Frame sizes 112M to 180L with a terminal box mounted at the non-drive end,
optionally on the righthand side
Page 1 /18
SIEMENS
Inverter-fed three-phase roller table motors
Contents
Contents ....................................................................................................................... …….Page
1 1LP 3 range of motors ..................................................................................…………………2
2 Technical information ............................................................................................................. 3
2.1 General................................................................................................................................... 3
2.2 Standards and regulations...................................................................................................... 3
2.3 Electrical data ......................................................................................................................... 3
2.4 Mechanical version ................................................................................................................ 4
3 Additional documentation ...............................................................................................……5
Attachments:
Attachment 1: Rated operating data: 400 V when fed from SIMOVERT MASTERDRIVES drive inverters
Attachment 2: Rated operating points: 400 V when fed from drive inverters, from 20 to 50 Hz.
Attachment 3: Rated operating data: Special 690 V insulation when fed from SIMOVERT MASTERDRIVES
drive inverters
Attachment 4: Rated operating points: Special 690 V insulation when fed from drive inverters, 20 to 50 Hz.
Attachment 5: Rated operating data, 400 V when fed directly form the line supply
Attachment 6: Special versions
Attachment 7: Terminal boxes for 1LP3 motors
Attachment 8: Dimension table: 1LP3 118 to 188
Attachment 9: Dimension table: 1LP3 206 to 406, standard version
Attachment 10: Dimension table: 1LP3 206 to 406, special version with tapered shaft end acc. to DIN 1448
Attachment 11: Torque – frequency characteristic, 4-pole
Attachment 12: Torque – frequency characteristic, 6-pole
Attachment 13: Torque – frequency characteristic, 8-pole
Page 2 /18
SIEMENS
Inverter-fed three-phase roller table motors
2 Technical information
2.1 General
Today, a high proportion of directly driven rollers are used for working and transport roller tables in reversing
rolling mills.
The ongoing development of static frequency inverters and the associated control techniques now mean that
rugged induction motors can generally be used for all roller table drives.
This series of motors was developed for inverter operation. The mechanical design has been specifically
adapted to the high requirements that occur, especially for roller table applications.
Rating plate:
Examples
Insulation
“DURIGNIT® IR 2000” insulating system
Temperature rise F utilized to temperature rise F is standard.
Optional, temperature rise H for motors with standard insulation.
Page 3 /18
SIEMENS
Inverter-fed three-phase roller table motors
Paint finish
A special paint finish is standard, color RAL 7030.
Type of construction
The motors have type of construction IM B3 and have cast-on mounting feet.
The motor shaft has half-key balancing. The shaft end is, as standard, manufactured out of stainless steel,
frame sizes 112M to 180L und 280M to 400. (optionally for frame sizes 200L to 250M).
The shaft end is cylindrical acc. to DIN 748 with centering bore and key.
Special versions are available from frame size 200L and above with tapered shaft end in compliance with DIN
1448.
Terminal box
Terminal box arrangement
• For frame sizes 112M to 180L, at the non-drive end bearing endshield, optionally, on the righthand side
(Code K09). The cable entries are sealed with plugs; refer to Attachment 7. Two metric glands are
optionally available.
• From frame size 200L and above on the non-drive end on the top of the frame. Plates are bolted-on for
the cable glands. Drilled plates with two metric glands are optionally available.
Mounted equipment
A rotary pulse encoder can be mounted as option. The terminal box is additionally required on the righthand
side for frame sizes 112M to 180L (code K09). When encoders are mounted, it is not possible to mount the
terminal box at the non-drive end!
From frame size 200L onwards, in the standard version, the non-drive shaft end can be accessed to measure
the speed.
Cooling
The motors are non-ventilated and do not have their own fan.
Protection
The motors have, in the basic versions, and frame sizes
- 112M and 180L, degree of protection IP65 - optionally IP56 "non-heavy-sea"
- 200L to 400, degree of protection IP55, optionally IP56 "non-heavy-sea" or IP65
Page 4 /18
SIEMENS
Inverter-fed three-phase roller table motors
Ambient temperature:
In the standard version, motors can be used in frame sizes
- 112M to 180L from -30 to +40 °C
- 200L to 400 from -20 to +40 °C
Bearings
The motors have roller bearings with permanent lubrication. From frame size 280M and above post lubrication
with grease quantity control. The bearings have a nominal lifetime of at least 40,000 operating hours for a
coupling output. The grease lifetime for the permanently lubricated bearings is 20,000 operating hours at a
cooling medium temperature of 40 °C.
Measuring nipples for SPM shock pulse measurement are optionally possible to check the bearings.
In order to prevent bearing currents, motors frame sizes 315L to 400 are equipped with bearing insulation as
standard. This is optional for frame sizes 225M to 280M.
