radiation levels

Number of input
radiation levels Intensity levels Probit levels Dose levels Lethality levels
kW/m2 fraction

Open
Open
Open
Open
Open
Parameters Cone model data Surface emissive po
Calculation
Flame-shape method for
Rate modification adjustment if surface emissive
factor Correlation Horizontal options grounded power

Open
Open
Open
Open
Open
Po
Surface emissive power Result types to calculate

Flame emissive
power Emissivity fraction Calculate probit Calculate dose Calculate lethality
kW/m2 fraction

Open
Open
Open
Open
Open
Pool fire
Radiation levels

Number of input
radiation levels Intensity levels Probit levels Dose levels Lethality levels
kW/m2 fraction

Open
Open
Open
Open
Open
Parameters

Radiative fraction for


general fires
fraction

Open
Open
Open
Open
Open
Atmospheric
Use Study Folder Pressure vessel Folder storage tank

Open
Scenari
Scenario Hole

Use specified
Duration for fixed discharge
Folder Name duration release Orifice diameter coefficient?
s mm

Open
Scenario
Hole Release location Direction

Discharge Outdoor release Outdoor release


coefficient Elevation Tank head direction angle
fraction m m deg

Open
Material Discharge parameters
Material Phase Model settings

Atmospheric Phase change


Phase to be expansion upstream of
Material to track released method orifice?

Open
scharge parameters
Droplet break-up mechanism Dispersion scope

Averaging time for


Concentration of concentration of
Droplet break-up mechanism - continuous interest interest
ppm

Open
Dispersion
ispersion scope Distances of interest Averaging time for rep

Specify user-
defined averaging User defined
time averaging time Distances of interest ERPG [1 hr]
s m

Open
Bund, building and terrain
Averaging time for reports Terrain and bund definition
Indoor toxic calculations

Type of pool Specify the


Type of terrain for substrate and downwind
IDLH [30 mins] STEL [15 mins] dispersion bunds building type

Open
Toxic parameters
or toxic calculations Exposure time data Toxic conto
Cut-off fraction of Cut-off
Building type Set averaging time toxic load for concentration for
(downwind equal to exposure exposure time exposure time Number of toxic
building type) time calculation calculations levels
fraction fraction

Open
rs Explosion para
Toxic contours Explosion method

Dose levels Probit levels Lethality levels Explosion method


fraction

Open
Explosion parameters
Ignition Vapour liquid method
Multi-Energy: User-defined

Use explosion Explosion mass


Supply late Location of late mass modification modification Unconfined
ignition location ignition factor factor explosion strength
m

Open
Multi-Energy
Energy: User-defined Confined explosion sources

Unconfined Option for


explosion Number of specifying size of Strength of Volume of
efficiency confined sources confined sources confined source confined source
% m3

Open
Baker-Strehlow-Tang
ces Flame speed option Calculated flame speed

User specified
Volume fraction Mach number flame Mach
of confined source supplied number Flame expansion Obstacle density
fraction

Open
ehlow-Tang TNT
flame speed Ground correction factor TNT parameters

Default TNT
Correction for the The confined Air or ground explosion
Fuel reactivity ground effect volume burst efficiency
m3 fraction

Open
Fireball
Result types to calculate Radiation levels

Number of input
Calculate probit Calculate dose Calculate lethality radiation levels Intensity levels
kW/m2

Open
Fireball
Radiation levels Parameters Calculation method

Mass modification
Probit levels Dose levels Lethality levels factor Fireball model
fraction

Open
lculation method Jet fire method Result types to calculate

TNO model flame


temperature Jet fire method Calculate probit Calculate dose Calculate lethality
degC

Open
Jet fire
Radiation levels

Number of input
radiation levels Intensity levels Probit levels Dose levels Lethality levels
kW/m2 fraction

Open
Parameters Cone model data Surface emissive po
Calculation
Flame-shape method for
Rate modification adjustment if surface emissive
factor Correlation Horizontal options grounded power

Open
Po
Surface emissive power Result types to calculate

Flame emissive
power Emissivity fraction Calculate probit Calculate dose Calculate lethality
kW/m2 fraction

Open
Pool fire
Radiation levels

Number of input
radiation levels Intensity levels Probit levels Dose levels Lethality levels
kW/m2 fraction

Open
Parameters

Radiative fraction for


general fires
fraction

Open
Atmospheric
Use Study Folder Pressure vessel Folder storage tank

Open
Scenario Pipe dimensions

Pipe internal
Folder Name Scenario type diameter Pipe length
mm m

Open
Scenario
Hole Release location Flow control

Orifice diameter Elevation Tank head Flow controller Input option


mm m m

Open
Material
Flow control Direction Material

Outdoor release Outdoor release


Fixed flow rate Pump head direction angle Material to track
kg/s m deg

Open
Material Discharge parameters
Phase Model settings
Droplet break-up mechanism

Phase to be Droplet break-up Droplet break-up


Phase to be released for 2- Atmospheric expansion mechanism - mechanism -
released phase vessels method instantaneous continuous

Open
Short pipe
Pipe characteristics Frequencies

Frequency of Frequency of Frequency of


Pipe roughness bends in pipe couplings in pipe junctions in pipe
mm /m /m /m

Open
Short pipe
Frequencies of valves Velocity head losses

Excess flow valve Non-return valve


Frequency of Frequency of non- Frequency of velocity head velocity head
excess flow valves return valves shut-off valves losses losses
/m /m /m

Open
Dispersion
head losses Dispersion scope

Shut-off valve Averaging time for Specify user-


velocity head Concentration of concentration of defined averaging User defined
losses interest interest time averaging time
ppm s

Open
Dispersion
Distances of interest Averaging time for reports

Distances of interest ERPG [1 hr] IDLH [30 mins] STEL [15 mins]
m

Open
Bund, building and terrain Toxic pa
Terrain and bund definition
Indoor toxic calculations Exposure time data

Type of pool Specify the Building type Set averaging time


Type of terrain for substrate and downwind (downwind equal to exposure
dispersion bunds building type building type) time

Open
Toxic parameters
Exposure time data Toxic contours
Cut-off fraction of Cut-off
toxic load for concentration for
exposure time exposure time Number of toxic
calculation calculations levels Dose levels Probit levels
fraction fraction

Open
Explosion parameters
urs Explosion method Ignition

Supply late Location of late


Lethality levels Explosion method ignition location ignition
fraction m

Open
rameters Multi-Energy
Vapour liquid method
Multi-Energy: User-defined Confined ex

Use explosion Explosion mass Unconfined


mass modification modification Unconfined explosion Number of
factor factor explosion strength efficiency confined sources
%

Open
Multi-Energy B
Confined explosion sources Flame speed option

Option for
specifying size of Strength of Volume of Volume fraction Mach number
confined sources confined source confined source of confined source supplied
m3 fraction

Open
Baker-Strehlow-Tang
me speed option Calculated flame speed Ground correction factor

User specified
flame Mach Correction for the
number Flame expansion Obstacle density Fuel reactivity ground effect

Open
TNT
nd correction factor TNT parameters Result types to calculate

Default TNT
The confined Air or ground explosion
volume burst efficiency Calculate probit Calculate dose
m3 fraction

Open
Fireball
es to calculate Radiation levels

Number of input
Calculate lethality radiation levels Intensity levels Probit levels Dose levels
kW/m2

Open
Parameters Calculation method

Mass modification TNO model flame


Lethality levels factor Fireball model temperature
fraction degC

Open
Jet fire method Result types to calculate

Number of input
Jet fire method Calculate probit Calculate dose Calculate lethality radiation levels

Open
Jet fire
Radiation levels Parameters

Rate modification
Intensity levels Probit levels Dose levels Lethality levels factor
kW/m2 fraction

Open
Cone model data Surface emissive power
Calculation
Flame-shape method for
adjustment if surface emissive Flame emissive
Correlation Horizontal options grounded power power
kW/m2

Open
Pool fire
missive power Result types to calculate Radiati

Number of input
Emissivity fraction Calculate probit Calculate dose Calculate lethality radiation levels
fraction

