You are on page 1of 18

SIEMENS

Inverter-fed three-phase roller table motors

1LP3 three-phase roller table motors, frame sizes 112M to


400 fed from SIMOVERT MASTERDRIVES
drive inverters
Technical List
Edition: August 2005 (No longer valid: April 2002 Edition)

Frame sizes 112M to 180L with a terminal box mounted at the non-drive end,
optionally on the righthand side

Frame sizes 200L to 400 with top-mounted terminal box

Page 1 /18
SIEMENS
Inverter-fed three-phase roller table motors

Contents
Contents ....................................................................................................................... …….Page
1 1LP 3 range of motors ..................................................................................…………………2
2 Technical information ............................................................................................................. 3
2.1 General................................................................................................................................... 3
2.2 Standards and regulations...................................................................................................... 3
2.3 Electrical data ......................................................................................................................... 3
2.4 Mechanical version ................................................................................................................ 4
3 Additional documentation ...............................................................................................……5

Attachments:
Attachment 1: Rated operating data: 400 V when fed from SIMOVERT MASTERDRIVES drive inverters
Attachment 2: Rated operating points: 400 V when fed from drive inverters, from 20 to 50 Hz.
Attachment 3: Rated operating data: Special 690 V insulation when fed from SIMOVERT MASTERDRIVES
drive inverters
Attachment 4: Rated operating points: Special 690 V insulation when fed from drive inverters, 20 to 50 Hz.
Attachment 5: Rated operating data, 400 V when fed directly form the line supply
Attachment 6: Special versions
Attachment 7: Terminal boxes for 1LP3 motors
Attachment 8: Dimension table: 1LP3 118 to 188
Attachment 9: Dimension table: 1LP3 206 to 406, standard version
Attachment 10: Dimension table: 1LP3 206 to 406, special version with tapered shaft end acc. to DIN 1448
Attachment 11: Torque – frequency characteristic, 4-pole
Attachment 12: Torque – frequency characteristic, 6-pole
Attachment 13: Torque – frequency characteristic, 8-pole

1 1LP3 range of motors


Basic version:
- Frame size 112M to 180L: 4-pole
- Frame size 180L to 315L: 6-pole
- Frame size 315L to 400: 8-pole
Voltages < 500 V: Normal insulation
Voltages > 500 V: Special insulation

Page 2 /18
SIEMENS
Inverter-fed three-phase roller table motors

2 Technical information
2.1 General
Today, a high proportion of directly driven rollers are used for working and transport roller tables in reversing
rolling mills.
The ongoing development of static frequency inverters and the associated control techniques now mean that
rugged induction motors can generally be used for all roller table drives.
This series of motors was developed for inverter operation. The mechanical design has been specifically
adapted to the high requirements that occur, especially for roller table applications.

2.2 Standards and regulations


Rotating electrical machinery: EN 60034
Mounting dimensions: IEC 60072

2.3 Electrical data


Supplied from frequency inverters
The normal version is designed for a rated voltage of 400 V.
Circuit configuration for motor frame sizes
- 112M to 180L: star (the neutral point is connected in the winding overhang!)
- 200L to 400: delta
Maximum possible rated line supply voltage, 690 V.
• < 500 V with standard insulation
• > 500 V with special insulation

Other voltage-source DC link inverters:


The specified operating data is only valid in conjunction with SIMOVERT MASTERDRIVES frequency inverters.
An inquiry is necessary if third-party drive inverters are to be used.

Rating plate:
Examples

Insulation
“DURIGNIT® IR 2000” insulating system
Temperature rise F utilized to temperature rise F is standard.
Optional, temperature rise H for motors with standard insulation.

Page 3 /18
SIEMENS
Inverter-fed three-phase roller table motors

Winding temperature monitoring


All of the motors have, as standard, PTC thermistors for alarm and trip.
As an alternative, temperature detection with two KTY 84-130 (PTC thermistors for warning and trip are
eliminated).