For motors, frame sizes 225M to 315L, special insulated bearings are used. For motors, frame sizes 355 and
400, standard bearings are used – whereby the bearing endshields are insulated.
3 Additional documentation
1LP3 operating instructions:
http://support.automation.siemens.com/WW/view/en/11599057/133300
Page 5 /18
SIEMENS
Inverter-fed three-phase roller table motors
Rated operating data: 400 V when fed from SIMOVERT MASTERDRIVES drive inverters Attachment 1
Order No. Frame Fre- Rated Speed Efficiency Power Rated Peak Rated Surge Moment Weight
size quency power factor torque 1) transient current 2) current of inertia
2)
torque at at J
400 V 400 V
Hz kW RPM % Nm Nm A A kg/m2 kg
1LP3 118-4RL.. 112M 50 2.7 1460 83 0.74 18 54 6.5 20 0.014 55
1LP3 133-4RL.. 132M 50 4 1470 85 0.72 26 78 10 30 0.024 70
1LP3 138-4RL.. 132M 50 5.5 1470 86 0.73 36 108 14 42 0.031 80
1LP3 166-4RL.. 160L 50 7.5 1480 88 0.74 48 144 17 51 0.052 155
1LP3 168-4RL.. 160L 50 9.3 1480 89 0.74 60 180 21 63 0.07 170
1LP3 186-4RL.. 180L 50 11 1480 91 0.76 71 213 23 69 0.15 180
1LP3 188-4RL.. 180L 50 14 1480 91 0.76 90 270 29 87 0.19 195
1LP3 186-6RL.. 180L 50 8.5 980 88 0.71 83 249 20 60 0.15 190
1LP3 188-6RL.. 180L 50 11 980 89 0.71 107 321 25 75 0.19 205
1LP3 206-6RL.. 200L 20 7 390 83.2 0.54 170 680 22.5 63 0.6 300
1LP3 226-6RL.. 225M 20 10.5 390 86.1 0.59 255 1020 29 90 1.0 400
1LP3 256-6RL.. 250M 20 16.5 390 88.7 0.65 405 1620 41.5 142 1.8 600
1LP3 286-6RL.. 280M 20 26 390 89.9 0.70 640 2560 60 215 3.0 800
1LP3 316-6RL.. 315M 20 35 393 91.3 0.70 850 3400 79 280 5.2 1100
1LP3 316-8RL.. 315M 20 29 291 88.7 0.60 950 3800 79 245 5.2 1100
1LP3 356-8RL.. 355 20 44.5 294 90.4 0.60 1445 5780 118 370 9.5 1600
1LP3 406-8RL.. 400 20 66 295 91.9 0.60 2135 8540 172 540 19 2100
1) The specified rated torques are in compliance with EN 60034, duty type S1. For duty type S9 and when determining the thermal load, it must be noted that the current is not
proportional to the load torque, and in no-load and weak load phases, a stator current flows to magnetize the motors.
2) The following approximately applies: I~M in the range between the rated torque and the peak transient torque.
Page 6 /18
SIEMENS
Inverter-fed three-phase roller table motors
Rated operating points: 400 V when fed from drive inverters, from 20 to 50 Hz Attachment 2
Rated operating points at 400 V
20 Hz 30 Hz 40 Hz 50 Hz
Motor type Frame S1 S1 Surge S1 Peak S1 Surge S1 Peak S1 Surge S1 Peak S1 Surge
size rated Peak rated current rated transient rated current rated transient rated current rated transient rated current
torque transient current at 400 torque torque current at 400 torque torque current at 400 torque torque current at 400 V
torque at 400 V at 400 V at 400 V at 400
Nm V V Nm V Nm V A
Nm A A Nm Nm A A Nm A A Nm A
Page 7 /18
SIEMENS
Inverter-fed three-phase roller table motors
Attachment 3
Rated operating data: Special 690 V insulation when fed from SIMOVERT MASTERDRIVES drive inverters
Order No. Frame Fre- Rated Speed Efficiency Power Rated- Peak Rated Surge Moment of Weight
size quency power factor torque 1) transient current 2) current 2) inertia
torque at at
690 V 690 V
Hz kW RPM % Nm kg/m2 kg
Nm A A
1LP3 118-4RM.. 112M 50 2.5 1460 83 0.74 16 48 3.5 11 0.014 55
1LP3 133-4RM.. 132M 50 3.8 1470 85 0.72 24.5 74 5.5 16 0.024 70
