You are on page 1of 64

FIBERBOND® ADVANCED

COMPOSITE PIPING SYSTEMS

Presented by: Eric Lai


Pacific Advance
Composites Sdn. Bhd.

FIBERBOND® ADVANCED COMPOSITE PIPING SYSTEM


Background of GRP piping

 Buried underground.
 Fully covered by soil.
 Practice socket joint.
 Concerned on hoop
strength only.
 Less branches / min.
loop points.
 Non-critical services.

FIBERBOND® ADVANCED COMPOSITE PIPING SYSTEM


Advantages of GRP piping

 Zero corrosion.
 Light weight.
 Economical.

FIBERBOND® ADVANCED COMPOSITE PIPING SYSTEM


FIBERBOND® Advanced Composite Piping
Systems- Products/Services application

FIBERBOND® ADVANCED COMPOSITE PIPING SYSTEM


FIBERBOND® ADVANCED
COMPOSITE PIPING SYSTEM

 Wave movement.
 Displacement between
two or more
modules/platforms.
 Bending Strength/Stress.

FIBERBOND® ADVANCED COMPOSITE PIPING SYSTEM


Advanced Winding Angles to Change
Various Properties

3 Degree to
87 Degree to increase
increase Axial Strength
Hoop Strength

54 Degree
Is the optimum
Strength for Hoop, Axial,
and Bending
FIBERBOND® ADVANCED COMPOSITE PIPING SYSTEM
FIBERBOND® ADVANCED COMPOSITE
PIPING SYSTEM - Winding Angles

FIBERBOND® ADVANCED COMPOSITE PIPING SYSTEM


FIBERBOND® Pipe Engineering
“Your Partner in Design”

 Combination of
Fiberglass with
Thermosetting resin.
 Non-homogenous
piping.
 Material properties are
different.
FIBERBOND® ADVANCED COMPOSITE PIPING SYSTEM
FIBERBOND® Pipe Engineering
Different Material Properties

FIBERBOND® ADVANCED COMPOSITE PIPING SYSTEM


FIBERBOND® Pipe Engineering
“Your Partner in Design”

 Perform Stress analysis.


 Design of secondary pipe supports, guides,
and anchors based on stress analysis result.
 Mark-up on isometric drawings.
 Standard loads cases based on UKOOA
code.

FIBERBOND® ADVANCED COMPOSITE PIPING SYSTEM


FIBERBOND® Advanced Composite
Piping Systems Designed Criteria

 Joint Method  Pumps & Valves


 Design  Surge Force / Water
Temperature Hammering
 Design Pressure  Pipe Supports
 Service Medium  Fire Endurance
 Thermal Expansion  Static Electricity
 Bending Forces  UV Protection

FIBERBOND® ADVANCED COMPOSITE PIPING SYSTEM


What about other GRP Vendors?!

 Designed for buried  Didn’t apply UV


pipeline application absorber in piping
 Joint method designed  Didn’t meet static
for buried underground electricity requirement
 Engineering work done
by Engineering
Consultant instead of
themselves

FIBERBOND® ADVANCED COMPOSITE PIPING SYSTEM


GRP piping system – Joint Method

 Selection of Joint method is the most critical


part because in GRP piping system, there’s
NO NDT to determine the joint quality.
 Besides, it’s highly depends on
Workmanship skill during installation.

FIBERBOND® ADVANCED COMPOSITE PIPING SYSTEM


Socket Joint – Adhesive Glue

 Copy from PVC joint


method.
 Concerned about Hoop
strength only.
 This is Internal & Precision
joint.
 Can’t visual any air bubble
inside.
 Can’t determine curing
status of the non-reinforced
adhesive glue.
FIBERBOND® ADVANCED COMPOSITE PIPING SYSTEM
Socket Joint – Adhesive Glue

 Excessive adhesive glue


inside the joint created fluid
obstruction.
 Hot-Work required(heating
blanket) for curing purpose.
 No QA/QC (NDE) prior
Hydrostatic Test.
 HIGH FAILURE RISK and
HSE issue because of
bursting & flying fittings.

FIBERBOND® ADVANCED COMPOSITE PIPING SYSTEM


Socket Joint – Failures Without Notice

Pipe Support of 20”


GRE pipe dented
Dislodge
from flange

Pipe slam down


without notice

FIBERBOND® ADVANCED COMPOSITE PIPING SYSTEM


Socket Joint – Failures Without Notice

FIBERBOND® ADVANCED COMPOSITE PIPING SYSTEM


Socket Joint – Report/Document from
3rd Party

 MAERSK Ngujima-Yin FPSO fire report


(page 21).
 API 14G Recommendation Pratices
Document – Appendix D (page 34).
 Dulang-B HSE Alert.

FIBERBOND® ADVANCED COMPOSITE PIPING SYSTEM


FIBERBOND® - TigerWrapTM Plain End
Butt & Wrap Joining Method

 Patented enhanced
joint technology of
Butt & Strap.
 Stronger than Pipe
in Axial Tension,
Axial Compression,
Bending and
External Pressure.