2.4 Mechanical version

Frame and bearing endshields


The motors are fully enclosed three-phase induction motors. The ring-ribbed frames and bearing shields are
manufactured out of spheroidal graphite iron.

Paint finish
A special paint finish is standard, color RAL 7030.

Type of construction
The motors have type of construction IM B3 and have cast-on mounting feet.
The motor shaft has half-key balancing. The shaft end is, as standard, manufactured out of stainless steel,
frame sizes 112M to 180L und 280M to 400. (optionally for frame sizes 200L to 250M).
The shaft end is cylindrical acc. to DIN 748 with centering bore and key.
Special versions are available from frame size 200L and above with tapered shaft end in compliance with DIN
1448.

Terminal box
Terminal box arrangement
• For frame sizes 112M to 180L, at the non-drive end bearing endshield, optionally, on the righthand side
(Code K09). The cable entries are sealed with plugs; refer to Attachment 7. Two metric glands are
optionally available.
• From frame size 200L and above on the non-drive end on the top of the frame. Plates are bolted-on for
the cable glands. Drilled plates with two metric glands are optionally available.

Mounted equipment
A rotary pulse encoder can be mounted as option. The terminal box is additionally required on the righthand
side for frame sizes 112M to 180L (code K09). When encoders are mounted, it is not possible to mount the
terminal box at the non-drive end!
From frame size 200L onwards, in the standard version, the non-drive shaft end can be accessed to measure
the speed.

Cooling
The motors are non-ventilated and do not have their own fan.

Protection
The motors have, in the basic versions, and frame sizes
- 112M and 180L, degree of protection IP65 - optionally IP56 "non-heavy-sea"
- 200L to 400, degree of protection IP55, optionally IP56 "non-heavy-sea" or IP65

Condensation water drain holes are provided as standard.

Page 4 /18
SIEMENS
Inverter-fed three-phase roller table motors

Ambient temperature:
In the standard version, motors can be used in frame sizes
- 112M to 180L from -30 to +40 °C
- 200L to 400 from -20 to +40 °C

Bearings
The motors have roller bearings with permanent lubrication. From frame size 280M and above post lubrication
with grease quantity control. The bearings have a nominal lifetime of at least 40,000 operating hours for a
coupling output. The grease lifetime for the permanently lubricated bearings is 20,000 operating hours at a
cooling medium temperature of 40 °C.

Measuring nipples for SPM shock pulse measurement are optionally possible to check the bearings.

In order to prevent bearing currents, motors frame sizes 315L to 400 are equipped with bearing insulation as
standard. This is optional for frame sizes 225M to 280M.

For motors, frame sizes 225M to 315L, special insulated bearings are used. For motors, frame sizes 355 and
400, standard bearings are used – whereby the bearing endshields are insulated.

3 Additional documentation
1LP3 operating instructions:
http://support.automation.siemens.com/WW/view/en/11599057/133300

EG Declaration of Conformance 1LP3:


http://intra7.nes.siemens.de/qm/qm_arbeitsfelder/zertifikate/PRODUKT_ZERT/KONFORM_CE/1_NS_mot/html_
76/index.html

