Oxygen Sensors

Line Guide
Breathe easier, with unparalleled reliability. Honeywell gas, providing enhanced accuracy and durability. That’s why
Sensing and Control (S&C) offers a comprehensive range of Honeywell S&C sensors are commonly found in potential
oxygen sensors unmatched in the industry. Simply stated, our applications from industrial processes, agriculture, and on-board
sensors are engineered to perform better and last longer. Our aircraft oxygen generation system controls to automotive exhaust
design employs two Zirconium Dioxide (ZrO2) discs with a gas diagnostics, service instruments, environmental oxygen
small, hermetically sealed chamber between each disc. ZrO2 monitoring, combustion systems, and environmental controls.
technology provides oxygen measurement without reference

FEATURES
OXYGEN SENSORs KGZ-12 Series. wide measuring range • Low power
KGZ-10 Series. Features: Long sensor probe, enhanced consumption • No reference gas
Features: Small, enhanced accuracy, accuracy, wide measuring range • Low necessary • Linear output signal
wide measuring range • Low power power consumption • No reference gas • No need for temperature stabilization
consumption • No reference gas necessary • Stainless steel construction, • Function testing and calibration in
necessary • Stainless steel construction, both externally and internally • Resistant ambient air • Rugged construction • Easy
both externally and internally • Often to vibration, moisture, and high pressures calibration • Enhanced life
resistant against vibration, moisture and • Failsafe measuring principle • Linear
Benefits: Dynamic sensing principle
high pressures • Fail safe measuring output signal • No need for temperature
allowing failsafe operation. Electronics
principle • Linear output signal • No need stabilization • Function testing and
necessary to operate the sensor can
for temperature stabilization • Function calibration in ambient air • Easy
be incorporated into the customer’s
testing and calibration in ambient air calibration • Enhanced life
own electronic circuits or be purchased
• Rugged construction • Easy calibration
Benefits: Dynamic sensing principle as a separate interface board. Can be
• Long life
allowing failsafe operation. Electronics used directly in high temperature, high
Benefits: Dynamic sensing principle necessary to operate the sensor can be pressure, and polluted gases. Often
allowing failsafe operation. Electronics incorporated into the customer’s own ideal for potential applications including
necessary to operate the sensor can electronic circuits or be purchased as a heating boiler control, industrial process
either be incorporated into the customer’s separate interface board. High resistance control, control of aircraft on-board oxygen
own electronic circuits or be purchased to corrosion allows the sensor to be used generation systems, automotive exhaust
as a separate interface board (DE800, in aggressive, harsh environments. Can gas diagnostics, service instruments, and
Oxymac50 or ELECDITT). High resistance be used directly in high temperature, monitoring environmental oxygen.
to corrosion allows the sensor to be used high pressure, and polluted gases. Often
in aggressive, harsh environments. Can ideal for potential applications including MF010 Series.
be used directly in high temperature, heating boiler control, industrial process Features: Combines an oxygen sensor
high pressure, and polluted gases. Often control, control of aircraft on-board oxygen probe with electronics mounted at the
ideal for potential applications including generation systems, automotive exhaust back of the probe electromechanical
heating boiler control, industrial process gas diagnostics, service instruments, pump • No moving parts • IP65 • No
control, control of aircraft on-board oxygen monitoring environmental oxygen, reference gas necessary • Stainless steel
generation systems, automotive exhaust agriculture, composting, and fruit storage. construction, both externally and internally
gas diagnostics, service instruments, • Resistant to vibration, moisture, and high
monitoring environmental oxygen, GMS-10 Series. pressures • Failsafe measuring principle
agriculture, composting, and fruit storage. Features: Small, enhanced accuracy, continued on page 4
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Oxygen Sensors Line Guide