FIBERBOND® ADVANCED COMPOSITE PIPING SYSTEM


Results of Bending Tests by
US Coast Guard

MAXIMUM BENDING LOADS

25000
Max. Load (lb)

20000
15000
10000
5000
0

Straight by Straight by Taper by Taper Butt and Strap


Taper Taper Adhesive
Adhesive Adhesive

Bending Load (lb)


FIBERBOND® ADVANCED COMPOSITE PIPING SYSTEM
FIBERBOND® - TigerWrapTM Plain
End Butt & Wrap Joining Method

FIBERBOND® ADVANCED COMPOSITE PIPING SYSTEM


FIBERBOND® - TigerWrapTM Fit-up
preparation

FIBERBOND® ADVANCED COMPOSITE PIPING SYSTEM


FIBERBOND® - TigerWrapTM Fit-up
preparation

FIBERBOND® ADVANCED COMPOSITE PIPING SYSTEM


FIBERBOND® - TigerWrapTM Resin
& Reinforcement preparation

FIBERBOND® ADVANCED COMPOSITE PIPING SYSTEM


FIBERBOND® - TigerWrapTM Joint

FIBERBOND® ADVANCED COMPOSITE PIPING SYSTEM


TigerWrapTM - QA/QC

FIBERBOND® ADVANCED COMPOSITE PIPING SYSTEM


TigerWrapTM - QA/QC

FIBERBOND® ADVANCED COMPOSITE PIPING SYSTEM


TigerWrapTM - QA/QC

FIBERBOND® ADVANCED COMPOSITE PIPING SYSTEM


TigerWrapTM – Complete Joint

FIBERBOND® ADVANCED COMPOSITE PIPING SYSTEM


Non-Destructive Evaluation in Accordance
ISO 14692 - Barcol hardness gauge

FIBERBOND® ADVANCED COMPOSITE PIPING SYSTEM


FIBERBOND® - TigerWrapTM Plain
End Butt & Wrap Joining Method

 Ease to Modify.  No hot-work


 Stronger than required.
socket glue joint  External joint come
under bending load. with resin &
 NDE inspection reinforcement.
prior hydrostatic
test.

FIBERBOND® ADVANCED COMPOSITE PIPING SYSTEM


What is Static Electricity?

 Disturbing events produced by atmospheric


or various natural or manmade electrical
effects.
 Flow of fluid inside the pipe or changing
atmospheric electrical fields outside the pipe.

FIBERBOND® ADVANCED COMPOSITE PIPING SYSTEM


Static Electricity

 Standard composite
pipe is not
conductive.
 Regardless of fluid
being carried,
conductive piping
must satisfy the risk
in hazardous area.

FIBERBOND® ADVANCED COMPOSITE PIPING SYSTEM


Static Electricity – Other GRP
Vendor

 Conductive filaments
are insulated by
resin rich layer.
 Area between
filaments is not
conductive.

FIBERBOND® ADVANCED COMPOSITE PIPING SYSTEM


Static Electricity – FIBERBOND®
Piping System

 Fully Exterior
surface covered
with conductive
layer.

FIBERBOND® ADVANCED COMPOSITE PIPING SYSTEM


Static Electricity – FIBERBOND®
Piping System

 Grounding to
nearest support
point with cable
lug.

FIBERBOND® ADVANCED COMPOSITE PIPING SYSTEM


Ultraviolet Protection

 GRP piping system


for offshore used
expose to sunlight
always.
 Hence, the piping
system without UV
protection will cause
“Fiber-Bloom” effect.

FIBERBOND® ADVANCED COMPOSITE PIPING SYSTEM


Ultraviolet Protection – Other GRP
Vendor

 No add-in any UV
absorber additive.
 Resin degraded
and appearance of
glass fiber.
 Caused skin
irritation.

FIBERBOND® ADVANCED COMPOSITE PIPING SYSTEM


Ultraviolet Protection -
FIBERBOND® Piping System

Shell MARS New Valve


After 8 Years Installed in
UV Exposure Header at Site

FIBERBOND® ADVANCED COMPOSITE PIPING SYSTEM


Our Real Competitors – Metallic
Alloy Materials (Homogenous)

 API 14G Recommendation Pratices


Document – Appendix D (page 34) stated
Carbon Steel, Copper Nickel, and Stainless
Steel fall under approved material selections
for FW line.

FIBERBOND® ADVANCED COMPOSITE PIPING SYSTEM


FIBERBOND® GRP Piping VS
Metallic Piping

 Carbon Steel Piping


- Low cost and most commonly used.
- But, short service life because corrosion
issue.
 Stainless Steel Piping
- High heat resistance, can withstand
mechanical abuse.
- But, facing pitting attack and corrosion issue.
FIBERBOND® ADVANCED COMPOSITE PIPING SYSTEM
FIBERBOND® GRP Piping VS
Metallic Piping

 Copper Nickel Piping


- Longer service life, light weight, minimal
marine growth.
- But, thin wall thickness, controlled on flow
velocities to avoid erosion, required high
qualified brazer/welder, high cost, need to
handle with care, and good in conduct heat.

