Professional Documents
Culture Documents
Engine
ECM
Main pump Pilot pump
Pump power
shift EPPR
CAN
Cluster
Drive signal
MCU
Normal
CN-16B
Emergency
21095MS02
Mode selection system (micro computer based electro-hydraulic pump and engine mutual control
system) optimizes the engine and pump performance.
The combination of 3 power modes (P, S, E) and accel dial position (10 set) makes it possible to use
the engine and pump power more effectively corresponding to the work conditions from a heavy and
great power requesting work to a light and precise work.
P Heavy duty power 1950Ü50 1900Ü50 1950Ü50 1900Ü50 185Ü30 2.5 160Ü30 0
S Standard power 1750Ü50 1700Ü50 1850Ü50 1800Ü50 290Ü30 8Ü3 290Ü30 8Ü3
E Economy operation 1600Ü50 1700Ü50 1700Ü50 1800Ü50 365Ü30 13Ü3 365Ü30 13Ü3
AUTO Engine
1000Ü100 - 1000Ü100 - 700Ü30 35Ü3 700Ü30 35Ü3
DECEL deceleration
One touch Engine quick
850Ü100 - 850Ü100 - 700Ü30 35Ü3 700Ü30 35Ü3
decel deceleration
KEY Key switch
850Ü100 - 850Ü100 - 700Ü30 35Ü3 700Ü30 35Ü3
START start position
※ Power shift (Standard/Option) can be changed by "Service menu" in "Management" on the cluster.
5-3
2. WORK MODE SELECTION SYSTEM
Work mode consists of the general operation (bucket) and the optional attachment (breaker,
crusher).
Attachment pilot
pressure sensor
Main control valve
Work tool
Arm 1 Arm 2
SOLENOID VALVE
Option Bucket
Attachment
pressure
Boom 2 Boom 1
Attachment
Swing Travel(LH) conflux
Travel(RH) Attachment
safety
Engine
ECM
Main pump Pilot pump
Pump power
shift EPPR
CAN
Cluster
Drive signal
Drive signal
MCU
Pressure signal
Normal
CN-16B
Emergency
Work mode
pilot lamp Work mode switch signal Accel dial
21095MS03
5-4
3. USER MODE SELECTION SYSTEM
Engine
ECM
Main pump Pilot pump
Pump power
shift EPPR
CAN
Cluster
Drive signal
MCU
Normal
CN-16B
Emergency
21095MS03A
1) High idle rpm, auto idle rpm and EPPR pressure can be adjusted and memorized in the U-mode.
2) LCD segment vs parameter setting
Step Engine speed Idle speed Power shift
( ) (rpm) (rpm) (bar)
1 1500 700 0
2 1550 750 2
3 1600 800 4
4 1650 850 (low idle) 7
5 1700 900 12
6 1750 950 15
7 1800 1000 (decel rpm) 20
8 1850 1050 24
9 1900 1100 28
10 1950 1150 33
5-5