Professional Documents
Culture Documents
All other trademarks, trade names, and service marks used herein are the rightful property of their respective
owners.
NOTICE:
Notational conventions: 1KB stands for 1,024 bytes, 1MB for 1,024 kilobytes, 1GB for 1,024 megabytes, and
1TB for 1,024 gigabytes, as is consistent with IEC (International Electrotechnical Commission) standards for
prefixes for binary and metric multiples.
©2009, Hitachi Data Systems Corporation. All Rights Reserved
HDS Academy 0069
Management Tools
y Hitachi Basic Operating System
y Hitachi Basic Operating System V
y Hitachi Resource Manager™ utility package
Module Volume Migration Software
LUN Manager/LUN Expansion
Network Data Management Protocol (NDMP) agents
Logical Unit Size Expansion (LUSE)
Cache Partition Manager feature
Cache Residency Manager feature
Storage Navigator program
Storage Navigator Modular program
Storage Navigator Modular 2 program
Replication Software
y Hitachi Universal Replicator software
y Hitachi TrueCopy® Heterogeneous Remote Replication software bundle
y Hitachi TrueCopy® Remote Replication software bundle (for modular systems)
y Hitachi TrueCopy® Synchronous software
y Hitachi TrueCopy® Asynchronous software
Other Software
y Hitachi Backup and Recovery software, powered by CommVault®
y Hitachi Backup Services Manager software, powered by APTARE®
y Hitachi Business Continuity Manager software
y Hitachi Command Control Interface (CCI) Software
y Hitachi Dynamic Provisioning software
y Hitachi Storage Resource Management Solutions
y Hitachi Volume Migration software
y Hi-Track® Monitor
LAB ACTIVITY 1 COMPONENT LOCATIONS AND POWERING UP THE SYSTEM .................. 1-1
LAB ACTIVITY 2 WEB ACCESS: NORMAL MODE AND COLLECT A TRACE ....................... 2-1
LAB ACTIVITY 3 STORAGE NAVIGATOR MODULAR 2: INSTALLATION & INITIAL SETUP .... 3-1
LAB ACTIVITY 4 STORAGE NAVIGATOR MODULAR 2: BASIC OPERATIONS ..................... 4-1
LAB ACTIVITY 5 BASIC OPERATIONS: HOST GROUPS AND LUN MAPPING ..................... 5-1
LAB ACTIVITY 6 BASIC OPERATIONS: LU EXPANSION AND LU GROW/SHRINK .............. 6-1
LAB ACTIVITY 7 BASIC OPERATIONS: ONLINE RAID GROUP EXPANSION ...................... 7-1
LAB ACTIVITY 8 BASIC OPERATIONS: STORAGE NAVIGATOR MODULAR 2 CLI .............. 8-1
LAB ACTIVITY 9 BASIC OPERATIONS: CACHE PARTITION MANAGER FEATURE............... 9-1
LAB ACTIVITY 10 BASIC OPERATIONS: PERFORMANCE MONITOR FEATURE .................. 10-1
LAB ACTIVITY 11 REMOVE AND ADD AN EXPANSION TRAY ........................................... 11-1
LAB ACTIVITY 12 HITACHI STORAGE NAVIGATOR MODULAR 2 ADVANCED OPERATIONS 12-1
LAB ACTIVITY 13 HARDWARE REPLACEMENT ............................................................. 13-1
LAB ACTIVITY 14 DISRUPTIVE MICROCODE LOAD: WEB TOOL...................................... 14-1
Procedure
The students will be divided into lab groups and will perform the lab project on the
lab equipment assigned to them by their instructor.
Disclaimer
These lab projects are designed to be used in a training environment to transfer
concepts of using and configuring the functions and features of the Adaptable
Modular Storage 2000 system to the learner. They are not intended to replace any
published Hitachi users guide concerning the topics and procedures presented in
the lab project. When attempting to use or configure any function or feature of the
Adaptable Modular Storage system the user should always refer to the specific user
guide.
Objectives
Upon completion of the lab project, the learner should be able to:
y Identify and locate hardware components
y Identify management and maintenance LAN connections
y Identify Fibre Channel connections
y Verify the connections of the ENC cables from the base unit to the accompanying
expansion units
y Apply power to the rack Power Distribution Units (PDUs)
y Power up the storage system and verify its Ready status
Activity
1. Go to the front of your assigned storage system and identify each module that
comprises your assigned storage system, filling in the blanks below as you view
your assigned system from bottom to top.
What type of module is at the bottom (the first module) of your assigned storage
system? _______________________________
What type of modules are stacked above the bottom (or first module) module?
________________________________
List the names and IP address of the storage system:
Controller 0 LAN Port = IP Address =
Controller 0 Maintenance Port = IP Address =
Controller 1 LAN Port = IP Address =
Controller 1 Maintenance Port = IP Address =
2. Go to the rear of the storage system and look at the bottom module. How does it
differ from the second module up from the bottom? ________________________
_______________________________________________________________________
Note: If your rack has more than one Adaptable Modular Storage (AMS) 2000
system installed, wait for the other lab group to reach this step of the lab project.
5. Return to the front of the storage system and set the rocker power switch of each
base unit to ON and wait for the two storage systems to power up watching how
all the LEDs behave during the power-up process.
6. Looking at the physical disk drives can you identify the SAS and/or SATA disk
drives? YES NO
Lab 1 - End
Activity
Preliminary Notes
y This Lab assumes that your storage system is attached via an Ethernet link to the
browser Host PC. If not, you should arrange to make a suitable connection. Ping
the storage system to check the connection.
y Microsoft Windows 2003 will require changing the browser security setting from
High to Medium.
y If possible, set the PC to Disable DNS or else the connection will take a very long
time.
y Set the Browser so that any Proxy Server is not used.
2. In the System Status panel click on the disk icon (depending on the number of
expansion units you should see something like the following screen shot).
3. Click the Main link to return to the main screen and then click on one of the other
component icons. Repeat this process until you have inspected each component.
Note: Answers to embedded questions like the following question can be found at
the rear of the lab project.
After the drive spun up what did the Drive Access LED do? ____________________
__________________________________________________________________________
6. Click the Warning Information link (you should see messages similar to the
example below).
7. Back out (about 1 inch) any other drive except one of the first five drives.
8. Click the Disk Drive link.
Why was copy-back of this drive not performed like it was for the third drive?
________________________________________________________________________
________________________________________________________________________
Collect a Trace
When in normal mode, the Adaptable Module Storage system allows the collection
of trace information two ways: Simple Trace and CTL Alarm Trace.