Open
Pool fire
Radiation levels Parameters

Radiative fraction for


Intensity levels Probit levels Dose levels Lethality levels general fires
kW/m2 fraction fraction

Open
Atmospheric
Use Study Folder Pressure vessel Folder storage tank

Open
Sce
Hole

Use specified
discharge Discharge
Folder Name Orifice diameter coefficient? coefficient
mm fraction

Open
Scenario
Release location Pump head Direction

Release height
from vessel Specify pump Outdoor release
Elevation bottom head? Pump head direction
m m m

Open
Material Discharge paramet
Direction Material Phase Model settings

Atmospheric Phase change


Outdoor release Phase to be expansion upstream of
angle Material to track released method orifice?
deg

Open
scharge parameters Time v
Droplet break-up mechanism Time averagin

Method for
Duration of calculating
Droplet break-up mechanism - continuous interest average rate
s

Open
Time varying releases
Time averaging Modelling of time-varying leaks and line

Time at which First time value Second time value


Expected number release rate is for rate between for rate between Vacuum relief
of average rates calculated two times two times valve
s s s

Open
Dispersion
-varying leaks and line ruptures Dispersion scope

Averaging time for Specify user-


Vacuum relief Concentration of concentration of defined averaging User defined
valve set point interest interest time averaging time
bar ppm s

Open
Dispersion
Distances of interest Averaging time for reports

Distances of interest ERPG [1 hr] IDLH [30 mins] STEL [15 mins]
m

Open
Bund, building and terrain Toxic pa
Terrain and bund definition
Indoor toxic calculations Exposure time data

Type of pool Specify the Building type Set averaging time


Type of terrain for substrate and downwind (downwind equal to exposure
dispersion bunds building type building type) time

Open
Toxic parameters
Exposure time data Toxic contours
Cut-off fraction of Cut-off
toxic load for concentration for
exposure time exposure time Number of toxic
calculation calculations levels Dose levels Probit levels
fraction fraction

Open
Explosion parameters
urs Explosion method Ignition

Supply late Location of late


Lethality levels Explosion method ignition location ignition
fraction m

Open
rameters Multi-Energy
Vapour liquid method
Multi-Energy: User-defined Confined ex

Use explosion Explosion mass Unconfined


mass modification modification Unconfined explosion Number of
factor factor explosion strength efficiency confined sources
%

Open
Multi-Energy B
Confined explosion sources Flame speed option

Option for
specifying size of Strength of Volume of Volume fraction Mach number
confined sources confined source confined source of confined source supplied
m3 fraction

Open
Baker-Strehlow-Tang
me speed option Calculated flame speed Ground correction factor

User specified
flame Mach Correction for the
number Flame expansion Obstacle density Fuel reactivity ground effect

Open
TNT
nd correction factor TNT parameters Result types to calculate

Default TNT
The confined Air or ground explosion
volume burst efficiency Calculate probit Calculate dose
m3 fraction

Open
Fireball
es to calculate Radiation levels

Number of input
Calculate lethality radiation levels Intensity levels Probit levels Dose levels
kW/m2

Open
Parameters Calculation method

Mass modification TNO model flame


Lethality levels factor Fireball model temperature
fraction degC

Open
Jet fire method Result types to calculate

Number of input
Jet fire method Calculate probit Calculate dose Calculate lethality radiation levels

Open
Jet fire
Radiation levels Parameters

Rate modification
Intensity levels Probit levels Dose levels Lethality levels factor
kW/m2 fraction

Open
Cone model data Surface emissive power
Calculation
Flame-shape method for
adjustment if surface emissive Flame emissive
Correlation Horizontal options grounded power power
kW/m2

Open
Pool fire
missive power Result types to calculate Radiati

Number of input
Emissivity fraction Calculate probit Calculate dose Calculate lethality radiation levels
fraction

Open
Pool fire
Radiation levels Parameters

Radiative fraction for


Intensity levels Probit levels Dose levels Lethality levels general fires
kW/m2 fraction fraction

Open
Atmospheric
Use Study Folder Pressure vessel Folder storage tank

Open
Scenario Pipe dimensions

Pipe internal
Folder Name Scenario type diameter Pipe length
mm m

Open
Scenario
Hole Release location Pump head

Release height
from vessel Specify pump
Orifice diameter Elevation Tank head bottom head?
mm m m m

Open
Material
Pump head Direction Material Phase

Outdoor release Outdoor release Phase to be


Pump head direction angle Material to track released
m deg

Open
terial Discharge parameters
Phase Model settings

Phase to be Atmospheric Phase change


released for 2- expansion upstream of
phase vessels method orifice?

Open
scharge parameters
Droplet break-up mechanism Pipe characteristics

Droplet break-up mechanism - continuous Pipe roughness


mm

Open
Short pipe
Frequencies Frequencies of valves

Frequency of Frequency of Frequency of Frequency of Frequency of non-


bends in pipe couplings in pipe junctions in pipe excess flow valves return valves
/m /m /m /m /m

Open
ies of valves Velocity head losses

Excess flow valve Non-return valve Shut-off valve


Frequency of velocity head velocity head velocity head Duration of
shut-off valves losses losses losses interest
/m s

Open
Time varying releases
Time averaging

Method for Time at which First time value Second time value
calculating Expected number release rate is for rate between for rate between
average rate of average rates calculated two times two times
s s s

Open
Disp
lling of time-varying leaks and line ruptures Dispersion scope

Averaging time for Specify user-


Vacuum relief Vacuum relief Concentration of concentration of defined averaging
valve valve set point interest interest time
bar ppm

Open
Dispersion
ope Distances of interest Averaging time for reports

User defined
averaging time Distances of interest ERPG [1 hr] IDLH [30 mins]
s m

Open
Bund, building and terrain
me for reports Terrain and bund definition
Indoor toxic calculations

Type of pool Specify the Building type


Type of terrain for substrate and downwind (downwind
STEL [15 mins] dispersion bunds building type building type)

Open
Toxic parameters
Exposure time data Toxic contours
Cut-off fraction of Cut-off
Set averaging time toxic load for concentration for
equal to exposure exposure time exposure time Number of toxic
time calculation calculations levels Dose levels
fraction fraction

Open
Explosion parameters
Toxic contours Explosion method Ignition

Supply late
Probit levels Lethality levels Explosion method ignition location
fraction

Open
osion parameters Multi
Ignition Vapour liquid method
Multi-Energy: User-defined

Use explosion Explosion mass Unconfined


Location of late mass modification modification Unconfined explosion
ignition factor factor explosion strength efficiency
m %

Open
Multi-Energy
Confined explosion sources

Option for
Number of specifying size of Strength of Volume of Volume fraction
confined sources confined sources confined source confined source of confined source
m3 fraction

Open
Baker-Strehlow-Tang
Flame speed option Calculated flame speed

User specified
Mach number flame Mach
supplied number Flame expansion Obstacle density Fuel reactivity

Open
ang TNT
Ground correction factor TNT parameters Result types to calcula

Default TNT
Correction for the The confined Air or ground explosion
ground effect volume burst efficiency Calculate probit
m3 fraction

Open
Fireball
Result types to calculate Radiation levels

Number of input
Calculate dose Calculate lethality radiation levels Intensity levels Probit levels
kW/m2

Open
reball
tion levels Parameters Calculation method

Mass modification TNO model flame


Dose levels Lethality levels factor Fireball model temperature
fraction degC

Open
Jet fire method Result types to calculate

Number of input
Jet fire method Calculate probit Calculate dose Calculate lethality radiation levels

Open
Jet fire
Radiation levels Parameters

Rate modification
Intensity levels Probit levels Dose levels Lethality levels factor
kW/m2 fraction

Open
Cone model data Surface emissive power
Calculation
Flame-shape method for
adjustment if surface emissive Flame emissive
Correlation Horizontal options grounded power power
kW/m2

