You are on page 1of 4

Snow load

S=gi,s x mi x Ce x Ct x Sk = 1x1x0.8x1x1.5= 1.2 KN/m2


Location: Cluj: Sk= 1.5 KN/m²
Building importance: Class 3 - gi,s=1
Exposure of the building: Normal exposure – Ce=1
Thermal coefficient: No thermal transmittance – Ct=1
Angle of the roof: 0° - mi=0.8

Wind load
Timisoara qb= 0.5 KPa
Terrain category 4: zmin=10 ; z0=1 ; Kr2(z0)= 0.054 ; β=2.12
LONGITUDINAL
For z=h
qp= ce(z) x qb= 0.837 x 0.5= 0.42 KPa = 0.42 KN/m2
ce(z)= cpq(z) x cr2(z)= 2.701x 0.31= 0.837
cpq(z)= 1+7Iv(z)=1+7x0.243=2.701
Iv(z)=sqrt(β)/(2.5ln(z/z0))= sqrt(2.12)/(2.5ln(11/1))= 0.243
cr2(z)= Kr2(z0) x [ln(z/z0)]2= 0.054 x [ln(11/1)]2= 0.31
For z=b
qp= ce(z) x qb= 0.803x0.5= 0.403 KPa= 0.403 KN/m2
ce(z)= cpq(z) x cr2(z)= 2.806 x 0.286= 0.803
cpq(z)= 1+7Iv(z)=1+7x0.258= 2.806
Iv(z)=sqrt(β)/(2.5ln(z/z0))= sqrt(2.12)/(2.5ln(10/1))= 0.258
cr2(z)= Kr2(z0) x [ln(z/z0)]2= 0.054 x [ln(10/1)]2=0.286
Wind action on each structure zone:
we=γIw x cpe x qp(ze)
γIw= 1 (structure class 3)
For qp(ze)= qp(h)
A: we=γIw x cpe x qp(ze)= 1x(-1.2)x0.42 =-0.504 KN/m2
B: we=γIw x cpe x qp(ze)= 1x(-0.8)x0.42 =-0.336 KN/m2
C: we=γIw x cpe x qp(ze)= 1x(-0.5)x0.42=-0.21 KN/m2
D: we=γIw x cpe x qp(ze)= 1x0.709x0.42 =0.298 KN/m2
E: we=γIw x cpe x qp(ze)= 1x(-0.317)x0.42=-0.113 KN/m2
For qp(ze)= qp(b)
A: we=γIw x cpe x qp(ze)= 1x(-1.2)x0.403=-0.48 KN/m2
B: we=γIw x cpe x qp(ze)= 1x(-0.8)x0.403=-0.32 KN/m2
C: we=γIw x cpe x qp(ze)= 1x(-0.5)x0.403=-0.202 KN/m2
D: we=γIw x cpe x qp(ze)= 1x0.709x0.403=0.28 KN/m2
E: we=γIw x cpe x qp(ze)= 1x(-0.317)x0.403=-0.128 KN/m2

TRANSVERSAL
For z=h
qp= ce(z) x qb= 0.837 x 0.5= 0.42 KPa = 0.42 KN/m2
ce(z)= cpq(z) x cr2(z)= 2.701x 0.31= 0.837
cpq(z)= 1+7Iv(z)=1+7x0.243=2.701
Iv(z)=sqrt(β)/(2.5ln(z/z0))= sqrt(2.12)/(2.5ln(11/1))= 0.243
cr2(z)= Kr2(z0) x [ln(z/z0)]2= 0.054 x [ln(11/1)]2= 0.31
Wind action on each structure zone:
we=γIw x cpe x qp(ze)
γIw= 1 (structure class 3)
For qp(ze)= qp(h)
A: we=γIw x cpe x qp(ze)= 1x(-1.2)x0.42=-0.504 KN/m2
B: we=γIw x cpe x qp(ze)= 1x(-0.8)x0.42=-0.336 KN/m2
D: we=γIw x cpe x qp(ze)= 1x0.8x0.42=0.336 KN/m2
E: we=γIw x cpe x qp(ze)= 1x(-0.505)x0.42= -0.21 KN/m2
LONGITUDINAL
b=10 m
d=35 m
e=min(b;2d)= 10 m
e>d; 5 zones A B C D and E
e/5=10/5= 2 m
h/d= 11/35=0.314
A: cpe= -1.2
B: cpe= -0.8
C: cpe= -0.5
D: cpe= 0.709
E: cpe= -0.317
TRANSVERSAL
b=35 m
d=10 m
e=min(b;2d)= 22 m
e>d; 4 zones A B D and E
e/5=22/5= 4.4 m
h/d= 11/10=1.1
A: cpe= -1.2
B: cpe= -0.8
D: cpe= 0.8
– E: cpe= -0.505