You are on page 1of 4

Ref. No.

D 04903
CHECK VALVE Release: 01 / 2018
Model : C
*** ENGINEERING - 1 of 4
A Polyhydron Group Company

Description
Check valve models C
*** allow free flow in the direction from Port A to
Port B and offer leak free closure in opposite direction.

Two standard mounting styles are avaliable:


- Line mounting C *T.
- Subplate mounting C*S.

Section Hydraulic symbol

Subplate body Threaded body

A B
A B

A B

Technical specifications
Construction : Seat type valve.
Mounting style : Threaded port or subplate mounting.
Mounting interface : Factory standard.
Mounting position : Optional.
Flow direction : Free flow from A to B, Leakfree closure in opposite direction.
Cracking pressure : 0, 0.5, 1.5, 3 and 5 bar.
Working pressure : 315 bar for Ports A and B .
Hydraulic medium : Mineral oil.
Temperature range : -20°C to + 80°C.
Viscosity range : 10 cSt to 380 cSt.
Fluid cleanliness required : ISO 4406 20/18/15 or better.
Max. flow handling capacity : Refer graphs.
Mass approx.
(Subplate mounting) : Model : 06 08 10 15 20 25 30
in Kg : 0.1 0.15 0.3 0.45 0.9 2 2.4
(Line mounting) : Model : 06 10 20 30
in Kg : 0.3 1 2.4 7.2

Phone : +91-(0)831- 2411001


Fax : +91-(0)831- 2411002
78-80, Machhe Industrial Estate,
E-mail : polyhydron@gmail.com
Machhe, Belgaum - 590 014. INDIA.
Website : www.polyhydron.com
D 04903-C
A Polyhydron Group Company ENGINEERING - 2 of 4
***

Unit dimensions Dimensions in mm.

Threaded port body

L1 A/F
T1 T1

BSP port BSP port

A B

Size 06 08 10 15 20 25 30

BSP
G1/4 G3/8 G1/2 G3/4 G1 G1 1/4 G 1 1/2
Port

L1 58 58 72 85 98 120 132

T1 12 12 14 16 18 20 22

A/F 19 24 30 36 46 60 65

Subplate mounting body

Subplate body mounting


interface
L7
A B
L6
ØD2 Drill,
B1

L5
T1 deep
L4
L2 L3
B2

B2

L2 ØD3 max
B3

L1
B1

B4

A B

A B
H1

ØD4 tap,
A B
T2 deep

ØD1
H2

Valve fixing Tightening


Size ØD3
L1 L2 L3 L4 L5 L6 L7 B1 B2 B3 B4 H1 H2 ØD1 ØD2 ØD4 T1 T2 S.H.C Screws Torque
max Class 12.9 Nm

M6 x 35L
06 51 7 3 9 15 18 45 37 7.5 11 22 26 3.5 3 4 6 M6 5 12 4 nos
16

M8 x 50L
10 74 9 6 16.5 27 33 68 55 9.5 18 36 38 3.5 3 4 11 M8 5 14 39
4 nos
M10 x 70L
20 102 10 10 27.5 45 55 95 70 10 25 50 55 5.5 6 7 22 M10 8 19 4 nos
77
M12 x 100L
30 139 15 20 42.5 65 85 132 100 12.5 37.5 75 82 5.5 6 7 31 M12 8 22 4 nos
135

All rights reserved.


Subject to revision
D 04903-C
A Polyhydron Group Company ENGINEERING - 3 of 4
***

Ordering code
C 06 T 1 03

Check valve Design code subjected to Change .


installation dimensions remain
Port size same for design code 09 thru 19.
Threaded Subplate
Size
body mounting
G1/4 Ø 06 max 06 Cracking pressure (bar)
G3/8 --- 08
G1/2 Ø 11 max 10 0 1 2 3 4
G3/4 --- 15
0.0 0.5 1.5 3.0 5.0
G1 Ø 22 max 20
G1 1/4 --- 25
G1 1/2 Ø 31 max 30 S Subplate mounting body
T Threaded port body

Performance graph

Check valve C06S Check valve C06T

5 bar
Pressure drop ΔP (bar)

Pressure drop ΔP (bar)

5 bar
3 bar

1.5 bar

0.5 bar 1.5 bar 3 bar

Without spring 0.5 bar

Without spring

Flow Q (l/min) Flow from Port A to Port B Flow Q (l/min) Flow from Port A to Port B

Check valve C08T


Pressure drop ΔP (bar)

3 bar 5 bar

1.5 bar

0.5 bar

Without spring

Flow Q (l/min) Flow from Port A to Port B

Check valve C10S Check valve C10T

5 bar
3 bar
5 bar
Pressure drop ΔP (bar)

Pressure drop ΔP (bar)

3 bar

1.5 bar 1.5 bar

0.5 bar
0.5 bar Without spring
Without spring

Flow Q (l/min) Flow from Port A to Port B Flow Q (l/min) Flow from Port A to Port B

All rights reserved.


Subject to revision
D 04903-C
A Polyhydron Group Company ENGINEERING - 4 of 4
***

Check valve C15T

5 bar
3 bar
Pressure drop ΔP (bar)

1.5 bar

0.5 bar

Without spring

Flow Q (l/min) Flow from Port A to Port B

Check valve C20S Check valve C20T

5 bar
5 bar
Pressure drop ΔP ( bar)

Pressure drop ΔP (bar)


3 bar

3 bar
1.5 bar
1.5 bar
0.5 bar
0.5 bar
Without spring
Without spring

Flow Q (l/min) Flow from Port A to Port B Flow Q (l/min) Flow from Port A to Port B

Check valve C25T

5 bar
3 bar
Pressure drop ΔP (bar)

1.5 bar

0.5 bar

Without spring

Flow Q (l/min) Flow from Port A to Port B

Check valve C30S Check valve C30T

5 bar
Pressure drop ΔP (bar)

Pressure drop ΔP (bar)

5 bar
3 bar

3 bar
1.5 bar

0.5 bar 1.5 bar


0.5 bar

Without spring Without spring

Flow Q (l/min) Flow from Port A to Port B Flow Q (l/min) Flow from Port A to Port B

All rights reserved.


Subject to change without prior notice.
Due to continuous improvement in the design of the product, the actual product supplied may look different than shown above.
For critical applications, please ask for certified installation drawing.

All rights reserved.


Subject to revision

You might also like