Open
Pool fire
missive power Result types to calculate Radiati

Number of input
Emissivity fraction Calculate probit Calculate dose Calculate lethality radiation levels
fraction

Open
Pool fire
Radiation levels Parameters

Radiative fraction for


Intensity levels Probit levels Dose levels Lethality levels general fires
kW/m2 fraction fraction

Open
Atmospheric
Use Study Folder Pressure vessel Folder storage tank

Open
Release scenario

The number of
Folder Name Release scenario release observers Release time
s

Open
Scenario
Release observers

Release phase Mass flow Final velocity Final temperature Liquid fraction
kg/s m/s degC fraction

Open
Scenario
Release location

Pre-dilution air
Droplet diameter Pool radius rate Elevation Tank head
um m kg/s m m

Open
Material
Direction Fireball emissive power Material

Outdoor release Outdoor release Use vessel burst Vessel burst


direction angle pressure pressure - gauge Material to track
deg bar

Open
Dispersion
Dispersion scope

Averaging time for Specify user-


Concentration of concentration of defined averaging User defined
interest interest time averaging time
ppm s

Open
Dispersion
Distances of interest Averaging time for reports

Distances of interest ERPG [1 hr] IDLH [30 mins] STEL [15 mins]
m

Open
Bund, building and terrain Toxic pa
Terrain and bund definition
Indoor toxic calculations Exposure time data

Type of pool Specify the Building type Set averaging time


Type of terrain for substrate and downwind (downwind equal to exposure
dispersion bunds building type building type) time

Open
Toxic parameters
Exposure time data Toxic contours
Cut-off fraction of Cut-off
toxic load for concentration for
exposure time exposure time Number of toxic
calculation calculations levels Dose levels Probit levels
fraction fraction

Open
Explosion parameters
urs Explosion method Ignition

Supply late Location of late


Lethality levels Explosion method ignition location ignition
fraction m

Open
rameters Multi-Energy
Vapour liquid method
Multi-Energy: User-defined Confined ex

Use explosion Explosion mass Unconfined


mass modification modification Unconfined explosion Number of
factor factor explosion strength efficiency confined sources
%

Open
Multi-Energy B
Confined explosion sources Flame speed option

Option for
specifying size of Strength of Volume of Volume fraction Mach number
confined sources confined source confined source of confined source supplied
m3 fraction

Open
Baker-Strehlow-Tang
me speed option Calculated flame speed Ground correction factor

User specified
flame Mach Correction for the
number Flame expansion Obstacle density Fuel reactivity ground effect

Open
TNT
nd correction factor TNT parameters Result types to calculate

Default TNT
The confined Air or ground explosion
volume burst efficiency Calculate probit Calculate dose
m3 fraction

Open
Fireball
es to calculate Radiation levels

Number of input
Calculate lethality radiation levels Intensity levels Probit levels Dose levels
kW/m2

Open
Parameters Calculation method

Mass modification TNO model flame


Lethality levels factor Fireball model temperature
fraction degC

Open
Jet fire method Result types to calculate

Number of input
Jet fire method Calculate probit Calculate dose Calculate lethality radiation levels

Open
Jet fire
Radiation levels Parameters

Rate modification
Intensity levels Probit levels Dose levels Lethality levels factor
kW/m2 fraction

Open
Cone model data Surface emissive power
Calculation
Flame-shape method for
adjustment if surface emissive Flame emissive
Correlation Horizontal options grounded power power
kW/m2

Open
Pool fire
missive power Result types to calculate Radiati

Number of input
Emissivity fraction Calculate probit Calculate dose Calculate lethality radiation levels
fraction

Open
Pool fire
Radiation levels Parameters

Radiative fraction for


Intensity levels Probit levels Dose levels Lethality levels general fires
kW/m2 fraction fraction

Open
Atmospheric
Use Study Folder storage tank Folder Name

Open
Scenario
Release scenario Release observers

The number of
Release scenario release observers Release time Mass flow Final temperature
s kg/s degC

Open
Material Disp
Material Phase Dispersion scope

Averaging time for Specify user-


Phase to be Concentration of concentration of defined averaging
Material to track released interest interest time
ppm

Open
Dispersion
ope Distances of interest Averaging time for reports

User defined
averaging time Distances of interest ERPG [1 hr] IDLH [30 mins]
s m

Open
Bund, building and terrain
me for reports Terrain and bund definition
Indoor toxic calculations

Type of pool Specify the Building type


Type of terrain for substrate and downwind (downwind
STEL [15 mins] dispersion bunds building type building type)

Open
Toxic parameters
Exposure time data Toxic contours
Cut-off fraction of Cut-off
Set averaging time toxic load for concentration for
equal to exposure exposure time exposure time Number of toxic
time calculation calculations levels Dose levels
fraction fraction

Open
Explosion parameters
Toxic contours Explosion method Ignition

Supply late
Probit levels Lethality levels Explosion method ignition location
fraction

Open
osion parameters Multi
Ignition Vapour liquid method
Multi-Energy: User-defined

Use explosion Explosion mass Unconfined


Location of late mass modification modification Unconfined explosion
ignition factor factor explosion strength efficiency
m %

Open
Multi-Energy
Confined explosion sources

Option for
Number of specifying size of Strength of Volume of Volume fraction
confined sources confined sources confined source confined source of confined source
m3 fraction

Open
Baker-Strehlow-Tang
Flame speed option Calculated flame speed

User specified
Mach number flame Mach
supplied number Flame expansion Obstacle density Fuel reactivity

Open
ang TNT
Ground correction factor TNT parameters Result types to calcula

Default TNT
Correction for the The confined Air or ground explosion
ground effect volume burst efficiency Calculate probit
m3 fraction

Open
Pool fire
Result types to calculate Radiation levels

Number of input
Calculate dose Calculate lethality radiation levels Intensity levels Probit levels
kW/m2

Open
tion levels Parameters

Radiative fraction for


Dose levels Lethality levels general fires
fraction fraction

Open
Atmospheric
Use Study Folder storage tank Folder Name

Open
Scenario
Scenario Release location Direction

Outdoor release
Gas volume flow Vent diameter Elevation Tank head direction
m3/hr mm m m

Open
Material
Direction Material Phase Dispersion scope

Averaging time for


Outdoor release Phase to be Concentration of concentration of
angle Material to track released interest interest
deg ppm

Open
Dispersion
ispersion scope Distances of interest Averaging time for rep

Specify user-
defined averaging User defined
time averaging time Distances of interest ERPG [1 hr]
s m

Open
Bund, building and terrain
Averaging time for reports Terrain and bund definition
Indoor toxic calculations

Type of pool Specify the


Type of terrain for substrate and downwind
IDLH [30 mins] STEL [15 mins] dispersion bunds building type

Open
Toxic parameters
or toxic calculations Exposure time data Toxic conto
Cut-off fraction of Cut-off
Building type Set averaging time toxic load for concentration for
(downwind equal to exposure exposure time exposure time Number of toxic
building type) time calculation calculations levels
fraction fraction

Open
rs Explosion para
Toxic contours Explosion method

Dose levels Probit levels Lethality levels Explosion method


fraction

Open
Explosion parameters
Ignition Vapour liquid method
Multi-Energy: User-defined

Use explosion Explosion mass


Supply late Location of late mass modification modification Unconfined
ignition location ignition factor factor explosion strength
m

Open
Multi-Energy
Energy: User-defined Confined explosion sources

Unconfined Option for


explosion Number of specifying size of Strength of Volume of
efficiency confined sources confined sources confined source confined source
% m3

Open
Baker-Strehlow-Tang
ces Flame speed option Calculated flame speed

User specified
Volume fraction Mach number flame Mach
of confined source supplied number Flame expansion Obstacle density
fraction

Open
ehlow-Tang TNT
flame speed Ground correction factor TNT parameters

Default TNT
Correction for the The confined Air or ground explosion
Fuel reactivity ground effect volume burst efficiency
m3 fraction

Open
Fireball
Result types to calculate Radiation levels

Number of input
Calculate probit Calculate dose Calculate lethality radiation levels Intensity levels
kW/m2