The information is stored in the cache during normal operation and before
performing either operation the user should be aware of the size of the binary dump
file that will be written to the hard disk of the connected host PC.
Simple Trace: Requires a minimum of 30MB of free space.
CTL Alarm Trace: Requires a minimum of 20MB of free space (40MB
if Copy-on-Write Snapshot software is used).
3. Click OK.
When the information has been collected (takes several minutes), the following
prompt appears:
5. Click Save.
Note: You could save the file to any folder you choose.
6. Click Save to save it to the Local Disk.
IF the file already exists, THEN the following prompt occurs. Click Yes.
Note: Since your subsystem has not experienced a controller blockage, trace
information has not been collected and you will not be able to select one of the
controllers and perform the dump. If blockage trace information was available, the
CTL Alarm Trace window would display additional information and you would
be able to select a controller and continue the process.
2. If you previously turned off the popup blocker, turn it back on.
3. Close your browser.
Note: As software products are enabled, the left hand menu of the web browser
screen will list the individual products. At the moment, your screen should not
have any enabled products listed. You should plan to return to the web browser to
verify that the products are listed as you enable them during the following lab
projects.
What does the I/F icon identify? Identifies the front end interface boards.
Page 2-4
Did the Drive Failure LED turn red? Yes — and it remains on until the drive spins
up.
After the drive spun up what did the Drive Access LED do?
The Access LED flashed on and off very quickly indicating the microcode from
drive #1 was restored to what the system thinks was a new disk (drive #3).
Page 2-5
Why was copy-back of this drive not performed like it was for the third drive?
The drive was not one of the microcode disks and was not part of a RAID Group.
Page 2-7
What happens when you open the file?
Since it is a binary file you see what appears to be garbage.
What would you do with the trace file? Email it to Hitachi Data Systems Technical
Resource Center (TRC).
Web Access
1. What happens if one of the first five disk drives is replaced and no RAID Group
exists on these drives?
3. If a drive other than one of the first five drives is removed from the system and it
was not part of a RAID Group, does the system enter the Warning state?
4. How many types of trace information can be collected on the DF800 when in normal
mode?
6. What type of file is created and saved on the hard disk of the connected PC?
7. How much free space is required to perform a CTL Alarm Trace when Copy-on-
Write Snapshot software is enabled?
8. What is the file name when the Simple Trace is collected from Control Unit 0 and
then Control Unit 1?
Lab 2 – End
Activity
4. In case of a transforms error, click OK after the error message appears and then drill
to the following directory:
C:\Documents and Settings\Administrator\ApplicationData\Sun\Java\jre1.6.0_07
6. Click Accept.
7. Click Finish and then close the C:\Documents and Settings window.
3. Click Next.
4. Click Next.
See next page for resulting screen shot.
5. Enter the IP address of your assigned management server and then click Next to
this screen and the following screen to start the copying of the files.
The load will take approximately 10 minutes.
6. Click Finish at the completion screen.
7. Close the C:\DF800 Class\Class Software window.
Note: Two screens open. The top screen is the Login screen and the screen behind
the Login screen would launch the Login screen again.
See next page for resulting screen shots.
2. When the application loads, enter the system and manager strings.
In a few moments, SMN2 will automatically launch the Add Array wizard.
3. Click Next.
See next page for resulting screen shot.
The wizard prompts you to enter the IP addresses of the LAN ports on the
AMS2000 controllers.
Note: If the user wanted to utilize the SSL protocol for secure LAN connections
and used SSL certificates, then Secure Port would be selected. In class you will
use Non-secure Port connections.
4. Enter the IP addresses for your assigned storage system and then click Next.
5. Click Finish and wait a few moments until the registered array is displayed on the
Arrays screen.
6. Move the slide bar to expose the IP Addresses and verify that your system is the
system that was registered.
Verify that the Status of your system is Normal and consult your instructor if
status other than normal is being indicated.
7. Click on your Array Name entry to start your initial configuration.
See next page for resulting screen shot.
4. Click Close.
5. Exit the SNM2 session by clicking the Logout button and then OK to the small
result prompt.
6. Close the SNM2 Login window.
7. From the Start menu, select Settings > Control Panel, then double-click the Java
icon.
8. Click the Java tab and then in the resulting screen, click the View button of the Java
Applet Runtime Settings parameter.
See next page for resulting screen shot.
9. Enter –Xmx192m in the Java Runtime Parameter panel and click OK to reserve
192MB of memory for Java.
10. Click OK at the Java Control Panel to complete the operation.
11. Open the web browser and launch Storage Navigator Modular 2 again.
12. Log in as system, giving the manager password.
13. Connect to your assigned array.
14. Expand Settings and then click the Advanced Settings function again.
15. Click the Open Advanced Settings button.
After a short delay with a Java icon displayed, the following window appears:
Initial Setup
1. From the Common Array Tasks panel, click Initial Setup. The wizard prompts you
to set up an email alert, set management ports, and set up the iSCSI ports.
2. Click Next.
3. Since you will not configure this parameter in class, click Next.
4. If the customer wanted to change the IP addresses or use DHCP, this is where the
changes would be set. Since the displayed configuration is the configuration that is
required in class, click Next.
See next page for resulting screen shot.
Note: The above screen shot is from an AMS 2300. If you are on an AMS 2100,
then you will see only four ports instead of eight ports.
5. Since the Americas education host systems and storage systems are connected to
the Brocade 48000 switch, make the following changes to the Fibre Channel
settings for ports 0A, 0B, 1A, and 1B:
Transfer Rate: 4Gbps
Topology: Point-to-Point
Port Address: Leave as is since this parameter is not used when connected
to a switch and in Point-to-Point mode (fabric mode)
6. Click Next after configuring all four ports.
See next page for resulting screen shot.
7. Select the last drive in the controller (tray 00) and the first extension module (tray
01) to be spare drives, and then click Next (you are tagging two spare drives).
Note: You may have to select the next page in order to see all the available drives.
9. Click Next at this first confirmation screen and the next three confirmation screens,
assuming that you entered all the proceeding information correctly.
10. If the configuration is what you wanted, click Confirm at the last confirmation
screen and wait for the initial configuration to be applied.
3. Double-click (open) each .plk file to identify the one with the base license keys.
You should see something similar to the following:
When installing Program Product (PP) keys, the key of an individual PP can be
copied to the SNM2 license window or you can point to the .plk file and load all
the keys at once. The key is the 48 character string identified in the above example.
Important Note:
If you obtained the key file from a network share server, then edit the file and make
sure it contains only the keys listed in the screen shot above. This is done so this lab
project and following lab projects will run as documented. The course lab projects
assume only the above listed keys are installed.