Page 5 /18
SIEMENS
Inverter-fed three-phase roller table motors

Rated operating data: 400 V when fed from SIMOVERT MASTERDRIVES drive inverters Attachment 1
Order No. Frame Fre- Rated Speed Efficiency Power Rated Peak Rated Surge Moment Weight
size quency power factor torque 1) transient current 2) current of inertia
2)
torque at at J
400 V 400 V
Hz kW RPM % Nm Nm A A kg/m2 kg
1LP3 118-4RL.. 112M 50 2.7 1460 83 0.74 18 54 6.5 20 0.014 55
1LP3 133-4RL.. 132M 50 4 1470 85 0.72 26 78 10 30 0.024 70
1LP3 138-4RL.. 132M 50 5.5 1470 86 0.73 36 108 14 42 0.031 80
1LP3 166-4RL.. 160L 50 7.5 1480 88 0.74 48 144 17 51 0.052 155
1LP3 168-4RL.. 160L 50 9.3 1480 89 0.74 60 180 21 63 0.07 170
1LP3 186-4RL.. 180L 50 11 1480 91 0.76 71 213 23 69 0.15 180
1LP3 188-4RL.. 180L 50 14 1480 91 0.76 90 270 29 87 0.19 195
1LP3 186-6RL.. 180L 50 8.5 980 88 0.71 83 249 20 60 0.15 190
1LP3 188-6RL.. 180L 50 11 980 89 0.71 107 321 25 75 0.19 205
1LP3 206-6RL.. 200L 20 7 390 83.2 0.54 170 680 22.5 63 0.6 300
1LP3 226-6RL.. 225M 20 10.5 390 86.1 0.59 255 1020 29 90 1.0 400
1LP3 256-6RL.. 250M 20 16.5 390 88.7 0.65 405 1620 41.5 142 1.8 600
1LP3 286-6RL.. 280M 20 26 390 89.9 0.70 640 2560 60 215 3.0 800
1LP3 316-6RL.. 315M 20 35 393 91.3 0.70 850 3400 79 280 5.2 1100
1LP3 316-8RL.. 315M 20 29 291 88.7 0.60 950 3800 79 245 5.2 1100
1LP3 356-8RL.. 355 20 44.5 294 90.4 0.60 1445 5780 118 370 9.5 1600
1LP3 406-8RL.. 400 20 66 295 91.9 0.60 2135 8540 172 540 19 2100
1) The specified rated torques are in compliance with EN 60034, duty type S1. For duty type S9 and when determining the thermal load, it must be noted that the current is not
proportional to the load torque, and in no-load and weak load phases, a stator current flows to magnetize the motors.
2) The following approximately applies: I~M in the range between the rated torque and the peak transient torque.

Page 6 /18
SIEMENS
Inverter-fed three-phase roller table motors

Rated operating points: 400 V when fed from drive inverters, from 20 to 50 Hz Attachment 2
Rated operating points at 400 V

20 Hz 30 Hz 40 Hz 50 Hz
Motor type Frame S1 S1 Surge S1 Peak S1 Surge S1 Peak S1 Surge S1 Peak S1 Surge
size rated Peak rated current rated transient rated current rated transient rated current rated transient rated current
torque transient current at 400 torque torque current at 400 torque torque current at 400 torque torque current at 400 V
torque at 400 V at 400 V at 400 V at 400
Nm V V Nm V Nm V A
Nm A A Nm Nm A A Nm A A Nm A

1LP3 118-4RL.. 112M 21 63 4 12 20 60 5 15 19 57 6 18 18 54 6.5 20


1LP3 133-4RL.. 132M 29 87 5 15 28 84 7 21 27 81 9 27 26 78 10 30
1LP3 138-4RL.. 132M 41 123 7 21 40 120 10 30 38 114 12 36 36 108 14 42
1LP3 166-4RL. 160L 54 162 8 24 53 159 12 36 51 153 14 42 48 144 17 51
1LP3 168-4RL.. 160L 67 201 10 30 66 198 14 42 63 189 17 51 60 180 21 63
1LP3 186-4RL.. 180L 80 240 12 36 77 231 16 48 74 222 19 57 71 213 23 69
1LP3 188-4RL.. 180L 110 330 14 42 103 309 19 57 97 291 24 72 90 270 29 87
1LP3 186-6RL.. 180L 100 300 10 30 93 279 14 42 87 261 17 51 83 249 20 60
1LP3 188-6RL.. 180L 128 384 13 39 120 360 17 51 112 336 22 66 107 321 25 75
1LP3 206-6RL.. 200L 170 680 22.5 63 160 620 27 83 150 560 31.5 98 140 560 35 120
1LP3 226-6RL.. 225M 255 1020 29 90 245 1000 38.5 130 235 900 46.5 154 225 900 55 190
1LP3 256-6RL.. 250M 405 1620 41.5 142 390 1620 55 215 375 1440 69 250 360 1440 82 305
1LP3 286-6RL.. 280M 640 2560 60 215 605 2280 79 285 570 2140 99 350 535 2140 114 435
1LP3 316-6RL.. 315M 850 3400 79 280 800 3200 106 390 750 3020 130 485 705 2820 150 570
1LP3 316-8RL.. 315M 950 3800 79 245 900 3600 102 345 850 3400 126 425 795 3180 148 490
1LP3 356-8RL.. 355 1445 5780 118 370 1390 5760 160 540 1335 5120 200 640 1280 5120 245 790
1LP3 406-8RL.. 400 2135 8540 172 540 1975 8000 225 750 1810 7200 270 890 1650 6600 310 1010
Roller table motors with other rated operating points are available on request.
Special insulation is required for rated line supply voltages > 500 ... 690 V!