Open
Fireball
Radiation levels Parameters Calculation method

Mass modification
Probit levels Dose levels Lethality levels factor Fireball model
fraction

Open
lculation method Jet fire method Result types to calculate

TNO model flame


temperature Jet fire method Calculate probit Calculate dose Calculate lethality
degC

Open
Jet fire
Radiation levels

Number of input
radiation levels Intensity levels Probit levels Dose levels Lethality levels
kW/m2 fraction

Open
Parameters Cone model data Surface emissive po
Calculation
Flame-shape method for
Rate modification adjustment if surface emissive
factor Correlation Horizontal options grounded power

Open
Surface emissive power

Flame emissive
power Emissivity fraction
kW/m2 fraction

Open
Release d

Use Study Folder Standalones Folder Name

Open
Release data Distances TNT
Release data Distances of interest for graph TNT parameters

Minimum Maximum Air or ground


Flammable mass in cloud distance distance Step size burst
kg m m m

Open
TNT
NT parameters

Default TNT
explosion
efficiency
fraction

Open
Use Study Folder Standalones Folder Name

Open
Multi-Energy
Release massMulti-Energy: User-defined Confined explosion

Unconfined Option for


Unconfined explosion Number of specifying size of
Flammable mass in cloud explosion strength efficiency confined sources confined sources
kg %

Open
gy Distances
Confined explosion sources Distances of interest for graph

Strength of Volume of Volume fraction Minimum Maximum


confined source confined source of confined source distance distance
m3 fraction m m

Open
ances
nterest for graph

Step size
m

Open
Use Study Folder Standalones Folder Name

Open
Baker-Strehlow-Tang
Release mass Flame speed option Calculated flame speed

User specified
Mach number flame Mach
Flammable mass in cloud supplied number Flame expansion Obstacle density
kg

Open
ow-Tang Distances
flame speed Ground correction factor Distances of interest for graph

Minimum Maximum
Fuel reactivity Correction for the ground effect distance distance
m m

Open
ances
nterest for graph

Step size
m

Open
Use Study Folder Standalones Folder Name

Open
Storage conditio
Vessel Phase

Specified
Shape Elevation Radius Length condition
m m m

Open
Storage conditions
Phase Material

Liquid fraction Specify volume


Temperature Pressure (gauge) mass inventory? Mass inventory
degC bar fraction kg

Open
Distances
aterial Distances of interest

Max. distance Minimum Maximum


Volume inventory option distance distance Step size
m3 m m m

Open
BLEVE blast parameters
BLEVE blast parameters

Number of Air or ground Ideal gas


distance points burst modelling Model option

Open
Use Study Folder Standalones Folder Name

Open
Fireball
Released mass Burst pressure Surface emissive power

Calculate flame
Vapour mass Supply burst Burst pressure - surface emissive
Released mass fraction pressure - gauge gauge power
kg fraction bar

Open
eball Fireb
ace emissive power Flame shape definition Radiation levels

Flame surface Use shape Number of input


emissive power Fireball radius Fireball duration correlation radiation levels
kW/m2 m s

Open
Fireball parameters
Radiation levels Parameters Calculation method

Mass modification Fireball maximum TNO model flame


Intensity levels factor exposure duration Fireball model temperature
kW/m2 s degC

Open
Radiation calculations R
Type of radiation results required Point location

Distance away
Radiation at a Radiation vs Radiation from release
point distance Radiation ellipse contours direction
m

Open
Radiation at a point
Point location Observer

Distance
perpendicular to Height above
release direction origin Fixed inclination? Inclination Fixed orientation?
m m deg

Open
Radiation vs distance
Transect Observe

Orientation about Maximum Angle from Height above


the z-axis distance release direction origin Fixed inclination?
deg m deg m

Open
vs distance Radiation ellips
Observer Ellipse

Orientation about Ellipse type Specified


Inclination Fixed orientation? the z-axis required radiation intensity
deg deg kW/m2

Open
Radiation ellipse
lipse Observer Display Contour footprint

Generate
Specified lethality Chart type being radiation
level Fixed inclination? Inclination plotted footprint?
fraction deg

Open
R
ontour footprint Contour side view Contour cross-section

Generate Distance Generate Distance


Height above radiation side crosswind of radiation cross- downwind of
origin view? release source section? release source
m m m

Open
Radiation contours
User-defined contour plane User-defined contour plane origin

Specify user-defined contour plane? X Y Z


m m m

Open
User-defined contour plane X axis User-defined contour plane Y axis

X Y Z X Y
m m m m m

Open
ntour plane Y axis

Z
m

Open
Use Study Folder Standalones Folder Name

Open
Jet fire
Jet fire model Release location Release

Calculate jet Mass discharge


Jet fire model type Elevation of discharge point velocity? rate
m kg/s

Open
Jet fire
Release characteristics

Two-phase Post-expansion Post-expansion jet Expanded


release? liquid fraction temperature Jet velocity diameter
fraction degC m/s m

Open
Cone model data API model data
Cone model data API model data

Use flame length


Inclination of jet from horizontal Jet direction Flame length correlation?
deg m

Open
data Jet fire p
ata Radiation levels Cone model data

Calculate the
expanded Number of input
diameter? radiation levels Intensity levels Crosswind angle Horizontal options
kW/m2 deg

Open
Jet fire parameters
one model data Surface emissive power
Calculation
Flame-shape method for
adjustment if surface emissive Flame emissive
Correlation grounded power power Emissivity fraction
kW/m2 fraction

Open
Radiation calculations
Exposure duration Type of radiation results required

Jet fire maximum exposure Radiation at a Radiation vs


duration point distance Radiation ellipse
s

Open
ulations Radiation at a point
ults required Point location Observe

Distance away Distance


Radiation from release perpendicular to Height above
contours direction release direction origin Fixed inclination?
m m m

Open
n at a point Radiation
Observer Transect

Orientation about Maximum Angle from


Inclination Fixed orientation? the z-axis distance release direction
deg deg m deg

Open
Radiation vs distance
nsect Observer

Height above Orientation about


origin Fixed inclination? Inclination Fixed orientation? the z-axis
m deg deg

Open
Radiation ellipse
Ellipse Observer

Ellipse type Specified Specified lethality


required radiation intensity level Fixed inclination? Inclination
kW/m2 fraction deg

Open
Display Contour footprint Contour side view

Generate Generate Distance


Chart type being radiation Height above radiation side crosswind of
plotted footprint? origin view? release source
m m

Open
Radiation contours
Contour cross-section User-defined contour plane User-defined conto

Generate Distance
radiation cross- downwind of
section? release source Specify user-defined contour plane? X
m m

Open
ours
r-defined contour plane origin User-defined contour plane X axis

Y Z X Y Z
m m m m m

Open
User-defined contour plane Y axis

X Y Z
m m m

Open
Use Study Folder Standalones Folder Name

Open
Pool fire
Pool dimensions and flame shape

Calculate flame Flame angle to


Pool diameter length and angle? Flame length vertical Elevation
m m deg m

Open
e Pool fire parameters
e Radiation Radiation levels

Calculate flame Number of input


Base surface emissivity? Flame emissivity radiation levels Intensity levels
kW/m2 kW/m2

Open
fire parameters Radiation calculations
Parameters Type of radiation results required

Pool fire
maximum Radiative fraction Radiation at a Radiation vs
exposure duration for general fires point distance Radiation ellipse
s fraction

Open
ulations Radiation at a point
ults required Point location Observe

Distance away Distance


Radiation from release perpendicular to Height above
contours direction release direction origin Fixed inclination?
m m m

Open
n at a point Radiation
Observer Transect

Orientation about Maximum Angle from


Inclination Fixed orientation? the z-axis distance release direction
deg deg m deg

Open
Radiation vs distance
nsect Observer

Height above Orientation about


origin Fixed inclination? Inclination Fixed orientation? the z-axis
m deg deg

Open
Radiation ellipse
Ellipse Observer

Ellipse type Specified Specified lethality


required radiation intensity level Fixed inclination? Inclination
kW/m2 fraction deg