1LP3 138-4RM.. 132M 50 5.2 1470 86 0.73 34 102 7.5 22 0.031 80
1LP3 166-4RM.. 160L 50 7.1 1480 88 0.74 45 135 9.5 28 0.052 155
1LP3 168-4RM.. 160L 50 8.8 1480 89 0.74 57 171 12 36 0.07 170
1LP3 186-4RM.. 180L 50 10.5 1480 91 0.76 68 204 13 39 0.15 180
1LP3 188-4RM.. 180L 50 13.5 1480 91 0.76 87 261 17 51 0.19 195
1LP3 186-6RM.. 180L 50 8 980 88 0.71 78 234 12 36 0.15 190
1LP3 188-6RM.. 180L 50 10.5 980 89 0.71 102 306 14 42 0.19 205
1LP3 206-6RM.. 200L 20 6.3 390 83.0 0.52 155 640 12.2 34 0.6 300
1LP3 226-6RM.. 225M 20 9.6 390 86.0 0.58 235 940 16.2 48 1.0 400
1LP3 256-6RM.. 250M 20 15.5 390 88.5 0.64 380 1550 23 78 1.8 600
1LP3 286-6RM.. 280M 20 24.5 390 89.5 0.68 600 2470 33.5 120 3.0 800
1LP3 316-6RM.. 315M 20 32.5 393 91.0 0.69 790 3290 43.5 156 5.2 1100
1LP3 316-8RM.. 315M 20 26.5 291 88.3 0.58 870 3490 44 130 5.2 1100
1LP3 356-8RM.. 355 20 41 294 90.0 0.58 1330 5540 66 205 9.5 1600
1LP3 406-8RM.. 400 20 63 295 91.7 0.59 2040 8420 97 305 19 2100
1) The specified rated torques are in compliance with EN 60034, duty type S1. For duty type S9 and when determining the thermal load, it must be noted that the current is not proportional to the
load torque, and in no-load and weak load phases, a stator current flows to magnetize the motors.
2) The following approximately applies: I~M in the range between the rated torque and peak transient torque
Page 8 /18
SIEMENS
Inverter-fed three-phase roller table motors
Rated operating points: Special 690 V insulation for drive inverter operation from 20 to 50 Hz Attachment 4
20 Hz 30 Hz 40 Hz 50 Hz
Motor type Frame S1 S1 Surge S1 Peak S1 Surge S1 Peak S1 Surge S1 Peak S1 Surge
size Rated Peak Rated current Rated transient Rated- current Rated transient Rated- current Rated transient Rated- current
Torque transient current at torque torque current at torque torque current at torque torque current at
torque at 690 V 690 V at 690 V 690 V at 690 690 V at 690 V 690 V
V
Nm Nm A A Nm Nm A A Nm Nm A A Nm Nm A A
Page 9 /18
SIEMENS
Inverter-fed three-phase roller table motors
Rated operating data, 400 V when fed directly from the line supply Attachment 5
Order No. Frame Fre- Rated Speed Efficiency Power Rated Peak Rated current Surge Moment of Weight
size quency power2) 2)
factor torque 1) transient 2)
current 2) inertia
torque at at
400 V 400 V
Hz kW RPM % Nm A A kg/m2 kg
Nm
1LP3 118-4RL.. 112M 50 3 1450 84 0.78 20 60 6.5 20 0.014 55
1LP3 133-4RL.. 132M 50 4.5 1470 86 0.77 29 87 10 30 0.024 70
1LP3 138-4RL.. 132M 50 6 1470 87 0.77 39 117 14 42 0.031 80
1LP3 166-4RL.. 160L 50 8 1480 89 0.77 52 156 17 51 0.052 155
1LP3 168-4RL.. 160L 50 10 1480 90 0.77 65 195 21 63 0.07 170
1LP3 186-4RL.. 180L 50 12 1480 92 0.78 77 231 24 72 0.15 180
1LP3 188-4RL.. 180L 50 15 1480 92 0.78 97 291 30 90 0.19 195
1LP3 186-6RL.. 180L 50 9 980 89 0.72 88 264 21 63 0.15 190
1LP3 188-6RL.. 180L 50 11.5 980 90 0.73 112 336 25 75 0.19 205
1) The specified rated torques are in compliance with EN 60034, duty type S1. For duty type S9 and when determining the thermal load, it must be noted that the current is not proportional to the load torque, and in no-
load and weak load phases, a stator current flows to magnetize the motors.
2) The following approximately applies: I~M in the range between the rated torque and peak transient torque.