Page 7 /18
SIEMENS
Inverter-fed three-phase roller table motors

Attachment 3
Rated operating data: Special 690 V insulation when fed from SIMOVERT MASTERDRIVES drive inverters
Order No. Frame Fre- Rated Speed Efficiency Power Rated- Peak Rated Surge Moment of Weight
size quency power factor torque 1) transient current 2) current 2) inertia
torque at at
690 V 690 V
Hz kW RPM % Nm kg/m2 kg
Nm A A
1LP3 118-4RM.. 112M 50 2.5 1460 83 0.74 16 48 3.5 11 0.014 55
1LP3 133-4RM.. 132M 50 3.8 1470 85 0.72 24.5 74 5.5 16 0.024 70
1LP3 138-4RM.. 132M 50 5.2 1470 86 0.73 34 102 7.5 22 0.031 80
1LP3 166-4RM.. 160L 50 7.1 1480 88 0.74 45 135 9.5 28 0.052 155
1LP3 168-4RM.. 160L 50 8.8 1480 89 0.74 57 171 12 36 0.07 170
1LP3 186-4RM.. 180L 50 10.5 1480 91 0.76 68 204 13 39 0.15 180
1LP3 188-4RM.. 180L 50 13.5 1480 91 0.76 87 261 17 51 0.19 195
1LP3 186-6RM.. 180L 50 8 980 88 0.71 78 234 12 36 0.15 190
1LP3 188-6RM.. 180L 50 10.5 980 89 0.71 102 306 14 42 0.19 205
1LP3 206-6RM.. 200L 20 6.3 390 83.0 0.52 155 640 12.2 34 0.6 300
1LP3 226-6RM.. 225M 20 9.6 390 86.0 0.58 235 940 16.2 48 1.0 400
1LP3 256-6RM.. 250M 20 15.5 390 88.5 0.64 380 1550 23 78 1.8 600
1LP3 286-6RM.. 280M 20 24.5 390 89.5 0.68 600 2470 33.5 120 3.0 800
1LP3 316-6RM.. 315M 20 32.5 393 91.0 0.69 790 3290 43.5 156 5.2 1100
1LP3 316-8RM.. 315M 20 26.5 291 88.3 0.58 870 3490 44 130 5.2 1100
1LP3 356-8RM.. 355 20 41 294 90.0 0.58 1330 5540 66 205 9.5 1600
1LP3 406-8RM.. 400 20 63 295 91.7 0.59 2040 8420 97 305 19 2100
1) The specified rated torques are in compliance with EN 60034, duty type S1. For duty type S9 and when determining the thermal load, it must be noted that the current is not proportional to the
load torque, and in no-load and weak load phases, a stator current flows to magnetize the motors.
2) The following approximately applies: I~M in the range between the rated torque and peak transient torque

Page 8 /18
SIEMENS
Inverter-fed three-phase roller table motors

Rated operating points: Special 690 V insulation for drive inverter operation from 20 to 50 Hz Attachment 4

