You are on page 1of 12

COMBINED FOOTING DESIGN 0

fck = 25 N/mm^2
fy = 500 N/mm^2
REBAR SIZE IN A = 16 mm
REBAR SIZE IN B = 16 mm
BEARING CAPACITY OF THE SOIL (qu) = 200 KN/m^2
CLEAR COVER FOR THE FOOTING = 70 mm

2
3

6
7

8
950

500

950

Design Of Combined Footing F3-F3


LENGTH AND WIDTH OF THE FOOTING
CG OF LOADS FROM PROPERTY LINE (X) = 3.128 m
LENGTH OF THE FOOTING = 6.300 m
ASSUMING WEIGHT OF FOOTING AND EARTH ABOVE IT AS 5% OF TOTAL WEIGHT,
TOTAL LOAD ON EARTH = 1919.6937 KN
HENCE WIDTH OF FOOTING = 1.524 m

ADOPT THE WIDTH OF THE FOOTING = 2.4 m

LONGITUDINAL BENDING MOMENT AND SHEAR


FACTORED LOAD ON COLUMN A = 1459.15 KN
FACTORED LOAD ON COLUMN B = 1420.39 KN
NET UPWARD SOIL PRESSURE = 190.00 KN/m^2
NET UPWARD SOIL PRESSURE PER UNIT LENGTH = 456.00 KN/m
MAX SHEAR FORCE AT CENTER LINE OF COLUMN A (V1)= -684.00 KN
MAX SHEAR FORCE AT CENTER LINE OF COLUMN A (V2)= 775.15 KN
MAX SHEAR FORCE AT CENTER LINE OF COLUMN B (V1)= 684.00 KN
MAX SHEAR FORCE AT CENTER LINE OF COLUMN B (V2)= -736.39 KN
POINT OF ZERO SHEAR FORCE FROM CENTER OF COLUMN A (x)= 1.69 m
MAXIMUM BENDING MOMENT FROM LEFT SIDE = -145.8289 KN-m
MAXIMUM BENDING MOMENT FROM RIGHT SIDE = -81.577 KN-m
HENCE MAXIMUM BENDING MOMENT = 145.82887 KN-m
DEPTH OF THE FOOTING REQUIRED (d) = 132.7109 mm

ADOPT THE OVERALL DEPTH OF THE FOOTING = 600 mm


EFFECTIVE DEPTH OF THE FOOTING = 530 mm
MAIN NEGATIVE LONGITUDINAL REINFORCEMENT @ TOP
AREA OF STEEL REQUIRED (Ast) = 639.26779 mm^2
ADOPT THE REBAR SIZE 16 mm
ADOPT THE SPACING OF REBARS = 200 mm
NO. OF REBARS REQUIRED = 12 NOS
AREA OF STEEL PROVIDED (Ast) = 2412.7432 mm^2
CHECK FOR PROVIDED STEEL OK
DEVELOPMENT LENGTH FOR THE ADOPTED BARS = 896 mm

MAIN POSITIVE LONGITUDINAL REINFORCEMENT @ BOTTOM


BENDING MOMENT AT FACE OF COLUMN A = 356.25 KN-m
BENDING MOMENT AT FACE OF COLUMN B = 356.25 KN-m
MAXIMUM BENDING MOMENT = 356.25 KN-m
AREA OF STEEL REQUIRED (Ast) = 1585.5167 mm^2
ADOPT THE REBAR SIZE 16 mm
ADOPT THE SPACING OF REBARS = 200 mm
NO. OF REBARS REQUIRED = 12 NOS
AREA OF STEEL PROVIDED (Ast) = 2412.7432 mm^2
MINIMUM AREA OF STEEL REQUIRED (Ast min) = 1728 mm^2
CHECK FOR PROVIDED STEEL OK
DEVELOPMENT LENGTH FOR THE ADOPTED BARS = 896 mm

