B.E. (Electrical Engineering (Electronics & Power)) Eighth Semester (C.B.S.)


Computer Applications in Power System

P. Pages : 2 NRJ/KW/17/4718
Time : Three Hours *0178* Max. Marks : 80
_____________________________________________________________________
Notes : 1. All questions carry marks as indicated.
2. Solve Question 1 OR Questions No. 2.
3. Solve Question 3 OR Questions No. 4.
4. Solve Question 5 OR Questions No. 6.
5. Solve Question 7 OR Questions No. 8.
6. Due credit will be given to neatness and adequate dimensions.
7. Assume suitable data whenever necessary.

1. a) Derive an expression for brand admittance matrix using singular transformation. 7

b) For given figure 1 determine A, Â, B, B̂, C, Ĉ & K . Use node 1 as reference and select 13
elements 2 and 5 as a link.

2 3
2
3 5
1

4
1 4
Figure 1

OR

2. a) For network shown in figure 2 obtain YBUS, YBR and Zloop by singular transformation. 15
Network impedances are given in P.U.

1 4 2 5 3

0.5 PU (0.4PU) 1PU


0.5 PU
2
1 3
0.4
PU

0 ref Figure 2

b) Write short note on primitive network. 5

3. a) Derive expression for formation of ZBUS when added element p - q is a link to the existing 10
partial network. Start from performance equation of partial network. Also modify it after
eliminating the fictitious link.

NRJ/KW/17/4718 1 P.T.O

www.rtmnuonline.com
rtmnuonline.com

b) For network shown in figure 3 form ZBUS by Algorithm method. 10


3 4
0.4

0.5 0.2
0.6

0.4
ref 1 Figure 3 2

OR
4. Form BUS impedance matrix ZBUS using algorithm for a given power system network 20
shown in figure 4.
G1 0.3 j0.5 G2 0.2

om
1 2

e.c
lin
j0.56 j0.4

on
j0.35

nu
rtm
3 Figure 4
5, a) w.
How three phase network component is represented in impedance and admittance form. 10
ww

Write down the performance equation in both the forms.


b) Using transformation matrix ' TS ' transform the three phase impedance matrix to its 10
equivalent in 0, 1, 2 sequence quantities. Assume stationary elements.
OR
6. a) Represent three phase power system for short circuit studies for a fault at bus 'P'. 6
om
e.c

b) For three phase to ground fault at bus 'P' in a power system derive an expression for (i) fault 14
lin

current (ii) faulted Bus voltage (iii) voltages at other buses during fault (iv) current through
on

network elements during fault.


nu
rtm

7. a) Draw the flow chart for Gauss - Seidal iterative method using YBUS for load flow studies. 10
w.

b) Compare Gauss - Seidal and Raphson method. 5


ww

c) Give the classification of Buses for Load Flow Studies. 5


OR
8. a) Why the study of transient stability is needed what are the assumptions considered in its 5
study.
b) A 4 pole, 60 MVA synchronous machine running at 1500 rpm delivers 55 MW power at an 15
infinite bus through transmission line. Generator has inertia constant of 4 MJ/MVA and
voltage behind transient reactance E  1.05 . Voltage at infinite bus is 1 0 P.U.
Find variation of  and  against time by modified Euler's method. Assume prefault
transmission system reactance 0.15 PU, during fault transmission system reactance 0.55 PU
and post fault transmission system reactance of 0.3 PU. Take time step of 0.05 sec. Assume
fault is cleared at 0.13 sec. Carry out iterations upto 0.15 sec. Plot  and  against time.
Direct axis transient reactance is 0.4 PU.
************

NRJ/KW/17/4718 2