Rated operating points at 690 V

20 Hz 30 Hz 40 Hz 50 Hz
Motor type Frame S1 S1 Surge S1 Peak S1 Surge S1 Peak S1 Surge S1 Peak S1 Surge
size Rated Peak Rated current Rated transient Rated- current Rated transient Rated- current Rated transient Rated- current
Torque transient current at torque torque current at torque torque current at torque torque current at
torque at 690 V 690 V at 690 V 690 V at 690 690 V at 690 V 690 V
V

Nm Nm A A Nm Nm A A Nm Nm A A Nm Nm A A

1LP3 118-4RL.. 112M 20 60 2.5 8 19 57 3 9 18 54 3.5 11 16 48 3.5 11


1LP3 133-4RL.. 132M 27.5 82 3 9 26.5 80 4 12 25.5 77 5 15 24.5 74 5.5 16
1LP3 138-4RL.. 132M 39 117 4 12 38 114 5.5 17 36 108 6.5 20 34 102 7.5 22
1LP3 166-4RL. 160L 51 153 5 15 50 150 6.5 20 48 144 8 24 45 135 9.5 28
1LP3 168-4RL.. 160L 64 192 6 18 62 186 8 24 60 180 10 30 57 171 12 36
1LP3 186-4RL.. 180L 76 228 7 21 73 219 9 27 70 210 11 33 68 204 13 39
1LP3 188-4RL.. 180L 105 315 8 24 98 294 11 33 92 276 14 42 87 261 17 51
1LP3 186-6RL.. 180L 95 285 6 18 88 264 8 24 83 249 10 30 78 234 12 36
1LP3 188-6RL.. 180L 120 360 7.5 22 113 339 10 30 105 315 13 39 102 306 14 42
1LP3 206-6RL.. 200L 155 640 12.2 34 145 590 14.8 46 140 535 17.6 54 128 540 19.4 67
1LP3 226-6RL.. 225M 235 940 16.2 48 225 970 21 73 220 875 25.5 86 210 880 30.5 108
1LP3 256-6RL.. 250M 380 1550 23 78 375 1590 31 122 355 1410 38.5 142 335 1410 45 172
1LP3 286-6RL.. 280M 600 2470 33.5 120 575 2220 44 160 535 2080 55 196 510 2100 64 245
1LP3 316-6RL.. 315M 790 3290 43.5 156 760 3140 59 220 715 2970 73 275 675 2780 84 325
1LP3 316-8RL.. 315M 870 3490 44 130 835 3340 57 185 790 3160 69 230 760 3030 83 270
1LP3 356-8RL.. 355 1330 5540 66 205 1290 5610 89 305 1240 5030 110 365 1220 5060 138 450
1LP3 406-8RL.. 400 2040 8420 97 305 1910 7930 128 430 1735 7130 152 510 1590 6540 174 580
Roller table motors with other rated operating points are available on request.
Fed from AC drive inverter with a maximum rated line supply voltage of 690 V

Page 9 /18
SIEMENS
Inverter-fed three-phase roller table motors

Rated operating data, 400 V when fed directly from the line supply Attachment 5
Order No. Frame Fre- Rated Speed Efficiency Power Rated Peak Rated current Surge Moment of Weight
size quency power2) 2)
factor torque 1) transient 2)
current 2) inertia
torque at at
400 V 400 V
Hz kW RPM % Nm A A kg/m2 kg
Nm
1LP3 118-4RL.. 112M 50 3 1450 84 0.78 20 60 6.5 20 0.014 55
1LP3 133-4RL.. 132M 50 4.5 1470 86 0.77 29 87 10 30 0.024 70
1LP3 138-4RL.. 132M 50 6 1470 87 0.77 39 117 14 42 0.031 80
1LP3 166-4RL.. 160L 50 8 1480 89 0.77 52 156 17 51 0.052 155
1LP3 168-4RL.. 160L 50 10 1480 90 0.77 65 195 21 63 0.07 170
1LP3 186-4RL.. 180L 50 12 1480 92 0.78 77 231 24 72 0.15 180
1LP3 188-4RL.. 180L 50 15 1480 92 0.78 97 291 30 90 0.19 195
1LP3 186-6RL.. 180L 50 9 980 89 0.72 88 264 21 63 0.15 190
1LP3 188-6RL.. 180L 50 11.5 980 90 0.73 112 336 25 75 0.19 205