Open
Display Contour footprint Contour side view

Generate Generate Distance


Chart type being radiation Height above radiation side crosswind of
plotted footprint? origin view? release source
m m

Open
Radiation contours
Contour cross-section User-defined contour plane User-defined conto

Generate Distance
radiation cross- downwind of
section? release source Specify user-defined contour plane? X
m m

Open
ours
r-defined contour plane origin User-defined contour plane X axis

Y Z X Y Z
m m m m m

Open
User-defined contour plane Y axis

X Y Z
m m m

Open
Use Study Folder Standalones Folder Name

Open
Pool vaporisation
Spill data

Type of spill Spill temperature Spill rate Spill mass Spill duration
degC kg/s kg s

Open
MaterialBund, building and terrain
Limits Modelling of mixturesTerrain and bund definition

Type of pool
Maximum time of Type of terrain for substrate and
interest Multi or pseudo-component modelling dispersion bunds
s

Open
Open
Breach data

Breach sizing
Use Study Folder Long pipeline Name method

Open
Scenario
Breach data Release location Direction

Relative branch Outdoor release


Hole diameter aperture (area) Distance to break Elevation direction
mm fraction m m

Open
Material Disch
Direction Crater modelling Material Phase Model settings

Atmospheric
Outdoor release Phase to be expansion
angle Accident type Material to track released method
deg

Open
Discharge parameters Long pipe
Model settings Droplet break-up mechanism Crater modelling

Phase change
upstream of
orifice? Droplet break-up mechanism - continuous Fracture length
m

Open
Time varying releases
Time averaging

Method for Time at which First time value


Duration of calculating Expected number release rate is for rate between
interest average rate of average rates calculated two times
s s s

Open
Dispersion
Dispersion scope

Second time value Averaging time for Specify user-


for rate between Concentration of concentration of defined averaging User defined
two times interest interest time averaging time
s ppm s

Open
Dispersion
Distances of interest Averaging time for reports

Distances of interest ERPG [1 hr] IDLH [30 mins] STEL [15 mins]
m

Open
Bund, building and terrain Toxic pa
Terrain and bund definition
Indoor toxic calculations Exposure time data

Type of pool Specify the Building type Set averaging time


Type of terrain for substrate and downwind (downwind equal to exposure
dispersion bunds building type building type) time

Open
Toxic parameters
Exposure time data Toxic contours
Cut-off fraction of Cut-off
toxic load for concentration for
exposure time exposure time Number of toxic
calculation calculations levels Dose levels Probit levels
fraction fraction

Open
Explosion parameters
urs Explosion method Ignition

Supply late Location of late


Lethality levels Explosion method ignition location ignition
fraction m

Open
rameters Multi-Energy
Vapour liquid method
Multi-Energy: User-defined Confined ex

Use explosion Explosion mass Unconfined


mass modification modification Unconfined explosion Number of
factor factor explosion strength efficiency confined sources
%

Open
Multi-Energy B
Confined explosion sources Flame speed option

Option for
specifying size of Strength of Volume of Volume fraction Mach number
confined sources confined source confined source of confined source supplied
m3 fraction

Open
Baker-Strehlow-Tang
me speed option Calculated flame speed Ground correction factor

User specified
flame Mach Correction for the
number Flame expansion Obstacle density Fuel reactivity ground effect

Open
TNT
nd correction factor TNT parameters Result types to calculate

Default TNT
The confined Air or ground explosion
volume burst efficiency Calculate probit Calculate dose
m3 fraction

Open
Fireball
es to calculate Radiation levels

Number of input
Calculate lethality radiation levels Intensity levels Probit levels Dose levels
kW/m2

Open
Parameters Calculation method

Mass modification TNO model flame


Lethality levels factor Fireball model temperature
fraction degC

Open
Jet fire method Result types to calculate

Number of input
Jet fire method Calculate probit Calculate dose Calculate lethality radiation levels

Open
Jet fire
Radiation levels Parameters

Rate modification
Intensity levels Probit levels Dose levels Lethality levels factor
kW/m2 fraction

Open
Cone model data Surface emissive power
Calculation
Flame-shape method for
adjustment if surface emissive Flame emissive
Correlation Horizontal options grounded power power
kW/m2

Open
Pool fire
missive power Result types to calculate Radiati

Number of input
Emissivity fraction Calculate probit Calculate dose Calculate lethality radiation levels
fraction

Open
Pool fire
Radiation levels Parameters

Radiative fraction for


Intensity levels Probit levels Dose levels Lethality levels general fires
kW/m2 fraction fraction

Open
General
Weather directions

Selection of
Number of directions to
Use Name directions Angular offset analyse
deg
Yes Weather folder 1

Open
Weather
Weather conditions General atmospheric p

Atmospheric
Use Weather folder Name Wind speed Pasquill stability temperature
m/s degC
Yes Weather folder Category 1.5/F 1.5 9 F stable - night with moderate clouds and light/modera
Yes Weather folder Category 1.5/D 1.5 7 D neutral - little sun and high wind or overcast/windy n
Yes Weather folder Category 5/D 5 7 D neutral - little sun and high wind or overcast/windy n

Open
Atmospher
neral atmospheric parameters Mixing layer

Mixing layer Mixing layer Mixing layer


Solar radiation height for Pasquill height for Pasquill height for Pasquill
Relative humidity flux stability A stability A/B stability B
fraction kW/m2 m m m
derate clouds and light/moderate wind
d high wind or overcast/windy night
d high wind or overcast/windy night

Open
Atmospheric parameters
Mixing layer height vs. Pasquill stability

Mixing layer Mixing layer Mixing layer Mixing layer Mixing layer
height for Pasquill height for Pasquill height for Pasquill height for Pasquill height for Pasquill
stability B/C stability C stability C/D stability D stability E
m m m m m

Open
Substrate data
Building data Surface temperature
Surface
Mixing layer Mixing layer temperature for
height for Pasquill height for Pasquill Building exchange dispersion
stability F stability G rate Tail time calculations
m m /hr s degC

Open
bstrate data
face temperature

Surface
temperature for
pool calculations
degC

Open
Discha
Capping options Short pipe

Velocity capping Maximum release Minimum RV


Use Parameter set Name method velocity diameter ratio
m/s
Yes Parameter set Discharge parameters

Open
Discharge constants
Short pipe modelling Equation constants

Critical pressure Continuous Instantaneous


Relief valve safety greater than flow Capping of pipe critical Weber critical Weber
factor phase flow rates number number
bar

Open
Reference
n constants Droplet handling Phase data

Venting equation Droplet method - continuous Minimum drop Maximum drop Default liquid
constant only diameter allowed diameter allowed fraction
um um fraction

Open
nce Scenario
a Short pipe modelling Release location

Use Bernoulli for


forced -phase liq-
liq discharge Tolerance Elevation
m

Open
Short pipe
Pipe characteristics Frequencies

Frequency of Frequency of Frequency of


Pipe roughness bends in pipe couplings in pipe junctions in pipe
mm /m /m /m

Open
Short pipe
Frequencies of valves Velocity head losses

Excess flow valve Non-return valve


Frequency of Frequency of non- Frequency of velocity head velocity head
excess flow valves return valves shut-off valves losses losses
/m /m /m

Open
Long pipe
head losses Long pipe

Shut-off valve Thermodynamic Maximum


velocity head Model heat option for gas Number of time number of data
losses transfer pipelines steps points

Open
e Time varying releases Discharge param
CraterModelling
modellingof time-varying leaks and line Model
ruptures
settings

Atmospheric Phase change


Vacuum relief Vacuum relief expansion upstream of
Fracture length valve valve set point method orifice?
m bar

Open
arge parameters
Droplet break-up mechanism

Droplet break-up Droplet break-up


mechanism - mechanism -
instantaneous continuous

Open
Model in use

Use Parameter set Name Model in use Lee length Lee half-width

Yes Parameter set Dispersion parameters

Open
Building wake
Calculation control

Specified lee Specified lee half-


Lee height K-factor Switch distance length width
m m

Open
Output granularity

Maximum
Specified lee Specified switch Maximum initial number of output
height Specified k-factor distance step size steps
m m m