4. Close the Notepad editor for any open key file.
5. Click on the Array Name of your system to again connect to your assigned array.
6. From the Common Array Tasks panel click Install License.
7. Since you will install all the keys at once, select Key File and click Browse.
8. Drill to the folder containing your key file, select the file and click Open.
The path to the key file should be displayed in the Key File panel of the Install
License window.
9. Click OK at the Install License window and then Confirm at the warning prompt.
After a brief delay, the following message appears if any of the keys require a
reboot of the array. Program Products that affect the configuration of the cache, and
Account Authentication will require a reboot. Program Products that affect the
cache are: Cache Residency Manager and Copy-on-Write SnapShot.
Note: If you attempt to install Copy-on-Write Snapshot software and Cache
Partition Manager at the same time (as you are doing), only Copy-on-Write is
installed.
Later in the class when the Cache Partition Manager is covered, you will be
instructed to install the key manually.
10. Click Close and notice that you are disconnected from your array.
Note: You were informed that a reboot is required. The reboot will be
performed in a few minutes after the investigation of Account Authentication.
11. Attempt to connect to your array again and see what happens.
Because the Account Authentication key was in the key file (look back at the key
file), the Account Authentication feature is active and you are being prompted for
a User ID and Password.
12. Try entering the system and manager strings to log in.
As you can see, the initial user ID and password are not accepted.
If you had commented out the Account Authentication key in the key file before
you loaded the keys, you would not be blocked from logging in using the initial
values.
13. Log in using the following strings (this is a built-in account and password):
User ID = root
Password = storage
Notice fewer functions are now available in the Common Array Tasks panel
and Status of the system is in question (?).
14. From the Arrays panel, expand Security and click on Account Authentication.
You can see that the root account is a built-in account. The root account could be
used to add new accounts (users) using the Add Account button.
In a few minutes you will create a new Administrator account and then disable
the Account Authentication and SNMP features.
This is the error that occurs when SNMP is installed. You have not configured the
SNMP parameters and SNM2 is complaining because it does not know where the
SNMP server is (this is discussed later in the course).
Note: Another way to view the warning is via the Event Log of SNM2. This is
displayed using the Alerts & Events function and then selecting the Event Log.
3. Close the Web Tool.
5. Select your array using its check box and then click the Reboot Array button.
7. Check the Yes check box and then click Reboot Array and wait for the reboot to
complete.
8. Click Close.
9. Connect to your array unit and notice that you are not prompted for the
Administrator User ID and Password (you gave them before the reboot).
10. From the Array panel, expand Settings and click on Licenses.
See next page for resulting screen shot.
11. Check the SNMP-Agent and Account program products and then click the Change
Status button.
Note: If you had not rebooted the array, the Install, De-install, and Change Status
buttons would not be present in the Licenses panel.
12. Remove the check from the Enable check box and then click OK.
See next page for resulting screen shot.
If you want to go back and practice what you have learned, feel free to do so, but
keep in mind that you must complete the review questions and have them ready for
review when the class reconvenes in the classroom.
Make sure you leave the system in the same state that it was in at the end of the
guided portion of the lab project. This insures that the system will be in a state that
supports the following lab projects.
SNM2 Configuration
2. If the SNM2 management server is running Hitachi Storage Command Suite before
the installation of SNM2, what must be done before installing SNM2?
4. When launching SNM2, what port number is used in the URL, and can the user
change this port number?
6. What is the string that you need to set for the Java Runtime Parameter?
7. When installed, some Program Products will require a reboot of the array. What PPs
cause a reboot when installed?
8. What are the strings of the built-in user account that is activated when you install
the Account Authentication program product?
User ID =
Password =
Lab 3 – End
Activity
Note: Depending on the model of your assigned education AMS2000, the type of
disk drives in the first tray (the control module) may be different.
4. Click OK to accept the default settings – the drives will be selected automatically.
See next page for resulting screen shot.
By default, if no RAID Groups exist on the system, the following RAID Group is
created:
6. Click on the icon of RAID Group 000 and then click on the Assigned Drives tab in
the resulting window.
See next page for resulting screen shot.
After the above command your RAID Group configuration should look something
like the screen on the next page. Your drive configuration may be different, but
you should have the three RAID Groups.
9. Select the check box to the left of RG 001 and then click Delete RG, and then Confirm
the deletion.
2. Select the following parameters and then click the Advanced tab.
RAID Group number = 000
LUN = 0000
Capacity = 1GB
Note: The Advanced setting allows the user to specify the Stripe Size, if the new
LUN is to be formatted, or create the LUN automatically or manually from free
space. If the Format the Logical Unit box is un-checked, then the LUN could be
formatted manually later.
If the OK button had been clicked (previous screen), then the default settings of the
Stripe Size (256KB), Format (Yes), and Set Automatically would be selected.
Later in the course, the stripe size setting is discussed when the Cache Partition
Manager is covered.
3. Click OK to accept the default settings from this screen and the settings that you
made via the previous screen.
See next page for resulting screen shot.
This window allows you to map the new LU to a Port and Host Group.
Depending on the model type of your assigned AMS2000 system, the number of
Fibre Channel ports may be different.
4. Click Close. At this time mapping will not be performed. Host Groups and LUN
mapping are covered later in the course.
Also, at this time, ignore the Cache Partition information. The cache partition to
which a new LUN is assigned is discussed later in the course with Cache Partition
Manager.
5. Click on the Create LU button again and create five additional LUs per the
following parameters, and remember click Close at the window concerning Host
Group mapping:
RAID Group number = 000
LUN = 0001
Capacity = 1 GB
Stripe Size = 512KB
Keep the defaults: Format the Logical Unit and Set Automatically selected
7. Click Close.
8. Select LUN 0002 and click the Delete LU button.
9. Check the Yes, I have read the above warning box and click Confirm to delete the
LU, then click Close at the “deleted successfully” message.
Your LU configuration should look like the following:
2. In the Array Unit panel, select Configuration Settings and click the Set button.
If you want to go back and practice what you have learned, feel free to do so, but keep
in mind that you must complete the review questions and have them ready for review
when the class reconvenes in the classroom.
Make sure you leave the system in the same state that it was in at the end of the
guided portion of the lab project – this insures that the system will be in a state that
supports the following lab projects.
1. What two methods are available for the creation of RAID Groups?
2. When using the Manual Selection method of creating a RAID Group, drives of
different speeds can be combined into the same RAID Group.
A. TRUE
B. FALSE
3. What is the maximum number of Parity Groups HDS recommends per RAID
Group?