1) The specified rated torques are in compliance with EN 60034, duty type S1. For duty type S9 and when determining the thermal load, it must be noted that the current is not proportional to the load torque, and in no-
load and weak load phases, a stator current flows to magnetize the motors.
2) The following approximately applies: I~M in the range between the rated torque and peak transient torque.

Page 10 /18
SIEMENS
Inverter-fed three-phase roller table motors

Special versions Attachment 6


Item Additional ordering Special versions 112 132 160 180 200 225 250 280 315 355 400
data –Z with code N = Normal version, X = can be optionally ordered,
1 L1Y Non-standard winding (plain text, voltage, frequency, power) X X X X X X X X X X X
1) 1) 1) 1) 1) 1) 1) 1) 1) 1)
2 A25 Motor temperature detection – temperature sensors 2 x KTY 84-130 X X X X X X X X X X X1)
3 C18 Temperature rise H at rated power and max. KT 60°C X2) X2) X2) X2) - - - - - - -
4 K52 Degree of protection IP56 (non-heavy sea) X X X X X X X X X X X
5 K50 Degree of protection IP65 N N N N X X X X X X X
6 L17 Attach the drive element provided X X X X X X X X X X X
7 G50 Measuring nipple for SPM - shock pulse measurement to check the bearings X X X X X X X X X X X
8 Y54 and special Special paint finish in other colors RAL 1002, 1013, 1015, 1019, 2003, 2004, 3000, X X X X X X X X X X X
3007, 5007, 5009, 5010, 5012, 5015, 5017, 5018, 5019, 6011, 6019, 6021, 7000,
paint finish RAL….
7001, 7004, 7011, 7016, 7022, 7031, 7032, 7033, 7035, 9001, 9002, 9005.
9 M65 Standard shaft manufactured from stainless steel N N N N X X X N N N N
10 L27 Insulated bearing cartridge - - - - - X X X N N N
11 Plain text Tapered shaft end - - - - X X X X X X X
12 K09 Terminal box mounted at the righthand side X X X X - - - - - - -
13 Plain text 2 metric glands X X X X - - - - - - -
14 Plain text Drilled plate with 2 metric glands - - - - X X X X X X X
3) 3) 3) 3)
15 H70 Mounting of LL861 900 220 rotary pulse encoder X X X X X X X X X X X
3) 3) 3) 3)
16 H71 Mounting of LL861 900 220 rotary pulse encoder to be provided X X X X X X X X X X X
3) 3) 3) 3)
17 H78 Prepared for mounting of LL861 900 220 rotary pulse encoder X X X X X X X X X X X
3) 3) 3) 3)
18 H72 Mounting of HOG9 D 1024 I rotary pulse encoder X X X X X X X X X X X
3) 3) 3) 3)
19 H74 Mounting of HOG9 rotary pulse encoder to be provided X X X X X X X X X X X
3) 3) 3) 3)
20 H79 Prepared for mounting of HOG9 D 1024 I rotary pulse encoder X X X X X X X X X X X
3) 3) 3) 3)
21 H73 Mounting of HOG10 D 1024 I rotary pulse encoder X X X X X X X X X X X
3) 3) 3) 3)
22 H75 Mounting of HOG10 rotary pulse encoder to be provided X X X X X X X X X X X
3) 3) 3) 3)
23 H80 Prepared for mounting of HOG10 D 1024 I rotary pulse encoder X X X X X X X X X X X
1) PTC thermistors eliminated. 2) Not possible for special insulation 3) Terminal box on the righthand side (K09) is additionally required. When an encoder is mounted, it is
not possible mount a terminal box at the non-drive end!