Open
Momentum jet – continuous

Drag coefficient Expansion zone


between plume Jet entrainment Jet entrainment length/source
Jet model and air coefficient alpha1 coefficient alpha2 diameter ratio

Open
Near field
Initial energetic expansion – instantaneous
Kinetic-energy Ratio droplet/
Modelling of fraction of Air drag expansion
instantaneous discharge Rainout coefficient to velocity for inst.
expansion expansion energy coefficient radial expansion release
fraction

Open
neous Dense cloud

Expansion energy Dense cloud Dense cloud Dense cloud Dense cloud
cutoff for droplet parameter gamma parameter gamma parameter K - parameter K -
angle - continuous - instantaneous continuous instantaneous
kJ/kg

Open
Atmospheric entrainment Criteria for transition to passive dispersion
Maximum non-
Maximum Maximum passive
cloud/ambient cloud/ambient entrainment
Near field passive entrainment parameter velocity difference density difference fraction

Open
Far field
assive dispersion Modeling the transition Modeling passive dispersion

Maximum Ratio Ratio


Richardson Distance multiple for full passive instantaneous/co instantaneous/co
number entrainment ntinuous sigma-y ntinuous sigma-z

Open
Liquid
ssive dispersion End of dispersion Droplet modelling

Core averaging Criterion for halting dispersion Droplet evaporation


time model thermodynamics model
s

Open
Ground
Modelling of heat and water transfer Modelling of impingement

Impingement Impinged velocity


Flag for heat/water vapour transfer option limit
m/s

Open
Time-varyin
f impingement Cloud lift-off Observer release control

Impinged velocity Richardson number


factor criterion for cloud lift-off Suggested number of pool observers
fraction

Open
Time-varying and finite duration
Modelling of finite duration or time-varying dispersion
Quasi-
Method for non- instantaneous Minimum release
instantaneous transition Time averaging Observer mass duration for time-
dispersion parameter for concentrations correction varying dispersion
s

Open
Gravity spreading Integration in calculations Step sizes for cl

Maximum
Gravity spreading correction Relative tolerance for dispersion calculations integration step
s

Open
Accuracy and speed
Step sizes for cloud integration Concentration grid defin
Spacing
parameter for the
Number of fixed Multiplier for Critical separation grid in the x
Fixed step size size output steps output step sizes ratio dimension
s fraction

Open
oncentration grid definition Minimum limits

Number of grid Number of grid Minimum Minimum release


points in time points in Y and Z temperature velocity for cont.
dimension direction Use grid allowed release
degC m/s

Open
Limits
um limits Maximum limits

Minimum Maximum Maximum


continuous temperature distance for Maximum height
release height allowed dispersion for dispersion
m degC m m

Open
Treatment of mixing layer

Treatment of top mixing layer

Open
Atmospheri
Constants

Atmospheric
Atmospheric Atmospheric specific heat at
Use Parameter set Name pressure molecular weight constant pressure
bar kg/kmol kJ/kg.degK
Yes Parameter set Weather parameters

Open
Atmospheric constants
Temperature and pressure data Wind speed data

Cut-off height for


Atmospheric T Temperature Wind speed Wind speed wind speed
and P profile reference height profile reference height profile
m m m

Open
Atm
General atmospheric parameters M

Mixing layer Mixing layer


Atmospheric Solar radiation height for Pasquill height for Pasquill
temperature Relative humidity flux stability A stability A/B
degC fraction kW/m2 m m

Open
Atmospheric parameters
Mixing layer height vs. Pasquill stability

Mixing layer Mixing layer Mixing layer Mixing layer Mixing layer
height for Pasquill height for Pasquill height for Pasquill height for Pasquill height for Pasquill
stability B stability B/C stability C stability C/D stability D
m m m m m

Open
ility Building data

Mixing layer Mixing layer Mixing layer


height for Pasquill height for Pasquill height for Pasquill Building exchange
stability E stability F stability G rate Tail time
m m m /hr s

Open
Substrate data
Surface temperature
Surface
temperature for Surface
dispersion temperature for
calculations pool calculations
degC degC

Open
In-bu
Ventilation

Use Parameter set Name Ventilation type Air changes Vent location
/hr
Yes Parameter set Building parameters

Open
In-building release
tilation Indoor explosion model

Internal obstacle
Indoor explosion to building area
Exhaust diameter Vent flowrate model ratio Vent panel height
m m3/hr m

Open
Indoor toxic modelling Building wake
n model Building data Chimney

Vent panel Building exchange Wind speed


location rate Tail time dependent Chimney diameter
/hr s m

Open
uilding wake
Chimney

Chimney height
m

Open
Dispersing surface
Properties

Surface over
which the Surface roughness User-defined
Use Parameter set Name dispersion occurs length length
mm
Yes Parameter set Surface parameters

Open
Surface for pools
Type of surface for pools User defined surface properties

Pool minimum Surface thermal Surface roughness


Type of surface for pools thickness diffusivity factor
mm m2/s

Open
Bund properties
e properties Bund defined Dimensions Whether the bund can ove

Surface thermal Bund area Bund failure


conductivity Specify a bund Bund height (internal) modeling
kJ/m.s.degK m m2

Open
the bund can overflow
Bund area
multiplier for
catastrophic
rupture

Open
Pool vaporisation
Cut-offs for pool evaporation
Pool
rates
vaporisation modelli

Toxics cut-off rate Flammable cut-off


for pool rate for pool Evaporation on
Use Parameter set Name evaporation evaporation land correlation
kg/s kg/s
Yes Parameter set Pool vaporisation parameters

Open
sation
aporisation modelling

Solver tolerance

Open
Toxics
Calculation options

Toxics: minimum
Multi-comp. toxic Probit calculation probability of
Use Parameter set Name calc. method method death

Yes Parameter set Toxic parameters

Open
Toxics
tions Toxic grid parameters Exposure time data

Number of grid Number of grid Set averaging time


Toxic averaging points in X points in Y equal to exposure
time Use toxics grid? direction direction time
s

Open
Toxic parameters
Exposure time data Toxic contours
Cut-off fraction of Cut-off
toxic load for concentration for
exposure time exposure time Number of toxic
calculation calculations levels Dose levels Probit levels
fraction fraction

Open
urs

Lethality levels
fraction

Open
Basis for calculations
Modelling of immediate fla

UFL multiple for


immediate
Use Parameter set Name Basis for calculations ignition

Yes Parameter set Flammable parameters

Open
Flammables
g of immediate flash fire Short duration effects

Match fireball Cut off time for


Cut off fraction for For time-varying duration and mass short continuous
cloud volume releases released releases
fraction s

Open
Flammables
Results grid steps Flammable concentrations in cloud

Flammable mass
Flammable result grid step in X- calculation Flammable LFL fraction to
direction method averaging time finish
m s fraction

Open
Wind sector modelling for flammable hazards Observer

Observer type
radiation
Number of wind subdivisions per sector modelling flag

Open
Radiation
Observer properties
Radiation probit values (units in probit equation (1 term

Observer Angle of Angle of


direction inclination orientation Probit N value Probit A value
deg deg

Open
Radiation
probit equation
Tolerances
(1 term)in
are
radiation
W.m-2) calculations
Radiation versus distance
Absolute
tolerance for Relative tolerance
linked radiation for radiation Number of radiation/distance points in linked
Probit B value calcs calculations radiation calculations
fraction

Open
Solar radiation

Solar radiation

Open
Use Parameter set Name

Yes Parameter set Explosion parameters

Open
Overpressures
Explosion overpressures
Explosion
for reporting
centre location
(gauge) criterion and minimum fl

Explosion location
Overpressure levels criterion
bar
on parameters

Open
Explosion parameters Multi-Energy
on and minimum flammable
Vapour liquid
massmethod
parameters
Multi-Energy: Uniform confined