Oxygen Sensors
Uncommon sensing. KGZ-10 Series KGZ-12 Series GMS-10 Series
Unmatched leadership.
Honeywell S&C’s dual disc,
Sensor voltage levels
Zirconium Dioxide (ZrO2) 45-64-85 mV 45-64-85 mV 45-64-85 mV
(recommended)
design offers advantages over
Pump current
the competition — because 40 uA 40 uA 40 uA
(recommended)
it’s built for enhanced accu- 80 mm probe; screw
racy. The first disc functions 400 mm probe; 220
Housing flange mounted fit probe (28 mm, 45
mm probe
as a reversible oxygen pump, mm, 55 mm)
which sequentially fills and Response time <4s < 15 s < 15 s
empties the chamber. The Warm up time < 100 s < 100 s < 100 s
second disc measures the Heater supply 4.35 V (1.85 A) 4.0 V (1.7 A) 4.0 V (1.7 A)
ratio of the partial pressure dif-
Oxygen pressure range 2 mbar - 3 bar 2 mbar - 3 bar 2 mbar - 3 bar
ference, and then generates a
Operational temperature 700 °C [1292 °F] 700 °C [1292 °F] 700 °C [1292 °F]
corresponding voltage. A heat
element produces the 700 °C Sensitivity 1.05 ms/mbar 1.05 ms/mbar 1.05 ms/mbar
[1292 °F] required for the ZrO2 Accuracy < 5 mbar < 5 mbar < 5 mbar
to operate as an O2 pump. The 0,6 mm [0.024 in] diameter, 4-pin, nickel-
time needed for the pump to plated steel; 4,0 mm x 8,0 mm x 7,00 mm 5 Teflon coated wires
Termination [0.157 in x 0.315 in x 0.028 in] Faston 5 Teflon coated wires (with 6 fold Molex
reach specific minimum and
contact tabs; 0,6 mm [0.024 in] diameter, connectors)
maximum pressures within the 5-pin, nickel-plated steel
chamber provides a measure
of the partial oxygen pressure
of the environment.

Trust Honeywell S&C for top- Oxygen Sensors


flight engineering, and world-
MF010 Series
class performance: enhanced
accuracy measurement;
low power consumption; no Supply voltage 24 Vdc ±5 %
reference gas or temperature Supply current 500 mA
stabilization required; linear Output signal 0 Vdc to 10 Vdc or 4 mA to 20 mA
output signal; function testing Housing 220 mm probe; 400 mm probe; 600 mm probe
and calibration in ambient air; Oxygen concentration range 0.1 % to 25 % (0 % to 100 % on request) by volume
and enhanced life.
Ambient temperature -10 °C to 50 °C [14 °F to 122 °F]
Permissable gas temperature
-148 °C to 482 °C or -148 °C to 752 °C
(probe tip)
Resolution 12 bit
Sensitivity 1.05 ms/mbar
Accuracy ±2 %
Termination binder connector, 693 series
Repeatability ± 1%
Warm up time 10 min. (approx.)
2 www.honeywell.com/sensing
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Oxygen Sensor
Interface Boards
Oxymac50 Elecdit DE800

Supply voltage 24 Vdc ±20 % 15 Vdc ±10 % 24 Vdc ±20 %


Supply current 100 mA 100 mA 100 mA
Power consumption (interface) <250 mW <250 mW <500 mW
0 Vdc to 10 Vdc or 0 Vdc to 10 Vdc or
Output signal 0 Vdc to 10 Vdc
4 mA to 20 mA 4 mA to 20 mA
0.1 % to 25 % 0.1 % to 25 % 0.1 % to 25 %
Oxygen concentration range
(0 % to 100 % on request) by volume (0 % to 100 % on request) by volume (0 % to 100 % on request) by volume
-10 °C to 50 °C -10 °C to 50 °C -10 °C to 50 °C
Ambient temperature
[14 °F to 122 °F] [14 °F to 122 °F] [14 °F to 122 °F]
Resolution 12 bit 12 bit 12 bit
Sensitivity 1.05 ms/mbar 1.05 ms/mbar 1.05 ms/mbar
Accuracy ±2 % ±2 % ±2 %
Repeatability ± 1% ± 1% ± 1%
2,5 mm x 2,5 mm
Connector 15-pin D type connector (0.1 in x 0.1 in) screw connector block
pin connector

