You are on page 1of 5

PROJECT NO.

PO. 4500098732 / 10 / 01.01.2018


PROJECT TITLE

Supply of PF Process Calculation Spreadsheet (Excel


Forma)
E T
H
DOCUMENT TITLE
E
E S
L
Control Valve Sizing for Single Phase - Gas Flow

M P
SA

DATE REV. REASON FOR REVISION PREP. CHKD. APPD. APPD.

DOC. NO. CEPL-PC-001-CA-001A PAGE 1 of 5 REV. 0


Control Valve Sizing for Single Phase - Gas Flow
DOC. NO. CEPL-PC-001-CA-001A REV. 0
PROJECT NO. PO. 4500098732 / 10 / 01.01.2018 PAGE NO. 2 of 5
PROJECT TITLE Supply of PF Process Calculation Spreadsheet (Excel Forma)
BASIS

Calculation Objective

Calculation Basis

E T
Calculation Methodology

H E
E S
PL
M
SA
Assumptions

Software used

Conclusions

References

Attachments
Control Valve Sizing for Single Phase - Gas Flow
DOC. NO. CEPL-PC-001-CA-001A REV. 0
PROJECT NO. PO. 4500098732 / 10 / 01.01.2018 PAGE NO. 3 of 5
PROJECT TITLE Supply of PF Process Calculation Spreadsheet (Excel Forma)
SCHEMATIC:

This spreadsheet provides the sizing calculations of control valve for compressible fluid.

INPUT
Case 1 Case 2 Case 3
800.00 600.00 400.00 kg/h W Gas mass flowrate
7.00 7.00 7.00 barg P1 Inlet pressure
2
7.14 7.14 7.14 kg/cm g P1 Inlet pressure
0.30 0.50 1.00 bar ∆P Pressure drop

T
0.31 0.51 1.02 kg/cm2 ∆P Pressure drop

E
o
25.00 25.00 25.00 C T1 Inlet temperature

E
1.00 1.00 1.00 Z Compressibility factor at inlet conditions

H
29.0 29.00 29.00 g/gmol MW Molecula weight

S
1.4 1.40 1.40 y Specific heat ratio factor
15.00 15.0 15.0 cSt v Kinematic viscosity

E
2.0 2.00 2.00 inch d control valve NB

L
2.0 2.00 2.00 inch D1 Inlet Pipe ID

P
2.0 2.00 2.00 inch D2 Outlet pipe ID

M
FL Liquid pressure recovery factor of a control valve
0.80 0.8 0.8
without attached fittings

SA
0.80 0.80 0.80 Fd Valve style modifier

xT Pressure differential ratio factor of a control valve


0.80 0.80 0.80
without attached fittings at choked flow

80.00 67.00 52.50 % Valve output for maximum flow


Equal Percentage Equal Percentage Equal Percentage Valve characteristics

RESULTS
The results are within The results are within The results are within
applicable scope of ANSI- applicable scope of ANSI- applicable scope of ANSI-
ISA 75-01-01. ISA 75-01-01. ISA 75-01-01.
9.37 9.37 9.37 kg/m3 ρ Density at inlet conditions
XTP Pressure differential ratio factor of a control valve
0.8 0.8 0.8
with attached fittings at choked flow

1.00 1.00 1.00 FP Piping geometry factor


x Ratio of actual pressure differential to inlet
0.037 0.062 0.125
absolute pressure

0.984 0.974 0.948 y Expansion factor


17.8 10.4 5.1 Cv Flow coefficient 0
35 35 35 Cv_D Design flow coefficient
Remarks
Control Valve Sizing for Single Phase - Gas Flow
DOC. NO. CEPL-PC-001-CA-001A REV. 0
PROJECT NO. PO. 4500098732 / 10 / 01.01.2018 PAGE NO. 4 of 5
PROJECT TITLE Supply of PF Process Calculation Spreadsheet (Excel Forma)

To calculate Reynolds number:

E T
H E
E S
PL
M
SA
Control Valve Sizing for Single Phase - Gas Flow
DOC. NO. CEPL-PC-001-CA-001A REV. 0
PROJECT NO. PO. 4500098732 / 10 / 01.01.2018 PAGE NO. 5 of 5
PROJECT TITLE Supply of PF Process Calculation Spreadsheet (Excel Forma)

E T
H E
E S
PL
M
SA