5. When you create a LUN manually, you have the option to map it to a Host Group.
A. TRUE
B. FALSE
6. After a failed drive has been replaced, you do not want to copy back the data from
the spare to the replaced drive. How should the parameter Spare Drive Operation
Mode be set?
A. Variable
B. Fixed
Lab 4 - End
Activity
3. Record the WWNs of the two HBA ports (your WWNs will be different from the
captured screen shot and should reflect the WWNs of your assigned host system).
First port = __________________________________
Second port = __________________________________
4. Close the HBAnyware GUI.
5. Log in to SNM2 and then connect to your assigned storage array.
7. Click on FC Port 0A and record the WWPN of the port and then repeat the process
for Port 1A.
Port 0A = __________________________________
Port 1A = __________________________________
Notice that each port contains a default Host Group 000 (default name is
000:G000).
2. Click the Host Group Security tab.
Notice that Host Group Security, by default, is disabled. Also, depending on the
model that you are connected to, the number of ports may be different.
3. Assuming that your Windows host system is connected to ports 0A and 1A, enable
the security for these two ports, or enable the ports that your host server is
connected to. Use the Change Host Group Security button to make the change on
the selected ports and when finished your settings should look like the following:
Note: If you have followed the steps of the previous lab project that instructed
you to create RAID Groups and LUNs, then your configuration should look like
the screen shot above. The next few steps of this lab project will have you map the
two 1 GB LUNs from RAID Group 000 to this Host Group. If your RAID
Group/LUN configuration is different, then select two other LUNs and make note
of which two LUNs you use.
You will create the following LUN mapping configuration:
Internal LUN 0000 mapped to H-LUN 0000
Internal LUN 0001 mapped to H-LUN 0001
4. In the Available Logical Units panel, check the box for LUN 0000 and LUN 0001.
5. Leave H-LUN 0000 selected in the H-LUNs panel, click the Add button to map the
two internal LUNs to your Host Group.
6. Using the right-hand scroll bar, pull the screen down to the bottom and click the
OK button and then Close at the completion screen.
See following page for resulting screen shot.
7. Repeat steps 1 – 6 for the Create Host Groups and Map LUNs (see page 5-5)
portion of this lab project for Port 1A, naming the host group Windows_Port_1A.
You will map the same two internal LUNs to this Host Group. Also, set the Host
Group Number to 001 (same number used for the host group of Port 0A). When
selecting the WWN, you should see and then select the other WWN of your host
HBA. This time you will have to check the 1A box and uncheck the 0A box for the
Create to parameter on the Create Host Group window. When finished, your host
group window should look like the following:
IF the Links are down for Ports 0A and 1A, THEN your instructor will have to
connect to the switch and perform the following:
Portdisable and then portenable for the switch ports where your storage
array ports are connected.
After the switch ports are toggled, verify that the Link Status of the storage arrays
ports are now indicating LinkUP(F_Port Connected).
2. Select the first port and then select Reset Adapter from the Adapter drop-down
menu.
3. Click Yes.
4. Repeat steps 2 and 3 for the second port.
5. Click the Refresh button.
See next page for resulting screen shot.
6. Fully expand both ports to verify the discovery. You should see the following:
If the HBA does not indicate that both LUNs on both ports have been discovered,
then ask your instructor for help to determine the reason.
The problem could be your configuration on the array, the switch, or the HBA.
The lab project does not instruct you how to set up Persistent Binding even
though its use is strongly recommended when on a switch. The fixed configuration
of the education centers environment should work and the LUNs should have
been discovered – the HBAs are set for Automatic LUN discovery.
If your array is configured correctly and the switch is indicating correct logins,
then your instructor may have to walk you through setting up Persistent Binding
to see if this corrects the problem.
7. Close the HBAnyware window.
8. From the desktop, right-click on the My Computer icon and select Manage, then
click on the Disk Management link in the resulting window. Also, click Cancel if
the Initialize and Convert Disk Wizard window appears.
Note: You may need to select Rescan Disks from the Action drop-down menu.
And be patient, it may take Windows a few minutes to detect the LUNs.
9. Right-click on one of the little red circles and select Initialize Disk.
See next page for resulting screen shot.
If you want to go back and practice what you have learned, feel free to do so, but keep
in mind that you must complete the review questions and have them ready for review
when the class reconvenes in the classroom.
Make sure you leave the system in the same state that it was in at the end of the
guided portion of the lab project – this insures that the system will be in a state that
supports the following lab projects.
5. The same internal LU, once mapped to a Host Group, cannot be mapped to another
Host Group.
A. TRUE
B. FALSE
Lab 5– End
Activity
Remember, internal LUNs 0000 and 0001 are mapped as Host LUNs 0000 and 0001 to
the Windows host group of ports 0A and 1A.
The next few steps of this lab project will have you create an Expanded LUN from
LUNs 0004 and 0005.
If your RAID Group/LUN configuration is different, then create and/or use two
LUNs of your choosing.
1. From your assigned classroom PC, use the Remote Desktop Connection Utility
and connect to your assigned management server in the lab.
2. Login to SNM2 and then connect to your assigned storage array.
3. From the Arrays panel, expand Groups and then click on RAID Groups and select
the Logical Units tab. In the resulting window, select LUN 0004 and click the
Change LU Capacity button.
See next page for resulting screen shot.
4. Select Add logical units as the Method of Capacity Setting, check LUN 0005 and
then click OK.
5. Check Yes and then the Confirm button, then Close at the success window.
See next page for resulting screen shot.
7. Check Yes and then click Confirm and then Close at the success window.
8. Click the Refresh Information button to verify that the format of LUN 0004 has
finished (you will have to use the slide bar to position the window to expose the
LUN Status).
2. Check the Windows_Port_0A Host Group and then click the Edit Host Group
button.
3. Click the Logical Unit tab in the Edit Host Groups window.
Note: In an actual production environment, any involved LUNs should be backed
up before beginning the expansion process.
4. In the Assigned Logical Units panel, check H-LUN 0000, click the Remove button
and then pull down the window and click the OK button.
5. Click Close at the completion window.
6. Repeat Steps 2 – 5 for the other Windows Host Group on Port 1A.
7. From the Arrays panel, expand Groups and then click on RAID Groups and select
the Logical Units tab. In the resulting window, select LUN 0000 and click the
Change LU Capacity button.
8. Click the Input Capacity Options tab, then select Input Capacity as the Method of
Capacity Setting, specify 5 GB as the new capacity, and then click OK.
