APL CONCRETE
Chenganatham Road,Rangapuram,
UNIT 1
Vellore - 9
TEST REPORT ON CONCRETE CUBES
sge
NAME OF CUSTOMER OSTAL INDIA PVT AUTOMOTIVE UNIT
LOCATION SIPCOT INDUSTRIAL ESTATE ,RANIPET
LOCATION 1D RANIPET
GRADE M30
INO. OF CUBES TAKEN £06
|IDENTIFICATION MARK TRAIL MIX CUBES: .
DETAILS OF COMPRESSIVE STRENGTH
Date of Dateot | AgeatTest | Weight | Density | Failure [Compressive] Average
Casting Testing (Gays) of Cube in Load | Strength | Strength
(Ka) koi” | gy | (im? | (Nim
3534 __| 2528.593| 480 21.33
2tvJan-19 | 24-Jan-19 3 8.106 | 2401.778| 460 20.48 21.93,
8.366 | 2478.815| 500 22.22
INote:
= Concrete cubes are cured in water & tested as per IS:516:1959 (Reaffirmed 2008)
/* Size of the specimen 150 mm x 150 mm x 160 mm
*Storeage, Curing and Testing Carried out accourding to the relavant indian standards unless otherwise
Stated
Mass and Density are saturated at test unless code 20 is reported,
/+Nethod of Determining volume is apparent unless code 21 and 22 reported
Comments Codes
1, Cube Oversize 1 face 11, Sceince of Frost attack 24, Density By Displacement
12. Cube Oversize 2 faces 412, Xposed Aggregate 22. Conerete Sandy
3. Cube Oversize 3 faces. 18, Concrete Stoney
|4. Rough Edges 414, Normal Mode of Failure
6. Density By Displacement 16, Condition at Test Moist
6. Chpped Comers 16, Certificates of Slumping Not Available
7. Poor Compaction 47. Density By Volumeatric Calculation
Ja. Cube Honeycombed 18. Mass and Density as Received
Jo. Concrete Vareibie 419, Fines Removed By Carborundum Stone
H10, Cubes Retaned 20, Abnormal Mode of failure
‘Acknowledgement ‘APL Concrete
Manager-Technical