Loads and bolting
H = 0.785 G²p = HG = 6.28bGmp =
Wm1 = HG + H = Wm2 = 3.14bGy =
Am1 = Wm1/Sb = Am2 = Wm2/Sa =
Am = max. (Am1, Am2) =
Ab = number of bolts x root area =
W = (Ab + Am) Sa/2 =
Moment arms and moments
HD = 0.785B²p = hD = (C - B)/2 =
HG = hG = (C - G)/2 =
HT = H - H D = hT = (2C - B - G)/4
HDhD
HGhG
HThT
MOP = Matm = WhG =
Loose method criteria
16 mm > gO = 300 > B/gO =
2 N/mm² > p = 370°C > design temperature
Shape constants
ho = √BgO = h/hO =
K = A/B = g1/gO =
T= F=
Z= V=
Y= f=
U= e = F/hO =
d = (U/V)hOgO² =
bolt spacing
CF = √ (2xbolt outside diameter) + 6t/(m+0.5)
Assumed t =
β = 1.333te + 1 =
λ = (te +1)/T + t³/d =
Stress calculation
Moment M = MOP CF √B or Matm CF√B (CF ≥ 1)
For operating condition For bolting - up condition
SH = fM/(λg1² ) = =
SR = βM/(λt² ) = =
ST = MY/t² - ZSR = =
0.5 [SH + max. (SR, ST)] = =
(loose option) YM/t² = =
Conclusion :