Page 10 /18
SIEMENS
Inverter-fed three-phase roller table motors
Page 11 /18
SIEMENS
Inverter-fed three-phase roller table motors
1LP3 Frame size Metric cable gland Sealing range No. of Contact stud Maximum cable
mm terminals thread cross-section that
can be connected
118 112M 1 x M32x1.5 11 - 21 6 M4 6 mm²
1 x M25x1.5 9 - 17
133, 138 132M 1 x M40x1.5 19 - 28 6 M5 10 mm²
1 x M25x1.5 9 - 17
166, 168 160L 1 x M40x1.5 19 - 28 6 M5 10 mm²
1 x M25x1.5 9 - 17
186, 188 180M 2 x M40x1.5 19 - 28 6 M5 16 mm²
2 x M20x1.5 9 - 13
206 200L 2 x M40x1.5 19 - 28 6 M6 16 mm²
2 x M20x1.5 9 - 13
226 225M 2 x M40x1.5 19 - 28 6 M6 16 mm²
2 x M20x1.5 9 - 13
256 250M 2 x M40x1.5 19 - 28 6 M6 16 mm²
2 x M20x1.5 9 - 13
286 280M 2 x M50x1.5 24 - 35 6 M8 50 mm²
2 x M20x1.5 9 - 13
316 315L 2 x M50x1.5 24 - 35 6 M8 50 mm²
2 x M20x1.5 9 - 13
356 355 2 x M50x1.5 24 - 35 6 M8 50 mm²
2 x M20x1.5 9 - 13
406 400 2 x M63x1.5 32 - 42 (40 - 48)*) 6 M10 120 mm²
2 x M20x1.5 9 - 13
*) When the customer requests it, sealing range 40 - 48 mm
1LP3 118 to 188 has cable glands with metric holes according to the table that are sealed using the appropriate plugs.
2 metric glands can be optionally supplied.
1LP3 206 to 406: The plates bolted to terminal box are undrilled. Optionally drilled, whereby 2 metric glands are supplied.
For motors, frame sizes
- 200 and 225, a plate is bolted to the non-drive end.
- 250 to 400 a plate is bolted to the non-drive end and to the righthand and lefthand side ... the 3 plates are compatible with one another.
Page 12 /18
SIEMENS
Inverter-fed three-phase roller table motors
Page 13 /18
SIEMENS
Inverter-fed three-phase roller table motors
1LP3 A AB B C HD LC H E D F GA K
206 318 390 355 133 505 740 200 110 55 16 59 19
256 406 490 450 168 595 915 250 140 70 20 74,5 24
286 457 550 500 190 680 1045 280 140 75 20 79,5 24
356 610 700 630 254 810 1335 355 210 100 28 106 28
406 686 790 630 280 955 1385 400 210 110 28 116 35
Cable entry on the righthand side, on the lefthand side and from the non-drive end.
From frame size 250M, the 3 plates are compatible with one another
Page 14 /18
SIEMENS
Inverter-fed three-phase roller table motors
Dimension table: 1LP3 206 to 406, special version with tapered shaft end acc. to DIN 1448 Attachment 10
1LP3 A AB B C HD LC H K d l l1 d2
206 318 390 355 133 505 770 200 19 60 140 105 M42x3
226 356 440 400 149 550 820 225 19 65 140 105 M42x3
256 406 490 450 168 595 915 250 24 75 140 105 M48x3
286 457 550 500 190 680 1075 280 24 80 170 130 M56x4
316 508 620 560 216 740 1155 315 28 90 170 130 M64x4
356 610 700 630 254 810 1335 355 28 110 210 165 M80x4
406 686 790 630 280 955 1385 400 35 120 210 165 M90x4
Cable entry on the righthand side, on the lefthand side and from the non-drive end.
From frame size 250M, the 3 plates are compatible with one another.
Page 15 /18
SIEMENS
Inverter-fed three-phase roller table motors
120
f > 50 Hz:
Rough nominal values
100 for engineering
80 1LP3118-4RL
1LP3133-4RL
Mn [Nm]
1LP3138-4RL
60 1LP3166-4RL
1LP3168-4RL
1LP3186-4RL
40
1LP3188-4RL
20
0
0 10 20 30 40 50 60 70 80 90 100
f [ Hz]
Page 16 /18
SIEMENS
Inverter-fed three-phase roller table motors
900
f > 50 Hz:
800
Rough nominal values
700 for engineering
600 1LP3186-6RL
1LP3188-6RL
Mn [Nm]
500 1LP3206-6RL
1LP3226-6RL
400 1LP3256-6RL
1LP3286-6RL
300
1LP3316-6RL
200
100
0
0 10 20 30 40 50 60 70 80 90 100
f [ Hz]
Page 17 /18
SIEMENS
Inverter-fed three-phase roller table motors
2500
f > 50 Hz:
Rough nominal values
for engineering
2000
1500
1LP3316-8RL
Mn [Nm]
1LP3356-8RL
1LP3406-8RL
1000
500
0
0 10 20 30 40 50 60 70 80 90 100
f / [Hz]