Use explosion Explosion mass Uniform confined


Minimum mass modification modification Uniform confined method explosion
explosive mass factor factor explosion strength efficiency
kg %

Open
Multi-Energy
Multi-Energy: User-defined BST and ME
Maximum
Unconfined number of effect
Unconfined explosion Explosion points along Minimum
explosion strength efficiency efficiency method transect explosion energy
% kJ

Open
BST and ME
Calculation method Cloud view timesteps

Maximum Number of time


Between cloud number of time steps - continuous
Flammable mass calculation type views steps clouds

Open
TNT ME (3D option
esteps Cloud view control TNT parameters 3D Obstructed reg

Number of
timesteps - time Number of X steps Unconfined
varying clouds per view Minimum X step Air or ground burst explosion strength
m

Open
(3D options) BST and ME (3D op
Obstructed region Critical separation specification Cloud view me

Explosion Separation Critical separation Critical separation


efficiency specification distance ratio Method option
% m

Open
and ME (3D options)
Cloud view methods Detonation of VCE in obstructed regions

Cylinder height Concentration Elevation of floor Critical VBR for


over radius ratio method for filling or ceiling Model option detonation
m fraction

Open
BST (3D options)
T volume blockage criteria
Method
for congestion
for correcting the ground effect

Low to medium Medium to high


criterion criterion Method option Reflection factor

Open
T (3D options)
Method for combining obstructed regions

Options available

Open
Constants
Constants for radiation calculation

Use Parameter set Name Maximum surface emissive power


kW/m2
Yes Parameter set Fireball and BLEVE blast parameters

Open
Firebal
Result types to calculate Radiation levels

Number of input
Calculate probit Calculate dose Calculate lethality radiation levels Intensity levels
kW/m2

Open
Fireball
Radiation levels Parameters

Mass modification Fireball maximum


Probit levels Dose levels Lethality levels factor exposure duration
fraction s

Open
BLEVE blast parameters
Calculation method BLEVE blast parameters

TNO model flame Air or ground Ideal gas


Fireball model temperature burst modeling Model option
degC

Open
t parameters
t parameters

Minimum Number of
distance distance points
m

Open
Jet fire reference
Constant for jet fire calculation

Use Parameter set Name Jet fire averaging time


s
Yes Parameter set Jet fire parameters

Open
re reference data
Constants for radiation calculation Result types to calculate

Maximum SEP for a jet fire Calculate probit Calculate dose


kW/m2

Open
Je
es to calculate Radiation levels

Number of input
Calculate lethality radiation levels Intensity levels Probit levels Dose levels
kW/m2

Open
Jet fire
Parameters Cone model data

Rate modification Jet fire maximum


Lethality levels factor exposure duration Crosswind angle Horizontal options
fraction s deg

Open
one model data Surface emissive power
Calculation
Flame-shape method for
adjustment if surface emissive Flame emissive
Correlation grounded power power Emissivity fraction
kW/m2 fraction

Open
Pool fire reference data
Minimum pool duration for pool fire risk
Result types to cal

Instantaneous Continuous
Use Parameter set Name releases releases Calculate probit
s s
Yes Parameter set Pool fire parameters

Open
Pool fire
Result types to calculate Radiation levels

Number of input
Calculate dose Calculate lethality radiation levels Intensity levels Probit levels
kW/m2

Open
e
tion levels Parameters

Pool fire
Radiative fraction maximum
Dose levels Lethality levels for general fires exposure duration
fraction fraction s

Open
General reference
Discharge and dispersion

Use Parameter set Name Maximum release duration


s
Yes Parameter set General parameters

Open
General reference data
Reporting of concentrations and effects

Height of interest
m

Open
Effect
Grid

Grid calculation Maximum


Use Parameter set Name method Grid cell size number of cells
m
Yes Parameter set Grid parameters

Open
Effects grid
Grid bounds

Grid bounds Grid bounds Grid bounds Grid bounds


Grid sizing minimum x maximum x minimum y maximum y
m m m m

Open
Physical
Use Properties System Materials Material Folder Name

Yes Physical Properties Materials METHANOL

Open
Component

Property Method Template

PhastMC

Open
Componen
Selected Compo
Physical
Use Properties System Materials Material Folder Name Component
Skip if already exists
Yes Physical Properties Materials 010-04 METHANE
ETHANE
PROPYLENE
N-BUTANE
HYDROGEN
METHANOL
Yes Physical Properties Materials 010-05 METHANE
ETHANE
PROPYLENE
N-BUTANE
HYDROGEN
METHANOL
Yes Physical Properties Materials P2-010-05 METHANE
ETHANE
PROPYLENE
N-BUTANE
HYDROGEN
METHANOL
Yes Physical Properties Materials P2-010-07 METHANE
ETHANE
PROPYLENE
N-BUTANE
HYDROGEN
METHANOL
Yes Physical Properties Materials P2-020-01 METHANE
ETHANE
PROPYLENE
N-BUTANE
HYDROGEN
METHANOL
Yes Physical Properties Materials P2-020-03 METHANE
ETHANE
PROPYLENE
N-BUTANE
HYDROGEN
METHANOL
Yes Physical Properties Materials P2-020-06 METHANE
ETHANE
PROPYLENE

Open
N-BUTANE
HYDROGEN
METHANOL
Yes Physical Properties Materials P2-020-02 METHANE
ETHANE
PROPYLENE
N-BUTANE
HYDROGEN
METHANOL
Yes Physical Properties Materials P2-020-02 METHANE
ETHANE
PROPYLENE
N-BUTANE
HYDROGEN
METHANOL
Yes Physical Properties Materials P2-020-07 METHANE
ETHANE
PROPYLENE
N-BUTANE
HYDROGEN
METHANOL
Yes Physical Properties Materials P2-025-01 METHANE
ETHANE
PROPYLENE
N-BUTANE
HYDROGEN
METHANOL
Yes Physical Properties Materials P2-025-02 METHANE
ETHANE
PROPYLENE
N-BUTANE
HYDROGEN
METHANOL
Yes Physical Properties Materials P2-030-03 METHANE
ETHANE
PROPYLENE
N-BUTANE
HYDROGEN
METHANOL
Yes Physical Properties Materials P2-030-04 METHANE
ETHANE
PROPYLENE
N-BUTANE
HYDROGEN
METHANOL
Yes Physical Properties Materials P2-030-07 METHANE
ETHANE

Open
PROPYLENE
N-BUTANE
HYDROGEN
METHANOL
Yes Physical Properties Materials P2-030-06 METHANE
ETHANE
PROPYLENE
N-BUTANE
HYDROGEN
METHANOL
Yes Physical Properties Materials P2-030-12 METHANE
ETHANE
PROPYLENE
N-BUTANE
HYDROGEN
METHANOL
Yes Physical Properties Materials P2-030-08 METHANE
ETHANE
PROPYLENE
N-BUTANE
HYDROGEN
METHANOL
Yes Physical Properties Materials NG METHANE
ETHANE
PROPYLENE
N-BUTANE
HYDROGEN
METHANOL
Yes Physical Properties Materials MeOH METHANE
ETHANE
PROPYLENE
N-BUTANE
HYDROGEN
METHANOL
Yes Physical Properties Materials P1-101 METHANE
ETHANE
PROPYLENE
N-BUTANE
HYDROGEN
METHANOL
Yes Physical Properties Materials P1-105 METHANE
ETHANE
PROPYLENE
N-BUTANE
HYDROGEN
METHANOL
Yes Physical Properties Materials P1-113 METHANE

