You are on page 1of 14

Plans for villa:

First floor:
Second floor:
Catalog of radiator:

From radiator 2000 co.

The type we will choose:

Model h b i p Q/Section
800 881 80 800 95 87.2
Radiator design:

Before insulation:

Max.lenght(m) EL1(m) L2 EL2(m) L3 EL3(m)


8.6 10.32 3 4.5 3 4.5
max Qr(Kw) 3.30997
Cpw 4.186
ꙘT 10
Mr(L/s) 0.079072
velocity(m/s) 0.9
ꙘP/EL1(Pa/m) 850
ꙘP1(Pa) 8772
D (mm) 15
D2(mm) 20
D3(mm) 25
Qfirst 7.520175
Mfirst 0.179651
ꙘP/EL2(Pa/m) 870
ꙘP2(Pa) 3915
Mboiler 0.355658
ꙘP/EL3(Pa/m) 610
ꙘP3(Pa) 2745
ꙘP pump(Pa) 15432
Mpump 0.355658
Selected Pump VA
Radiator distribution:

Note: Red color for supply water, blue color for return water.

Before insulation:

First floor:
Second floor:
Length of pipes for each radiator:

Radiator # Supply Length Return Length


1 8.6 5.5
2 8.55 8
3 3.85 6.6
4 4.45 5.5
5 4.45 5.45
6 6.1 7.55
7 7.2 8.6
8 6.9 7.1
9 4.15 6.85
10 4.45 5.5
11 5.45 6.35
12 8.4 7.3
Max length = 8.6m.
After insulation:

First floor:
Second floor:

Length of pipes for each radiator:

Radiator # Supply Length Return Length


1 8.1 5.85
2 8.7 8.2
3 4.25 5.8
4 4.7 5.4
5 5.9 7
6 7.4 8.6
7 7 7.3
8 5 6.85
9 4.7 5.4
10 5.95 6.15
11 8.25 7.4
CHOSEN PUMP:

VA TYPE OF VA 25/130, Q=30L/MIN.


Selection of boiler:

Use Inovia cond plus 25S


Selection of chimney: