6.

Dimensions
The dual nameplate shows the correct
Locknut 13 A/F Directional valve side orientation for each function

SWISS MADE

SRDB -- ABA -- 6 -- 1

40
METER--OUT FUNCTION

1,3
25,1
SRDB -- ABZ -- 6 -- 1

max.
29 96
Supplied complete with 24 A/F
Adjuster screw Tightening torque
4 A/F hex. socket seal plate and 4 O--rings
Ma = 46...54 Nm
Directional valve side

SWISS MADE

SRDB -- ABZ -- 6 -- 1

40
METER--IN FUNCTION
1,3
16,2
SRDB -- ABA -- 6 -- 1

max.
29 96

26,7 40,4
ISO 4401 size 3 interface
max.41
7,5

T
23

A B

ø 28
31

46

ø 5,3

Option:
SRD..--BA--6 ... / SRD..--BZ--6 ... Adjuster style H
SRD..--AA--6 ... / SRD..--AZ--6 ... Handknob
SRD..--ABA--6 ... / SRD..--ABZ--6 ...

7. Schematic section
1 Seal kit no. DS--202, comprising *):
Itm. Qty. Qty. Description Size
1 2*) 1 O--ring no. 017 ∅ 17.17 x 1.78 N90
2 2*) 1 O--ring no. 108 ∅ 6.02 x 2.62 N90
3 4*) 4 O--ring no. 012 ∅ 9.25 x 1.78 N90
4 2*) 1 Backup ring ∅ 10/6.7 x 1
SRD..-- AA/BA-- 6 / SRD..-- AZ/BZ-- 6
SRD..-- ABA-- 6 / SRD..-- ABZ-- 6

4 2 3

8. Installation and servicing


All installation and servicing must be produce the required metering func- seals, the new seals should by thor-
carried out with care, and by qualified tion. Use the specified tightening oughly oiled or greased before they are
personnel only. At Installation, be sure torque for the guide nut. When changin fitted.
to mount the valve the correct way up to