9. Map LUN 0000, the expanded LUN, to the two Windows Host Groups again and
then confirm that the Windows host detects the new LUN. Create a partition in the
new portion of the disk and do not choose Quick Format as one of your choices.
And be patient, it may take Windows a few minutes to discover the change.
Your disk management screen should look something like the following.
Note: In an actual production environment, any backed data from the original
LUNs would be restored as a last step.
10. Close the Computer Management window and logout of SNM2.
LUN Expansion
4. LUNs to be expanded must come from RAID Groups that use the same type of disk
drives, but the RPMs can be different.
A. TRUE
B. FALSE
5. Of the LUNs used to create the unified LUN, what LUN is the LUN that should be
mapped to the host system?
7. After creating the unified LUN, what should be done before mapping it to a host
system?
Lab 6 – End
Activity
1. From your assigned classroom PC, use the Remote Desktop Connection Utility
and connect to your assigned management server in the lab.
2. Login to SNM2 and then connect to your assigned storage array.
3. From the Arrays panel, expand Groups and then click on RAID Groups.
4. In the RAID Group panel, check RAID Group 000 and click the Expand RG
button.
See next page for resulting screen shot.
5. Select the first drive in the Assignable Drive panel and click OK.
6. Check the Yes box, click the Confirm button and then Close at the completion
window.
7. Click on the icon for RAID Group 000 followed by clicking the Assigned Drives
tab.
See next page for resulting screen shot.
9. Logout of SNM2
Lab 7 – End
Activity
1. From your assigned classroom PC, use the Remote Desktop Connection Utility
and connect to your assigned management server in the lab.
2. Login to SNM2 and then connect to your assigned storage array.
3. For the time being, minimize the SNM2 windows. Later in the lab project you will
open the SNM2 GUI to verify changes that you made using the CLI.
4. Drill to the following folder of your Windows host system:
C:\DF800 Class\Class Software\HSNM2WIN_0620\Windows CLI.
5. Double-click on HSNM2-0620-W-CLI.exe.
See next page for resulting screen shot.
6. Click Next to this prompt, and Next and Install to the following two prompts.
7. Click Finish at the completion prompt.
8. Drill to the following folder:
C:\Program Files\Storage Navigator Modular 2 CLI
9. Double-click on startsnmen.bat to launch the CLI.
10. Execute the set command to verify that the environment variable
STONAVM_HOME was set during the CLI installation process.
See next page for resulting screen shot.
11. Execute the aupasswd command and enter df800 as the password.
12. Execute the following command to register your storage array:
auunitadd –unit array01 –LAN –ctl0 XXX.XX.X.XXX -ctl1 XXX.XX.X.XXX
where XXX.XX.X.XXX = the IP addresses of the controllers of your
assigned DF800.
13. Execute the following command to display any existing RAID Groups (you
should see something similar to the following screen shot):
aurgref –unit array01 -g
Note: The next command will create a RAID 5, 2+1 RAID Group using SAS
drives. Because of the assumed beginning configuration of the array at the start
of the lab project, the command will specify disks 06, 07, and 08 of Tray 01. Since
your system may have a different disk configuration, you should restore the
SNM2 GUI and verify what disk drives are available and modify the
following command to reflect the drive numbers that you have to use.
14. Execute the following command to create the new RAID Group 3 and answer Y
to the confirmation prompt:
aurgadd –unit array01 -rg 3 -RAID5 –drive 1.6 1.7 1.8 -pnum 1
15. Using the SNM2 GUI, display the arrays configured RAID Groups and verify
that the CLI command added the new group (don’t forget to refresh the GUI). If
you want, you could also execute the aurgref command to verify the addition.
16. Execute the following command to display the currently configured LUNs:
auluref –unit array01 -g
17. Execute the following command to create a new LUN 6, remembering that your
LUN configuration may be different:
auluadd –unit array01 –lu 6 –rg 0 –size 1g –stripesize 256 -noluformat
18. Execute the following command to again display configured LUNs:
auluref –unit array01 -g
By now you should have the idea that the CLI is not very user-friendly, but it works.
If you want to go back and practice what you have learned, feel free to do so, but
keep in mind that you need to complete the review questions and have them ready
for review when the class reconvenes in the classroom.
Make sure you leave the system in the same state that it was in at the end of the
guided portion of the lab project – this insures that the system will be in a state that
supports the following lab projects.
2. What system variable must be set before you attempt to use the CLI on a Windows
system?
3. The CLI does not know about the GUI installed on the same host system or another
host system.
A. TRUE
B. FALSE
A. TRUE
B. FALSE
Lab 8 – End
Activity
1. From your assigned classroom PC, use the Remote Desktop Connection Utility
and connect to your assigned management server in the lab.
2. Log in to Storage Navigator Modular 2 (SNM2) and then connect to your assigned
storage array.
3. From the Arrays panel, expand Settings and then click on Advanced Settings.
4. From the Advanced Settings panel, click the Open Advanced Settings button.
Notice that the Cache Partition Manager (CPM) feature is not listed. If you
remember, when the license keys were installed earlier in the class, CPM was not
installed because Copy-on-Write Snapshot was specified to install at the same
time. The two features cannot be installed at the same time, therefore CPM was not
installed.
5. Close the Advanced Settings window and install the individual key for CPM,
returning to the Advanced Settings window after the key is installed.
See next page for Advanced Settings after CPM is installed.
Notice that the only two partitions are available (00 and 01). Partition 00 is owned
by Controller 0 and Partition 01 is owned by Controller 1.
7. Click the Set button.
See next page for resulting screen shot.
Notice that all the cache space defined by the User Area is equal to 1480 MB.
Note: Depending on the model of Adaptable Modular Storage you are connected
to, the amount of cache memory may be different. If you see a different size from
that indicated by the lab screen shots, use pencil and paper to make note of the
differences and make adjustments as required as you progress through the
following steps.
For the example above, the 1480 MB is divided equally between the two
controllers and their corresponding partitions: they currently have 740 MB (the
1480 MB divided by 2).
Amount of space is identified by a factor of 10 MB chunks: 74 x 10 MB = 740 MB.
The amount of Free Space per controller is = 0 MB, therefore no sub-partitions
could be created.
8. Double-click in the Size(x10MB) panel for Partition 00, delete the 74, and then key
in 20 (this will release 54 chunks to free space, leaving the minimum of 20 chunks).
Remember, the number of released chunks may be different for your array; if so,
make note of the number of chunks released for your array.
9. Repeat step 8 for Partition 01.
10. Click the OK button to release the space and see next page for resulting prompt.
13. Check the Restart now box and then click OK.
14. Check the OK to reboot box and then click OK to reboot the array and wait.
15. Click OK and then Close to the Please close this browser prompt.
Note: You will be placed back at the Advanced Settings window.