Page 11 /18
SIEMENS
Inverter-fed three-phase roller table motors

Terminal boxes for 1LP3 motors: Attachment 7

1LP3 Frame size Metric cable gland Sealing range No. of Contact stud Maximum cable
mm terminals thread cross-section that
can be connected
118 112M 1 x M32x1.5 11 - 21 6 M4 6 mm²
1 x M25x1.5 9 - 17
133, 138 132M 1 x M40x1.5 19 - 28 6 M5 10 mm²
1 x M25x1.5 9 - 17
166, 168 160L 1 x M40x1.5 19 - 28 6 M5 10 mm²
1 x M25x1.5 9 - 17
186, 188 180M 2 x M40x1.5 19 - 28 6 M5 16 mm²
2 x M20x1.5 9 - 13
206 200L 2 x M40x1.5 19 - 28 6 M6 16 mm²
2 x M20x1.5 9 - 13
226 225M 2 x M40x1.5 19 - 28 6 M6 16 mm²
2 x M20x1.5 9 - 13
256 250M 2 x M40x1.5 19 - 28 6 M6 16 mm²
2 x M20x1.5 9 - 13
286 280M 2 x M50x1.5 24 - 35 6 M8 50 mm²
2 x M20x1.5 9 - 13
316 315L 2 x M50x1.5 24 - 35 6 M8 50 mm²
2 x M20x1.5 9 - 13
356 355 2 x M50x1.5 24 - 35 6 M8 50 mm²
2 x M20x1.5 9 - 13
406 400 2 x M63x1.5 32 - 42 (40 - 48)*) 6 M10 120 mm²
2 x M20x1.5 9 - 13
*) When the customer requests it, sealing range 40 - 48 mm
1LP3 118 to 188 has cable glands with metric holes according to the table that are sealed using the appropriate plugs.
2 metric glands can be optionally supplied.
1LP3 206 to 406: The plates bolted to terminal box are undrilled. Optionally drilled, whereby 2 metric glands are supplied.
For motors, frame sizes
- 200 and 225, a plate is bolted to the non-drive end.
- 250 to 400 a plate is bolted to the non-drive end and to the righthand and lefthand side ... the 3 plates are compatible with one another.
Page 12 /18
SIEMENS
Inverter-fed three-phase roller table motors

Dimension table 1LP3 118 to 188 Attachment 8

Page 13 /18
SIEMENS
Inverter-fed three-phase roller table motors

Dimension table: 1LP3 206 to 406, standard version Attachment 9

1LP3 A AB B C HD LC H E D F GA K
206 318 390 355 133 505 740 200 110 55 16 59 19

226 356 440 400 149 550 820 225 140 60 18 64 19

256 406 490 450 168 595 915 250 140 70 20 74,5 24

286 457 550 500 190 680 1045 280 140 75 20 79,5 24

316 508 620 560 216 740 1155 315 170 85 22 90 28

356 610 700 630 254 810 1335 355 210 100 28 106 28

406 686 790 630 280 955 1385 400 210 110 28 116 35
Cable entry on the righthand side, on the lefthand side and from the non-drive end.
From frame size 250M, the 3 plates are compatible with one another

Page 14 /18
SIEMENS
Inverter-fed three-phase roller table motors

Dimension table: 1LP3 206 to 406, special version with tapered shaft end acc. to DIN 1448 Attachment 10

1LP3 A AB B C HD LC H K d l l1 d2
206 318 390 355 133 505 770 200 19 60 140 105 M42x3

226 356 440 400 149 550 820 225 19 65 140 105 M42x3

256 406 490 450 168 595 915 250 24 75 140 105 M48x3

286 457 550 500 190 680 1075 280 24 80 170 130 M56x4

316 508 620 560 216 740 1155 315 28 90 170 130 M64x4

356 610 700 630 254 810 1335 355 28 110 210 165 M80x4

406 686 790 630 280 955 1385 400 35 120 210 165 M90x4
Cable entry on the righthand side, on the lefthand side and from the non-drive end.
From frame size 250M, the 3 plates are compatible with one another.