FIBERBOND® ADVANCED COMPOSITE PIPING SYSTEM


FIBERBOND® GRP Piping VS
Metallic Piping

 FIBERBOND® GRP Piping


- Designed life >20years.
- No Hot-work required.
- Light weight, not required special lifting tools.
- In-situ repair/modification/replacement.
- Local availability with swift support/response.
- No maintenance.

FIBERBOND® ADVANCED COMPOSITE PIPING SYSTEM


Fire Test – U.S.Coast Guard

 No additional passive
fire resistant
materials.
 Loaded Firewater
Ringmain Pipe
Designed in
Accordance with PFM
1-98

FIBERBOND® ADVANCED COMPOSITE PIPING SYSTEM


Fire Test - U.S.Coast Guard

 Piping to be
Hydrotested After
Fire Test at the
Rated Pressure for
15 Minutes.
Leakage Rate
Should Not Exceed
0.2 I/min

FIBERBOND® ADVANCED COMPOSITE PIPING SYSTEM


Jet Fire Test

 U.S. Coast Guard


Jet Fire Test to
Qualify
FIBERBOND
Series 20JF Dry
Deluge Piping
Subchapter Q
Approval per
PFM 1-98

FIBERBOND® ADVANCED COMPOSITE PIPING SYSTEM


Jet Fire Test

 FIBERBOND
Pipe Yields
Through the Pipe
Wall Leaving the
Joint Intact While
Maintaining the
Design Pressure
and Delivering
Water to the
Firewater System
FIBERBOND® ADVANCED COMPOSITE PIPING SYSTEM
Fire Test – Copper Nickel

 Stagnant Water
Inside 90/10
Copper Nickel
Piping Builds Up
Super Heated
Steam Leading to
“Catastrophic
Failure” Less
Than 20 Minutes

FIBERBOND® ADVANCED COMPOSITE PIPING SYSTEM


FIBERBOND® Advanced Composite Piping
Systems

FIBERBOND® ADVANCED COMPOSITE PIPING SYSTEM


FIBERBOND® Advanced Composite Piping
Systems

FIBERBOND® ADVANCED COMPOSITE PIPING SYSTEM


FIBERBOND® Advanced Composite Piping
Systems

FIBERBOND® ADVANCED COMPOSITE PIPING SYSTEM


FIBERBOND® Advanced Composite Piping
Systems – Special Fittings

FIBERBOND® ADVANCED COMPOSITE PIPING SYSTEM


FIBERBOND® Advanced Composite Piping
Systems – Special Fittings

FIBERBOND® ADVANCED COMPOSITE PIPING SYSTEM


FIBERBOND® Advanced Composite Piping
Systems – Special Fittings

FIBERBOND® ADVANCED COMPOSITE PIPING SYSTEM


FIBERBOND® Advanced Composite Piping
Systems – Column Piping

FIBERBOND® ADVANCED COMPOSITE PIPING SYSTEM


FIBERBOND® Advanced Composite Piping
Systems – Column Piping

FIBERBOND® ADVANCED COMPOSITE PIPING SYSTEM


FIBERBOND® Advanced Composite Piping
Systems – Robust Piping System

FIBERBOND® ADVANCED COMPOSITE PIPING SYSTEM


FIBERBOND® Advanced Composite Piping
Systems – Spectacle Blind

FIBERBOND® ADVANCED COMPOSITE PIPING SYSTEM


Simple Vertical Support & U-bolts
on alternate support

FIBERBOND® ADVANCED COMPOSITE PIPING SYSTEM


Anchor Restrains All Movement

FIBERBOND® ADVANCED COMPOSITE PIPING SYSTEM


FIBERBOND® Advanced
Composite Piping Systems

 13 years Track Record with ZERO catastrophe


failure and ZERO repair order from clients.
 Ahead of Schedule.
 Not involve in any court case.
 Designed met Offshore & Marine services
requirements.
 Warrant WHOLE FIBERBOND® Advanced
Composite Piping Systems.

FIBERBOND® ADVANCED COMPOSITE PIPING SYSTEM


FIBERBOND® Advanced
Composite Piping Systems

 3 Long Term
Contracts
 Received OVA
from PCSB in Yr
2012 and Yr 2013.

FIBERBOND® ADVANCED COMPOSITE PIPING SYSTEM


FIBERBOND® Advanced
Composite Piping Systems

FIBERBOND® ADVANCED COMPOSITE PIPING SYSTEM


FIBERBOND® Advanced
Composite Piping Systems

 www.fiberbond.com
 www.dialogasia.com

FIBERBOND® ADVANCED COMPOSITE PIPING SYSTEM

You might also like