Professional Documents
Culture Documents
USER MANUAL
Contents
Complete set 01
Products Parts 02
Technical Specification 03
Operational Method 05
Interface Introduction 06
Tips 09
Safety Precautions 10
Knowledge of equipment
Antennae
Device host
01
Knowledge of equipment
Products Parts
1
6
7
8
9
11
10
12
13 14 15
02
Knowledge of equipment
Technical Specification
Frequency Counter mode :
Resolution: 10 KHz (Digital signal ) 1 KHz ( Analog signal )
Impedance: 50 Ohms ( MCX connector )
Frequency range: 10 MHz - 3 GHz
Sensitivity: -35 dBm Maximum input: 15 dBm
Frequency range:
U.S. BANDS: LTE 700 CDMA 800 GSM1900 CDMA2000 LTE2300 WIFI 2400
EURASIAN BANDS: LTE 800 GSM900 GSM1800 WCDMA2000 LTE2600 WIFI 2400
03
Knowledge of equipment
4. Designed with 20 sectors of Ultra sensitive synchronous RF signal by LCD Signal strength display.
Sounding, Lighting ,Viberating and Silent Alarming Optional.
5. Squelch adjustment
04
Method of use equipment
Operational Method
How to Connect the antennae
Connect the antenna to the interface after opening the Packing box
2. MultiPurpose Button
· Long Press the button for 2 seconds to change the working mode
·
The measurement frequency range can be changed by moving up or
down button through the multipurpose button under frequency
Counter Mode,and then click the multipurpose button to enter into the
measurement model. Frequency Range with 500Mhz and 3000Mhz
Optional. Less than 500Mhz signals measurement,please choose
RANGE 500MHZ,Less than 3000Mhz signals frequency measurement,
please move the switch to RANGE 3000MHZ.
· Under Cellphone Mode, the sensitivity (high, medium and low) can
be adjusted by up or down the multipurpose button. This mode is
used for detecting all the cellphone signals,including cellphone,3G
and 4G LTE signals in local.
·
Wide band mode.With 20 signal strength display.Moving up the
mulitipurpose buttons up or down to adjust the sensitivity .
· Press the multipurpose button to the left or the right to select the
vibrating,sounding, lighting and mute alarming display.
05
Method of use equipment
Interface Introduction
Frequency Counter Mode
4
1 6
7
2
1 6
· Press the multifunction key left or right can change the vibration,
sound and light and mute warning display( the default is muted
warning)
· You should adjust test sensitivity base on need to test the phone
bands, mobile phone standard display bar indicates the strength of
the different signals
07
Method of use equipment
5
1
08
Method of use equipment
Tips
1. Battery: HS-C3000 Plus is with the built-in rechargeable
lithium-ion battery,lasting working for 3 hours if fully charged
battery; Please use the supplied charging adapter if charging.
Full charged time is around 2 hours . In order to prolong the
battery life and avoid affecting the memory, please recharge after
battery runs out .The backup battery is suggested.
2. Signal input: The received signal must not exceed the allowed signal
strength! Must be complied with the technical index strictly
(Received signal strength range is -35~0dBm).Frequency
Counter is designed with the signal bars to regulate the
distance between the measured equipment and frequency counter
antenna. It is more appropriate that the signal bars on the device is
near full.
4. Testing distance:It is optimum that LCD signal bars near full level
once Frequency Counter receives one type of signal. Generally, the
distance between car keys/remote control and frequency counter
antenna can be zero. While the distance between cell phone and
Frequency Counter is 0.1CM.For distance of Radio /Walkie Talkie
away from the Frequency Counter Antennae is around100CM.
09
Safety Precautions
Safety Precautions
Please read the following safety precautions carefully before operation:
Please turn off the device immediately and remove the power cord from
the power outlet if the following occurs.
· Electricity cut or unstable voltage .
· Machine emits unusual sound or smell.
· AC power cord is damaged.
· Equipment is damaged by dropping or hitting.
· Any liquid or objects have fallen within the enclosure.
Warning
10