1
between the two parts and is possible calculate with
this formula :
I
P= di
d do2 + d 2 d di 2 + d 2
* +Vo + * -Vi
Eo do2 - d 2 Ei di 2 - d 2
where :
P: means pressure of contacts expressed in N/mm^2
I: means interference between the hub and shaft
expressed in mm
d: Nominal rim diameter expressed in mm
Eo: Hub Young's modulus expressed in N/mm^2 d
do: Hub outer diameter expressed in mm
vo: Hub Poisson's Modulus
Ei: shaft Young's modulus expressed in N/mm^2
di: shaft internal diameter expressed in mm
vi: shaft Poisson's Modulus
As is demonstrated in the formula above the pressure
of contact depends mainly by the interference do
between the two parts joined in press fit process.
To calculate the minimum force necessary to press fit
the parts now is necessary use this formula : In case the press fit force value Fp result more bigger
than the maximum force admissible F before the
Fp= P*η*d*π*L deformation is necessary working on the interference
during the introduction by a cooling down of the shaft
where : or by a warming up of the hub. Another good
practices easy to implement and very affordable is the
Fp: means the press fit Force expressed in N use of lubricant to reduce the friction between the hub
and shaft or with a reduction of the surfaces
P : means the pressure of contact expressed in roughness. The last instance is the reduction of the
N/mm^2 joint length.
The values obtained by the use of the formulas above
η : means the friction between hub and shaft are purely indicative. Auloma suggest test in
laboratory to determinate the right press fit force
d : means the nominal diameter of joint (hub, shaft) value. Auloma reject any liability for any damages for
expressed in mm gods or person about the use of the formula
expressed above.
π: 3,1 4
L: length of the joint between hub and shaft
expressed in mm.
2
Auloma provide
servo presses
until 500 kN