16. Click the Open Advanced Settings button again.
17. Select Cache Partition and then click the Set button.
Notice that each controller now has 1080 MB of cache. You release 54 chunks of
space from each master partition. Since each controller has a mirror area for the
other controller, the space that is released to Free Space is twice the released
number of chunks.
18. Click the Add button, and select a Segment Size of 64 KB.
Note: Sub-partition 02 will be owned by Controller 0.
19. Click the Add button again, and select a Segment Size of 256 KB and select
Controller 1 as the owner.
See next page for how the configuration should look.
20. Click OK and respond to the resulting prompts as you did when you released
space from the master partitions.
3. Crate a new LUN using the following settings, and when prompted to map the
new LUN to a Host Group, click Close.
RAID Group = 000
LUN number = 0008
Capacity = 1 GB
4. Click the Advanced tab and select the following, then click OK.
Stripe Size = 64 KB
Cache Partition = 02
Pair Cache Partition = Auto
5. Click Close at the screen prompting you to map the new LUN to a FC Port.
6. Create another LUN using the following settings, and when prompted to map the
new LUN to a Host Group, click Close (see next page for result).
RAID Group = 000
LUN number = 0009
Capacity = 1 GB
Stripe Size = 256 KB
Cache Partition = 03
Pair Cache Partition = Auto
7. Logout of SNM2.
If you want to go back and practice what you have learned, feel free to do so, but keep
in mind that you need to complete the review questions and have them ready for
review when the class reconvenes in the classroom.
Make sure you leave the system in the same state that it was in at the end of the
guided portion of the lab project – this insures that the system will be in a state that
supports the following lab projects.
4. When you re-configure the cache, adding or deleting a partition, a restart is not
required.
A. TRUE
B. FALSE
5. Cache Partitions can be different sizes and have different cache segment sizes.
A. TRUE
B. FALSE
6. If you create two partitions of different sizes with each partition on a different
controller, after the restart the Free Area of each controller will also be different.
A. TRUE
B. FALSE
Lab 9 – End
Activity
Note: This is the configuration that you should have created in earlier lab
projects. Array internal LUNs 0000 and 0001, created from RAID Group 0 and
mapped to the two Windows Host Groups that you created on Ports 0A and 1A.
LUN 0000 (Disk 1) was initially created as a 1GB LUN, but you added 4GB to it
using the LU Expansion function.
LUN 0001 (Disk 2) was created as a 1GB LUN.
Because the two LUNs are mapped to both Host Groups that your server has access to,
the server thinks it has access to four LUNs – two LUNs on both paths.
If your configuration does not match the expected configuration, then you will have
trouble following the remaining steps of this lab project.
3. Leave Enter the name of the license key file selected and click Next.
4. In the resulting prompt, click the Browse button and browse to the following
folder:
C:\SOFTWARE\HDLM\HDLM_Key
5. Select the file HDS HDLM 20051017 205738.plk and click Open.
6. Click Next and then OK at the The permanent license was installed prompt.
7. Click Next.
See next page for resulting screen shot.
8. Leave the Hitachi subsystem selected and click Next (the installation should start).
9. When the Install Complete prompt appears, close any open windows and then
select the Yes, I want to restart my computer now radio button and click Finish
and wait for the reboot to complete.
Note: You may want to execute a ping –t to your server to verify when it comes
back up. Also, once it starts responding to the ping, wait a couple of more minutes
before attempting to connect to your server.
10. Connect to your server, start SNM2 and connect to your array.
11. Go to RAID Groups Æ Logical Units and delete LUNs 0000 and 0001.
12. Create a new LUN 0000 and 0001 from RAID Group 002, specifying a size of
20GB and assign them to partitions 00 and 01 respectively. Click Close at the
window that prompts you to map the new LUNs.
The larger size LUNs will allow you to issue I/O to the LUNs using Iometer and
not overflow the LUNs.
13. Keep refreshing your array to verify when the format of the new LUNs completes
(takes a few minutes).
14. Once the format completes, re-map LUNs 0000 and 0001 to both Windows host
groups as Host LUNs 0000 and 0001 (as before).
15. Wait a couple of minutes, then launch the Windows Disk Management utility
and verify that the OS has again discovered the LUNs (you may have to execute
the Rescan Disks function).
See next page for resulting screen shot.
Notice that the OS, because of HDLM, is now only displaying the primary path
(two disks listed instead of four).
16. Initialize the two disks and create a partition in each one (one at a time), but do
not choose Quick Format as one of your choices – let the OS fully format the
disks. The format of each disk takes about 30 seconds; be patient and create the
partition in each disk one at a time (wait for disk 1 to complete formatting before
you work on disk 2).
Start HDLM
Note: Dynamic Link Manger software version 6.0.1-00 does not totally support the
Adaptable Modular Storage. When Dynamic Link Manger is launched, the Path List
screen is displayed and if the Configuration screen tab is clicked, a message appears
stating the Configuration View function is not supported. This is okay, since the Path
List screen gives everything needed to complete the lab project.
1. From the Start popup menu, select the following to launch the software:
Start Æ Programs Æ Dynamic Link Manager Æ HDLM GUI
See next page for resulting screen shot.
2. In the Host tree panel, expand the icon for your listed storage array and then pull
the slide bar to the right to expose the Owner and I/O count columns.
If you are familiar with using Dynamic Link Manager on the earlier Adaptable
Modular Storage systems, then you will notice that both paths are listed as Owner
paths instead of one path listed as the Owner and the other path as Non-owner.
The earlier HDS modular system operated in an Active-Passive mode on the front
end host connections. The AMS2000 family utilizes the Active-Active host
connections.
3. Click the Options button to view what parameters are currently set.
See next page for resulting screen shot.
2. In the Topology panel, expand the icon for your Windows host system (WLABD
in the captured screen shot) and click on the Worker 1 icon
See next page for resulting screen shot.
The letter of the New Volumes listed (E:New Volume and F:New Volume) should
match the disk letter that was shown by the Disk Management utility (see page
10-2).
The drive letters that you are seeing may be different from the letters illustrated in
the lab project because of a different number of disks discovered by the Windows
Disk Management utility.
3. Holding the shift key depressed, check the box to the left of the two Target Disks
(remember, your disk letters may be different). Also, if your target disks have a
small red line over the icon, ignore the red line and select the disk.
4. Enter 10 in the # of Outstanding I/Os box (sets Command Tag Queuing to 10).
5. Click the Access Specifications tab.
6. From the Global Access Specifications panel, select the default entry and then
click the Edit button.
