Contents
Preface ............................................................................................................................ 3
Creating the 9030 Macro Program .................................................................................. 4
Installing the 9030 Macro program .................................................................................. 5
Setting the Scheduler .................................................................................................... 14
Running the Scheduler .................................................................................................. 18
Preface
This document describes the method of using the Type II Vipros King Scheduler
included with the Fanuc 18P control.
The Type II Vipros King Scheduler allows up to 26 individual part programs, in desired
quantities, to be run in sequence with no operator intervention.
The procedure to use the Scheduler consists of the following steps.
1) Create the 9030 Macro program.
2) Install the 9030 Macro program in the Fanuc 18P control memory.
3) Load the desired G-code part programs in the Fanuc 18P control memory.
4) Set the Scheduler to run the required quantities of desired programs.
5) Run the Scheduler.
O9030(NCT-JOB-E-1B)(MODIFIED BY SWANK)
N001IF[#504GT0]GOTO2
#504=1
#500=1
#501=0
#502=0
#503=0
N002IF[#500GT26]GOTO4
#514=#[515+#500]
#515=#[541+#500]
#503=#503-1.
#502=#515+#503
#501=#501+1.
IF[#515GE#501]GOTO3
#501=0
#503=0
#500=#500+1.
GOTO2
N003M96P#514
N004#504=0
#3000=53
%
Press pushbutton.
What you will see The display will change to show:
happen.
The softkey.
softkey.
What you will see The display will change to show:
happen. PARAMETER (SYSTEM CONFIG).
Parameter 9933 values highlighted.
What you need to do. Record the current value of parameter 9933
softkey.
What you will see The display will change to show:
happen. PARAMETER (CRT/MDI/EDIT)
Parameter 3202.
What you need to do. Record the current value of parameter 3202:
Press softkey.
What you will see The display will change to show:
happen.
The softkey.
What you need to do. Place the floppy disk containing the 9030 Macro
program into the floppy drive and close the floppy
drive door.
Press pushbutton
What you will see The lamp on the Edit pushbutton will illuminate.
happen.
Press key.
What you will see The display changes to show:
happen. The currently active program.
What you need to do. Enter the displayed file number of the 9030 Macro
softkey.
What you will see The display will change to show;
happen. The FILE NO= (file number entered) PROGRAM
NO=9030.
Press pushbutton
What you will see The display will change to show:
happen.
The softkey.
softkey.
What you will see The display will change to show:
happen. PARAMETER (CRT/MDI/EDIT)
Parameter 3202.
Press pushbutton
What you will see The display will change to show:
happen.
The softkey.
What you need to do. Using the number keys enter the four digit part
program number.
What you will see happen. The display will change to show:
The four digit number in the NUM=> area.
What you need to do. Using the number keys enter the quantity of sheets.
What you will see happen. The display will change to show:
The quantity in the NUM=> area.
The softkey.