Page 15 /18
SIEMENS
Inverter-fed three-phase roller table motors

Torque – frequency characteristic: 4-pole Attachment 11


Motor type f [Hz] 10 20 30 40 50 60 70 80 90 100
1LP3118-4RL Mn [Nm] 21.0 21.0 20.0 19.0 18.0 15.0 12.9 11.3 10.0 9.0
1LP3133-4RL Mn [Nm] 29.0 29.0 28.0 27.0 26.0 21.7 18.6 16.3 14.4 13.0
1LP3138-4RL Mn [Nm] 41.0 41.0 40.0 38.0 36.0 30.0 25.7 22.5 20.0 18.0
1LP3166-4RL Mn [Nm] 54.0 54.0 53.0 51.0 48.0 40.0 34.3 30.0 26.7 24.0
1LP3168-4RL Mn [Nm] 67.0 67.0 66.0 63.0 60.0 50.0 42.9 37.5 33.3 30.0
1LP3186-4RL Mn [Nm] 80.0 80.0 77.0 74.0 71.0 59.2 50.7 44.4 39.4 35.5
1LP3188-4RL Mn [Nm] 110.0 110.0 103.0 97.0 90.0 75.0 64.3 56.3 50.0 45.0

120
f > 50 Hz:
Rough nominal values
100 for engineering

80 1LP3118-4RL
1LP3133-4RL
Mn [Nm]

1LP3138-4RL
60 1LP3166-4RL
1LP3168-4RL
1LP3186-4RL
40
1LP3188-4RL

20

0
0 10 20 30 40 50 60 70 80 90 100
f [ Hz]

Page 16 /18
SIEMENS
Inverter-fed three-phase roller table motors

Torque – frequency characteristic: 6-pole Attachment 12


Motor type f [Hz] 10 20 30 40 50 60 70 80 90 100
1LP3186-6RL Mn [Nm] 100 100 93 87 83 69.2 59.3 51.9 46.1 41.5
1LP3188-6RL Mn [Nm] 128 128 120 112 107 89.2 76.4 66.9 59.4 53.5
1LP3206-6RL Mn [Nm] 170 170 160 150 140 117 100 88 78 70
1LP3226-6RL Mn [Nm] 255 255 245 235 225 188 161 141 125 113
1LP3256-6RL Mn [Nm] 405 405 390 375 360 300 257 225 200 180
1LP3286-6RL Mn [Nm] 640 640 605 570 535 446 382 334 297 268
1LP3316-6RL Mn [Nm] 850 850 800 750 705 588 504 441 392 353

900

f > 50 Hz:
800
Rough nominal values
700 for engineering

600 1LP3186-6RL
1LP3188-6RL
Mn [Nm]

500 1LP3206-6RL
1LP3226-6RL
400 1LP3256-6RL
1LP3286-6RL
300
1LP3316-6RL

200

100

0
0 10 20 30 40 50 60 70 80 90 100
f [ Hz]

Page 17 /18
SIEMENS
Inverter-fed three-phase roller table motors

Torque – frequency characteristic: 8-pole Attachment 13


Motor type f [Hz] 10 20 30 40 50 60 70 80 90 100
1LP3316-8RL Mn [Nm] 950 950 900 850 795 663 568 497 442 398
1LP3356-8RL Mn [Nm] 1445 1445 1390 1335 1280 1067 914 800 711 640
1LP3406-8RL Mn [Nm] 2135 2135 1975 1800 1650 1375 1179 1031 917 825

2500
f > 50 Hz:
Rough nominal values
for engineering

2000

1500
1LP3316-8RL
Mn [Nm]

1LP3356-8RL
1LP3406-8RL
1000

500

0
0 10 20 30 40 50 60 70 80 90 100
f / [Hz]

Page 18 /18

You might also like