Open
ETHANE
PROPYLENE
N-BUTANE
HYDROGEN
METHANOL
Yes Physical Properties Materials P1-201 METHANE
ETHANE
PROPYLENE
N-BUTANE
HYDROGEN
METHANOL
Yes Physical Properties Materials P1-203 METHANE
ETHANE
PROPYLENE
N-BUTANE
HYDROGEN
METHANOL
Yes Physical Properties Materials P1-113 METHANE
ETHANE
PROPYLENE
N-BUTANE
HYDROGEN
METHANOL
Yes Physical Properties Materials P1-301 METHANE
ETHANE
PROPYLENE
N-BUTANE
HYDROGEN
METHANOL
Yes Physical Properties Materials P1-304 METHANE
ETHANE
PROPYLENE
N-BUTANE
HYDROGEN
METHANOL
Yes Physical Properties Materials P1-306 METHANE
ETHANE
PROPYLENE
N-BUTANE
HYDROGEN
METHANOL
Yes Physical Properties Materials P1-309 METHANE
ETHANE
PROPYLENE
N-BUTANE
HYDROGEN
METHANOL

Open
Yes Physical Properties Materials MEOH METHANE
ETHANE
PROPYLENE
N-BUTANE
HYDROGEN
METHANOL

Open
Components Properties
Selected Components

Mass Mole Property Method Template

85.141 PhastMC
5.258
3.419
1.274
2.995
0
85.141 PhastMC
5.258
3.419
1.274
2.995
1.5604421669
85.141 PhastMC
5.258
3.419
1.274
2.995
0
85.141 PhastMC
5.258
3.419
1.274
2.995
0
85.141 PhastMC
5.258
3.419
1.274
2.995
0
85.141 PhastMC
5.258
3.419
1.274
2.995
0
85.141 PhastMC
5.258
3.419

Open
1.274
2.995
0
85.141 PhastMC
5.258
3.419
1.274
2.995
0
85.141 PhastMC
5.258
3.419
1.274
2.995
0
85.141 PhastMC
5.258
3.419
1.274
2.995
0
85.141 PhastMC
5.258
3.419
1.274
2.995
0
85.141 PhastMC
5.258
3.419
1.274
2.995
0
85.141 PhastMC
5.258
3.419
1.274
2.995
0
85.141 PhastMC
5.258
3.419
1.274
2.995
0
85.141 PhastMC
5.258

Open
3.419
1.274
2.995
0
85.141 PhastMC
5.258
3.419
1.274
2.995
0
85.141 PhastMC
5.258
3.419
1.274
2.995
0
85.141 PhastMC
5.258
3.419
1.274
2.995
0
85.141 PhastMC
5.258
3.419
1.274
2.995
0
85.141 PhastMC
5.258
3.419
1.274
2.995
0
85.141 PhastMC
5.258
3.419
1.274
2.995
0
85.141 PhastMC
5.258
3.419
1.274
2.995
0
85.141 PhastMC

Open
5.258
3.419
1.274
2.995
0
85.141 PhastMC
5.258
3.419
1.274
2.995
0
85.141 PhastMC
5.258
3.419
1.274
2.995
0
85.141 PhastMC
5.258
3.419
1.274
2.995
0
85.141 PhastMC
5.258
3.419
1.274
2.995
0
85.141 PhastMC
5.258
3.419
1.274
2.995
0
85.141 PhastMC
5.258
3.419
1.274
2.995
0
85.141 PhastMC
5.258
3.419
1.274
2.995
0

Open
85.141 PhastMC
5.258
3.419
1.274
2.995
0

Open
Physical
Use Properties System Materials Material Folder Name Carbon

Open
Comp
Numbe

Hydrogen Oxygen Nitrogen Sulphur Chlorine

Open
Composition
Number of atoms

Phosphorus Manganese Zinc Tin Bromine

Open
Specify total Total molecular
Iodine Fluorine molecular weight weight
kg/kmol

Open
External Connection
Connection

Use Name Connection Type Location Connection Info Description

Open
Source
Table General

External
Use connection Name Table Name Geometry Field Colour

Open
General Point Line

Translucency Size Symbol Width Style


%

Open
Style
Area

Pattern Colour Boundary File Symbol

Open
Style
Symbol

Size Rotation Colours Spacing X Spacing Y


deg

Open
Text Invisible

Stagger Font Size Colour Ignored Class

Open
isible

Style name

Open
Raster Image
Image

Use Raster Image Set Folder Name Placement Mode Path

Open
r Image Geometry
mage Geometry

Coordinate Rotation (anti-


System File East North clockwise) Width
m m deg m

Open
metry
Invisible

Length Shape Dimension


m

Open
Bund properties
Bund defined Dimensions

Types of pool
substrate and
Use bunds Name Specify a bund Bund height
m
Yes Types of pool substConcrete, no bund

Open
Bund properties Surface fo
Dimensions Whether the bund can overflow
Type of surface for pools
Bund area
multiplier for
Bund area Bund failure catastrophic
(internal) modeling rupture Type of surface for pools
m2

Open
Surface for pools
User defined surface properties

Pool minimum Surface thermal Surface roughness Surface thermal


thickness diffusivity factor conductivity
mm m2/s kJ/m.s.degK

Open
Dispersing surface
Properties

Surface over
Types of terrain which the Surface roughness User-defined
Use for dispersion Name dispersion occurs length length
mm
Yes Types of terrain for Land

Open
In-bu
Ventilation

Use Buildings Name Ventilation type Air changes Vent location


/hr
Yes Buildings Building type

Open
In-building release
tilation Indoor explosion model

Internal obstacle
Indoor explosion to building area
Exhaust diameter Vent flowrate model ratio Vent panel height
m m3/hr m

Open
Indoor toxic modelling
n model Building data

Vent panel Building exchange Wind speed


location rate Tail time dependent
/hr s

Open
Obstruction data
Multi-Energy curve

Multi-Energy Defined strength


Use obstruction set obstruction group Name Curve number

Open
bstruction data Ge
Volume of obstruction Geometry

Rotation (anti-
Blockage ratio East North clockwise)
m m deg

Open
Geometry
Geometry Invisible

Width Length Lower elevation Upper elevation Shape


m m m m

Open
Invisible

Dimension

Open
O
Degree of expansion

Calculated
Multi-Energy strength
Use obstruction set obstruction group Name Degree of expansion

Open
Obstruction data
Volume Obstruction Flame path length

Flame path length


Blockage ratio Obstruction type Surface area sum Typical diameter type
m2 m

Open
Geometry
ame path length Geometry

Rotation (anti-
Flame length path East North clockwise) Width
m m m deg m

Open
Geometry
ometry Invisible

Length Lower elevation Upper elevation Shape Dimension


m m m

Open
Obstruction data
BST flame speed

BST obstruction Defined flame


Use set speed group Name Mach number

Open
Obstruction data G
Volume of obstructions Geometry

Rotation (anti-
Blockage ratio East North clockwise)
m m deg

Open
Geometry
Geometry Invisible

Width Length Lower elevation Upper elevation Shape


m m m m

Open
Invisible

Dimension

Open
Degree of confinement

BST obstruction Calculated flame


Use set speed group Name Degree of confinement

Open
Obstruction data
Obstructed volume Congestion

Ratio in X
Blockage ratio Congestion Congestion level direction

Open
a
gestion Reactivity

Ratio in Y Ratio in Z Fuel reactivity


direction direction type Reactivity level East
m

Open
Geometry
Geometry

Rotation (anti-
North clockwise) Width Length Lower elevation
m deg m m m

Open
Invisible

Upper elevation Shape Dimension


m

Open
G

Use Buildings Building type Name East North


m m

Open
Geometry
Geometry

Rotation (anti-
clockwise) Width Length Lower elevation Upper elevation
deg m m m m

Open
Building wake
Chimney

Chimney diameter Chimney height


m m

Open
Overpressure
Overpressure

Overpressure
Use Effect levels Name Pressure method level
bar

Open
Impulse
Impulse

Use Effect levels Name Pressure method Impulse level


N.s/m2

Open
Radiation
Radiation

Radiation
Use Effect levels Name intensity level Exposure time
s

Open
Radiation
Radiation

Radiation
Use Effect levels Name intensity level Exposure time
s

Open
Radiation
Radiation

Radiation intensity
Use Effect levels Name level

Open
Use Effect levels Name

Open
Use Effect levels Name

Open
Use Effect levels Name

Open

You might also like