ANNEXURE 1: Fatigue check for prestressed girder

Since there is tensile stress in frequent load combination, as per Clause 5.3.2.5 of IRC:112-2011, fatigue check is
carried out.
As per ANNEXURE A-1 of IRC:112-2011, clause A1-4 (2) for limit state of fatigue, "Specialist literature or internat
may be referred for the same"

Referred code of practice :


1 IRC:6-2017 - Fatigue load considered as per Clause 204.6
2 EN 1991-2 - Fatigue load models (to be applied as fatigue loads) expalined in Clause 4.6
3 EN 1992-1-1
4 EN 1992-2

Clause 6.8.5 Verification of fatigue resistance using damage equivalent stress range
(3) For reinforcing or prestressing steel and splicing devices adequate fatigue resistance shall
be assumed if the Expression below is satisfied:

�_𝐹.�_𝐸𝑑. 〖∆𝜎〗 _(𝑆,𝑒𝑞𝑢) (𝑁^∗ )≤( 〖∆𝜎〗 _𝑅𝑠𝑘 (𝑁^∗ ))/�_(𝑠,𝑓𝑎𝑡)


EN 1992-1-1 Cl 6.8.5 (3)

〖∆𝜎〗 _(𝑠,𝑒𝑞𝑢)= 〖∆𝜎〗 _(𝑠,𝐸𝑐).λ_𝑠 EN 1992-2 Annex NN, NN.2.1 (102)

λ_𝑠=𝜑_𝑓𝑎𝑡.𝜆_(𝑠,1).𝜆_(𝑠,2).𝜆_(𝑠,3).𝜆_(𝑠,4) EN 1992-2 Annex NN, NN.2.1 (103)

Moment due to self weight of girder 8145 kN-m


Moment due to deck slab and diaphragm 7857 kN-m
Moment due to SIDL (wearing coat) 1144.81 kN-m
Moment due to SIDL (crash barrier) 1270.67 kN-m
Moment due to fatigue load in girder 1850.26 kN-m
Total moment at mid span (frequent combination) 20750.84 kN-m

Moment of inertia of girder 1.7416 m^4 (cracked MI=0.7xGross MI)


Eccentricity of cables 1.109 m
stress at CG of cable in concrete 13.21 MPa
Es 195000 Mpa (For prestressing strands)
Ec 35000 Mpa (For girder)
Stress in steel 73.61822 MPa

〖∆𝜎〗 _(𝑠,𝐸𝑐) 73.62 MPa

𝜑_𝑓𝑎𝑡 1.2 1.2 for surface of good roughness


1.4 for surface of medium roughness
𝜆_(𝑠,1) 1.15 EN 1992-2 Annex NN, NN.2.1 (104) Figure NN.2

𝜆_(𝑠,2) 1 EN 1992-2 Annex NN, NN.2.1 (105)

𝜆_(𝑠,3) 1 EN 1992-2 Annex NN, NN.2.1 (106)

𝜆_(𝑠,4) 1 EN 1992-2 Annex NN, NN.2.1 (107)

〖∆𝜎〗 _(𝑠,𝑒𝑞𝑢)101.59 MPa

〖∆𝜎〗 _𝑅𝑠𝑘 (𝑁^∗ ) 150 MPa


�_(𝑠,𝑓𝑎𝑡) 1.15

( 〖∆𝜎〗 _𝑅𝑠𝑘 (𝑁^∗ ))/�_(𝑠,𝑓𝑎𝑡)


( 〖∆𝜎〗 _𝑅𝑠𝑘 (𝑁^∗ ))/�_(𝑠,𝑓𝑎𝑡)
130.43 MPa OK
IRC:112-2011, fatigue check is required to be

"Specialist literature or international standards

palined in Clause 4.6

istance shall

N, NN.2.1 (102)

N, NN.2.1 (103)

Load factors for frequent combination


1
1
1.2
1.2
1

(cracked MI=0.7xGross MI)

prestressing strands)

EN 1991-2 Annex B (3)


m roughness
) Figure NN.2

You might also like