www.honeywell.com/sensing 3
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
• Low power consumption • No need for ambient air • PCB board format • Linear details. If warranted goods are returned to
temperature stabilization • Functional output of measured oxygen content in Honeywell during the period of coverage,
testing and calibration in ambient air voltage or current format • Requires an Honeywell will repair or replace, at its
• Suitable for use in gases up to 300 °C external heater power supply • Low power option, without charge those items it finds
[572 °F] • Lower running costs consumption • Flexible interconnection defective. The foregoing is buyer’s sole
• Enhanced life • Lower running costs remedy and is in lieu of all warranties,
expressed or implied, including those
Benefits: No reference gas pressure Benefits: Removes the need to implement
of merchantability and fitness for a
required, creating an ability to measure sensor control circuits within equipment.
particular purpose. In no event shall
ambient oxygen content. Can be operated Removes effects of barometric or
Honeywell be liable for consequential,
by simple, low-cost electronics. Allows application pressure changes and sensor
special, or indirect damages.
failsafe operation. Can be mounted drift for enhanced accuracy. Offers a level
directly into the flue. High resistance to of noise protection. Ease of mounting While we provide application assistance
corrosion allows the sensor to be used and access for calibration. Potential personally, through our literature and
in aggressive, harsh environments. No applications include heating boiler control, the Honeywell web site, it is up to the
additional electronic circuit needed. industrial process control, combustion customer to determine the suitability of the
Potential applications include heating systems, compost systems, environmental product in the application.
boiler control, industrial process control, control, medical, and aerospace. Specifications may change without notice.
combustion systems, compost systems, The information we supply is believed to
and environmental control. DE800. be accurate and reliable as of this printing.
Features: Provides the necessary circuits However, we assume no responsibility for
OXYGEN SENSOR INTERFACE to control Honeywell oxygen sensors its use.
BOARDS – KGZ SERIES • Functional testing and calibration in For more information about Sensing and
Oxymac50. ambient air • PCB board format • Linear Control products, visit www.honeywell.
Features: Provides the necessary circuits output of measured oxygen content in com/sensing or call +1-815-235-6847
to control Honeywell oxygen sensors voltage or current format • Requires no
Email inquiries to info.sc@honeywell.com
• Functional testing and calibration in external heater power supply • Low power
ambient air • PCB board format • Linear consumption • Flexible interconnection WARNING
output of measured oxygen content in • Lower running costs PERSONAL INJURY
voltage or current format • Requires an
Benefits: Removes the need to implement • DO NOT USE these products as
external heater power supply • Low power
sensor control circuits within equipment. safety or emergency stop devices
consumption • Flexible interconnection or in any other application where
Removes effects of barometric or
• Lower running costs failure of the product could result in
application pressure changes and sensor
personal injury.
Benefits: Removes the need to implement drift for best accuracy. Ease of mounting
sensor control circuits within equipment. and access for calibration. Potential Failure to comply with these
Removes effects of barometric or application applications include heating boiler control, instructions could result in death or
serious injury.
pressure changes and sensor drift for industrial process control, combustion
enhanced accuracy. Ease of mounting and systems, compost systems, environmental
access for calibration. Potential applications control, medical, and aerospace. WARNING
include heating boiler control, industrial MISUSE OF DOCUMENTATION
process control, combustion systems, Warranty. Honeywell warrants goods of • The information presented in this
compost systems, environmental control, its manufacture as being free of defective catalogue is for reference only. DO
medical, and aerospace. materials and faulty workmanship. NOT USE this document as product
Honeywell’s standard product warranty installation information.
Elecdit. applies unless agreed to otherwise by • Complete installation, operation and
maintenance information is provided
Features: Provides the necessary circuits Honeywell in writing; please refer to your
in the instructions supplied with each
to control Honeywell oxygen sensors order acknowledgement or consult your
product.
• Functional testing and calibration in local sales office for specific warranty
Failure to comply with these
Sensing and Control instructions could result in death or
Automation and Control Solutions serious injury.
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422 USA
000674-1-EN IL50 GLO 
+1-815-235-6847 June 2008
Copyright © 2008 Honeywell International Inc. All rights reserved.
www.honeywell.com/sensing