You are on page 1of 1

PT.

SISPUM SARANA GRAHA

TOOL AND EQUIPMENT INSPECTION

SLING INSPECTION FORM


Inspector Subcontractor Work Team Inspect. Date Color Code Remarks
of
Number of Inspected Accepted Rejected The Month
Wire Sling
Web Sling

Result column: (  ) Yes/Good, Acceptable, ( X ) Not/Bad, Not to use, ( NA ) Not applicable

No Check Item Sling No.


1 2 3 4 5 6 7 8

1 Wire Sling (Size)


Location or User
a Reduction of Dia. ≧7%
b Damage of Strands≧10%
c Kink or Deformed
d Corroded

Judgment
2 Web Sling (Dimension)
Location or User
a Abrasion, Cut or Burnt
b Cut of Seam or Peeled
c Napped to seam

Judgment
 When one crack of web sling is over 10% in width, or 25% in thickness, or 5 or more
cracks are over 3% in width or 1% in thickness, The Web sling shall be rejected.
PT. SISPUM SARANA GRAHA
Inspected by Date : Name : Signature :
Position :
Approved by Date : Name : Signature :
Position :

Approved by Date : Name : Signature :


Position :