See next page for resulting screen shot.
This setting will cause 64KB records to be written Sequentially at a 75% Write, 25%
Read duty cycle.
8. Click the Add button.
9. Click on Worker 2 and then click the Disk Targets tab.
10. Check the two New Volume boxes (remember to hold the shift key).
11. Enter 10 in the # of Outstanding I/Os box (sets Command Tag Queuing to 10).
12. Click the Access Specifications tab.
13. Select the specification that you created earlier and then the Add button.
14. Repeat Steps 9 – 13 for Worker 3 and Worker 4.
15. In the upper row of the Iometer window, click the icon of the green flag to start
Iometer.
The results of the operation will be saved in the results file (you could choose the
folder, by default it goes into My Documents).
Note: While running Iometer, you may see a small message at the bottom of you
Windows screen indicating Low Disk Space. Just ignore the message.
16. Click the Save button to start the I/O process.
17. Bring the Dynamic Link Manger GUI to the front and click the Refresh button,
and continue to click Refresh to see the I/O flowing to both LUNs and on both
paths.
Also, it will take a few minutes to fill up the cache before you begin to see I/O
going down both paths.
See next page for a sample of what you should see.
By default, performance data will be collected from all seven functional areas.
4. Click OK to accept the default settings.
5. Click the Confirm button and then Close at the changed successfully prompt.
Note: The Get Performance function would allow you to configure a plan that
would collect the data a specified number of times over a defined period of time.
In class you will skip this function.
6. From the Arrays panel, expand Settings.
7. Select Advanced Settings and click the Open Advanced Settings button.
8. Click on Performance and then click the Display Graph button.
See next page for resulting screen shot.
9. In the subsystem panel, click on Logical Unit and then click the Start button and
OK to the Monitoring will be start prompt and wait: by default, the IO Rate of
LUN 0 will be displayed once a minute.
Also, you will not see anything in the graph area (a red dot) until the first timeout
at the end of 1 minute.
10. Wait and watch several cycles until you see some metrics for LUN 1 appear in the
small panel above the graph area. Select LUN 1 and click the Display Graph
button, and then select a lower Chart Y Axis Rate (say, 200).
11. In the Subsystem panel, expand CTL 1 and select Logical Unit, followed by
clicking the Display Graph button.
The system is load balancing across the controllers.
12. Experiment by selecting other subsystem areas. What you are currently
displaying is also controlled by the drop-down list above the Display Graph
button. As you move from one metric to another, remember to click the Display
Graph button to refresh the graph, and you may have to again adjust the Y Axis
setting.
13. When you are satisfied, click the Stop button and Close the Monitor.
14. Optional Step if your instructor has access to the Brocade switch. Have the
instructor disable one of the switch ports where your array is connected. Keep
refreshing the Dynamic Link Manger window to see the failover. After the port is
again enabled, the system should fail back.
15. Exit Dynamic Link Manger.
16. Logout of Storage Navigator Manager 2.
17. Click the Red Stop sign of Iometer to stop the I/O and close the window.
2. Assuming the configuration outlined in question 1, how many LUNs would the host
detect after the installation of Dynamic Link Manger?
3. Again, referring to the configuration of question 1, Dynamic Link Manger will display
all the configured (managed) paths.
A. TRUE
B. FALSE
4. By default, Dynamic Link Manger will attempt to Load Balance.
A. TRUE
B. FALSE
5. By default, Dynamic Link Manger is set for manual failback.
A. TRUE
B. FALSE
6. When using the Performance Monitor to collect performance metrics, front end
performance is affected.
A. TRUE
B. FALSE
7. How many individual performance metrics can be displayed in the Performance Graph
at any point in time?
8. The Performance Graph has to be stopped and then again started each time you select
another metric to display.
A. TRUE
B. FALSE
Lab 10 - End
Activity
First remove one of the trays from your assigned storage system, then replace it.
Anti-static Setup
1. Ask your instructor for an anti-static mat and wrist strap.
2. When you begin the handle actual system components, attach the metal clip (of
the mat) to a part of the unit frame where metal is exposed.
3. Attach the wrist strap to your wrist securely.
Lab 11 - End
Summary of Activities
1. Export of configuration information (Constitute files).
2. Collection of a Simple Trace.
3. Put SNM2 into Maintenance Mode.
4. Microcode/Firmware Update.
10. Check the Yes box and click OK to confirm the transfer and update process.
If you were not able to set the interval time to 0 seconds, then the operation will
take about 80 minutes.
Since you are in maintenance mode, the process will take about 40 minutes.
This ends the lab project. The class lecture will continue while the update takes
place.
When you return to your array you can close the completion window.
Lab 12 - End
Summary of Activities
1. Put SNM2 into Maintenance Mode.
2. Replacement of a Hard Drive
3. Replacement of a Control Unit on a Adaptable Modular Storage 2000
4. Replacement of a ENC Unit
5. Replacement of a Interface Board
6. Replacement of a SFP FC Host Connector
1. Because of the previous lab project, if open windows are present relative to the
microcode update, close all open windows and exit both the SNM2 window of the
SNM2 login window.
2. From your assigned classroom PC, use the Remote Desktop Connection Utility
and connect to your assigned management server in the lab.
3. Launch SNM2 and login as system giving the password manager.
4. Check the box to the left of your systems Array Name.
5. Issue the following keyboard keystroke sequence to put SNM2 into Maintenance
Mode: Ctrl-Shift-E.
7. Expand Settings and click Advanced Settings, and then click the Open Advanced
Settings button.
Notice that a Maintenance choice is now available.
8. Select Maintenance and then click the Set button.
8. Click Close.
9. Click the Event Log tab.
Collect Trace
1. Click the Collect Trace button.
2. Click Download.
3. Click Save.
See next page for resulting screen shot.
Save the file smpl_trc0.dat in any folder that you want, the default is the desktop.
After saving the file, you could edit the name to include the date and time.
4. Click Save and then the Close button after the process completes.
In an actual production environment you would upload the trace file to the
Hitachi Data Systems Global Support Center – Technical Upload Facility (TUF) at
the following URL:
https://tuf.hds.com/gsc/bin/view/Main/WebHome
See next page for resulting screen shot of what the TUF upload looks like.
In class you will not be performing the upload.
1. Once more, go to Advanced Settings, click the Maintenance link and then click
the Set button.
2. Select the Data Reconstruction radio button.
3. Enter the following to select the drive (remember, your Unit Number and HDU
Number may be different).
Unit No.: 01
HDU No.: 03
4. Click Apply and then OK to the resulting prompts.
5. Close the Maintenance window and then the Advanced Settings window.
6. In the Arrays panel, click on Alerts & Events and then click the Event Log tab.
7. Wait a few of minutes and click the Refresh Information button and then Close
at the completion prompt.
As you can see from the previous two screen shots, the reconstruction has
occurred and drive 01 14 is now be substituted for the failed drive.
1. Use the WEB tool to collect a Simple Trace before performing any action.
2. Fail the control unit by pushing the RST SW button to block the Control Unit you
want to change.
3. Open the right and left levers toward you at the same time while pressing the right
and left blue buttons.
4. Remove and label all the cables connect to the Control Unit.
5. Remove the Control Unit by pulling it out toward you.
6. Wait at least 20 seconds before inserting the replacement unit into the RK module,
but do not seat the controller (leave it out about 2 inches).
7. Connect all the removed cables to the replaced Control Unit.
8. Install (seat) the new Control Unit using the right and left levers, closing the
levers completely until the blue buttons click.
9. Make sure that the warning LED on the front of the chassis goes out.
10. Check that the Ready LED is on.
11. Check the information and error messages using the WEB Tool.
Note: If the new Control Unit is inserted without waiting for 20 seconds, it is
possible that the Control Unit is not recovered from the failure normally!
1. Use the WEB tool to collect a Simple Trace before performing any action.
2. Open the right and left levers toward you at the same time while pressing the right
and left blue buttons.
3. Remove the ENC cable connected to the ENC unit to be replaced.
4. Remove the ENC unit by pulling it out toward you.
5. After waiting for 20 seconds or more, insert a new ENC unit until its lever is
slightly opened. Do not insert the ENC unit completely!
6. Connect the ENC cable to the new ENC unit.
7. Close the lever completely until you hear the blue buttons click.
8. Make sure that the ALM LED on the ENC unit is off.
9. Check that the READY LED on front of the basic chassis is on and the “ALARM
LED” and the “WARNING LED” goes off.
10. Check the information and error messages on the WEB tool.
Note: If the new ENC unit is inserted without waiting for 20 seconds, it is possible
that the ENC unit is not recovered from the failure normally!
y To prevent part failures caused by static electrical charge built up on your own
body, be sure to wear a wrist strap connected to the chassis before starting and
do not take it off until you finish.
y Be sure to wear a wrist strap connected to the chassis whenever you unpack
parts from a case. Otherwise, the static electrical charge on your body may
damage the parts.
y When you install is Control Unit, support its metal part with your hand that has
the wrist strap. You can discharge static electricity by touching the metal plate.
See pages 13-16 and 13-17 for detailed illustrations showing component locations.
8. Place the new Interface Board according to the positioning pin of the Control Unit,
press the label “PUSH HERE” part, and insert the connector. At this time, check
that the connector is seated correctly. Insert the interface Board making its sheet
metal part face inside of the Control Unit.
Note: Install the new Interface Board in the removed position.
9. Fix the Interface Board by tightening the four fixing screws.
10. Install the removed FC Host Connectors.
11. Close the cover and fix it by fastening the two cover fixing screws on the top of
the cover.
12. Perform step 6–11 of the controller replacement procedure.
Model 2500
1. Remove the FC cables connected to the Control Unit mounting the FC Host
Connector to be replaced.
2. Remove the Host Connector. Pull out the Host Connector after raising the lever.
3. Make sure 20 seconds or longer has elapsed after the FC Host Connector was taken
out.
4. Check the insertion direction of the FC Host Connector.
5. Insert the FC Host Connector in the Port until it clicks.
6. Connect the FC cables.
7. Check that the port LED does light on and check the information and error
messages on the WEB tool.
Note: If the FC Host Connector is inserted before 20 seconds has elapsed, the FC
Host Connector may not be recovered normally.
Lab 13 - End
Activity
1. From the classroom PC, use the Remote Desktop Connection Utility and connect
to your assigned Windows server in the lab.
2. Connect to your assigned storage array using the Internet Explorer browser.
3. Go to the rear of your system.
4. Locate the two Soft Reset switches (one button per control unit).
5. Use a non-conducting probe and push the soft reset switch, marked RST SW, on
CTL 0: the yellow light will come on as you depress the switch.
6. Within 3 - 5 seconds push the RST SW switch on CTL 1.
7. Refresh the web browser (the F5 key) and you should get the logon screen.
In this situation the host has no access to the disks and you can alter many of the
system configuration settings. Notice the Go to Normal Mode buttons. These will
cause a reboot of the subsystem and put it back online, retaining any changes you
may have made.
While in Maintenance Mode, you may change any number of system settings by
clicking on the menu links shown on the left side of the page.
System Parameters
Before flashing the microcode, the lab project will guide you through a quick tour of
displaying system parameters, but this is just a tour, so do not make any changes.
3. Select Single Mode from the System Startup Attribute, and then reselect Dual
Active Mode.
At this time do not make any changes but view what can be done. An explanation of
each of these parameters can be found in the Maintenance Manual.
IF you were making changes, you would click Set to commit any changes, and then
respond to the resulting prompts. A system restart would be performed.
Next, you are guided through some of the other functions. Examine the resulting
screens, but only make and save changes if you are instructed.
Host Interface
1. In the left panel, click the Host Interface link.
Network
1. In the left panel, click the Network (IPv4) link.
Name
1. In the left panel, click the Name link.
Initialize
The Initialize function sets the system parameter information of the device to a
known initial state. This would typically be carried out during an initial build of a
system prior to the first microcode install.
If you executed this function, it causes a restart of the system.
Microprogram Initial Setup
1. In the left panel, click on Microprogram.
Note: This error occurs when the correct Java Policy is not in effect.
The following steps will have you correct the problem and the process
assumes that JRE 1.6.0 or higher is installed.
2. Drill to the following folder of your management server:
C:\<path to the firmware>\DF800 code load
10. Select the folder which name reflects the version of the firmware you use and then
click the Open button.
See next page for screen shot.
11. Click the Install button and wait for the following prompt to appear (can take a
couple of minutes).
13. Check the OK to execute check box and then click OK.
17. Click OK and wait for about 60 seconds, then click the browser refresh button.
18. Wait a few more minutes and refresh your screen again. The system should again
be in the Ready state.
19. Close the browser.
2. What are the strings used to put the web browser into Maintenance Mode:
User Name:
Password:
3. The Initial Setup function allows you to load a lower or higher version of microcode
while preserving the current configuration.
A. TRUE
B. FALSE
Lab 14 - End