ONE WAY SHEAR CHECK


PERCENTAGE OF TENSILE STEEL PROVIDED (p)= 0.19 %
FOR COLUMN A
SHEAR FORCE (Vu) = 419.47 KN
NOMINAL SHEAR STRESS (τv) = 0.330 N/mm^2
SHEAR STRENGTH OF CONCRETE (τc) = 0.33 N/mm^2
CHECK FOR ONE WAY SHEAR SAFE
FOR COLUMN B
SHEAR FORCE (Vu) = 380.71 KN
NOMINAL SHEAR STRESS (τv) = 0.299 N/mm^2
SHEAR STRENGTH OF CONCRETE (τc) = 0.33 N/mm^2
CHECK FOR ONE WAY SHEAR SAFE

TWO WAY SHEAR CHECK


FOR COLUMN A
SHORT SIDE / LONG SIDE (βc) = 1
ks = 1
τc = 1.25 N/mm^2
τc' = 1.25 N/mm^2
SHEAR FORCE (Vu) = 1257.58 KN
NOMINAL SHEAR STRESS (τv) = 0.576 N/mm^2
CHECK FOR TWO WAY SHEAR SAFE
FOR COLUMN B
SHORT SIDE / LONG SIDE (βc) = 1
ks = 1
τc = 1.25 N/mm^2
τc' = 1.25 N/mm^2
SHEAR FORCE (Vu) = 1218.82 KN
NOMINAL SHEAR STRESS (τv) = 0.558 N/mm^2
CHECK FOR TWO WAY SHEAR SAFE

TRANSVERSE REINFORCEMENT
Effective Depth,d= 514 mm
Factored Upwared Pressure under column A = 608 kN/m
BM at the face of column A= 274.35137 kNm
Width of strip from Left face Under Column A= 2264 mm
Area of tension steel, At 1254.6987 mm^2
ADOPT THE REBAR SIZE 16 mm
ADOPT THE SPACING OF REBARS = 200 mm
NO. OF REBARS REQUIRED = 11 NOS
AREA OF STEEL PROVIDED (Ast) = 2211.6812 mm^2

Factored Upwared Pressure under column B = 592 kN/m


BM at the face of column B= 267.06224 kNm
Width of strip from Left face Under Column B= 1528 mm
Area of tension steel, At 1233.7893 mm^2
ADOPT THE REBAR SIZE 16 mm
ADOPT THE SPACING OF REBARS = 200 mm
NO. OF REBARS REQUIRED = 8 NOS
AREA OF STEEL PROVIDED (Ast) = 1608.4954 mm^2

TEMPERATURE REINFORCEMENT PROVISION


MINIMUM AREA OF STEEL REQUIRED (Ast min) = 1728 mm^2
ADOPT THE REBAR SIZE 16 mm
ADOPT THE SPACING OF REBARS = 200 mm
NO. OF REBARS REQUIRED = 12 NOS
AREA OF STEEL PROVIDED (Ast) = 2412.7432 mm^2
CHECK FOR PROVIDED STEEL
KN KN 950
PA = 972.7694 PB = 946.9243

COL. COL. 500


A B

500 500
950

1500 3300 1500


Interpolation % Tc
Upper value 0.25 0.36
Required value 0.19 0.33
Lower value 0.50 0.48
OK

OK

OK
Combined Footing Summary Sheet

LONGITUDINAL TRANSVERSE
Footing ID L B D
BAR DIA. SPACING BAR DIA. SPACING
CF2 6.3 2.4 600 16 200 16 200
Combined Footing Summary Sheet

LONGITUDINAL TRANSVERSE
Footing ID L B D
BAR DIA. SPACING BAR DIA. SPACING
CF1 5.3 2.1 600 16 200 12 150
CF2 6.3 2.4 600 16 200 16 200
677.7702 972.7694
651.9251 946.9243
65.8797
65.1418
64.8144
65.2374
65.6314
65.9353
65.8136
65.5911
65.9537

Sum 589.9984