You are on page 1of 2

Desalter

Oil.
No matter
how you
Trouble
drill it,
pump it, Shooting
recover it,
enhance it,
store it,
Guide
transport it,
Worldwide Headquarters
pipeline it, 12645 West Airport Blvd.
desalt it, Sugar Land, Texas 77478
distill it,
P.O. Box 5050
hydrotreat it, Sugar Land, Texas 77487-5050
crack it, Toll Free: 1-800-231-3606
additize it, Fax: 281-276-7395
Internet: www.bakerhughes.com/bapt
or
market it,

Baker
Petrolite The information and recommendations contained herein are believed to
has treated more oil, be accurate and reliable as of the date hereof; however we do not war-
rant or represent their accuracy of reliability.
in more places,
Disclaimer of Liability: Baker Petrolite Corporation (BPC) warrants to
for a longer time, purchaser, but no third parties or others, the specifications for the product
shall fall within a generally recognized range for typical physical
than anyone properties established by BPC when the product departs BPC's point of
origin and that any services shall only be performed in accordance with
in the applicable written work documents. BPC MAKES NO OTHER WARRANTY
OR GUARANTEE OF ANY KIND, EXPRESS OR IMPLIED, INCLUDING NO
business. IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A
PARTICULAR PURPOSE, REGARDING ANY SERVICES PERFORMED OR
PRODUCT SUPPLIED. BPC will give purchaser the benefit of BPC's best
Period. judgement in making interpretations of data, but does not guarantee the
accuracy or correctness of such interpretations. BPC's recommendations
contained herein are advisory only and without representations as to the
results. BPC shall not be liable for any indirect, special, punitive,
exemplary or consequential damages or losses from any cause whatsoever
including but not limited to its negligence.
©1999 Baker Hughes Incorporated.
All rights reserved. BP0044 (2/99) 2.5M
✓✓ = check first ✓ = check second

Desalter Situation
High Salt High Salt
High BS&W Carryover Carryover
High Oil Wide High Amps,
in Desalted w/High w/Normal
Undercarry Interface Low Volts
Crude Water Water
Carryover Carryover
Items to Check Typical Range
✓ ✓✓ ✓✓ ✓✓ ✓✓ ✓ Crude Change/Crude Tank Switch?
✓ ✓ ✓ ✓ ✓ Poor Wash Water Quality/High pH? pH 6.0-7.5
✓ ✓ ✓✓ Low Wash Water Rate? 4-8%, typ. 5%
✓ ✓✓ ✓✓ ✓ ✓ Poor Quality/High Quantity of Slop Oil?
✓✓ ✓✓ ✓✓ ✓✓ ✓✓ Desalter Mix Valve DP High? 2-25 psig
✓✓ ✓✓ Desalter Mix Valve DP Low? 2-25 psig
✓ ✓ ✓ ✓ Demulsifier Rate High?
✓ ✓✓ ✓ ✓ ✓ Demulsifier Rate Low?
✓ ✓✓ ✓✓ Water Level High? *
✓✓ ✓ Water Level Low?/Water Residence Time Low? 125-165 minutes
✓✓ ✓✓ ✓✓ ✓✓ Desalter Level Controller Operating OK?
✓ ✓ ✓ ✓ Desalter Back Pressure Fluctuating?
✓ ✓ ✓ ✓ Cycletric® Desalter Distributor DP OK? 3-7 psig
✓ ✓ ✓ ✓ ✓ Desalter Temperature OK? 240-300 F
✓ Desalter Pressure Low?
✓ ✓ ✓ Crude Rate Increased?
✓✓ ✓✓ ✓✓ Electrical System OK?
© 1999 Baker Petrolite Corporation *Water level should be kept as high as practical, generally 1-2ft. below the bottom grid for PETRECO® Desalters.